You are on page 1of 12

Controls

Anthony Facchin
HARDI Academy
Controls
Controls - Identification

M-70 BK
From 1970 From 1978
Pressure regulation & safety valve = one unit Pressure regulation & safety valve = two units
HARDI-MATIC

Pressure reg. Safety valve HARDI-MATIC pressure reg. Safety valve


Controls - Identification

EVC (Electric Valve Control) EFC (Electric Fast Control)


From 2003 From 2005
With HARDI-MATIC No Pressure Equalisation, Controller needed
No “Main ON/OFF” valve DynamicFluid4 possible
Distribution valves
Distribution valves
Pressure reg.

Pressure reg.
DF4 reg.
Controls - BK

Functions Pressure equalisation principle

Adjust so
same flow
Controls – HARDI-MATIC

Normal regulation valve HARDI-MATIC system


Engine r/min change = application rate change Engine r/min change = no application rate change

To Boom To Tank
To Boom To Tank
60%
55% 40%
45% Same speed
 = speed =& pressure
pressure 60% 40%
70% 30%  = speed =  pressure 60% 40%
Controls - EVC
Flowmeter Self-
(optional) cleaning
filter

Safety valve

Pressure
Equalisation
adjustment
Controls - EVC
“ON”
indicator

Pressure
dump
return

Section
OFF return
Controls - EVC
Electrical motor +
ON/OFF
-
Gear box
Momentary ON
Cam
Connector
Limiter switch
Micro-switch
Open-Close indicator
Diode
Valve seals
Cam
Gears never wear
Limiter switch can wear Electric motor
Seals for equalisation do wear
Controls

?
Controls – EVC & EFC
EVC EFC
Controls – EFC with DynamicFluid4

Based on 4 + 1 sensors
• Pump output
• Regulation valve output
• Flow
• Pressure

Not in fluid system


• Speed