Professional Documents
Culture Documents
MÔ PHỎNG VÀ TỐI ƯU NHÀ MÁY LỌC DẦU
MÔ PHỎNG VÀ TỐI ƯU NHÀ MÁY LỌC DẦU
PETROVIETNAM UNIVERSITY
HYSYS SIMULATION
2
2. DISTILLATION
OBJECTIVES
• Column profiles.
PROCEDURE
• Enter 125 Stages and define the feed and product streams as shown below.
3
2. DISTILLATION
• In page 2 will appear. Select Regular Hysys reboiler for Reboiler Type
Selection, and select the Once-through radio button.
•Condenser Pressure and Reboiler Pressure: 300 psig.
•Select Mass for Flow Basis and enter 5000000 lb/day for Liquid Rate.
4
2. DISTILLATION
• Conditions: enter a pressure : 350 psig, a Vapour fraction : 1, and Mass Flow :
7.3e+06 lb/day for the Feed@COL1 stream.
5
2. DISTILLATION
• Compositions : Type a number into the Feed composition grid for Ethane to open
the Input Composition for Stream window. Mass Fractions : 0.315 for Ethane
and 0.685 for Ethylene.
6
2. DISTILLATION
• In the Column → Design | Specs. Make sure that the Distillate Rate value is
correct (9.450e+004 kg/h).
• In the Comp Frac Spec window select the Stream for Target Type,
Ethane@COL1 for Draw, Mass Fraction for Basis, and 9.0e-004 for Spec Value.
Select Ethylene for Components.
→ Converged.
7
2. DISTILLATION
OUTCOME
8
2. DISTILLATION
CONCLUSIONS
• The 125 stage column was able to exceed the specification of 99.96wt%
ethylene at 5 million lb/day, as well as the bottoms having less than 0.10wt%
ethylene.
• It could then be concluded that this column is capable of completing the
desired separation.
9
3. ABSORBER
OBJECTIVES
PROCEDURE
10
3. ABSORBER
• Add a material stream. This will be the flue gas stream. Temperature : 65°C,
Pressure : 1.2 bar, and Mass Flow : 1000 tonne/day. In Composition enter Mole
Fractions : 0.10 for CO2, 0.70 for Nitrogen, 0.15 for Water, and 0.05 for Oxygen.
11
3. ABSORBER
•Add a second material stream. This will be the solvent stream. Temperature :
25°C, a Pressure : 1 bar, and a Mass Flow : 80,000 kg/h. In the Composition enter
12
3. ABSORBER
• Add Absorber Column Sub-Flowsheet from the Model Palette. Open the
Absorber Column Input Expert. On the first page of the input expert select stream
Solvent as the Top Stage Inlet and stream Flue Gas as the Bottom Stage Inlet.
Create an Ovhd Vapour Outlet called Clean Air and a Bottoms Liquid Outlet
called Solution. Enter 20 for Stages.
• On the second page of the input expert enter a Top Stage Pressure of 1 bar and a
Bottom Stage Pressure of 1.2 bar. On the final page of the input expert enter Top
and Bottom Stage Temperature estimates of 50°C. The column property window
will now appear. Run to begin calculations → converge.
13
3. ABSORBER
14
3. ABSORBER
OUTCOME
15
7. ATMOSPHERIC CRUDE COLUMN
16
7. ATMOSPHERIC CRUDE COLUMN
LESSON OBJECTIVES
• Add cut point specifications to increase side product quality and quantity.
17
7. ATMOSPHERIC CRUDE COLUMN
18
7. ATMOSPHERIC CRUDE COLUMN
19
7. ATMOSPHERIC CRUDE COLUMN
20
7. ATMOSPHERIC CRUDE COLUMN
21
7. ATMOSPHERIC CRUDE COLUMN
22
7. ATMOSPHERIC CRUDE COLUMN
23
7. ATMOSPHERIC CRUDE COLUMN
24
7. ATMOSPHERIC CRUDE COLUMN
25
7. ATMOSPHERIC CRUDE COLUMN
EXERCISE 1:
26
7. ATMOSPHERIC CRUDE COLUMN
27
7. ATMOSPHERIC CRUDE COLUMN
28
7. ATMOSPHERIC CRUDE COLUMN
29
7. ATMOSPHERIC CRUDE COLUMN
EXERCISE 2:
30
7. ATMOSPHERIC CRUDE COLUMN
EXERCISE 3:
31
7. ATMOSPHERIC CRUDE COLUMN
32
8. REBOILER
33
8. REBOILER
LESSON OBJECTIVES
• Learn how to calculate heat of vaporization using the heater block in Aspen
HYSYS.
• Understand the impact of heat of vaporization on distillation.
34
8. REBOILER
• E-100
o Enter Worksheet at column Feed-Water enter the parameters Pressure = 100 kPa,
Vapour Fraction = 0, and Molar Flow = 1 kgmole/h.
o Enter Worksheet at column Water-Out enter the parameters Pressure = 100 kPa,
Vapour Fraction = 1.
35
8. REBOILER
• E-101
o Enter Worksheet at column Feed-3MH enter the parameters Pressure = 100 kPa,
Vapour Fraction = 0, and Molar Flow = 1 kgmole/h.
o Enter Composition enter parameters Mole Fraction of 3-methylhexane = 1.
o Enter Worksheet at column 3MH-Out enter the parameters Pressure = 100 kPa,
Vapour Fraction = 1.
36
8. REBOILER
• E-102
o Enter Worksheet at column Feed-1,1,2 enter the parameters Pressure = 100 kPa,
Vapour Fraction = 0, and Molar Flow = 1 kgmole/h.
o Enter Composition enter parameters Mole Fraction of 1,1,2-trichloroethane = 1.
o Enter Worksheet at column 1,1,2-Out enter the parameters Pressure = 100 kPa,
Vapour Fraction = 1.
37
8. REBOILER
RESULTS
38
8. REBOILER
RESULTS
39
8. REBOILER
RESULTS
40
8. REBOILER
CONCLUSIONS
41
8. BLENDING / MIXING
42
8. BLENDING / MIXING
43
8. BLENDING / MIXING
44
8. BLENDING / MIXING
After creating the lines. We proceed to add MIXER.
45
8. BLENDING / MIXING
46
8. BLENDING / MIXING
47
8. BLENDING / MIXING
In the Conditions in the Gasoline column enter Temperature = 25°C, Pressure =
1 bar , Mass Flow = 82.76 kg/h in the Gasoline column
48
8. BLENDING / MIXING
In the Composition in the Gasoline column enter the parameter 224-Mpentane
= 1 in the Gasoline column
49
8. BLENDING / MIXING
50
8. BLENDING / MIXING
Create Spreadsheet
51
8. BLENDING / MIXING
We have the data below.
52
8. BLENDING / MIXING
Enter the spreadsheet according to the instructions, enter A1 and A2
53
8. BLENDING / MIXING
Import variables into B1
54
8. BLENDING / MIXING
Enter the calculation formula B2 = (B1*0.17243)/(1-0.17243).
55
8. BLENDING / MIXING
56
10. CSTR
LESSON OBJECTIVES
57
10. CSTR
58
10. CSTR
• Start simulating with a CSTR from Model Pallette. Then enter stream name
and and parameters for the Reactor as shown in the given pictures.
Start simulating with a CSTR from Model Pallette. Then enter stream
name and and parameters for the Reactor as shown in the given pictures
59
10. CSTR
• After entering enough data the Reactor converges, then we continuously add
adjust to adjust the reactor volume in order to achieve a reaction conversion of
90%with the following information.
60
10. CSTR
• Add a Spreadsheet with the following data. Import variables: B1: the Tank
Volume of CSTR-100, B2: Actual Volume Flow of stream LIQ-Product. In cell
B3 enter the following formula: =(B1/B2)*110.
61
10. CSTR
Conclusion
• From the results received as shown in the picture, we can see Residence Time
to achieve 90% reaction conversion in a CSTR is about 39 minutes.
• Both the analytical solution and design spec in Aspen HYSYS produced the
same required residence time of the same value.
• The residence time for a CSTR is longer than for a batch reactor or PFR
because of the back-mixing: product is mixed in with the feed, slowing the
reaction.
62
11. PFR
LESSON OBJECTIVES
• Use chemical reaction kinetics to calculate the reactor length required to reach
a desired conversion in a plug flow reactor.
• PROCEEDING TO SIMULATE THE PROCESS
63
11. PFR
64
11. PFR
• Start simulating with a PFR from Model Pallette. Then enter stream name and
and parameters for the Reactor as shown in the given pictures.
Start simulating with a PFR from Model Pallette. Then enter stream name
and and parameters for the Reactor as shown in the given pictures
65
11. PFR
• After entering enough data the Reactor converges, then we continuously add
adjust to adjust the reactor volume in order to achieve a reaction conversion of
90%with the following information.
66
11. PFR
67
11. PFR
CONCLUSION
• From the results received as shown in the picture, we can see the required
reactor length to achieve 90% reaction conversion in a PFR is about 8.3 m. This
same strategy can be applied for much more complex reactions and multi - tube
reactors, which would be much more difficult to attempt to solve using hand
calculations.
68
12.INTEGRATION WITH RECYCLE
LESSON OBJECTIVES
69
12.INTEGRATION WITH RECYCLE
• Step 1: Create a component list. Add Ethylene Oxide (C2H4O), Water (H2O) and
Ethylene Glycol to the component list.
• Step 2: Define property package. Select NRTL and then go to Binary Coeffs
tab, select UNIFAC VLE as the Coeff Estimation method to estimate the
missing binary coefficients and press Unknowns Only. This will estimate the
coefficients for the ethylene oxide / ethylene glycol pair.
70
12.INTEGRATION WITH RECYCLE
• Step 3: Go to the Reactions and Add Reaction with the following data.
71
12.INTEGRATION WITH RECYCLE
• Step 4: Attach the reaction to a fluid package. In the Set-1 (Reaction Set) form,
click Add to FP and select Basis- 1.
72
12.INTEGRATION WITH RECYCLE
• Step 6: Start simulating with 2 streams from Model Pallette. Then enter data
with the following information:
73
12.INTEGRATION WITH RECYCLE
• Step 7: Then add a CSTR Reactor and enter the following information.
74
12.INTEGRATION WITH RECYCLE
75
12.INTEGRATION WITH RECYCLE
76
12.INTEGRATION WITH RECYCLE
• Step 8: After entering enough information the Reactor converges and the result
we get is shown in the picture.
77
12.INTEGRATION WITH RECYCLE
• Step 9: Add a Distillation Column and enter data as shown in the pictures.
78
12.INTEGRATION WITH RECYCLE
79
12.INTEGRATION WITH RECYCLE
80
12.INTEGRATION WITH RECYCLE
81
12.INTEGRATION WITH RECYCLE
• Step 13: Reconnect the Water to Reactor stream to the Reactor and the process
converges.
• Step 14: Result received is shown below.
82
12.INTEGRATION WITH RECYCLE
CONCLUSIONS
From the results received as shown in the pictures, we can see that Molar Flowrate
of Water Feed is 50 kgmole/h when Distillate Rate is 100 kgmole/h. The stream
Distillate contains mostly unreacted water. This water can be recycled to the reactor
in order to reduce the feed water requirements (as well as eliminate a waste stream)
83
84