This document discusses Certificate of Compliance and Completion (CCC) requirements in Malaysia. It outlines that the Principal Submitting Person (PSP), who is a Professional Engineer or Architect, is responsible for issuing the CCC upon satisfactory completion of construction works. The PSP must ensure 21 Form G stage certification forms are duly completed and clearances received from various authorities before issuing the CCC. Mistakes made in filling out forms can result in disciplinary action against the involved professionals.
This document discusses Certificate of Compliance and Completion (CCC) requirements in Malaysia. It outlines that the Principal Submitting Person (PSP), who is a Professional Engineer or Architect, is responsible for issuing the CCC upon satisfactory completion of construction works. The PSP must ensure 21 Form G stage certification forms are duly completed and clearances received from various authorities before issuing the CCC. Mistakes made in filling out forms can result in disciplinary action against the involved professionals.
This document discusses Certificate of Compliance and Completion (CCC) requirements in Malaysia. It outlines that the Principal Submitting Person (PSP), who is a Professional Engineer or Architect, is responsible for issuing the CCC upon satisfactory completion of construction works. The PSP must ensure 21 Form G stage certification forms are duly completed and clearances received from various authorities before issuing the CCC. Mistakes made in filling out forms can result in disciplinary action against the involved professionals.
IEM Vice President Qualification & Admission Committee Chairman Chairman of Executive Board – IEM TC BEM CCC Committee Member Vice Chairman Engineering Accreditatioon Council CCC Certificate of Compliance and Completion Effective Date of CCC 12th April 2007 CCC replaced CF for CFO previously issued by local authority (PBT) CCC issued by the project’s Principal Submitting Person (PSP) – Professional Architect or Professional Engineer Amendments of Relevant Act Street and Drainage Act Uniform Building By-Law 1984 (UBBL) Housing Development Act Strata Title Act Architect’s Act Registration of Engineers Act Role of PBT Receive Process Approve Authorize site inspection – own initiative or act on complain Issue notice – breach or divergence & failure to rectify Reporting to Professional Boards PSP are required to Prepare and present planning and building plans to PBT for approval Inform PBT of the commencement of construction works at site Supervise construction Present work-resumption notice to PBT Ensure Form Gs are duly certified at various stages of work Issue CCC to owner upon satisfactory completion of works Present a copy of CCC (with Forms Gs) to PBT and Professional Boards within 14 days CCC can only be issue after All the certifications by respective parties (profesional, contractors and tradesmen) (Forms G1-G21) Clearances from the following authorities 1. TNB 2. Water Authority 3. Sewerage Services Department(JPP) 4. Bomba (except for residential bldgs of not more than 18 m) 5. Department of Safety & Health (where applicable) 6. Relevant authorities/Public Works on Roads and Drainage 21 Forms Gs • FORM G1 Stage Certificate : Earthworks • FORM G2 Stage Certification : Setting Out • FORM G3 Stage Certification : Foundations • FORM G4 Stage Certification : Structural • FORM G5 Stage Certification : Internal Plumbing • FORM G6 Stage Certification : Internal Sanitary Plumbing • FORM G7 Stage Certification : Internal Electrical • FORM G8 Stage Certification : Fire Fighting (Passive) 21 Forms Gs • FORM G9 Stage Certificate : Fire Fighting (Active) • FORM G10 Stage Certification : Mechanical Ventilation • FORM G11 Stage Certification : Lift/Escalator Installation • FORM G12 Stage Certification : Building • FORM G13 Stage Certification : External Water Supply System • FORM G14 Stage Certification : Sewerage Reticulation • FORM G15 Stage Certification : Sewerage Treatment Plant • FORM G16 Stage Certification : External Electrical Supply 21 Forms Gs • FORM G17 Stage Certificate : Road and Drainage • FORM G18 Stage Certification : Street Lighting • FORM G19 Stage Certification : External Main Drain • FORM G20 Stage Certification : Telecommunication • FORM G21 Stage Certification : Landscape CCC issuance FORM F – Certificate of Compliance and Completion FORM F1 – Partial Cetificate of Completion and Compliance 4 copies Original copy to Developer or House Owner Second copy to be retained Third copy to relevant authority Fourth copy to BEM Warning !!! The parties that issue Forms Gs and CCC without complying to the provisions of the Acts can be sue and reported to BEM Stricter disciplinary action by increasing fine, extending the duration of membership suspension and cancellation of membership Sample of Forms CCC_FORMS_BM_Samples_May08.pdf Examples of errors Inserting design drawing nos. instead of Approval Ref. no. Inserting Contractor Co. Name instead of Individual Name with NRIC no. Name of PBT (Local Authority) Wrong of PE signing as SP in Form Gs Non submission of Form Gs Non enclosure of Clearance Letters from Utilities.