You are on page 1of 3

ZF AS Tronic(B6)

ZF Italia S.r.l. - Reparto ST-T

© ZF Friedrichshafen AG
Error 125 (air pressure too high) for Euro4 /
Pack 8 software

Up until the Pack 7 software, error 125 was not recognised.


Error 125 was added to the GS3.3 electronic control units with optimised air pressure
sensors.
The pressure reducing valve presents variations in air pressure that are too high,
sporadically exceeding 7.8 bar, in which case error 125 is recognised.

Corrective Action: Installation of new software.


DO NOT REPLACE THE PRESSURE REDUCING VALVE.

For New Domino and Magelis buses with the ZF joystick gear selector or Stralis type
of selector, new software is available in series production.

Type of Gearbox Engine Old software New software Comments


gearbox ID

12AS2301 1348 045 Iveco Cursor10 F3A 6009 397 019 6009 397 019 IS ZF Joystick
BO 014 Euro4 330kW GS Selector
12AS2301 1348 045 Iveco Cursor10 Euro4 6009 397 6009 397 227 HS Stralis Selector
BO 044 330kW 227ES

AS_ 2
Error 125 (air pressure too high) for Euro4 /
Pack 8 software

Reading of the ASTRONIC gearbox ID by the EASY IVECO diagnostics tool


AS_ 3