Using DA2000P iMCS will integrate all system onboard ship for control and monitor through
two or more display for the entire ship system to be more cost effective from individual monitoring
system, less equipment, more space available and easy for troubleshooting
Example below
Scope of Monitoring Sys Cummins MCS DA2000P iMCS Scope of Monitoring Sys
(SSM) (SCS)
20000 PROPULSION GROUP
Propulsion Propulsion
•M/Engine & Gearbox (Kobelt) – RM166,500 •3 x M/Engine, Gearbox, Shafting, Exhaust Flap
•Shafting – RM37,462.00 RM272,791.30
•Exhaust Flap – RM35,440.00
SUPPORT SYSTEM
Auxiliary (KD JERONG) Auxiliary
•Fire Detection & Alarm Sys – RM10,000.00 •Tank Level Indicator – RM19,365.08 (optional)
•Fuel Tank Level Sys – RM11,500.00 •Bilge Alarm Sys - RM18,615.14 (optional)
•Bilge Water Level – RM14,950.00 •Fire Fighting Alarm Sys – RM17,998.52 (optional)
(Total: RM36,450.00) (Total: RM55,978.74)
Note:
Total (RM) RM797,266.30 RM572,210.41 SCS price based on new system (KD YU, KD PARI and
KD PAUS)
DA2000P iMCS
Not integrated, consist of few stand alone system All system (Propulsion main engine, Gearbox, Shaft,
Exhaust flap, Generator, Alternator, Switchboard
and RCS) onboard ship are integrated together for
monitoring and control as ONE STOP CENTER.
Dedicated to Cummins engine Compatible with all type engines
Refer to Cummins policy Guarantee of 15 year of equipment availability and
upgrade on any component being obsolete with
new component .
May required oversea support on some issue Locally developed, Not required oversea technical
support
DA2000P iMCS
Limited number of IO. Scalable to integrate with other system without any
hardware modification .
NOT INTEGRATED USING DA2000P RCS will monitor through DA2000P iMCS.
Required shutdown while replacing the IO module Input – Output card is hot swappable . Not required to
shutdown the system for fault card replacement. Online
replacement.
Has difficulty to replace the component and All three ships can share the DA2000P components with out
required to open the wiring termination. required software configuration and disturbed wiring
termination.
Not provided Shaft RPM can be monitor locally at engine room.
DA2000P iMCS
Required Navigation and time consuming in order DA2000P application use friendly with out required time
to search on demand parameters. consuming for searching on demand parameters
Possibility of having grey area for onboard system Less grey area for onboard system integration executed by
integration executed by few developer one developer.
Selected few input –output list are monitored. Most of Main propulsion engine data are monitor. Please
Please refer to Input-Output list from Cummins. refer to ECU input-output list.
Required few display panel to monitor the Required one display monitor panel at bridge for the entire
propulsion system only. Please refer to Cummins. systems onboard ship.
CUMMINS KD SERANG DA2000P iMCS
Generators 3
Not included Nos ( Engine
and
Alternator)
Switch board
Not included
monitoring
CUMMINS KD SERANG DA2000P iMCS
Shaft Plummer
block
Not included temperature for
all main engine
Your Thinking Company
Developing Solution Together
THANK YOU