You are on page 1of 60

Footing Design

Types of Footing
Wall footings are used to
support structural walls that
carry loads for other floors
or to support nonstructural
walls.
Types of Footing
Isolated or single footings
are used to support single
columns. This is one of the
most economical types of
footings and is used when
columns are spaced at
relatively long distances.
Types of Footing
Combined footings usually
support two columns, or
three columns not in a row.
Combined footings are used
when two columns are so
close that single footings
cannot be used or when one
column is located at or near
a property line.
Types of Footing

Cantilever or strap footings


consist of two single
footings connected with a
beam or a strap and support
two single columns. This
type replaces a combined
footing and is more
economical.
Types of Footing
Continuous footings
support a row of three or
more columns. They have
limited width and continue
under all columns.
Types of Footing
Rafted or mat foundation
consists of one footing
usually placed under the
entire building area. They
are used, when soil bearing
capacity is low, column
loads are heavy single
footings cannot be used,
piles are not used and
differential settlement must
be reduced.
Types of Footing
Pile caps are thick slabs
used to tie a group of piles
together to support and
transmit column loads to
the piles.
Distribution of Soil Pressure

When the column load P is


applied on the centroid of the
footing, a uniform pressure is
assumed to develop on the
soil surface below the footing
area. However the actual
distribution of the soil is not
uniform, but depends on may
factors especially the
composition of the soil and
degree of flexibility of the
Distribution of Soil Pressure

Soil pressure distribution in Soil pressure distribution in


cohesionless soil. cohesive soil.
Eccentrically loaded footings
Eccentrically loaded footings
Example
Isolated Footing M
D.L = 900 kN
L.L = 450 kN
Ms = 150kN.m
Mu=200kN.m
qall =200kpa
Area required approximated
qall ( net )  20t / m 2  200kPa
Ps (900  450)  103
Ag    6. 75m 2

qall ( net ) 200  103


use  3.5m  2.5m 
183.7
A  8.75m 2
124.7

I  3.5122.5  8.9m 4
3

Check stress
M 150
e   0.111  L6  36.5  0.583
P 1350
Ps M s C 1350 150  32.5
    183.7 kPa
A I 8.75 8.9
Ps M s C 1350 150  32.5
    124.7kPa
A I 8.75 8.9
Ultimate pressure under footing
Pu  1.2 900  1.6(450)  1800kN
M u  200kN .m
Pu M u C 1800 200  32.5
    245kPa
A I 8.75 8.9
Pu M u C 1800 200  32.5
    166kPa
A I 8.75 8.9

245
166

245
Check Punching Shear

bo  4 (530  400)  3720cm


For square column the suitable VC equation is :
fc ' 25
 VC   bo d  0.75   530  3720 / 1000  2464.5kN
3 3

VU  (166 245166  245)


4
 3.5  2.5  1798kN
Check Beam Shear
25
 VC  0.75   530  2500 / 1000  828.13kN
6

VU at d from column face 


 223  245 
VU    * 1.5  0.53 * 2.5
 2 
 567.5kN
VU  VC
3.5m
Bending moment design
Long direction
245
M U at d from column face  166
P1  211(1.5)(2.5)  791.25kN 245
P2  12 (245  211)(1.5)(2.5)  63.75kN
M U  P1 (0.75)  P2 (1)  791.25(0.75)  63.75(1)  657.2kN .m
b  2500, d  530mm
25  2 106 * 657.2 
  0.85 * 1 - 1 -   0.00254
420  0.9 0.85 25 * 530 * 2500 
2

AS  0.00254  530 1000  1346mm 2  13.5cm 2 use 716 / m long direction


Bending moment design 2.5m
Short direction
M U at d from column face  245
166
  245  166
MU   1 3.5 0.5  719.25kN .m 245
 2 
b  3500, d  530mm
25  2 106 * 719.25 
  0.85 * 1 - 1 -   0.002
420  0.9 0.85 25 * 530 * 3500 
2

AS  0.002  530  1000  1060mm 2  10.1cm 2 short direction


Central band ratio =

3.5
  1.4
2.5
2 2
  0.83
  1 2.4
Central band of short direction = 0.83 As = 0.83 (10.1)=8.6cm2
214 714/m 214

716/m
Footing Design
Part II
Combined footing
Example 1
Design a combined footing As shown

qall ( net )  20t / m 2  200kPa f c  25 N mm 2 f y  420 N mm 2


Dimension calculation
The base dimension to get uniform distributed load
2000kN
kN 800 kN 1200

A
x1=0.2m
x2=6.2m

x
800(0.2)+1200(6.2)=2000(x)
x = 3.8m

kN 800 kN 1200

Try thickness
=80cm
2x =7.6 m
Area required
qall ( net )  20t / m 2  200kPa,
Pu  1.3( Ps )  1.3(2000)  2600kN
Ps 2000  103
Ag    10 m 2
 7.6 *1.8
qall ( net ) 200  10 3

Pu  2600 103
qu    190  103 Pa  190kPa
A 7.6 *1.8
Check for punching Shear
d = 730 mm

1.13m

0.765
A
bo  2(765)  1130  2260mm
fc ' 25
 VC   bo d  0.75   730  2260 / 1000  2062.3kN
3 3
  d f '  30  730  25
 VC    2  s  c bo d  0.75 2     730  2260 / 1000  6027kN
 b  12  2260  12

VU  800(1.3)  1.13 * 0.765 *190  875.8kN  Vc oK


B
bo  4 (730  400)  4520mm
fc ' 25
 VC   bo d  0.75   730  4520 / 1000  4124.4kN
3 3
  s d  fc '  40  730  25
 VC    2   bo d  0.75 2    730  4520 / 1000  13322.5kN
 b  12  4520  12

VU  1200(1.3)  1.13 *1.13 *190  1317.4kN  Vc oK


Draw S.F.D & B.M.D
Stress under footing
= 190 *1.8 = 342 kN/m
Check for beam shear
b = 1800mm, d = 730mm

25
 VC  0.75   730  1800 / 1000  821.25kN
6
Max.  VU at d from column face  762.34kN
VU  VC
Bending moment Long direction

 ve M  1366kN .m
b  1800mm, d  730mm
25  2 106 *1366 
  0.85 * 1 - 1 -   0.0039
420  0.9 0.85 25 * 730 *1800 
2

AS  0.0039  730 1000  2847mm2  28.5cm 2 use 9 20 / m Top

 ve M  246.7kN .m
b  1800mm, d  730mm
25  2 106 * 246.7 
  0.85 * 1 - 1 -   0.0007   min
420  0.9 0.85 25 * 730 *1800 
2

AS min  0.0018 800 1000  1440mm 2  14.4cm2 use 716 / m Bottom


Bending moment Short direction

Under Column A
2
1040 0.765  1.8  0.4 
M     141.6
(1.8 * 0.765) 2  2 
b  765mm, d  730mm
25  2 106 *141.6 
  0.85 * 1 - 1 -    min
420  0.9 0.85 25 * 730 * 765 
2

AS min  0.0018  800  765  1101.6mm 2  11cm 2 use 714 / m


Under Column B
2
1560 1.13  1.8  0.4 
M     212.33
(1.8 *1.13) 2  2 
b  1130 mm, d  730mm
25  2  106 * 212.33 
  0.85 * 1 - 1 -    min
420  0.9 0.85 25 * 730 *1130 
2

AS min  0.0018  800  765  1101.6mm 2  11cm 2 use 714 / m

Shrinkage Reinforcement in short direction


AS min  0.0018 800  765  1101.6mm2  11cm 2 use 714 / m
Footing Design
Part III
Combined footing, strip footing, & Mat foundatio
Example 2
Design a combined footing As shown

qall ( net )  18 t / m 2  180kPa f c  25 N mm 2 f y  420 N mm 2


Dimension calculation
The base dimension to get uniform distributed load
1950kN
kN 1200 kN 750
750(4.2)+1200(0.2)=1950
A (x)
x1=0.2m
x2=4.2 x = 1.75m
x m

 B1  2 B2  L
x   
 B1  B2  3
Area required
qall ( net )  20t / m 2  200kPa,
Ps 1950 103
Ag    10. 8 m 2

qall ( net ) 180 103


 B1  B2 
  L  10.8
 2 
 B1  B2 
 4.35  10.8
 2 
 B1  B2 
   2.5
 2 
B1  B2  5
 B  2 B2  L  5  B2  4.35
x   1    
B
 1  B 2  3  5  3
1.75  1.45  0.29 B2
B2  1m Pu 1.31950 103
qu    235 103 Pa  235kPa
B1  4 m A 10.8
Check for punching Shear
h= 750mm
d = 732 mm

A B2=1m

bo  2(732)  1065  2590mm B1=4m

fc ' 25
 VC   bo d  0.75   665  2590 / 1000  2160.4kN
3 3
  d f '  30  665  25
 VC    2  s  c bo d  0.75 2     665  2590 / 1000  5222kN
 b  12  2590  12

VU  1200(1.3)  1.065 * 0.733 * 235  1376.6kN  Vc oK


B

bo  2(633)  965  2231 mm


fc ' 25
 VC   bo d  0.75   665  2231 / 1000  1854.5kN
3 3
  sd  fc '  30  665  25
 VC    2   bo d  0.75 2    665  2231 / 1000  5273kN
 b  12  2231  12

VU  800(1.3)  0.965 * 0.633 * 235  896.5kN  Vc oK


Draw S.F.D & B.M.D
Empirical S.F.D & B.M.D

975  0.70  682

Convert trapezoidal load to rectangle


1560  (0.70)  1092
wave  235  23 (940  235)  705
Mmax
705 3.65
2 2
wl
 M max    1174 kN .m
8 8

Clear distance between column


B in moment design = ave. width = 2.5m
Check for beam shear
d = 665mm
b  1  2( Lx )  y
at x  0.815  0.15
1  2( 04.965
.35 )  1.5  1.7 m  1700 mm

25
 VC  0.75   665  1700 / 1000  696kN
6
Max.  VU at d from column B face ( the most critical)  668kN
VU  VC
Y=1.5m b

x 1m

4m
Bending moment Long direction
Top
b  1  2( 24..25
35 )  1.5  2.60m  2600
 ve M  1260kN .m
d  730mm
25  2 10 6 *1260 
  0.85 * 1 - 1 -   0.003
420  0.9 0.85 25 * 665 * 2600 
2

AS  0.003  665  1000  1995mm 2  20cm 2 use 1016 / m Top

Bottom

AS min  0.0018 750 1000  1350mm 2  13.5cm2 use 914 / m Bottom


Bending moment Short direction
Under Column A

b'  1  2( 34..62
35 )  1.5  3.5m  3500mm

b'  1  2( 04.633
.35 )  1.5  1.44m  1440mm

3.5  4
b m  3.75m  3750mm
2
2
1560 0.733  3.75  0.4 
M     583.6
(3.75 * 0.733) 2  2 
d  665mm
25  2 106 * 583.57 
  0.85 * 1 - 1 -   0.005
420  0.9 0.85 25 * 665 * 733 
2

AS  0.005  665  733  3325mm 2  33cm 2 use 10 20


Under Column B

1.44  1
b m  1.22m  1220mm
2

2
975 0.633  1.22  0.3 
M     84.6
(1.22 * 0.633) 2  2 
b  633mm, d  665mm
25  2  10 6 * 84.6 
  0.85 * 1 - 1 -    min
420  0.9 0.85 25 * 665 * 633 
2

AS min  0.0018  750  633  854.6mm 2  8.6cm 2 use 614

Shrinkage Reinforcement in short direction


AS min  0.0018  1000  750  1350mm 2  13.5cm 2 use 914 / m
Reinforcement details
Example 3 (Strip footing)
Design a combined footing As shown

qall ( net )  20t / m 2  200kPa f c  25 N mm 2 f y  420 N mm 2


Dimension calculation
The base dimension to get uniform distributed load
3040kN
kN 800 kN 1280 kN 960

A
Assume
L1=0.6 x1=5.2m L2
x2=10.7m
x

800(0.6)+1280(5.1)+960(10.6)=
3040 (x)
x = 5.65m,
2(x)=11.3m
L2=11.3 - (10.6)=0.7
qall ( net )  18t / m 2  180kPa,
Ps 3040 103
Ag    16.9 m 2
 11.3m 1.8m
qall ( net ) 180  10 3

Pu 1.3 3040 103


qu    195 103 Pa  195kPa
A 11 .3 1.8
Check for punching Shear
h = 700 mm
d=630mm

Example

B
bo  4(630  400))  4120mm
fc ' 25
 VC   bo d  0.75   630  4120 / 1000  3244.5kN
3 3
  s d  fc '  40  630  25
 VC    2   bo d  0.75 2    630  4120 / 1000  6584kN
 b  12  4120  12

VU  1280(1.3)  1.032 *195  1457.1kN  Vc oK

You can check other columns


Draw S.F.D & B.M.D Stress under footing
= 195 *1.8 = 351 kN/m
Check for beam shear
b = 1800mm, d = 630mm

25
 VC  0.75   630 1800 / 1000  708.75kN
6
Max.  VU at d from column face  0.7(1009)  706.3kN
VU  VC
Bending moment Long direction

 ve M  1366kN .m
b  1800mm, d  730mm
25  2 106 *1365 
  0.85 * 1 - 1 -   0.0053
420  0.9 0.85 25 * 630 *1800 
2

AS  0.0053 630 1000  3362mm 2  33.6cm 2 use 9 22 / m Top

 ve M  246.7 kN .m
b  1800mm, d  730mm
25  2  106 * 81 
  0.85 * 1 - 1 -    min
420  0.9 0.85 25 * 730 *1800 
2

AS min  0.0018 700  1000  1260mm 2  12.6cm2 use 814 / m Bottom

Design Short direction as example 1 (lecture 11)


Reinforcement details
Mat Foundation
Check for punching Shear
General Example, Ref. 2

Modified load
General reinforcement details

You might also like