Distributed Power System

Introduction

Distributed Power System (DPS) is a new generation power solution that


specialized for compact site. It consists of DC module, AC module & battery
module. It supports pole-mounted  and wall-mounted. DPS can be widely used for
macro site, small cell and remote RRU.
DPU40D: DC module, converts AC/HVDC to -48V DC, supplies 3 branches of
DC output and 1 branch for battery
DBU20B & DBU50B: battery module, provides reliable backup energy

Features

 Simple Deployment
DC Load Scenario
• Fast installation, 1 hour by 1 person

• Multiple input modes: AC/HVDC (DPU30D & DPU40D)

 Easy O&M

• Mobile APP (based on Bluetooth), NetEco

• Fan-free design, 4-6 years routine maintenance-free

 Reliable Power Supply

• Lithium iron battery, IP65, working temperature -40ºC to +55ºC

Scenarios

 RRU/AAU remote site

 Easy Macro Site

 LampSite

 AtomCell (hot-spot / blind-spot coverage)

 Enterprise telecom scenario


Specifications
DPS Solution for DC Load Scenarios
Product Type DPU40D-N06A3 DBU20B-N12A3 DBU50B-N12A1
400 mm × 300 mm × 60
Dimension
mm(excluding umshields 420 mm × 300 mm × 120 mm 420 mm × 300 mm × 120 mm
(H×D×W)
and panel)

Weight ~7.5 kg ~20 kg ~26 kg

Installation Mode Wall-mounted, pole-mounted, tower installation

Rated Power 1)
2000 W 2200 W/960 Wh 3000 W/2400 Wh

Parallel Number 4 8 8

System Cabling Mode Bottom inlet and outlet

Protection Level IP65

Working - 40ºC to +55ºC(without solar radiation)


Temperature - 40 to +55ºC(with 1120 W/m^2 solar radiation)

Cooling Mode Natural heat dissipation

Operating
Class C*
Environment2)

Grid Environment3) 1st/ 2nd/ 3rd rate grid*

Storage Transportation: -40ºC to 60ºC; Transportation: -40ºC to 60ºC;


-40ºC to +70ºC
Temperature4) Storage: 0ºC to 40ºC Storage: 0ºC to 40ºC
Environme
nt Operating Humidity 5% to 95% (non-condensing)

Altitude -60 to 4000 m (From 2000~4000m, each 200m increases in altitude will decrease the working temperature by 1℃)

220 V AC single-phase
Power Input Mode 110 V AC dual-live wire -48 V DC -48 V DC
HVDC

AC: 85 - 300 V AC
Power Input Voltage -48 V DC -48 V DC
HVDC: 85 - 400 V DC
Input
Input Frequency 45 Hz - 65 Hz NA NA

AC Input 1× 16 A NA NA

AC SPD 20 kA/20 kA, 8/20 µs NA NA

Output Power 2000 W 2200 W 3000 W

Output Voltage -48 Vdc /57 Vdc selfadaption


Load
DC Output 3×40 A 2×80A battery ports 2×80A battery ports
Output
Battery Branch 1x40 A NA NA

DC SPD 10 kA/20 kA, 8/20 µs

Maximum efficiency not less


Efficiency Efficiency NA NA
than 96%

Communic 1× DB9 ( CAN )


1× DB15 ( CAN+ 4× ALM + 2 × RJ45 (CAN) 2 × RJ45 (CAN)
ation Interface Definition
RS485 ) Internal communication Internal communication
Interface MBUS communication5)
Remark:
1. Affected by the external environment factors, such as temperature and duration of transportation and storage, the rated capacity may fluctuate by ±5%

2.Operating environment definitions:


Class C-Sea environments or outdoor land environments (with simple shielding measures) near pollution sources. If a site is near a pollution source, it is
at most 3.7 km away from salt water such as the sea and salt lakes, 3 km away from heavy pollution sources such as smelteries, coal mines, and thermal
power plants, 2 km away from medium pollution sources such as chemical, rubber, and galvanization industries, or 1 km away from light pollution
.
sources such as packing houses, tanneries, and boiler rooms.
Class D-Environments within 500 m away from the seashore. Class D environments are special Class C environments

3.Grid classification standard:


1st rate grid: power outage < 10hrs per month; 2nd rate grid: power outage < 10hrs per week; 3rd rate grid: power outage 2-8hrs per day

4.The recommended storage temperature is 20ºC to 30ºC, battery life would be reduced if stored in high temperature (The recharging interval should be
12 months under the condition of storage temperature < 30ºC, and 8 months under the condition of 30ºC < storage temperature < 40ºC).

5.RS485 interface supports telecom protocol/ModBus, surpport NetEco / U2000


Internal Communication: DPS supports in-band communication with 5 th generation Huawei RRU.

Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved. HUAWEI TECHNOLOGIES CO., LTD.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Huawei Industrial Base
General Disclaimer Bantian Longgang
The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, Shenzhen 518129, P.R. China
future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed
or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei Tel: +86-755-28780808
may change the information at any time without notice.
www.huawei.com