The document summarizes the working principles of an O2 analyzer and oxygen analyzer. The O2 analyzer uses IR or UV sources to pass rays through a sample cell, with a pyroelectric detector measuring the concentration which corresponds to measured SOx or NOx. An oxygen analyzer uses a zirconium oxide sensor in a probe format, which exhibits high resistance at room temperature but becomes conductive when heated, producing a voltage proportional to oxygen concentration in process air using reference gas.
The document summarizes the working principles of an O2 analyzer and oxygen analyzer. The O2 analyzer uses IR or UV sources to pass rays through a sample cell, with a pyroelectric detector measuring the concentration which corresponds to measured SOx or NOx. An oxygen analyzer uses a zirconium oxide sensor in a probe format, which exhibits high resistance at room temperature but becomes conductive when heated, producing a voltage proportional to oxygen concentration in process air using reference gas.
The document summarizes the working principles of an O2 analyzer and oxygen analyzer. The O2 analyzer uses IR or UV sources to pass rays through a sample cell, with a pyroelectric detector measuring the concentration which corresponds to measured SOx or NOx. An oxygen analyzer uses a zirconium oxide sensor in a probe format, which exhibits high resistance at room temperature but becomes conductive when heated, producing a voltage proportional to oxygen concentration in process air using reference gas.
• The IR or UV sources will be used in the analyzer. It passes the IR or UV
rays through a sample cell. • A Pyroelectric detector is used to measure the concentration of these IR or UV rays and the output of the detector is equivalent to the measured Sox or Nox. • Other than non-dispersive UV or IR, So2 can also be measured by UV fluorescence, Enhanced Laser, Fourier Transform Infra-red, gas chromatography, mass spectrometry. Oxygen analyser Oxygen analyser • The Zirconium oxide sensor usually is furnished in a convenient probe format for direct-in-line insertion. The sensor is based on the zirconium oxide is the conductor of oxygen ion. The Zirconium exhibits very high resistance at room temperature. • Heating the element allows different partial oxygen concentration of gases to come into contact with opposite of the zirconia, creating an oxygen concentration cell. An electromotive force is produced because ions travel through the zirconia element to the other element. Oxygen analyser • At high temperature the zirconia becomes conductive.The zirconia is heated and the gas with known concentration is filled inside the meter which is the reference gas. At an optimum temperature, a voltage is produced across the zirconium cell, which is proportional to the concentration of oxygen in the process air or which is dependent only on the ratio of the concentration of the oxygen. • Using air as the reference gas, the current produced will be the measure of the concentration of oxygen in the process gas only. Oxygen analyser
Handbook of Fluorescent Gems and Minerals - An Exposition and Catalog of the Fluorescent and Phosphorescent Gems and Minerals, Including the Use of Ultraviolet Light in the Earth Sciences