You are on page 1of 87

ZXUN CSCF Data Configuration

Contents

 Basic Operation of the OMM System


 Configuring Foreground Public Data
 Configuring Home Office Data
 Configuring SIP Protocol Data
 Configuring Diameter Protocol Data
 Configuring Digit Analysis Data
Logging in OMM Client
 Operation maintenance system adopts client/server
architecture, which provides remote/local access system
means.
Client adopts straightforward IE browser for login and
operation.
Steps 1. Based on the IP address, user name and
password
configured during NM server software installation, input
login address
in the browser, for example:
http://10.44.117.140:2323/cscf_1/client/.
Logging in OMM Client
Logging in OMM Client
 2. Input User Name and Password, and then click
the OK button to enter ZXUN CSCF Local
Management Terminal interface.
Entering Command Terminal Interface
 Enter command terminal interface through WEB
client and query related command trees, enter
related commands for operations.
Running Commands
 In command terminal interface of WEB client, enter comma
nd and command parameter in command input area, run re
lated command and finally query the result.
Searching Commands
 If only the key words of command are acquired, it’s able to
search for the entire commands in command terminal
interface and view related help information.
Importing and Running Batch Commands
 It’s inefficient to enter commands one by one or
there are mass commands for running, command
terminal provides batch command running means.
If batch commands are saved as TXT or MML
files, it’s able to import and run this file in
command terminal for high efficiency.
Importing and Running Batch Commands
Contents

 Basic Operation of the OMM System


 Configuring Foreground Public Data
 Configuring Home Office Data
 Configuring SIP Protocol Data
 Configuring Diameter Protocol Data
 Configuring Digit Analysis Data
Configuring Foreground Public Data
 Table of Contents:
 Physical Configuration
 Save Operations
 Configuring Protocol Stack
Physical Configuration
 Run this command to enter physical configuration.
Steps 1. Enter command mode of physical configuration by
running GOTO PHYSICS command.
Physical Configuration
 This topic mainly introduces the steps to configure rel
ated NEs, including fixing NE type.If NEs share one s
helf, it’s required to configure all the NE numbers.
Steps 1. Add a NE by ADD NE command.
Physical Configuration
Physical Configuration
 This topic introduce the steps to configure a ZXUN
CSCF rack based on on-site device quantity. It’s
possible to add multiple racks by manual commands.
Steps 1. Add a ZXUN CSCF rack by ADD RACK
command.
Physical Configuration
Physical Configuration
 This topic introduces the steps to add a shelf
for the corresponding rack. One rack can be
configured with 2 shelves at most. For ATCA
platform, No.2 shelf is control shelf, therefore, if
there is only one shelf, shelf number must be
2.
Steps 1. Add a ZXUN CSCF shelf by ADD SHELF
command.
Physical Configuration
Physical Configuration

 This topic introduces the steps to configure ZXUN


CSCF module and plan module number and server
set number based on IGSU quantity and functions.
Steps 1. Add ZXUN CSCF module by ADD
RACKVIEWMODULE command.
Physical Configuration
Physical Configuration

 IP dispatch data is applied to message distribution of


multiple modules. Generally, it's only required to
configure IP address and port number of UDP and
SCTP protocol.
Steps 1. Add ZXUN CSCF IP dispatch data by ADD
IPDISPV4 command.
Physical Configuration
Save Operations
 It's required to save the configuration in
Configuration Management> Public Data
Configuration.
Steps 1. After configuring public data, save the data
by SAVE command.
Save Operations
Configuring Protocol Stack

 This topic introduces the steps to enter protocol stack


configuration mode.
Steps 1. Enter protocol stack configuration mode by
GOTO PROTOCOL command.
Configuring Protocol Stack
Configuring Protocol Stack
 This topic introduces the steps to enter interface configurati
onmode for IP interface configuration after querying related
IP Interface information, including real address configuratio
n and virtual address configuration. Enter real interface for
configuring real address, or enter virtual interface for config
uring virtual address.
Steps 1. Enter interface configuration mode by INTERFAC
E command.
Configuring Protocol Stack
Configuring Protocol Stack
 This topic introduces the steps to configure IP address and
after querying related network interface information. Enter
real interface for configuring real address, or enter virtual
interface for configuring virtual address.
Steps 1. Command result prompts entering the
configuration mode of this IP interface successfully, it's
able to configure IP address for this interface by ADD IP
ADDRESS command.
Configuring Protocol Stack
Contents

 Basic Operation of the OMM System


 Configuring Foreground Public Data
 Configuring Home Office Data
 Configuring SIP Protocol Data
 Configuring Diameter Protocol Data
 Configuring Digit Analysis Data
Configuring Home Office Data
 Table of Contents
 Configuring NE Functional Properties
 Configuring Module Capacity
 Configuring Host
 Configuring Relations Between IP and Host
 Configuring a Domain
 Configuring an Adjacent Host
Configuring Home Office Data
 Table of Contents
 Configuring Entrance Policy
 Configuring Visiting Network
 Configuring a Service Group
Configuring NE Functional Properties

 This topic introduces the steps to configure the logical


functional entity of current NE, including P-CSCF, I—
CSCF and S-CSCF.
Steps 1. Configure NE functional property by SET
CSCFTYPE command.
Configuring NE Functional Properties

 网元属性图
Configuring Module Capacity

 This topic introduces the steps to configure various


data area capacity of current NE module, including
user capacity and related data area capacity of SIP
protocol.
Steps 1. Add module capacity by ADD MODCAPA
command.
Configuring Module Capacity

 模块容量图
Configuring Host

 This topic introduces the steps to configure host


number, host name and host type of current NE.
Steps 1. Add host by ADD HOST command.
Configuring Host

 主机配置图
Configuring Relations Between IP and Host

 This topic introduces the steps to configure host IP


address of current NE, which is realized by
configuring relations between host ID and IP address.
Steps 1. Add host IP address data by ADD HOSTIP
command.
Configuring Relations Between IP and Host
Configuring a Domain
 This topic introduces the steps to configure the
domain of current NE, including domain name, toll
area code, country code and service group ID.
Steps 1. Add a domain by ADD DOMAIN command.
Configuring a Domain
Configuring an Adjacent Host
 This topic introduces the steps to configure the
adjacent host name of current NE, host SIPURI,
domain name and adjacent host type.
Steps 1. Add a adjacent host by ADD ADJHOST
command.
Configuring an Adjacent Host
 邻接主机图
Configuring Entrance Policy

 All SIP messages enter ZXUN CSCF domain, firstly,m


atch entrance policy according to sub-net and sub-net
mask of source SIP message, and then obtain service
groups of entrance and other related policies. Adding
entrance policy includes sub-net and sub-net mask co
nfiguration.
Steps 1. Add an entrance policy by ADD ENTPLC co
mmand.
Configuring Entrance Policy
 入口策略图
Configuring Visiting Network

 Visiting network flag is to identify current P-CSCF NE


and network registered by the user, check whether
users are roaming by forwarding to HSS by signaling,
and check whether it's allowed to register on current
NE.
Steps 1. Add visiting network ID by ADD VISTNET
command.
Configuring Visiting Network

 拜访网络图
Configuring a Service Group
 This topic introduces the steps to associate route
selector with related policies, for instance, entrance
policy associated with service group of entrance
policy, and exit policy associated with service group of
domain.
Steps 1. Add a service group by ADD SVCGRP
command.
Configuring a Service Group
 业务群
Contents

 Basic Operation of the OMM System


 Configuring Foreground Public Data
 Configuring Home Office Data
 Configuring SIP Protocol Data
 Configuring Diameter Protocol Data
 Configuring Digit Analysis Data
Configuring SIP Protocol Data
 Table of Contents
 Configuring UDP Connection
 Configuring an SIP Link
 Configuring SIP Signaling Route
 Configuring SIP Signaling Route Set
 Configuring an SIP Access Address
Configuring UDP Connection
 Adding a UDP connection means UDP connection
information of SIP protocol, including connection ID,
name, peer IP address and peer ports.
Steps 1. Add UDP connection by ADD UDPCONN
command.
Configuring UDP Connection
 UDP 承载
Configuring an SIP Link
 This topic introduces the steps to add link number,
bearer protocol type, connection ID and link name of
SIP protocol, and adjacent host ID.
Steps 1. Add an SIP link by ADD SIP CSCFLIN
command.
Configuring an SIP Link
 SIP 链路
Configuring SIP Signaling Route

 This topic introduces the steps to configure NE


signaling route interconnected with this NE by SIP
protocol, mainly includes SIP link selection policy and
shared SIP link number.
Steps 1. Add an SIP signaling route configuration by
ADD SIP CSCFROUTE command.
Configuring SIP Signaling Route
 SIP 路由
Configuring SIP Signaling Route Set

 This topic introduces the steps to configure NE


signaling route set interconnected with this NE by SIP
protocol, mainly including SIP route selection policy
and shared route number.
Steps 1. Add SIP signaling route set by ADD SIP
CSCFROUTESET command.
Configuring SIP Signaling Route Set
 Sip 路由集
Configuring an SIP Access Address
 This topic introduces the steps to configure IP
address/SIP port of the interconnected NE by SIP
protocol.
Steps 1. Add SIP access address by ADD SIP
CSCFACCADDR command.
Configuring an SIP Access Address
 SIP 接入地址
Contents

 Basic Operation of the OMM System


 Configuring Foreground Public Data
 Configuring Home Office Data
 Configuring SIP Protocol Data
 Configuring Diameter Protocol Data
 Configuring Digit Analysis Data
Configuring Diameter Protocol Data
 Table of Contents
 Entering SIGTRAN Configuring Mode
 Configuring SCTP Association
 Configuring Global Diameter Information Disposal
Module
 Configuring a Diameter Link
 Configuring a Diameter Route
Entering SIGTRAN Configuring Mode
 This topic introduces the steps to enter SIGTRAN
configuration mode and perform related SIGTRAN
configuration, including adding SCTP SIGTRAN.
Steps 1. Enter SIGTRAN configuration mode by
GOTO SIGTRAN;.
Entering SIGTRAN Configuring Mode
 SIGTRAN 模式
Configuring SCTP Association
 This topic introduces the step to add SCTP basic
connection and configure information of this
connection.
Steps 1. Add basic SCTP connection by ADD
SCTPAC command.
Configuring SCTP Association
 SCTP 欧联
Configuring Global Diameter Information
Disposal Module
 This topic introduces the steps to configure
global diameter information disposal module.
The module number for adding global NE must
be identical with NE module number.
Steps 1. Add global diameter information
disposal module by ADD DIA
GLOBALREGISTRY command.
Configuring Global Diameter Information
Disposal Module
 DIAMETER 全局处理模块
Configuring a Diameter Link
 This topic introduces the steps to configure a
Diameter link, including configuring CSCF and HSS
which adopts Diameter protocol, fixing bearer protocol
and SCTP association.
Steps 1. Add a DIAMETER link by ADD DIAMETER
LINK command.
Configuring a Diameter Link
 Diameter 链路
Configuring a Diameter Route
 This topic introduces the steps to configure a diameter
route It's required to configure a RELAY route and a
LOCAL route.
Steps 1. Add a DIAMETER route by ADD DIAMETER
ROUTE command.
Configuring a Diameter Route
Contents

 Basic Operation of the OMM System


 Configuring Foreground Public Data
 Configuring Home Office Data
 Configuring SIP Protocol Data
 Configuring Diameter Protocol Data
 Configuring Digit Analysis Data
Configuring Digit Analysis Data
 Table of Contents
 Configuring Route Selector
 Configuring URI Digit Analysis
 Configuring TEL Digit Analysis
 Configuring IP Analysis
Configuring Route Selector

 This topic introduce the steps to add a route selector


for adding IP/URI/TEL analysis data.
Steps 1. Add a route selector by ADD RTSEL
command.
Configuring Route Selector
Configuring URI Digit Analysis

 This topic introduces the steps to add URI analyzed


digit.
Perform route analysis according to route selector,
SIP URI, SIP methods and finally fix running related
service.
Steps 1. Add URI analyzed digit by ADD URIANA
command.
Configuring URI Digit Analysis
Configuring TEL Digit Analysis
 This topic introduces the steps to add TEL analyzed
digit.
Perform route analysis according to route selector,
TEL digit, SIP methods and finally fix running related
service.
Steps 1. Add TEL analyzed digit by ADD TELANA
command.
Configuring TEL Digit Analysis
Configuring IP Analysis
 This topic introduces the steps to add IP analysis.
Perform route analysis according to route selector, IP
address, SIP methods and finally fix running related
service.
Steps 1. Add IP analysis by ADD IPANA command.
Configuring IP Analysis