Professional Documents
Culture Documents
Applicable to Staff who need to learn the new tools in iBSCV6.20.71 series versions
Released by GU Product Support Dept.
Internal Only▲
Version Introduction
Version Date Author Checked by Amendment Record
References:
1.
2.
Internal Only▲
Course Objectives:
To learn the new tools of iBSCV6.20.71
To master the usage of OMP Remote
Commissioning Tool
To master the usage of OMM Remote Auto
Install Tool
Internal Only▲
Contents
Single SBCX installed with R&B integration and R&B split versions
Contents
Parameters
Parameter Default Value
SBCX OMC1(eth3) ip Preset as 192.168.1.100
SBCX
SBCX OMP1(eth6) ip Preset as 129.0.31.100/24
OMP IP Preset as 129.0.31.200/24
OMP MAC NULL
OMC server IP Preset as 129.0.31.100/24
OMC server FTP username uep
OMC server FTP password uep
Actual path of ompcfg.ini in OMC
OMP tmp/ftp/version/bsc253
server
Configuration file name ompcfg.ini
OMP Boot Type 0
Set switch office No. 253
FTP Username to Log in to OMP zte
FTP Password to Log in to OMP zte
Internal Only▲
Contents
$OMCHOME/deploy/deploy-gsmomcr01.properties
$OMCHOME/deploy/deploy-030womcb.properties
$OMCHOME/deploy/deploy-999split.properties
$ORACLE_HOME/network/admin/listener.ora
$ORACLE_HOME/network/admin/tnsnames.ora
/home/zte/Ommhost/bin/conf/Netif00.conf
/home/zte/Ommhost/bin/conf/Netif01.conf
Internal Only▲
Contents
<version>iOMCRV6.20.710e</version>
<startserverip>10.63.208.173</startserverip>
<startserveruser>gomcr</startserveruser>
<startserverpassword>gomcr123</startserverpassword>
Improvement of Signaling Trace -- Internal Only▲
-- Failure Observation
The failure observation function is supported in the
Signaling Trace since V6.20.61 series versions.
Set the corresponding parameters in OMM first:
Improvement of Signaling Trace Internal Only▲
-- Failure Observation
Open the CDT Parameters tab, set Yes for the
FOOption buttons.
Improvement of Signaling Trace Internal Only▲
-- Failure Observation
In the Trace Set window in the Signaling Trace, the
following check boxes can be chosen:
FOCS
FOPS
FODBS
Improvement of Signaling Trace Internal Only▲
-- Failure Observation
In the FOCS window as shown below, the following items
can be chosen for tracing:
Improvement of Signaling Trace Internal Only▲
-- Failure Observation
The FOPS window is shown below:
Improvement of Signaling Trace Internal Only▲
-- Failure Observation
The FODBS window is shown below:
Improvement of Signaling Trace Internal Only▲
-- Failure Observation
Tracing result:
If any signaling fails, the R&D engineer should provide the description
for the failure cause, and the analysis guide for the failed signaling.
Internal Only▲
Contents
-bash-3.00$ pwd
/home/gomcr/ums-svr/tools/tools-mrm-comm
-bash-3.00$ ls
burearnoPortConf.properties conf lib log log4j.properties mrm.bat
mrm.sh tools-mrm-comm.jar
-bash-3.00$ nohup ./mrm.sh &
[1] 1291
-bash-3.00$ nohup: appending output to ‘nohup.out’
Internal Only▲
E:\work\
V4+iBSC71½Ì²Ä¿ª·¢¼Æ»®\SpeechListe
Internal Only▲
Chapter/Course Review