You are on page 1of 125

ZXSDR BTS Configuration for

GU Co-site
Objective

 Understand basic conception of GU co-site


 Master the networking of GU co-site
 Understand the configuration flow of GU co-site
 Grasp the operation of LMT, OMCB, OMCR
 Grasp the meanings of each key parameter for
SDR
Contents

 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 BSC Configuration
 RNC Configuration
SDR Architecture
BS8700
Antenna
BBU

BB
CPRI
FS RRU
RadioUnit
Radio Unit Fiber
E1
SA/
STM- SE/
1 CC
NIS
GE/FE

=
Control
Signaling
Clock
Data

+ RRU
B8200

The
The structure
structure of
of BS8700
BS8700 is
is BBU
BBU plus
plus RRU,
RRU, with
with separated
separated modules
modules as
as Base
Base band
band unit
unit
and
and RF
RF unit.
unit.

© ZTE Corporation. All rights reserved


IP Abis/Iub Interface

 Different from traditional base stations, SDR base stations adopt


the all-IP architecture. Their Abis/Iub interfaces use the IP
protocol and physical bearing medium is FE/GE or E1/T1 (IP over
E1/T1) instead of traditional TDM over E1/T1. IP over E1/T1 can
take advantage of the existing transmission equipment to save
investment. FE/GE can obtain more bandwidth, which complies
with the evolution trend of the IP-based telecommunications
system.

© ZTE Corporation. All rights reserved


OMCB Definition

 OMCB- Operate and Maintenance Center for Node B

OMM OMCB OMCR

RNC BSC

SDR

© ZTE Corporation. All rights reserved


Networking of GU Co-site

Abis

OMCR
Switch or DDF

iBSC
B8200 MINOS

Iub

OMCR

RNC

© ZTE Corporation. All rights reserved


Data Planning

Configuration Flow
Hardware Inspection
 Data planning is kernel part process of the
entire SDR data configuration.
 Hardware Inspection checks the SDR rack,
LMT Configuration OMCB Configuration
board, physical connection, antenna, and
external alarms. It is performed on the
construction site and is not introduced in this BSC/RNC
Configuration
manual.
 LMT is a quick configuration tool for a single
SDR base station. A maintenance engineer can Data Configuration
Checking
connect the SDR and perform data
configuration by LMT. N
The link
 OMCB is the network management is established?

configuration tool for SDR base stations. After


Y
SDR is connected to OMCB, all the LMT
functions can be performed by OMCB. Data Synchronization

 The BSC/RNC side uses the interfacing data


with SDR.
Complete

© ZTE Corporation. All rights reserved


Contents

 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 BSC Configuration
 RNC Configuration
Racks and Boards Planning

 Rack 1: one BBU (B8200)


 Rack 2: one RRU (R8860), with the working frequency band of
1800MHz and the radio system of GSM
 Rack 3: one RRU (R8840), with the working frequency band of
2,100 MHz and the radio system of WCDMA
15 4 8

3 7
FS uBPG
14
PM 2 6

13 1 5
SA CC BPC

© ZTE Corporation. All rights reserved


Transmission Resource Planning
iBSC
EUIP_2GSDR:
172.18.6.254/24
OMP

EIPI
SDTB2 OMC1
(EUIP)
OMC2

IP Abis: IP Abis RPU


20.20.0.1

139.29.12.254/24
GSM IP: 172.18.6.18/24
WCDMA IP (IPoE1): 110.10.6.18/24

GIPI_OMCB:
WCDMA IP (IPoFE): 60.30.6.18/24 EUIP_3GSDR: 110.10.6.254/24
OMCB Link IP: 112.12.6.18/24 RNC EUIP_OMCB_CH: 112.12.6.254/24 GIPI

SDR FE1
EIPI
SDTB2 (EUIP) :
FE2

R 4 FE3
SD 4/2
3G 5
P I_ .6.2 FE4
I 0
G 0.3
6

ROMB SBCX
139.29.12.1/24
OMCB IP:

OMC1 OMC1
OMCB_CH_IP:

OMC2 OMC2
113.40.0.1

OMP1(OMCB)

IP Iub RPU IP Iub:


30.20.0.1
30.30.0.1
© ZTE Corporation. All rights reserved
Planning of SDR Transmission Resources and IP addresses

Name Meaning Address

GSM IP GSM IP address of SDR 172.18.6.18/24

WCDMA IP (IPoE1) WCDMA IP address of SDR (IP over E1) 110.10.6.18/24

WCDMA IP (IPoFE) WCDMA IP address of SDR (IP over FE) 60.30.6.18/24

OMCB Link IP OMCB Link IP address of SDR 112.12.6.18/24

EUIP_2GSDR IP address of iBSC for SDR Gateway (IPoverE1) 172.18.6.254/24

EUIP_3GSDR IP address of RNC for SDR Gateway (IPoverE1) 110.10.6.254/24


IP address of the OMCB channel for SDR O&M
EUIP_OMCB_CH 112.12.6.254/24
Gateway
GIPI_3GSDR IP address of RNC for SDR Gateway (IPoverFE) 60.30.6.254/24

GIPI_OMCB IP address of RNC for OMCB Gateway 139.29.12.254/24

OMCB_IP OMCB IP address configured for RNC 139.29.12.1/24


IP Abis IP Abis virtual address of iBSC 20.20.0.1
IP Iub virtual address 1 of RNC 30.20.0.1
IP Iub
IP Iub virtual address 2 of RNC 30.30.0.1
OMCB_CH_IP OMCB Channel IP 113.40.0.1
© ZTE Corporation. All rights reserved
Time Slot Allocation

E1 Link HDLC ID in Connection


Time Slot HDLC ID Remarks
ID BSC/RNC Side Object
Transparent
Link ID0 Slot 1-31 HDLC ID0 HDLC ID 1 iBSC transmission via
RNC

Link ID1 Slot 1-31 HDLC ID1 HDLC ID 2 RNC Straight-through

Link ID2 Slot 1-31 HDLC ID2 HDLC ID 3 RNC Straight-through

Link ID3 Slot 3-31 HDLC ID3 HDLC ID 4 RNC Straight-through

Link ID3 Slot 1-2 HDLC ID4 HDLC ID 5 RNC O&M Link of OMCB

© ZTE Corporation. All rights reserved


SCTP Association Parameters

Parameter Meaning Planned Value Remarks


Configure SDR port
GSM site number (SCTP port
GSM No. 6 number in the case of
number of 2GSDR)
SCTP for GSM
Node B ID UMTS site number 6 -
SCTP port number of
The home CMP
iBSC = 14592 + home
iBSC Port No. SCTP port number of iBSC module number of
CMP module number
SDR is 3.
of SDR
The configuration of
RNC Port No. SCTP port number of RNC 777 RNC is consistent with
that of SDR
The configuration of
3GSDR Port No. SCTP port number of 2GSDR 777 RNC is consistent with
that of SDR

© ZTE Corporation. All rights reserved


GSM Radio Resource

RF Unit R8860

Cell S4

Carrier Wave Power 20W for each Carrier Wave

Frequency point 520, 523, 527, 532

BCCH Frequency point 520

MCC 460

MNC 2
LAC 30
CI 6
NCC 0
BCC 0

© ZTE Corporation. All rights reserved


UMTS Radio Resource

RF Unit R8840

Carriers 3C

Carrier Wave Power 20W for each Carrier Wave

Frequency point 1920, 1925, 1930, 2110, 2115,2120

MCC 460

MNC 2
LAC 1
Local Cell ID 0,1,2

© ZTE Corporation. All rights reserved


Clock, Environment, and Monitored Data

Data Type Configuration

Environment Monitoring Configuration Default

Dry Contact Alarm Configuration Main Power Supply has a fault alarm

GPS: High priority; Line clock: Low


Clock Source Priority Configuration
priority

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 Overview
 Create SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource

 OMCB Configuration
 BSC Configuration
 RNC Configuration
Configuration Flow
LMT Login to SDR

Configuring SDR
Physical Data

Configuring
Transmission
Resource

Configuring Radio
Resource

Complete

© ZTE Corporation. All rights reserved


LMT Login to SDR

 LMT Use Prerequisite


 Install the jre-6u2-windows-i586-p.exe
 Install the LMT software.
 Login Mode
 Online configuration
 Offline configuration
 Login Steps
 IP calculation of BBU’s boards
 IP configuration of the debugging device
 How to distinguish between the active CC and standby CC

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 Overview
 Create SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource

 OMCB Configuration
 BSC Configuration
 RNC Configuration
Create Basic Attribute

© ZTE Corporation. All rights reserved


Create Rack

© ZTE Corporation. All rights reserved


Create Topology Structure
 Upper level and lower level: the board or
rack close to the BBU is of the upper level,
while the board or rack far away from the
BBU is of the lower level.
Each FS board in the BBU provides six
optical fiber interfaces used to connect
RRUs. From the front of the FS board, you
can see that the interface numbers are 0,
1, 2, 3, 4, 5 from right to left. The RRU
provides two optical fiber interfaces via
the DTR board. One is used to connect the
BBU with the interface number of LC0; the
other is used to connect the lower-level
RRU with the optical interface number of
LC1.Select star or link for the topology
type. RRS cascade can be realized only
when the topology type is link.

© ZTE Corporation. All rights reserved


Create Environment Monitoring

 The environment monitoring parameters are automatically


configured when a new board is added. The operator may adjust
the threshold values by modifying the environment monitoring
configuration.

© ZTE Corporation. All rights reserved


Create Dry Contact

© ZTE Corporation. All rights reserved


Create Clock Reference Source

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 Overview
 Create SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource

 OMCB Configuration
 BSC Configuration
 RNC Configuration
Transmission Resource Configuration Flow

To supports the SDR auto-link function, even though the Abis interface
only uses one HDLC channel, ML-PPP is still selected in Bearer Protocol.

© ZTE Corporation. All rights reserved


Create E1/T1 Line (IPoE1)

 The SA provides eight pairs of E1 cables totally, respectively


corresponding to Link ID0~Link ID07. 0 indicates the first pair of E1
cable, corresponding to the serial No. of the physical connection as 1
and 2. Link ID is used during creating the HDLC channel.
 If the link type is set as BSC + RNC, it indicates that GSM and WCDMA
share one E1 link (time slot sharing mode). In this topic, the SDR
connects with the RNC through three E1 links, and connects with the
iBSC by RNC transparent transmission through one E1 link.

© ZTE Corporation. All rights reserved


Create HDLC Parameter (IPoE1)

© ZTE Corporation. All rights reserved


Create PPP Parameter (IPoE1)
Connection
PPP ID Used HDLC ID
Object
PPP ID 0 HDLC ID0 iBSC
PPP ID 1 HDLC ID1~3 RNC
PPP ID 2 HDLC ID4 OMCB

© ZTE Corporation. All rights reserved


Create FE Parameter (IPoFE)

© ZTE Corporation. All rights reserved


Create Global Port

 ZTE defines the global port as follows: For the transmission mode
such as FE or E1, the data formats are unified after passing the
global port, and the subsequent configuration has no difference
between IPoE1 and IPoFE.

© ZTE Corporation. All rights reserved


Create IP Parameter

 IP ID0: WCDMA IP (IPoFE) uses it.


 IP ID1: GSM IP uses it.
 IP ID2: WCDMA IP (IPoE1) uses it.
 IP ID3: OMCB Link IP uses it.

© ZTE Corporation. All rights reserved


Create SCTP Association

© ZTE Corporation. All rights reserved


Create SCTP Stream (Only for WCDMA)

 This configuration is available only for WCDMA.


 The service types include NCP and CCP as follows:
 NCP: Node B control port, which manages signaling interaction in the
common process.
 CCP: Communication control port, which manages signaling interaction in
the dedicated process.

© ZTE Corporation. All rights reserved


Create OMC-B Link

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 Overview
 Create SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource

 OMCB Configuration
 BSC Configuration
 RNC Configuration
Create RRU Common Parameter

© ZTE Corporation. All rights reserved


Create RF Connection

© ZTE Corporation. All rights reserved


Create GSM Radio Resource

© ZTE Corporation. All rights reserved


Create WCDMA Radio Resource

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 Overview
 Configure Basic Properties
 Configuring SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource
 Data Synchronization & Upload

 BSC Configuration
 RNC Configuration
OMCB Configuration Flow
Add a Route

Modify Server
Configuration
File

Configure Basic
Properties

Configuring SDR
Physical Data

Configuring
Transmission
Resource

Configuring Radio
Resource

Data
Synchronization

Complete

© ZTE Corporation. All rights reserved


Add a Route

 1 . The command used to add a route on OMCB (SBCX) is:


 #route add -net 112.12.6.18 gw 139.29.12.254 netmask 255.255.255.0 139.29.12.1
  Note :
 In the LINUX system, the command used to add a route is:
 route add -net destination network address gw next-hop address netmask IP address of
the network mask
 2 . After the operation, execute the netstat –nr command to view the
route.
 3 . Set a permanent route. After adding the route using the route add
command, to avoid route loss after restarting the SBCX, you can add the
line blow into the /etc/rc.d /rc.local file as the root user:
 #route add –net 112.12.6.18 gw 139.29.12.254 netmask 255.255.255.0 139.29.12.1

© ZTE Corporation. All rights reserved


Modify Server Configuration File
 Modify deploy-030womcb.properties
 1 . Log in to the server as the OMC user.
 2 . Enter the …\ums-svr\deploy directory, and then open the deploy-
030womcb.properties file.
 3 . Modify the fields in the red box to OMCB_IP.

 Modify FTP Configuration File as the OMC User


 1. Log in as the gomcr user, and then check whether userdefined-uep-psl-ftpserver.port
in the /home/gomcr/ums-svr/deploy/deploy-gsmomcr01.properties file is 20021.
 2 . Log in as the root user, and then check whether listen_port in the
/etc/vsftpd/vsftpd.conf file is 10021.
 3 . If the value is not the correct one, modify it.

© ZTE Corporation. All rights reserved


Modify Server Configuration File

 Modify the deploy-default.properties file as the OMC user


 1 . Log in to the server as the OMC user.
 2 . Enter the …\ums-svr\deploy directory, and then open the
deploy-default.properties file.
 3 . Search the userdefined-uep-psl-ftpserver.port field and
make sure that the value of this field is identical with the
configuration of the ftpserver port enabled on the OMCB server.
If it is not, then modify the value to 20021.

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 Overview
 Configure Basic Properties
 Configuring SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource
 Data Synchronization & Upload

 BSC Configuration
 RNC Configuration
Create SDR Management NE

© ZTE Corporation. All rights reserved


Apply Mutex Right

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 Overview
 Configure Basic Properties
 Configuring SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource
 Data Synchronization & Upload

 BSC Configuration
 RNC Configuration
Create Base Station Equipment Resource Management

© ZTE Corporation. All rights reserved


Create BBU Rack

© ZTE Corporation. All rights reserved


Create RRU Rack

© ZTE Corporation. All rights reserved


Create Rack Topology

© ZTE Corporation. All rights reserved


Create Antenna

© ZTE Corporation. All rights reserved


Create Clock Source Priority

© ZTE Corporation. All rights reserved


Create Dry Contact Alarm

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 Overview
 Configure Basic Properties
 Configuring SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource
 Data Synchronization & Upload

 BSC Configuration
 RNC Configuration
Transmission Resource Configuration Flow

© ZTE Corporation. All rights reserved


Create E1/T1 Line (IPoE1)

© ZTE Corporation. All rights reserved


Create High-Level Data Link Control (IPoE1)

© ZTE Corporation. All rights reserved


Create PPP (IPoE1)
Connection
PPP ID Used HDLC ID
Object
PPP ID 0 HDLC ID0 iBSC
PPP ID 1 HDLC ID1~3 RNC
PPP ID 2 HDLC ID4 OMCB

© ZTE Corporation. All rights reserved


Create Ethernet(IPoFE)

© ZTE Corporation. All rights reserved


Create Global Port

© ZTE Corporation. All rights reserved


Create IP Parameter

 IP ID0: WCDMA IP (IPoFE) uses it.


 IP ID1: GSM IP uses it.
 IP ID2: WCDMA IP (IPoE1) uses it.
 IP ID3: OMCB Link IP uses it.

© ZTE Corporation. All rights reserved


Create IP Parameter

© ZTE Corporation. All rights reserved


Create SCTP Association

© ZTE Corporation. All rights reserved


Create SCTP Stream (Only for WCDMA)

 create the SCTP stream parameters of NCP and CCP

© ZTE Corporation. All rights reserved


Create OMC-B Link

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 Overview
 Configure Basic Properties
 Configuring SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource
 Data Synchronization & Upload

 BSC Configuration
 RNC Configuration
Create Base Station Radio Resource Management

 1. In the resource tree, choose the Config Set node under the
SDR. Right-click Config Set and choose Create > Base Station
Radio Resource Management in the popup menu to open the
Base Station Radio Resource Management dialog box. Click OK.

 2. The Base Station Radio Resource Management node is


displayed in the resource tree.

© ZTE Corporation. All rights reserved


Create RRU Common Parameter

© ZTE Corporation. All rights reserved


Create RF Connection

© ZTE Corporation. All rights reserved


Create GSM Radio Resource 1

© ZTE Corporation. All rights reserved


Create GSM Radio Resource 2

© ZTE Corporation. All rights reserved


Create GSM Radio Resource 3

© ZTE Corporation. All rights reserved


Create WCDMA Radio Resource 1

© ZTE Corporation. All rights reserved


Create WCDMA Radio Resource 2

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 Overview
 Configure Basic Properties
 Configuring SDR Physical Data
 Configuring Transmission Resource
 Configuring Radio Resource
 Data Synchronization & Upload

 BSC Configuration
 RNC Configuration
Data Synchronization

© ZTE Corporation. All rights reserved


Upload Data to OMCB

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 BSC Configuration
 Overview
 IP over E1 Interface Configuration
 Create IP Property
 Create SDR Site and Radio Resource

 RNC Configuration
BSC Configuration Flow IP over E1 Interface
Configuration

Create IP Property

Create SDR Site


and Radio
Resource

Complete

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 BSC Configuration
 Overview
 IP over E1 Interface Configuration
 Create IP Property
 Create SDR Site and Radio Resource

 RNC Configuration
Create Abis Interface Board

© ZTE Corporation. All rights reserved


Create IP Abis Interface

© ZTE Corporation. All rights reserved


Create SDR Real Interface

© ZTE Corporation. All rights reserved


Create IP over E1 Configuration

© ZTE Corporation. All rights reserved


Create PPP Configuration

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 BSC Configuration
 Overview
 IP over E1 Interface Configuration
 Create IP Property
 Create SDR Site and Radio Resource

 RNC Configuration
Create IP Property

© ZTE Corporation. All rights reserved


Contents
 Overview
 Data Planning
 LMT Configuration
 OMCB Configuration
 BSC Configuration
 Overview
 IP over E1 Interface Configuration
 Create IP Property
 Create SDR Site and Radio Resource

 RNC Configuration
Create SDR Site

© ZTE Corporation. All rights reserved


Create Cell

© ZTE Corporation. All rights reserved


Create TRX

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Configuration Flow
Configuring
Configuring
Start Node B Office
Global Supplemented
Info

Configuring
Configuring Configuring Node B
IP over E1 Interface Path Group Configuration
Information

Configuring Configuring Configuring


IP over FE Interface SCTP Association UTRAN CELL

Configuring
Configuring
RPU Board IP Address
Node B Office Complete
Information

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create Iub Interface Board

 Create Iub Interface Board SDTB2/EIPI

© ZTE Corporation. All rights reserved


Create Semi-Permanent Connection For SDTB2

© ZTE Corporation. All rights reserved


Create Connection Between SDTB2 and EIPI

 According to the planned data, HDLC ID1 is transmitted to iBSC


through semi-permanent channel. Therefore, only the remaining
four HDLC channels need to be configured at RNC side.

© ZTE Corporation. All rights reserved


EIPI Configuration----Creating IP Over E1 Ports

 According to the planned data, there are totally four E1 lines to


be processed on EIPI board. HDLC ID2, HDLC ID3, and HDLC ID4
use the same communication port number. HDLC ID5 is a
dedicated channel of OMCB and it needs an individual port
number. Therefore ,four IP Over E1 port numbers need to be
created.

© ZTE Corporation. All rights reserved


EIPI Configuration----Creating PPP Link for EUIP Port

 Each IP over E1 must be configured with a PPP link. The links with
the same InterfaceE1 No will be automatically bound in the same
PPP link. .

© ZTE Corporation. All rights reserved


EIPI Configuration----Creating Interface IP Addresses

 The following two IP addresses need to be configured for EIPI


board:
 EUIP_3GSDR: This IP address is used to transfer service data.
 EUIP_OMCB: This IP address is used to transfer OMCB supervision data.

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create GIPI IP Interface

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create RPU Board IP Address

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create Node B Office

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create Path Group

 This task creates the path group and assign the path group
number.

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create SCTP Association

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create Node B Office Properties

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Create Global Supplemented Resource

 Global supplemented resource is used for OMCB RPU IP address


and outgoing OMCB NM IP.

© ZTE Corporation. All rights reserved


Contents
 Overview

 Data Planning

 LMT Configuration

 OMCB Configuration

 BSC Configuration

 RNC Configuration
 Overview
 IP over E1 Interface Configuration
 IP over FE Interface Configuration
 RPU Board IP Address Configuration
 Node B Office Configuration
 Path Group Configuration
 SCTP Association Configuration
 Node B Office Properties Configuration
 Global Supplemented Resource Configuration
 Radio Resource Configuration
Radio Resource Configuration-----------Node B
Configuration Information
 This task creates the management relation between RNC and
Node B, and configures the basic information.

© ZTE Corporation. All rights reserved


Radio Resource Configuration-----------Create
UTRAN Cell Global Information

© ZTE Corporation. All rights reserved


Radio Resource Configuration-----------Create
UTRAN Cell Setup Parameters

© ZTE Corporation. All rights reserved