You are on page 1of 18

Overview AGS20

Solutions

Rizzo Ivan
Network Engineering
AGS20
Capacity and Configurations

2
AGS20 1+0 and 1+1 Configuration
AGS20 1+0 Configuration

ƒ1 AGS20 - ASNK ODU Net Throughput [Mbps]


  7 MHz 14 MHz 28 MHz 40 MHz 56 MHz
4QAMs 9 18 36 51 72
4QAM 11 21 43 61 86
16QAMs 18 36 73 102 145
16QAM 21 43 84 117 168
32QAM 25 51 105 146 207
AGS20 1+1 Configuration 64QAM 30 64 132 185 262
128QAM 36 76 157 219 311
ƒ1 256QAM 42 88 180 253 359
512QAM 47 98 200 282 400
1024QAM 52 107 224 315 446
2048QAM --- 111 234 332 472

All rights reserved © SIAE


MICROELETTRONICA
AGS20 2+0 Configuration – L1 Link Aggregation
ƒ1 ƒ2

2+0 Single Pol with Hybrid*


*only ODUs belonging to same sub-band

ƒ1 DP

2+0 XPIC
AGS20 QUAD IF 4+0 Configuration SB ODUs – L1 Link Aggregation
ƒ
• L1 Link Aggregation on
4 IF Directions
• Balanced Hybrid
(4dB+4dB of losses)
• ODUs with isolator
belonging to same sub-
band Standard Power
L1 Link Aggregation • For U6 GHz also HP
on 4 IF Directions ODUs wide band
available
• With XPIC no 2048QAM
and no 7MHz allowed
AGS20 QUAD IF 4+0 Configuration Narrow Filter ODUs– L1 Link Aggregation - 1

• L1 Link Aggregation on 4
ƒ
IF Directions
• Multicirculator
(2.5dB+2.5dB of losses)
• Narrow Filter HP ODUs
• Available only at U6 GHz
and 7GHz

L1 Link Aggregation
on 4 IF Directions
AGS20 QUAD IF 4+0 Configuration Narrow Filter ODUs– L1 Link Aggregation - 2

• One AGS20 QuadIF IDU


• One Dual Pol Antenna
ƒ • L1 Link Aggregation on 4 IF
Directions
• Multicirculator (2.5dB+2.5dB
of losses)
• Narrow Filter HP ODUs
• Two ODUs on each
multicirculator and two
adapted loads on the free
ports
• XPIC configuration
• System easily expandable up
to 8+0 configuration by
adding one IDU QUAD IF
and 4 ODUs on each site
• Available only at U6 GHz and
7 GHz
• With XPIC no 2048QAM and
L1 Link Aggregation
no 7MHz allowed
on 4 IF Directions
4x(1+1) Space Diversity and XPIC Configuration
• Two AGS20 QuadIF IDU
Main Diversity
D Antenna
• Two Dual Pol Antenna
Antenna
P D • L1 Link Aggregation on 4 IF
P Directions
V H
8
8 V H • Multicirculator (2.5dB+2.5dB
8
8 of losses)
7
7
• Narrow Filter HP ODUs
7
7
• Two ODUs on each
multicirculator and two
adapted loads on the free
ports
• XPIC configuration
• Diveristy Protection against
multipath fading
8V M, 8H M, 8V D, 8H D • Solution recommended for
AGS20 QUAD IF long hops in rural/flat aeres
AGS20 QUAD IF

7V M, 7H M, 7V D, 7H D

8
AGS20 QUAD IF 8+0 Configuration Narrow Filter ODUs– L1 Link Aggregation on each IDU

• Two AGS20 QuadIF


• One Dual Pol Antenna
• Up to 3.5GBps capacity
DP
• L1 Link Aggregation on 4 IF
Directions, on each IDU
• Multicirculator (2.5dB+2.5dB
V H of losses)
5
5 6
6 • Narrow Filter HP ODUs
• XPIC configuration
7 •
7
8
Available only at U6 GHz and
8
7 GHz
• With XPIC no 2048QAM and
no 7MHz allowed

AGS20 QUAD IF

AGS20 QUAD IF
8x(1+1) Space Diversity and XPIC Configuration
• Four AGS20 QuadIF
Main Diversity
D Antenna
• Two Dual Pol Antenna
Antenna
P D • Same capacity of the 8+0
P • L1 Link Aggregation on 4 IF
5 V H
6 5 6 V H Directions, on each IDU
5
6 5 6 • Multicirculator (2.5dB+2.5dB
7
7
of losses)
8 8
7
7
• Narrow Filter HP ODUs
8 8
• XPIC configuration
• Diveristy Protection against
multipath fading
• Solution recommended for
long hops in rural/flat aeres

5V M, 5H M, 5V D, 5H D 8V M, 8H M, 8V D, 8H D
AGS20 QUAD IF AGS20 QUAD IF

6V M, 6H M, 6V D, 6H D 7V M, 7H M, 7V D, 7H D
AGS20 QUAD IF

AGS20 QUAD IF
10
AGS20 Protection Configurations – 2x(1+1) HSB XPIC

ƒ
• One AGS20 QuadIF
• One Dual Pol Antenna
DP
• Hardware protection on the
ODUs: 1+1 HSB configuration
f1V
f1V • XPIC frequency re-use
configuration
• Link capacity equal to 2+0
f1H f1H
configuration
AGS20 Protection Configurations – 2x(1+1) Space Diversity XPIC

• One AGS20 QuadIF


DP • One Dual Pol Antenna
• Hardware and Multipath
Fading protection: 1+1 Space
f1V Diversity configuration
DP • XPIC frequency re-use
f1H configuration
• Link capacity equal to 2+0
f1V
configuration

f1H
AGS20 4+0 Configuration
Hybrid vs Multicirculator

13
AGS20 4+0 Hybrid vs Multicirculator
Hybrid Multicirculator

VS
4+0 Multicirculator
 High Power ODU: +3dB respect to the Standard Power ODU (@256QAM 27dBm
vs 24dBm)
 Narrow Filter ODU: single channel ODU (one different CODE for each channel)
 Multicirculator: Capability to branch up to 4 co-polar channels. Low circulation
losses: 2.5dB on each side (i.e. 5dB on the total Link Budget)
 Channels Deployment: two copolar channels in XPIC, on the remaining ports of
the multibranching will be installed an adapted load. High Flexibility in the channel
deployment.
 Scalability: this system can be expanded to 8+0 by adding four ODUs and one
AGS 4IF IDU

15
4+0 HP Sub-band ODU + Hybrid
 High Power ODU: 2dB respect to the Standard Power ODU
 Sub Band ODUs (with isolator): one ODU support more than one channel
according to the SIAE sub bands
 Hybrid: Capability to branch 2 co-polar channels belonging to the same sub band.
Higher Circulation Losses: 3.5dB to 4dB on each side (i.e. 8dB on the total Link
Budget)
 Channels Deployment: two copolar channels in XPIC
 Scalability: this system cannot be expanded. To realize the 8+0 solution the
existing ODUs must be replaced by new HP-NF ODU and the hybrid must be
replaced by the multibranching.

16
4+0 Standard Power ODU + Hybrid
 Standard Power ODU: -3dB respect to the HP NF ODU and -2dB respect to HP
SB ODU
 Sub Band ODUs (with isolator): one ODU support more than one channel
according to the SIAE sub bands
 Hybrid: Capability to branch 2 co-polar channels belonging to the same sub band.
Higher Circulation Losses: 3.5dB to 4dB on each side (i.e. 8dB on the total Link
Budget)
 Channels Deployment: two copolar channels in XPIC
 Scalability: this system cannot be expanded. To realize the 8+0 solution the
existing ODUs must be replaced by new HP-NF ODU and the hybrid must be
replaced by the multibranching.

17