Step -1 Properties of UHPC – Required for Design SETRA Code;
(Stress-strain curve, creep, shrinkage, Literature review
stress limits etc… Identify critical failure modes. Identify limitations of UHPC. Any additional design parameters? Step -2 Identify a typical design example. Case Study – Need discussion with Say 3 Lanes with footpath (Normal NHAI stakeholders Structures) Choose span length – Based on chosen span – MIDAS/ STAAD a) 56m (already constructed in India) Grillage model (if I Girders are chosen) can b) 80m (Point of interest) be created. Choose Structures System – MIDAS is preferable. c) I Girders – Most preferred d) Box Girder – May not be preferred in usual case due to logistics Choose Structural configurations – From the first principle required e) Flange width, depth of girder, width of configuration shall be justified with web etc… reinforcement and PT requirement. Excel f) Based on Force Demands VB, Python or MATLAB may be used for the programming. Step -3 Critical failure modes shall be investigated 3D FEM model (using 8 node element) in with 3D model. MIDAS for individual girder. For exp., lateral torsional buckling if web is too slender etc… Step -4 Comparison to be made with usual design Typical design of girders and sub-structure practice (Real life example – Actual required. bridge). Say M50 grade of concrete for girders. Grade of Sub-structure and foundation remains the same. In order to show benefits, analysis may be conducted for 4 seismic zone (Seismic zone 2, 3 , 4 and 5). Foundation requirement is important in seismic areas. Step -5 Parametric studies may be conducted for Excel program/ MATLAB/ PYTHON already different grades of UHPC and overall developed in step-2 can be used. savings in construction cost.