You are on page 1of 22

Nokia 2G Parameters

3-03-2020

Prepared By Nishant Gaurav 1


Directed Retry (DR) - 1
DR used to avoid the loss of a call in call-setup if the accessed cell is congested
When no TCH is available in serving cell, TCH can be allocated in an adjacent cell
Mobile Originated (MOC) and Mobile Terminated (MTC) Calls
Target cell entry based on DR Method; TCH
Method 0 - RxLevAccessMin SDCCH
Method 1 - drThreshold
Imperative Handover congested
Candidates ranked based on radio properties.
Steps through candidates (if congested) until MaxTimeLimitDR expires

Queuing can take place in source cell, not in target cell.

Time DR not allowed : improves the reliability of


minTimeLimitDR the measurements of adjacent cells and gives the
queuing process time
Assignment DR allowed
Request maxTimeLimitDR

Prepared By Nishant Gaurav 2


Directed Retry (DR) - 2
Abbreviated name Parameter name Managed Description Range and step Default value
object
With this parameter you disable or enable the external directed retry
handovers. enable external directed retry handovers
(N) (0), disable external directed retry
disableExtDr Disable External DR BSC handovers (Y) (1) 0

With this parameter you define the threshold value of the signal
strength in the adjacent cell for the Directed Retry procedure. If the
signal strength level in the cell is lower than this threshold value,
adjacent cell is not accepted as a candidate in directed retry.

drThreshold Directed Retry Threshold ADCE -110..-47 step 1 -100


With this parameter you define if the directed retry feature is in use
in the cell.
directed retry is not in use (N) (0),
drInUse Directed Retry Used BTS directed retry is in use (Y) (1) 0

With this parameter you define which method is used in directed


retry procedure when candidate cells are evaluated. This parameter
is also used to switch off directed retry method improvements.
Basic directed retry method (0),
drMethod Directed Retry Method BTS Threshold evaluation method (1) 0

With this parameter you define the maximum time period starting
from the assignment request during which the target cell evaluation
for the directed retry handover is allowed.

maxTimeLimitDirectedRetry Max Time Limit Directed Retry BTS 1..15 step 1 5

With this parameter you define the period starting from the
assignment request during which the target cell evaluation for the
directed retry handover is not allowed.

minTimeLimitDirectedRetry Min Time Limit Directed Retry BTS 0..14 step 1 0

Prepared By Nishant Gaurav 3


Dropped Call Control
Call re-establishment
Radio Link Timeout
In case of a Radio Link Failure
A counter is initialized at the value of the
(radioLinkTimeout) within 20 seconds.
radioLinkTimeout
Measurements averaged over 5 seconds for
When SACCH is not correctly received
serving Cell BCCH
Counter decremented by 1
adjacent Cell BCCHs
Strongest is considered
When SACCH correctly received
BCCH data decoded (cell selection param.)
Counter incremented by 2
If
C1 greater than 0, Cell not barred
When counter reaches 0 call is released
Cell belong to selected PLMN,
Call re-establishment allowed
Same behaviour UL and DL
Call re-establishment attempted
Abbreviated name Parameter name Managed Description Range and step Default
object value

With this parameter you define whether call re-establishment is allowed


in the cell.
re-establishment is not allowed (N) (0), re-
callReestablishmentAllowed Call Reestablishment Allowed BTS establishment is allowed (Y) (1) 0
With this parameter you define the maximum value of the radio link
counter expressed in SACCH blocks for non-AMR connections.

radioLinkTimeout Radio Link Timeout BTS 4..64 step 4 20


Prepared By Nishant Gaurav 4
Radio Link
Indoor
Timeout, Call Re-establishment
Outdoor
radioLinkTimeout (default) = 20
Elevator
Tunnel (short)

5. floor radioLinkTimeout = 30 ?

MS MS

1. floor BTS B
Tunnel (long)

BTS A
MS

Unsuccessfull Handover
=> Call Re-Establishment
Prepared By Nishant Gaurav 5
DTX
By enabling this feature, USER can use data while on call

Abbreviated Parameter Managed Description Range and step Default value


name name object

With this parameter you define how the MS uses DTX (discontinuous
transmission).
MS may use DTX (0), MS shall use
dtxMode DTX Mode BTS DTX (1), MS shall not use DTX (2) 2

Prepared By Nishant Gaurav 6


Handover Decision & Priority

Handover process may be triggered by

Quality, field strength or distance values fall below/exceed their threshold


Periodic checks

Handover priority
1. Uplink and downlink Interference
2. Uplink quality
3. Downlink quality
4. Uplink level
5. Downlink level
6. Distance
7. Rapid Field Drop
8. Slow moving MS
9. Better cell i.e. Periodic check (Power Budget HO or Umbrella HO)
10. PC: Lower quality/level thresholds (UL/DL)
11. PC: Upper quality/level thresholds (UL/DL)
Prepared By Nishant Gaurav 7
Power Budget Handover
Trigger

• Periodic Check ( hoPeriodPBGT )


Abbreviated name Parameter name Managed Description Range and step Default Remark
object value
With this parameter you define the interval between power budget
handover threshold comparisons.
Handover Period Power Periodic
hoPeriodPbgt Budget HOC 0..63 step 1 6 Handover
With this parameter you indicate whether the BTS power budget
handover control is enabled.
Enable Power Budget handover control is disabled (N) (0), handover HO Types
enablePowerBudgetHo Handover HOC control is enabled (Y) (1) 1 alowed
With this parameter you define a threshold in the power budget
process. The handover margin prevents repeated handover
between adjacent cells.

hoMarginPbgt HO Margin PBGT ADCE -24..63 step 1 6 Margins


With this parameter you define the minimum signal level of an
adjacent cell, when a handover is allowed to one of them.
Cell area
rxLevMinCell RX Lev Min Cell ADCE -110..-47 step 1 -100 defination
With this parameter you define the maximum transmission power of
the MS for each adjacent cell. This parameter replaces old
ms_txpwr_max_cell parameter.

NOTE:

MML Modification: Online


Cell area
msTxPwrMaxGSM MS Tx Pwr Max GSM ADCE 5..39 step 2 33 defination

Prepared By Nishant Gaurav 8


Handover due to Level
Trigger
Threshold Comparison ( hoThresholdsLevDLNx )

Abbreviated name Parameter name Managed Description Range and step Default Remark
object value

The parameters compare the averaged values of signal strength downlink


measurements for triggering the handover process. Nx: Number of
averages that have to be taken into account when making a handover
decision.

hoThresholdsLevDLNx Threshold Level Downlink Nx HOC 1..32 step 1 1 Thresholds

With this parameter you define a threshold for a handover caused by


signal level.

hoMarginLev HO Margin Lev ADCE -24..24 step 1 3 Margins

With this parameter you define the minimum signal level of an adjacent Cell area
rxLevMinCell RX Lev Min Cell ADCE cell, when a handover is allowed to one of them. -110..-47 step 1 -100 defination

With this parameter you define the maximum transmission power of the MS
for each adjacent cell. This parameter replaces old ms_txpwr_max_cell Cell area
msTxPwrMaxGSM MS Tx Pwr Max GSM ADCE parameter. 5..39 step 2 33 defination

Prepared By Nishant Gaurav 9


Handover due to Quality

Abbreviated name Parameter name Managed Description Range and step Default Remark
object value

With this parameter you define a threshold for a handover caused by


signal quality.

hoMarginQual HO Margin Qual ADCE -24..24 step 1 0 Margins

With this parameter you define the minimum signal level of an adjacent Cell area
rxLevMinCell RX Lev Min Cell ADCE cell, when a handover is allowed to one of them. -110..-47 step 1 -100 defination

With this parameter you define the maximum transmission power of the
MS for each adjacent cell. This parameter replaces old Cell area
msTxPwrMaxGSM MS Tx Pwr Max GSM ADCE ms_txpwr_max_cell parameter. 5..39 step 2 33 defination

Prepared By Nishant Gaurav 10


Handover due to Interference

Abbreviated name Parameter name Managed Description Range and step Default Remark
object value
With this parameter you define the order of preference between
intra-cell and inter-cell handovers when the cause of the handover is
downlink interference. Inter-cell handover has greater priority
HO Preference Order (INTER) (0), Intra-cell handover has greater HANDOV
hoPrefOrderInterfDl Interference DL BSC priority (INTRA) (1) 0 ER
With this parameter you define the order of preference between
intra-cell and inter-cell handovers when the cause of the handover is
uplink interference. Inter-cell handover has greater priority
HO Preference Order (INTER) (0), Intra-cell handover has greater HANDOV
hoPrefOrderInterfUl Interference UL BSC priority (INTRA) (1) 0 ER
With this parameter you indicate whether an intracell handover
caused by downlink interference is enabled. The parameter does not
affect handovers between normal and extended areas.
Enable Intracell Handover handover control is disabled (N) (0), handover Ho Type
enableIntraHoDl Interference DL HOC control is enabled (Y) (1) 1 alowed
With this parameter you indicate whether an intracell handover
caused by uplink interference is enabled. The parameter does not
affect handovers between normal and extended areas.
Enable Intracell Handover handover control is disabled (N) (0), handover Ho Type
enableIntraHoUl Interference UL HOC control is enabled (Y) (1) 1 alowed

Prepared By Nishant Gaurav 11


Fast Moving MS Handling in Macro Cell
Abbreviated name Parameter name Managed Description Range and step Default Remark
object value
With this parameter you define the minimum signal level of an
adjacent cell, when a handover is allowed to an adjacent umbrella Fast
cell. moving
ms in
hoLevelUmbrella HO Level Umbrella ADCE -110..-47 step 1 -47 macro cell
With this parameter you define the limit which is compared with the
identification counter (fast moving MS) in the adjacent cell. If the limit
is exceeded, the call is handed over from the macrocell to the best
microcell.

fastMovingThreshold Fast Moving Threshold ADCE 0..255 step 1 0 Threshold


With this parameter you define the adjacent cell layer in relation to
the active cell. A call can be handed over to the cells that are visible
to the serving cell by adjacency definition. This means the cells of
upper layer, serving layer and lower layer. The adjacent cell layer
definition can be used, for example, in umbrella and power budget
handovers in defining the target cells according to their layer. Not Used (0), Same Layer (1), Upper Layer
adjCellLayer Adjacent Cell Layer ADCE (2), Lower Layer (3) 0 Layering

Adjacent cell layer definition

upper layer (macro)

same layer (serving layer)

lower layer (micro)

N (not in use)
Prepared By Nishant Gaurav 12
Cell Selection in idle mode
• Radio Criteria
C1 = (A - Max(B,0))

• A = Received Level Average - p1


• B = p2 - Maximum RF Output Power of the Mobile Station
• p1 = rxLevelAccessMin Min. received level at the MS required for access to the system
• p2 = msTxPowerMaxCCH Max. Tx power level an MS may use when accessing the system

Abbreviated name Parameter name Managed Description Range and step Default Remark
object value

With this parameter you define the minimum power level an MS has
to receive before it is allowed to access the cell.
cell
rxLevAccessMin Rxlev Access Min BTS -110..-47 step 1 -105 selection

With this parameter you define the maximum transmission power an


MS may use when accessing a CCH in the cell for GSM 900/800
bands.
cell
msTxPwrMaxCCH MS Tx Pwr Max CCH BTS 5..39 step 2 33 selection

Prepared By Nishant Gaurav 13


Cell Re-Selection in idle mode
Abbreviated name Parameter name Managed Description Range and step Default Remark
object value

With this parameter you define the received RF power level


hysteresis for required cell reselection. Cell
reselectio
cellReselectHysteresis Cell Reselect Hysteresis BTS 0..14 step 2 4 n

Normally the cell re-selection is harmless in terms of signalling from the point of view of the Network.
However when the process involves a change in the Location Area the MS will recognize the need for
Location Update. To avoid ping pong effects on the border of a Location Area, an hysteresis is introduced.
MS Moving

LA1 LA2

A = 4 dB
1
B = 6 dB
A BC
C = 8 dB 1 2
A B C 2

Prepared By Nishant Gaurav 14


General BSC Parameters
BSC PARAMETERS

Group Explanation Parameter Name Range DB Default Equation Value


Cell Defination for gsmMacrocellThreshold 5 ... 43 2 43 - 2*(DB value) 39 dBm
multilayer network gsmMicrocellThreshold 5 ... 43 2 43 - 2*(DB value) 39 dBm
dcsMacrocellThreshold 0 ... 36 2 30 - 2*(DB value) 26 dBm
dcsMicrocellThreshold 0 ... 36 3 30 - 2*(DB value) 24 dBm
MSC Ho Disable internal ho disableIntHo Yes / No 0 Yes (1), No (0) No
Number of preferred cells genHandoverRequestMessage 1 ... 16 6 1:1 6
Directed Retry Disable external directed retry disableExtDr Yes / No 1 Yes (1), No (0) Yes
Handover Ho Preference order Interference DL/UL hoPreferenceOrderInterfDL INTER / INTRA 0 Inter(0), Intra (1) INTER
hoPreferenceOrderInterfUL INTER / INTRA 0 Inter(0), Intra (1) INTER
msDistanceBehaviour 0 ... 60, 255 255 0, 1-60 sn., 255 No release
Uplink interference level calculations rxLevBalance 0 … 20 5 1:1 5 dB
Advanced Mulilayer Handling BSC TRHO, upper threshold for BTS load amhUpperLoadThreshold 0 … 100 80 1:1 80%
Dual Band/micro, lower thresh. for BTS load amhLowerLoadThreshold 0 … 100 20 1:1 20%
BSC TRHO, max traffic load of an adj cell amhMaxLoadOfTargetCell 0 … 100 70 1:1 70%
BSC TRHO, guard time for going back to org. cell amhTrhoGuardTime 0 … 120 30 1:1 30 sec.
Half Rate "Opt." Lower limit for FR TCH resources btsLoadDepTCHRate 0 ... 100 100 1:1 100%
Upper limit for FR TCH resources btsLoadDepTCHRate 0 ... 100 0 1:1 0%
Target cell and channel type selection tchRateInternalHO 1 .. 5 1 1 to 5 Actual Rate

Prepared By Nishant Gaurav 15


General BTS Parameters-1
BTS PARAMETERS

Group Explanation Parameter Name Range DB Default Equation


1-BCCH, 2-beyond
BCCH TRX Channel Allocation TRX Priority in TCH Allocation trxPriorityInTCHAlloc 0 ... 2 0 BCCH
notAllowedAccessClasses 0...9, 11...15 0 list
Short Message Service Cell Broadcast smsCBUsed Yes / No 0 Yes (1), No (0)
0-May use, 2-Not
Discontinuous Transmission dtxMode 0 ... 2 1 use DTX
Dropped Call Control cellBarred Yes / No 0 Yes (1), No (0)
radioLinkTimeout 4 ... 64 4 4* (DB value + 1)
Averaging btsMeasAver 1 ... 4 1 1:1
AGCH and Paging channels Blocks for access grant, separated noOfBlocksForAccessGrant 0 ... 7 3 1:1
Number of multiframes between paging noOfMultiframesBetweenPaging 2 ... 9 4 1:1
Location updates allowIMSIAttachDetach Yes / No 1 Yes (1), No (0)
Periodic MS location update timerPeriodicUpdateMS 0 / 0.1 ... 25.5 40 (DB value / 10)
HO control process BTS load threshold btsLoadThreshold 0 ... 100 70 1:1
# of physical info messages during ho maxNumberOfRepetitions 5 ... 35 5 1:1
Cell / System Access Rach controlling maxNumberRetransmission 1, 2, 4 or 7 4 1:1
and RACH numberOfSlotsSpreadTrans 3...12, 14, 16, 20, 25, 32, 50 13 13 -> 25
msMaxDistanceInCallSetup 0 ... 255 255 0..255 (x550m)
emergencyCallRestricted Yes / No 0 Yes (1), No (0)
Cell selection cellReselectHysteresis 0 ... 14 3 2*(DB value)
and Reselection rxLevAccessMin -110 ... -47 8 (DB value) -110
callReestablishmentAllowed Yes / No 0 Yes (1), No (0)
max transmit power msTxPwrMaxCCH *GSM* 5 ... 43 5 43 -2*(DB value)
msTxPwrMaxCCH *DCS* 0 ... 30 0 30 -2*(DB value)
max. transmit pwr for class III mobile powerOffset *DCS only* 0 ... 6 0 2*(DB value)
C2 Reselection cellReselectParamInd Y / N 0 Yes (1), No (0)
cellReselectOffset 0 ... 126 0 2*(DB value)
penaltyTime 20 ... 640 1 20*(DB value)
temporaryOffset 0 ... 70 0 10*(DB value)
cellBarQualify Y / N 0 Yes (1), No (0)

Prepared By Nishant Gaurav 16


General BTS Parameters-2
BTS PARAMETERS

Group Explanation Parameter Name Range DB Default Equation


MS power range max pwr in serving cell minMSTxPower *GSM* 5 ... 43 15 43 -2*(DB value)
minMSTxPower *DCS* 0 ... 36 15 30 -2*(DB value)
msTxPwrMax *GSM* 5 ... 43 5 43 -2*(DB value)
msTxPwrMax *DCS* 0 ... 36 0 30 -2*(DB value)
Interference processing Averaging Period interferenceAveragingProcess 1 ... 32 6 1:1
5 Interference bands for the unallocated TSs boundary0 -110 … FIXED 0 (DB value) -110
boundary1 -110 ... -47 8 (DB value) -110
boundary2 -110 ... -47 13 (DB value) -110
boundary3 -110 ... -47 18 (DB value) -110
boundary4 -110 ... -47 25 (DB value) -110
boundary5 -47 … FIXED 63 (DB value) -110
Min. C/N when allocating a TS cnThreshold 0 ... 63 20 1:1
DR and Intelligent DR Directed Retry drInUse Yes / No 1 Yes (1), No (0)
target cell evaluation is allowed maxTimeLimitDirectedRetry 1 ... 15 5 1:1
target cell evaluation is not allowed minTimeLimitDirectedRetry 0 ... 14 3 1:1
Directed Retry Method drMethod 0 … 1 1 0-basic, 1-thres.
Frequency Hopping Hopping Mode hoppingMode NN / BB / RF Plan NN/BB/RF
hoppingSequenceNumber1&2 0 ... 63 Plan 1:1
maioOffset 0 ... 62 Plan 1:1
measurementBCCHAllocation ADJ / IDLE 1 1-ADJ, 0-IDLE
Extended Cell Radius BTS type DE21/DF12 radiusExtension 0 ... 67 0 1:1
Dual Band multiBandCell Yes / No 1 Yes (1), No (0)
earlySendingIndication Y / N 1 Yes (1), No (0)
# of adjacent cells from other freq. band multiBandCellReporting 0 ... 3 3 1:1
Half Rate Lower limit for FR TCH resources btsLoadDepTCHRate 0 ... 100 100 1:1
FR/HR channel allocation method Higher limit for FR TCH resources btsLoadDepTCHRate 0 ... 100 0 1:1
Target cell and channel type selection tchrateIntraCellHo 0 .. 4 0 List

Prepared By Nishant Gaurav 17


General HOC Parameters-1
Group Parameter Name Range DB Default Equation Value
Averaging adjacent cells averagingWindowSizeAdjCell 1 ... 32 6 1:1 6
numberOfZeroResults 0 ... 7 2 1:1 2
allAdjacentCellsAveraged Yes / No 0 Yes (1), No (0) No
Ho Measurement Averaging Method enaFastAveCallSetup Yes / No 0 Yes (1), No (0) No
enaFastAveHo Yes / No 0 Yes (1), No (0) No
enaFastAvePC Yes / No 0 Yes (1), No (0) No
Minimum Intervals minIntBetweenUnsuccHoAttempt 0 ... 30 3 1:1 3 interval
minIntBetweenHoReq 0 ... 30 5 1:1 5 interval
Periodic Handovers hoPeriodPBGT 0 ... 63 2 1:1 2 SACCH
HoPeriodUmbrella 0 ... 63 63 1:1 63 SACCH
HO types allowed enableIntraHoInterfUL Yes / No 0 Yes (1), No (0) No
enableIntraHoInterfDL Yes / No 0 Yes (1), No (0) No
enablePwrBudgetHandover Yes / No 1 Yes (1), No (0) Yes
enableUmbrellaHandover Yes / No 0 Yes (1), No (0) No
enableMSDistanceProcess Yes / No 0 Yes (1), No (0) No
enableSDCCHHandover Yes / No 0 Yes (1), No (0) No
Averaging windows and weighting values hoAveragingLevDL 1 ... 32 4 1:1 4
weighting 1 ... 3 1 1:1 1
hoAveragingLevUL 1 ... 32 4 1:1 4
weighting 1 ... 3 1 1:1 1
hoAveragingQualDL 1 ... 32 1 1:1 1
weighting 1 ... 3 1 1:1 1
hoAveragingQualUL 1 ... 32 1 1:1 1
weighting 1 ... 3 2 1:1 2
msDistanceAveragingParam 1 ... 32 10 1:1 10
msSpeedAveraging 1 ... 32 4 1:1 4

Prepared By Nishant Gaurav 18


General HOC Parameters-2
Group Parameter Name Range DB Default Equation Value
Thresholds hoThresholdsLevDL -110 ... -47 20 (DB value) -110 - 90 dBm
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
hoThresholdsLevUL -110 ... -47 17 (DB value) -110 - 93 dBm
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
Hopping cells hoThresholdsQualDL 0 ... 7 5 1:1 5
px 1 ... 32 4 1:1 4
nx 1 ... 32 6 1:1 6
Hopping cells hoThresholdsQualUL 0 ... 7 5 1:1 5
px 1 ... 32 4 1:1 4
nx 1 ... 32 6 1:1 6
Non-hopping cells hoThresholdsQualDL 0 ... 7 4 1:1 4
px 1 ... 32 4 1:1 4
nx 1 ... 32 6 1:1 6
Non-hopping cells hoThresholdsQualUL 0 ... 7 4 1:1 4
px 1 ... 32 4 1:1 4
nx 1 ... 32 6 1:1 6
hoThresholdsInterferenceDL -110 ... -47 35 (DB value) -110 - 75 dBm
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
hoThresholdsInterferenceUL -110 ... -47 35 (DB value) -110 - 75 dBm
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
msDistanceHoThresholdParam 0 ... 63 63 1:1 63
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1

Prepared By Nishant Gaurav 19


General POC Parameters-1
Group Parameter Name Range DB Default Equation Value
BTS power control powerCtrlEnabled Yes / No 1 Yes (1), No (0) Yes
Interval powerControlInterval 0 ... 31 1 1:1 1 sec
Step sizes powerIncrStepsize 2,4 or 6 2 2 dB (0), 4dB (1), 6dB (2) 6 dB
powerRedStepsize 2 or 4 0 2dB (0), 4dB (1) 2 dB
rfMaxPowerReduction 0 ... 12 0 2*(DB value) 0 dB
UL signal quality bands pwrDecrLimitBand0 0 ... 38 19 2*(DB value) 38 dB
pwrDecrLimitBand1 0 ... 38 19 2*(DB value) 38 dB
pwrDecrLimitBand2 0 ... 38 19 2*(DB value) 38 dB
pwrDecrQualFactor 0 / 1 1 1:1 1
Base station power range bsTxPwrMin 0 ... 30 7/Plan -2*(DB value) -14 dB
bsTxPwrMax 0 ... 30 0/Plan -2*(DB value) - 0 dB
Averaging windows pcAveragingLevDL 1 ... 32 4 1:1 4 SACCH
weighting 1 ... 3 1 1:1 1
pcAveragingLevUL 1 ... 32 4 1:1 4 SACCH
weighting 1 ... 3 1 1:1 1
pcAveragingQualDL 1 ... 32 1 1:1 1 SACCH
weighting 1 ... 3 1 1:1 1
pcAveragingQualUL 1 ... 32 1 1:1 1 SACCH
weighting 1 ... 3 1 1:1 1

Prepared By Nishant Gaurav 20


General POC Parameters-2
Group Parameter Name Range DB Default Equation Value
Thresholds pcLowerThresholdsLevDL -110 ... -47 23 DB value -110 -87 dBm
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
pcLowerThresholdsLevUL -110 ... -47 20 DB value -110 -90 dBm
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
pcLowerThresholdsQualDL 0 ... 7 3 1:1 3
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
pcLowerThresholdsQualUL 0 ... 7 3 1:1 3
px 1 ... 32 1 1:1 1
nx 1 ... 32 1 1:1 1
pcUpperThresholdsLevDL -110 ... -47 40 DB value -110 -70 dBm
px 1 ... 32 3 1:1 3
nx 1 ... 32 4 1:1 4
pcUpperThresholdsLevUL -110 ... -47 40 DB value -110 -70 dBm
px 1 ... 32 3 1:1 3
nx 1 ... 32 4 1:1 4
pcUpperThresholdsQualDL 0 ... 7 0 1:1 0
px 1 ... 32 3 1:1 32
nx 1 ... 32 4 1:1 32
pcUpperThresholdsQualUL 0 ... 7 0 1:1 0
px 1 ... 32 3 1:1 32
nx 1 ... 32 4 1:1 32

Prepared By Nishant Gaurav 21


General ADJE Parameters

ADJE Parameter - Group Parameter Name Range DB Default Equation Value


enableHoMarginLevQual Yes / No 1 Yes (1), No (0) Yes
trhoTargetLevel -109 ... -47/ N Plan (DB value) -110 Plan
syncronised Yes / No 0 Yes (1), No (0) No
Fast Moving MS in macro cell hoLevelUmbrella -110 ... -47 Plan (DB value) -110 Plan
fastMovingThreshold 0 ... 255 Plan 1 : 1, 0: Not in use Plan
Not used (0)
Same layer (1)
adjCellLayer N/SAME/LOWER/UPPER Plan Plan
Upper layer (2)
Lower layer (3)
Cell area definition rxLevMinCell -110 ... -47 10 (DB value) -110 -100 dBm
msTxPwrMaxCell *GSM* 5 ... 43 5 43 -2*(DB value) 33 dBm
msTxPwrMaxCell *DCS* 0 ... 36 0 30 -2*(DB value) 30 dBm
Priority of the adjacent cell hoPriorityLevel 0 ... 7 3 1:1 3
hoLoadFactor 0 ... 7 2 1:1 1
Margins hoMarginPBGT -24 ... 63 6 1:1 6 dB
hoMarginLev -24 ... 24 3 1:1 3 dB
hoMarginQual -24 ... 24 0 1:1 0 dB

Prepared By Nishant Gaurav 22

You might also like