You are on page 1of 28

PROBE AKS Sensors

Data Acquisition Systems

Prepared by: Zaid Al Dulaimi


What is DAS?

 Data Acquisition Systems is the process of sampling signals that measure real
world physical conditions and converting the resulting
samples into digital numeric values that can
be manipulated by a computer

 Types of measured data Temperature. Pressure. Differential pressure. Flow


WHAT YOU WILL RECEIVE

 LOGGERS

 TEMPERATURE SENSORS + ACCESSORIES

 PRESSURE SENSORS + ACCESSORIES

 FLOW METERS + ACCESSORIES

 DIFFERENTIAL PRESSURE SENSORS + ACCESSORIES


LOGGERS (SETUP)

 HOW TO INSTALL

 CHANNEL SELECTION

 FREQUENCY SELECTION
How to install a logger

 Antenna: Secured in a VERTICAL position

 Power: Plug into a 220V power source

 USB: Directly plug into your computer


RF CHANNEL

 Must be a unique number from 1 to 16

 Sensors must match the channel configured on the logger

 Must not match any nearby channel


Frequency selection

4.2gHz 19.2gHz 76.8gHz


Sampling Rate 10s < 5s < 1s <
Battery Life 1 year 8 months 4 months
Obstacle Very minimal Moderate High
interference
Sensors

 Temperature sensors

 Pressure sensors (2.5k, 5k & 10k)psi

 Differential sensors

 Flow meters
Temperature sensors
AKS temperature sensor
(newer model)

AKS temperature sensor Thermowell for


(older model) temperature sensors
Tips upon receival (Temperature sensor)

Once you receive your package, it is recommended to:

 Make sure to clean the thermowell from the inside thoroughly

 Put some EPF oil inside the thermowell before installing it on the sensor

 Check the unit of measurement on your sensor

 Inspect the thread and make sure that it is not damaged


Pressure sensors
Comes in different sizes
according to pressure rating

High pressure fitting


AKS pressure sensor
(older model)
AKS pressure sensor
(newer model)
Tips upon receival (Pressure sensor)

Once you receive your package, it is recommended to:

 Check the unit of measurement on your sensor

 Inspect the thread and make sure that it is not damaged

 Make sure that the fittings have the right pressure rating
Differential pressure sensors
Differential pressure sensors

Make sure the H side


is connected upstream
the orfice
Tips upon receival (Differential sensor)

Once you receive your package, it is recommended to:

 Check the unit of measurement on your sensor

 Inspect the H&L fittings and make sure they are not damaged
Flow meters

Magnetic pickup
Tips upon receival (Flow meter)

Once you receive your package, it is recommended to:

 Check the unit of measurement on your sensor

 Install the magnetic pickup correctly

 Install the clamps on a secure surface to hold the meter safely

 Check the certification by looking up the serial number on emms


MOUNTING CLAMP
Sensor configuration

 RF CHANNEL: Must match the channel set on the logger

 UNIT SELECTION: Must be the correct unit of measurement for the sensor

 BAUD RT: Must match the frequency of the logger

 RF ID: Must be a unique number from 1 to 100 for each sensor

 Sampling rate: The rate at which the data will be transmitted from the sensor
SENSOR CONFIGURATION

For an example, configure a temperature sensor with the following

 Channel =2
 RF = 19.2
 ID = 20
 UNIT = Celsius
SENSOR CONFIGURATION (Channel)

Your sensor is now set on channel 2


SENSOR CONFIGURATION (RF/Radio Frequency)

Your sensor is now set on RF 19.2MHz


SENSOR CONFIGURATION (RF ID/SENSOR ID)

ID number 20 is now set for your sensor


SENSOR CONFIGURATION (UNIT SELECTION)

SENSING UNIT FOR THE SENSOR HAS BEEN SET


SENSOR DIAGNOSIS (LINK TEST)

SENSOR LINK TEST HAS BEEN COMPLETED


SENSOR DIAGNOSIS (Battery voltage)

The brand new battery voltage should be 3.6V.


However, 3.4V-3.6V is also acceptable
If the voltage is below 3.4V, the battery should be replaced
Quick Revision

 What RF should be selected for the longest battery life? 4.2

 Which RF can be interrupted easily by obstacles? 76.8

 After cleaning the thermowell, what is the final step before installing it on
the sensor? Put EPF oil inside the thermowell

 What is the default password on AKS sensors? 0000

 Which RF transmits the data every 1 second? 76.8


ANY QUESTIONS?