Professional Documents
Culture Documents
ID:
180201062
180201041
Characteristics of Single Loaded Corridor:
• Normally used in low rise
• buildings Grid comes from its working space and structural needs
• Rooms are located at the one side of the corridor to get natural light and ventilation
• The staircase may be located at one or both end or at the center of the building
• The maximum distance from one staircase to another should be within 100‘
• Construction system usually load bearing or columns
• The bays are restricted to 20' to control the depth of the beams and floor to floor height
•The width of the corridor depends on the traffic load
• In a linear building the expansion joint should be neary 150'
1. National Case Study
Liberation War Museum
Vistara Architects
Ground Floor Plan
Internatinal Case Study
Aomori Contemporary Art Center
Architect: Tadao Ando
Double Loaded Corridor Type Building :
A building design in which there are apartments or other individual
units on both sides of a passage corridor .
It is better to limit the number of apartments off one double loaded corridor.
Other things to consider include:
•windows at the end of the corridor to let in light and air, and allow views out
•extra space around lifts and circulation areas, to form lobbies where people can
meet
•extra width and height in the corridor, particularly around doorways, to give a
feeling of spaciousness
•using an atrium in a building with a deep plan. This can let in light to the middle
of the building.
Double loaded corridor in apartment building
T here is the potential to resolve solar access for otherwise unfavourably faced
units on a single or double-loaded corridor by way of using double height,
sometimes referred to as "up-and-over", apartments.
These will effectively be a two level apartment, and the living level will have
windows on both sides.
Advantage and disadvantages of double loaded corridor:
Advantage of double loaded corridor: Disadvantages of double loaded corridor:
greater efficiency of circulation space compared to Double loaded corridor buildings will almost always
a single loaded corridor suffer from poor solar access
higher overall density of residential units, which Double loaded corridor buildings can’t provide cross
may be required in city or district center locations ventilation.
where good public transport links and amenities.
the potential for double-fronted buildings on sites May have to use wind breakers for ventilation in
where this is appropriate high-rise buildings
Buildings with a staircase/ elevator core serving When more than two units are served by one such
two units per storey can enjoy full solar access and core, the use of sun and wind in space conditioning
cross ventilation becomes difficult
opportunity for more variety in apartment mix due although the ratio of exposed envelope to floor
to greater building depth area per unit becomes smaller.
American International School (AISD/D)
(Local)
CLIENT: AISD
ARCHITECT: Bashirul Haq
PROJECT COMPLETION: 1992
An extension of the school
BUILD AREA: 43208 sft
for secondery school
Structural detail
Conclusion:
• When more than two units are served by one such core, the use of sun and wind in
space conditioning becomes difficult
• although the ratio of exposed envelope to floor area per unit becomes smaller.
• Double loaded corridor buildings can’t provide cross ventilation.
• Double loaded corridor buildings will almost always suffer from poor solar access
https://www.google.com/search?
q=findings+of+double+loaded+corridor&oq=findings+of+double+loaded+corridor&aqs=chrome..69i57j33i22i29i30
l8.7129j0j7&sourceid=chrome&ie=UTF-8
Reference
https://www.google.com/search?
q=findings+of+double+loaded+corridor&oq=findings+of+double+loaded+corridor&aqs=chrome..69i57j33i22i29i30
l8.7129j0j7&sourceid=chrome&ie=UTF-8
Thank you