You are on page 1of 106

HUAWEI - OptiX OSN 6800

Hardware Description

MALDONADO, Sebastian
30 – November - 2012
Index
1 – Cabinet
1.1 Cabinet Structure.
1.2 Configuration of the integrated Cabinet.
1.3 Specifications.

2 – Subrack
2.1 Structure.
2.2 Technical specification of the Subrack.
2.3 Slots Description.
2.4 FAN Area.
2.5 PIU.
2.6 Data Communication and Equipment Maintenance Interfaces.

3 – Optical Transponder Unit


3.1 LSX
3.2 TMX

2 Proprietary and Confidential


Index
4 – Line Unit
4.1 ND2.
4.2 NS2.

5 – Tributary Unit
5.1 TOM.
5.2 TDX.

6 – Optical Multiplexer and Demultiplexer Unit.


6.1 M40.
6.2 M40V.
6.3 D40.
6.4 FIU

7- Optical Add and Drop Multiplexing Unit


7.1 MR8.

3 Proprietary and Confidential


Index
8 – Sistem Control and Comunication
8.1 SCC.

9 – Cross- Conect Unit


9.1 XCS.

10- Links

11- Referencias

4 Proprietary and Confidential


1 - Cabinet
1.1 Cabinet Structure

• The OptiX OSN 6800 has hardware such as cabinet, subrack, DCM
frame and board.

• OptiX OSN 6800 has independent power supply

• The main frame of the ETSI 300 mm rear column


cabinet is a rack with a door fixed at the front, a rear
door with air vents fixed at the back and movable side
doors at both sides.

6 Proprietary and Confidential


1.2 Caonfiguration of the Integrate Cabinet
• The ETSI cabinets can be of two heights respectively.
Cabinets of different types can be configured with different
quantity of OptiX OSN 6800 subracks.

Full configuration of cabinets of different heights.

7 Proprietary and Confidential


1.3 Specifications
• The specifications of the integrated cabinet include
dimensions, weight, maximum power, voltage, and so
on.

Technical specifications of the two types of cabinets.

8 Proprietary and Confidential


2 - Subrack
2.1 Structure
• 1 - Indicators: They indicate the
running status and alarm status of
the subrack.

• 2 - Board area: All service boards


are in this area. Totally 21 slots are
available.

• 3 - Fiber cabling area: Fiber


jumpers from the ports on the front
panel of the boards are routed to
the area before reaching the
matched side of the cabinet. The
mechanical VOA is also installed in
this area.

10 Proprietary and Confidential


2.1 Structure
• 4 - Fan tray assembly: This area
contains 10 fans for ventilation and
heat dissipation of the subrack.

• 5 - Air filter: It protects the subrack


from outside dust in the air. It needs
to be taken out and cleaned
periodically.

• 6 - Fiber spool: The fiber spool


serves to coil the extra fibers. Fixed
fiber spools are on two sides of the
subrack. The fibers whose extras 7 - Mounting ears: They fix the
are coiled in the fiber spool on the
cabinet side enter another subrack.
subrack in the cabinet.

11 Proprietary and Confidential


2.2 technical specification of the subrack
• Subrack characteristics:

12 Proprietary and Confidential


2.3 Slots Description
• The board area of the subrack has 21 slots, defined as IU1 to IU21
from left to right.

• IU1-IU18 are for service boards.


• IU21 is for the AUX.
• IU19 and IU20 are for the PIU.
• IU18 is for the active SCC.
• IU17 is available for the standby
SCC or the other service boards.
• IU9 is available for the active
XCS or for the other service
boards.
• IU10 is available for the standby Slots of the subrack.
XCS or for the other service
boards.

13 Proprietary and Confidential


2.4 FAN Area
• In the OptiX OSN 6800 system, each subrack has a fan area. A fan area
consists of fan tray assembly and air filter. The air filter can be drawn
out and be cleaned.

Appearance of a fan area.

14 Proprietary and Confidential


2.5 PIU
• The OptiX OSN 6800 is configured with two PIU boards. The two
boards provide power s upplies to the system with 1+1 hot backup.

• Indicators
• There is one indicator on the front panel.
Running status indicator (RUN) – green

• Interface
There is only one power interface on the front panel
of the PIU board. The interface is used to access the
DC power from -38.4 V to -72 V.

• Valid Slots
The PIU occupies one slot. The valid slots for the PIU are IU19 and
IU20.

15 Proprietary and Confidential


2.6 Data Communication and Equipment
Maintenance Interfaces.
• The OptiX OSN 6800 provides abundant interfaces for data communication
and equipment maintenance.

16 Proprietary and Confidential


2.6.1 Interfaces in the Interface area.
• The interface area provides functional interfaces such as management
interface, inter-subrack communication interface, alarm output and
cascading interface, alarm input and output interface.

• The interface area is behind the indicator panel in the upper part of the
subrack.

17 Proprietary and Confidential


2.6.2 Interface on the Front Panel of the AUX Board

• The AUX board provides NM interface, NM cascading interface, inter-


subrack normal and emergent communication interface.

18 Proprietary and Confidential


3 - Optical Transponder Unit

19
LSX
• The LSX is a type of optical transponder unit, serving to map one
channel of 10 Gbit/s service signals into OTU2 or OTU2v signals and
realizing the conversion between the 10 Gbit/s service signal and the
ITU-T Recommendation-compliant.

20 Proprietary and Confidential


LSX – Signal Flow
• The LSX board consists of the client-side optical module, WDM-side optical
module, signal processing module, control and communication module, and
power supply module.

21 Proprietary and Confidential


LSX – Front Panel
• Indicators
There are four indicators on the front panel.
1) Board hardware status indicator (STAT) - dual-colored (red, green)
2) Service active status indicator (ACT) - green
3) Board software status indicator (PROG) - dual-colored (red, green)
4) Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

22 Proprietary and Confidential


LSX - Specifications of Optical Module at the Client
Side

23 Proprietary and Confidential


LSX - Specifications of Optical Module at the Client
Side

24 Proprietary and Confidential


LSX - Specifications of Optical Module at the Client
Side

25 Proprietary and Confidential


TMX
• The TMX is a type of optical transponder unit. The TMX multiplexes
four STM-16/OC-48/ OTU1 service signals into one OTU2 signal. It also
realizes conversion between these signals and ITU-T
Recommendation-compliant WDM signals.

26 Proprietary and Confidential


TMX – Signal Flow
• The TMX board consists of the client-side optical module, WDM-side
optical module, signal processing module, control and
communication module, and power supply module.

27 Proprietary and Confidential


TMX – Front Panel
• Indicators
There are four indicators on the front panel.
• Board hardware status indicator (STAT) - dual-colored (red, green)
• Service active status indicator (ACT) - green
• Board software status indicator (PROG) - dual-colored (red, green)
• Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

28 Proprietary and Confidential


TMX - Specifications of optical module at the client
side

29 Proprietary and Confidential


TMX - Specifications of optical module at the client
side

30 Proprietary and Confidential


TMX - Specifications of optical module at the client
side

31 Proprietary and Confidential


4 – Line Unit

32
ND2
• The ND2 is a type of line unit. The ND2 realizes the conversion
between eight cross-connect ODU1 signals or two cross-connect
ODU2 signals and the ITU-T Recommendation-compliant WDM OTU2
signals.

33 Proprietary and Confidential


ND2 – Signal Flow
• The ND2 board consists of the WDM-side optical module, OTN
processing module, control and communication module, and power
supply module.

34 Proprietary and Confidential


ND2 – Front Panel
• Indicators
There are four indicators on the front panel.
1- Board hardware status indicator (STAT) - dual-colored (red, green)
2- Service active status indicator (ACT) - green
3- Board software status indicator (PROG) - dual-colored (red, green)
4- Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

35 Proprietary and Confidential


ND2 - Specifications of Optical Module at the DWDM
Side

36 Proprietary and Confidential


ND2 - Specifications of Optical Module at the DWDM
Side

37 Proprietary and Confidential


ND2 - Specifications of Optical Module at the DWDM
Side
• Mechanical Specifications
• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2.2 mm (T)
• Dimensions of front panel: 264.6 mm (H) x 25.4 mm (W)
• Weight: 3.53 lb (1.6 kg)

• Power Consumption

• The maximum power consumption at 25Ž: 68.0 W


• The maximum power consumption at 55Ž: 74.8 W

38 Proprietary and Confidential


NS2
• The NS2 is a type of line unit. The NS2 realizes the conversion
between four cross-connect ODU1 signals or a ODU2 electrical signal
and the ITU-T Recommendation-compliant WDM OTU2 signals.

39 Proprietary and Confidential


NS2 – Signal Flow
• The NS2 board consists of the WDM-side optical module, signal
processing module, control and communication module, and power
supply module.

40 Proprietary and Confidential


NS2 – Signal Flow

41 Proprietary and Confidential


NS2 – Front Panel
• Indicators
There are four indicators on the front panel.
1) Board hardware status indicator (STAT) - dual-colored (red, green)
2) Service active status indicator (ACT) - green
3) Board software status indicator (PROG) - dual-colored (red, green)
4) Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

42 Proprietary and Confidential


NS2 - Specifications of Optical Module at the DWDM
Side

43 Proprietary and Confidential


NS2 - Specifications of Optical Module at the DWDM
Side

44 Proprietary and Confidential


5 - Tributary Unit
TOM
• The TOM can be used in six different application scenarios. In
different application scenarios, eight pairs of optical interfaces of the
TOM can be used as client-side interfaces or WDM-side interfaces. The
maximum access capacity of the TOM at the client side is 10 Gbit/s.

46 Proprietary and Confidential


TOM – Signal Flow
• The TOM board consists of the client-side optical module, WDM-side
optical module, signal processing module, control and
communication module, and power supply module.

47 Proprietary and Confidential


TOM – Front Panel
• Indicators
There are four indicators on the front panel.
1- Board hardware status indicator (STAT) - dual-colored (red, green)
2- Service active status indicator (ACT) - green
3- Board software status indicator (PROG) - dual-colored (red, green)
4- Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

48 Proprietary and Confidential


TOM - Specifications of Optical Module at the DWDM
Side

49 Proprietary and Confidential


TOM - Specifications of Optical Module at the DWDM
Side

50 Proprietary and Confidential


TOM - Specifications of Optical Module at the DWDM
Side
• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2 mm (T)


• Dimensions of front panel: 264.6 mm (H) x 25.4 mm (W)
• Weight: 2.43 lb (1.1 kg)

• Power Consumption

• The maximum power consumption at 25℃: 55.0 W


• The maximum power consumption at 55℃: 60.0 W

51 Proprietary and Confidential


TDX
• The TDX is a type of tributary unit. The TDX realizes the conversion
between two 10GE LAN/ 10GE WAN/STM-64/OC-192 optical signals
and eight 2.5Gbit/s ODU1 virtual concatenation electrical signals /two
10Gbit/s ODU2 electrical signals through cross-connection.

52 Proprietary and Confidential


TDX – Signal Flow
• The TDX board consists of the client-side optical module, signal
processing module, control and communication module, and power
supply module.

TN11TDX

53 Proprietary and Confidential


TDX – Signal Flow

T
TN12TDX
54 Proprietary and Confidential
TDX – Front Panel
• Indicators
There are four indicators on the front panel.
1) Board hardware status indicator (STAT) - dual-colored (red, green)
2) Service active status indicator (ACT) - green
3) Board software status indicator (PROG) - dual-colored (red, green)
4) Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

55 Proprietary and Confidential


TDX - Specifications of Optical Module at the Client
Side

56 Proprietary and Confidential


TDX - Specifications of Optical Module at the Client
Side

57 Proprietary and Confidential


TDX - Specifications of Optical Module at the Client
Side

58 Proprietary and Confidential


TDX - Specifications of Optical Module at the Client
Side
• Mechanical Specifications

Dimensions of
• Dimensions of front panel: 264.6 mm (H) x 25.4 mm (W)
• Weight
• l TN11TDX: 2.75 lb (1.25 kg)
• l TN12TDX: 3.09 lb (1.40 kg) board (PCB): 245.1 mm (H) x 220 mm (D) x 2
mm (T)

59 Proprietary and Confidential


6 - Optical Multiplexer and Demultiplexer Unit

60
M40
• The M40 is a type of optical multiplexer unit. The M40 realizes the
multiplexing of a maximum of 40 ITU-T Recommendation-compliant
WDM signals into one fiber.

61 Proprietary and Confidential


M40 – Signal Flow
• The M40 board consists of the optical module, detection and
temperature control module, control and communication module, and
power supply module.

62 Proprietary and Confidential


M40 – Front Panel
• Indicators
There are four indicators on the front panel.
1- Board hardware status indicator (STAT) - dual-colored
(red, green)
2- Service active status indicator (ACT) - green
3- Board software status indicator (PROG) - dual-colored
(red, green)
4- Service alarm indicator (SRV) - triple-colored
(red, green, yellow)
• Interfaces

63 Proprietary and Confidential


M40
• The M40V is a type of optical multiplexer unit. The M40V realizes the
multiplexing of a maximum of 40 ITU-T Recommendation-compliant
WDM signals into one fiber and adjusts the input optical power of
each channel.

64 Proprietary and Confidential


M40 - Optical Specifications

65 Proprietary and Confidential


M40 - Optical Specifications
• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2 mm (T)


• Dimensions of front panel: 264.6 mm (H) x 76.2 mm (W)
• Weight: 4.84 lb (2.2 kg)

• Power Consumption

• The maximum power consumption at 25℃: 20.0 W


• The maximum power consumption at 55℃: 22.0 W

66 Proprietary and Confidential


M40V – Signal Flow
• The M40V board consists of the optical module, detection and
temperature control module, control and communication module, and
power supply module.

67 Proprietary and Confidential


M40V – Signal Flow
Each of the M01-M40 optical interfaces receives one channel of single-wavelength
optical signals, and sends the signals to the multiplexer after the optical power
adjustment by VOA. The multiplexer multiplexes the 40 channels of single-
wavelength optical signals into one channel of multiplexed optical signals, and
then output them through the OUT optical interface.

68 Proprietary and Confidential


M40V – Front Panel
• Indicators
There are four indicators on the front panel.
1) Board hardware status indicator (STAT) - dual-colored (red, green)
2) Service active status indicator (ACT) - green
3) Board software status indicator (PROG) - dual-colored (red, green)
4) Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

69 Proprietary and Confidential


M40V - Optical Specifications

70 Proprietary and Confidential


M40V - Optical Specifications
• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2 mm (T)


• Dimensions of front panel: 264.6 mm (H) x 76.2 mm (W)
• Weight: 5.06 lb (2.3 kg)

• Power Consumption

• The maximum power consumption at 25℃: 38.5 W


• The maximum power consumption at 55℃: 42.3 W

71 Proprietary and Confidential


D40
• The D40 is a type of optical demultiplexer unit. The D40 realizes the
demultiplexing of one optical signal into a maximum of 40 ITU-T
Recommendation-compliant WDM signals.

72 Proprietary and Confidential


D40 –Signal Flow
• The D40 board consists of the optical module, detection and
temperature control module, control and communication module, and
power supply module.

73 Proprietary and Confidential


D40 – Front Panel
• Indicators
There are four indicators on the front panel.
1- Board hardware status indicator (STAT) - dual-colored (red, green)
2- Service active status indicator (ACT) - green
3- Board software status indicator (PROG) - dual-colored (red, green)
4- Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

74 Proprietary and Confidential


D40 - Optical Specifications

75 Proprietary and Confidential


D40 - Optical Specifications
• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2 mm (T)


• Dimensions of front panel: 264.6 mm (H) x 76.2 mm (W)
• Weight: 4.84 lb (2.2 kg)

• Power Consumption

• The maximum power consumption at 25℃: 20.0 W


• The maximum power consumption at 55℃: 22.0 W

76 Proprietary and Confidential


FIU
• The FIU is a type of optical multiplexer and demultiplexer unit. The FIU
realizes the multiplexing and demultiplexing of the signals transmitted
by the main optical path and the optical supervisory channel.

77 Proprietary and Confidential


FIU – Flow Signal
• The FIU board consists of the optical module, optical power detection
module, control and communication module, and power supply
module.

78 Proprietary and Confidential


FIU – Front Panel
• Indicators
There are four indicators on the front panel.
1- Board hardware status indicator (STAT) - dual-colored (red, green)
2- Service active status indicator (ACT) - green
3- Board software status indicator (PROG) - dual-colored (red, green)
4- Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

79 Proprietary and Confidential


FIU - Optical Specifications

80 Proprietary and Confidential


FIU - Optical Specifications
• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2 mm (T)


• Dimensions of front panel: 264.6 mm (H) x 25.4 mm (W)
• Weight: 2.2 lb (1.0 kg)

• Power Consumption

• The maximum power consumption at 25℃: 4.2 W


• The maximum power consumption at 55℃: 4.6 W

81 Proprietary and Confidential


7 - Optical Add and Drop Multiplexing
Unit
MR8

• The MR8 is a type of optical add and drop multiplexing unit.


The MR8 realizes the adding/dropping and multiplexing of eight
signals.

83 Proprietary and Confidential


MR8 – Signal flow
• The MR8 board consists of the OADM optical module, control and
communication module, and power supply module.

84 Proprietary and Confidential


MR8 – Signal Flow
• Signal Flow

• The IN interface receives the multiplexed signals sent from the


upstream station. The drop optical module separates eight
wavelengths from the signals and these eight wavelengths are
transmitted to the OTU boards or integrated client-side equipments
through the D1 to D8 interfaces. The rest wavelengths are transmitted
to other OADM equipment through the MO interface.

• The MI interface receives the signals transmitted by the main path.


The signals are multiplexed with eight wavelengths added through the
A1 to A8 interfaces by the add optical module. Then, the multiplexed
signals are transmitted through the OUT interface.

85 Proprietary and Confidential


MR8 – Front Panel
• Indicators

There is one indicator on the front panel.


Board hardware status indicator (STAT) –
dual-colored (red, green)

• Interfaces

86 Proprietary and Confidential


MR8 - Optical Specifications

87 Proprietary and Confidential


MR8 - Optical Specifications

88 Proprietary and Confidential


MR8 - Optical Specifications

• Rules of Adding/Dropping Wavelength

89 Proprietary and Confidential


MR8 - Optical Specifications

• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2


mm (T)
• Dimensions of front panel: 264.6 mm (H) x 50.8 mm (W)
• Weight: 2.20 lb (1.0 kg)

• Power Consumption

• The maximum power consumption at 25℃: 0.2 W


• The maximum power consumption at 55℃: 0.3 W

90 Proprietary and Confidential


8 - System Control and Communication
SCC
• The SCC is a type of system control and communication unit. Working
with the network management system to manage each board, the SCC
realizes the communications between equipments.

• The main functions and features supported by the SCC are DCC
communication, subrack cascading, clock and power supply backup.

• The SCC board consists of the overhead processing module, clock


module, monitoring module, communication module, CPU and control
module, and power supply module.

92 Proprietary and Confidential


SCC – Signal Flow

93 Proprietary and Confidential


SCC – Front Panel
• Indicators
There are eight indicators on the front panel.
1- Board hardware status indicator (STAT) - dual-colored (red, green)
2- Service active status indicator (ACT) – green
3- Board software status indicator (PROG) - dual-colored (red, green)
4- Service alarm indicator (SRV) - triple-colored (red, green, yellow)
5- System power supply indicator (PWRA)- dual-colored (red, green)
6- System power supply indicator (PWRB)- dual-colored (red, green)
7- Protection power indicator (PWRC)- dual-colored (red, green)
8- Alarm cut-off indicator (ALMC)- yellow
• Buttons

94 Proprietary and Confidential


SCC – Front panel
• LED

• Interfaces

The SCC does not provide external interfaces.

95 Proprietary and Confidential


SCC - Specifications of the SCC
• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2 mm (T)


• Dimensions of front panel: 264.6 mm (H) x 25.4 mm (W)
• Weight: 2.64 lb (1.2 kg)

• Power Consumption

• The maximum power consumption at 25℃: 30.0 W


• The maximum power consumption at 55℃: 33.0 W

96 Proprietary and Confidential


9 - Cross- conect Unit
XCS
• Two functional versions of the XCS board are available: TN11 and TN12.
The main difference between the two versions lies in the cross-connect and
grooming capacity.

98 Proprietary and Confidential


XCS – Signal Flow
• The XCS board consists of the cross-connect module, control and
communication module, and power supply module.

99 Proprietary and Confidential


XCS – Front Panel
• Indicators
There are four indicators on the front panel.
1- Board hardware status indicator (STAT) - dual-colored (red, green)
2- Service active status indicator (ACT) - green
3- Board software status indicator (PROG) - dual-colored (red, green)
4- Service alarm indicator (SRV) - triple-colored (red, green, yellow)

• Interfaces

The XCS does not provide external interfaces.

10 Proprietary and Confidential


0
XCS - Specifications of the XCS
• Mechanical Specifications

• Dimensions of board (PCB): 245.1 mm (H) x 220 mm (D) x 2 mm (T)


• Dimensions of front panel: 264.6 mm (H) x 25.4 mm (W)
• Weight:
• TN11XCS: 2.20 lb (1.0 kg)
• TN12XCS: 2.65 lb (1.2 kg)

10 Proprietary and Confidential


1
10 – Links
Links
• Pico Truncado – Río Gallegos
• Campana – San Vicente
• Corrientes – Asunción
• Córdoba – Santa Fé
• Guaymallén – Santiago de Chile
• Río Gallegos – San Gregorio

10 Proprietary and Confidential


3
11 – References
References
• 01.01.04.01.03 – OptiX OSN 6800 Hardware Description (V100R004_01)
• CAPITULO 1- Cabinet
• CAPITULO 2- Subrack
• CAPITULO 5- Optical Transponder Unit
• CAPITULO 6- Tributary Unit and Line Unit
• CAPITULO 7- Cross-connect Unit
• CAPITULO 8- Optical Mulpitplexer and Demultiplexer Unit
• CAPITULO 9- Optical Add and Drop Multiplexing Unit
• CAPITULO 10- Reconfigurable Optical Add and Drop Multiplexing Unit
• CAPITULO 13- Optical Supervisory Channel Unit

10 Proprietary and Confidential