RESULTS REPORT
1
It has the operating NO
conditions of the source?
yes
yes
NO
Laboratory analysis reports comply the
legal requirements?
yes
Analyze the report
2
Stack Sampling Results Report
the results in concentration shall be expressed
in the same oxygen content of the emission
limit
To correct the oxygen is necessary to apply
this expression:
21 y
C ( y %O2 ) Ca
21 x%O2 a
Where: y is the oxygen in the flue gas
◦ x is the oxigen of the emission limit
3
Stack Sampling Results Report
Example: To correct a concentration obtained in a
sampling (135 mg/Nm3 to 9% O2) for the content of
7% oxygen will be:
21 7
C (7%O2 ) 135
21 9
C (7%O2 ) 157,5
4
Stack Sampling Results Report
the results in concentration shall be
expressed in the same unit to the emission
limit
Example: the average readings of
continuous monitor of CO was 100 ppm,
but emission limit is mg/Nm3
5
Concentration Conversion
22,41 mg
ppmv
MM Nm 3
MM = molecular mass
6
Stack Sampling Results Report
the results in concentration shall be
expressed in the same unit to the emission
limit
Example: the average readings of
continuous monitor of CO was 100 ppm,
but emission limit is mg/Nm3
22,41 mg
100
28 Nm3
124,944 mg/Nm3
7
Convert SO3 and H2SO4 to SOx
8
N = normal condition
CNTP
1 atm e 0°C
1 atm e 273 K
1 atm e 492 R
Exercise: The source is attending the emission limits?
Source: Incinerador
Emission Limit to PM: 70 mg/Nm3, base seca a 7% de O2
Report:
Source: Incinerador
Report:
Report:
ND - not detectable
(quantitation limit = 8 mg/Nm3)
Exercise: The source is attending the emission limits?