You are on page 1of 58

Internal Only▲

ZXG10 iBSCV6.20.71 New Tools

Applicable to Staff who need to learn the new tools in iBSCV6.20.71 series versions
Released by GU Product Support Dept.
Internal Only▲

Version Introduction
Version Date Author Checked by Amendment Record

R1.0 2011-12-27 Sun Liu Guanghua None


Jingjing

R1.2 2012-05-04 Sun Liu Guanghua None


Jingjing

References:
1.
2.
Internal Only▲

Course Objectives:
To learn the new tools of iBSCV6.20.71
To master the usage of OMP Remote
Commissioning Tool
To master the usage of OMM Remote Auto
Install Tool
Internal Only▲

Contents

OMM Remote Auto Install Tool


OMP Remote Commissioning Tool (Instead of
Serial Port Commissioning)
Improvement of modifyip Tool
Improvement of Signaling Trace
Speech Listen Tool
Internal Only▲

OMM Remote Auto Install Tool


 Tool location:
 iOMCRV6.20.711c-OMCBV4.00.200m\gsmomcr\tools\
remoteSetupTool
 Software modules supporting remote installation:
 OMMR&B integration software

 OMMB independent software

 OMMHost, software for master/slave SBCX deployment


Internal Only▲

OMM Remote Auto Install Tool


 Double-click run.bat in the tools\remoteSetupTool\
remoteSetup path, the following Welcome window
pops up:
Internal Only▲

OMM Remote Auto Install Tool


 Click ENTER to enter the GLOBAL parameter setting
window.
 Fill in the GLOBAL parameters, and select the software
package to be installed.
Internal Only▲

OMM Remote Auto Install Tool


 Applicable Scenarios:
 Master/slave SBCXs installed with R&B integration and R&B split
versions

 Single SBCX installed with R&B integration and R&B split versions

 Single SBCX installed with R&B integration version


Internal Only▲

OMM Remote Auto Install Tool


 This tool cannot be used to perform R&B split.
 In the scenario of “Master/slave SBCXs installed
with R&B integration and R&B split versions”,
install the software in master and slave SBCX
separately.
Internal Only▲

OMM Remote Auto Install Tool


 OMM HOST installation parameters:
Internal Only▲

OMM Remote Auto Install Tool


 GSM_OMCR installation parameters:
Internal Only▲

OMM Remote Auto Install Tool


 OMCB installation parameters:
Internal Only▲

OMM Remote Auto Install Tool


 After setting the parameters, acknowledge the
installation information in the following figure:
Internal Only▲

OMM Remote Auto Install Tool


 Click Install, and the install process is started as
shown in the following figure:
Internal Only▲

Contents

OMM Remote Auto Install Tool


OMP Remote Commissioning Tool (Instead of
Serial Port Commissioning)
Improvement of modifyip Tool
Improvement of Signaling Trace
Speech Listen Tool
OMP Remote Commissioning Tool (Instead of Internal Only▲

Serial Port Commissioning)


 During iBSC commissioning, after the equipment is powered on, the OMP
cannot get communicated with the SBCX server directly. Set the eth6 network
adapter of SBCX server, commission the OMM serial port, and then
communicate the OMP with SBCX server. This operation should be performed
in the iBSC equipment room. In some conditions (for example, if the
commissioning cable of OMP serial port is missing, the commissioning engineer
is not on site, or the completion period is too limited, etc.), the commissioning
progress may be delayed. And therefore, the remote iBSC commissioning can
be used to perform OMP commissioning when there is no serial commissioning
cable. The engineer can also perform the iBSC commissioning remotely.
 The following functions are available from the V6.20.614f version:
 After power-on, SBCX and OMP can be communicated with each other.
 The initial OMP architecture information is factory default, it is not necessary to
commission the OMP board through the serial commissioning cable in the near end.
 In order to modify the OMP related information, perform the setting in the OMM.
OMP Remote Commissioning Tool (Instead of Internal Only▲

Serial Port Commissioning)


 Four buttons in BSC Software Version Management:
 Query OMP BOOT Mode
 Set OMP BOOT Mode
 Query OMP BOOT Parameter
 Set OMP BOOT Parameter
OMP Remote Commissioning Tool (Instead of
Internal Only▲

Serial Port Commissioning)


 Query and Set OMP BOOT Mode
OMP Remote Commissioning Tool (Instead of
Internal Only▲

Serial Port Commissioning)


 Query OMP BOOT Parameter
OMP Remote Commissioning Tool (Instead of
Internal Only▲

Serial Port Commissioning)


 Set OMP BOOT Parameter
Factory Default Values of OMP Related Internal Only▲

Parameters
Parameter Default Value
SBCX OMC1(eth3) ip Preset as 192.168.1.100
SBCX
SBCX OMP1(eth6) ip Preset as 129.0.31.100/24
OMP IP Preset as 129.0.31.200/24
OMP MAC NULL
OMC server IP Preset as 129.0.31.100/24
OMC server FTP username uep
OMC server FTP password uep
Actual path of ompcfg.ini in OMC
OMP tmp/ftp/version/bsc253
server
Configuration file name ompcfg.ini
OMP Boot Type 0
Set switch office No. 253
FTP Username to Log in to OMP zte
FTP Password to Log in to OMP zte
Internal Only▲

OMP Commissioning Flow Description


1. Perform basic data configuration according to the factory default values.
2. Make sure IBSC and OMM communicate with each other normally.
3. Plug out the slave OMP.
4. Load OMP version.
5. Set OMP Boot parameter in OMM.
6. Set OMP Boot Mode in OMM.
7. Reset master OMP to complete OMP version loading.
8. Modify the IP related parameters in OMM according to onsite planning,
including OMM Boot parameter, OMM Boot Mode, and the IP in BSC Function.
9. Reset OMP to make the new IPs valid.
10. Use the modifyip tool according to onsite planning to modify the eth6 IP of
SBCX server.
11. Reset SBCX to make the new eth6 IP valid.
12. Modify OMP IP configured in BSC Managed Element, make sure the iBSC and
OMM can communicate normally.
13. Plug in the slave OMP.
Internal Only▲

Contents

OMM Remote Auto Install Tool


OMP Remote Commissioning Tool (Instead of
Serial Port Commissioning)
Improvement of modifyip Tool
Improvement of Signaling Trace
Speech Listen Tool
Internal Only▲

Improvement of modifyip Tool


 The modifyip tool in the iOMCRV6.20.61 series versions
can be used to modify the eth3, eth4, and eth6 IP
addresses of the server. and the parameters in the
configuration file related to iOMCR can be modified at the
same time, which do not need to be modified manually.
 From the iOMCRV6.20.71 version, the tool supports the
R&B split and master/slave SBCX rectification scenarios,
which can be used to modify the eth3, eth3:1, eth3:2, eth4,
eth4:1, and eth6 IP addresses of the server. Thus this tool
is convenient for the IP replanning on site.
Internal Only▲

Improvement of modifyip Tool


 Software path: xxxx\ums-svr\tools\modifyip,
including the modifyip.pl script and description file
readme.txt.
 This tool only support Linux OS. Use the root user
to run the tool.
 If the IP is modified in the master/slave SBCX
scenario with the tool, make sure the OmmHost is
running during the modification.
 This tool only modifies the IP related file, the
gateway or mask should be modified manually in
the corresponding file.
Internal Only▲

Improvement of modifyip Tool


 The following configuration files are modified with the tool:
 /etc/hosts
 /etc/sysconfig/network-script/ifcfg-XXXX

 $OMCHOME/deploy/deploy-gsmomcr01.properties
 $OMCHOME/deploy/deploy-030womcb.properties
 $OMCHOME/deploy/deploy-999split.properties

 $ORACLE_HOME/network/admin/listener.ora
 $ORACLE_HOME/network/admin/tnsnames.ora

 /home/zte/Ommhost/bin/conf/Netif00.conf
 /home/zte/Ommhost/bin/conf/Netif01.conf
Internal Only▲

Improvement of modifyip Tool


 In order to modify the gateway or mask, modify
the file manually:
/etc/sysconfig/network-script/ifcfg-XXXX:
 NETMASK=255.255.252.0
 GATEWAY=10.61.39.254
Internal Only▲

Improvement of modifyip Tool


 How to execute the script:
 Log in as the root user to enter the tool path, execute the perl
modifyip.pl interface ip command to modify the IP. In this
command, interface refers to the network adapter to be modified,
and ip refers to the target IP to be modified.
 For example: # perl modifyip.pl eth3 10.63.208.173
 After the execution of the script, restart Linux OS to make
the modification valid.
 When the server is connected remotely, if the IP of the connected
network adapter is modified, use the target IP to connect the server
again after it is restarted. If any problem occurs, connect the monitor
with the SBCX directly in the near end for inspection.
Internal Only▲

Improvement of modifyip Tool


 Solution for abnormal conditions:
 If error operations are performed, still use the tool to
modify the IP address.
 If the log is not available, check the modification status
in the file of the temp directory.
 After the tool is executed successfully, if there is no
prompt for successful operation, check whether the file
in the temp directory is correct.
 All the related modified files are saved in the temp
directory.
Internal Only▲

Contents

OMM Remote Auto Install Tool


OMP Remote Commissioning Tool (Instead of
Serial Port Commissioning)
Improvement of modifyip Tool
Improvement of Signaling Trace
Speech Listen Tool
Internal Only▲

Improvement of Signaling Trace


 Start server process form the client of signaling
trace
 Execute signaling trace according to subscriber’s
phone number
 Support failure observation
Improvement of Signaling Trace Internal Only▲

-- Starting Server Process in the Client


 In the iOMCR Signaling Trace -- Login window, there is a new start
server button. The server can be started by clicking this button, instead
of logging in to the server and executing the corresponding command
to start the server program.
 Add the coresponding information like startserverip, etc. in the
configuration file of Signaling Trace client:
 Configuration file: \iOMCRV6.20.710e\ums-clnt\tools\zxgomcr-sigtrace\
client\conf\clientcfg.xml

<version>iOMCRV6.20.710e</version>
<startserverip>10.63.208.173</startserverip>
<startserveruser>gomcr</startserveruser>
<startserverpassword>gomcr123</startserverpassword>
Improvement of Signaling Trace -- Internal Only▲

Starting Server Process in the Client


 In the iOMCR Signaling Trace -- Login window,
there is a new start server button on the top left
corner. Click this button to start server process.
Improvement of Signaling Trace Internal Only▲

-- Starting Server Process in the Client


 Clicking “start server” is the same as starting signaling
trace server.
 If the signaling trace server is started at the first time, the
engineer needs to log in to the server to modify the server
configuration file. Otherwise, the server cannot be
connected with OMP.
 Currently, only the “start server” button is available, there
is no button to stop server. The engineer needs to log in to
the signaling trace server to stop it manually.
 By clicking start server, a command for starting server is
sent. If the server has already been started, when the
button is clicked, the command will still be sent. but the
normal system running is not affected.
Improvement of Signaling Trace Internal Only▲

--Tracing According to Subscriber’s Phone


No.
 In the Trace Set window of Signaling Trace, there are two
new tracing options: ISDNCALLED (phone No. of the
called party) and ISDNCALLING (phone No. of the calling
party).
Improvement of Signaling Trace Internal Only▲

--Tracing According to Subscriber’s Phone


No.
 In the Trace Set window of ISDNCALLED/ISDNCALLING,
add the mobile phone No. for signaling tracing.
Improvement of Signaling Trace Internal Only▲

--Tracing According to Subscriber’s Phone


No.
 In the following example, the calling party No. is
18600210143, the called party No. is 18600210175. The
Tracing result is shown in the following figure:
Improvement of Signaling Trace Internal Only▲

-- Failure Observation
 The failure observation function is supported in the
Signaling Trace since V6.20.61 series versions.
 Set the corresponding parameters in OMM first:
Improvement of Signaling Trace Internal Only▲

-- Failure Observation
 Open the CDT Parameters tab, set Yes for the
FOOption buttons.
Improvement of Signaling Trace Internal Only▲

-- Failure Observation
 In the Trace Set window in the Signaling Trace, the
following check boxes can be chosen:
 FOCS

 FOPS

 FODBS
Improvement of Signaling Trace Internal Only▲

-- Failure Observation
 In the FOCS window as shown below, the following items
can be chosen for tracing:
Improvement of Signaling Trace Internal Only▲

-- Failure Observation
 The FOPS window is shown below:
Improvement of Signaling Trace Internal Only▲

-- Failure Observation
 The FODBS window is shown below:
Improvement of Signaling Trace Internal Only▲

-- Failure Observation
 Tracing result:

 If any signaling fails, the R&D engineer should provide the description
for the failure cause, and the analysis guide for the failed signaling.
Internal Only▲

Contents

OMM Remote Auto Install Tool


OMP Remote Commissioning Tool (Instead of
Serial Port Commissioning)
Improvement of modifyip Tool
Improvement of Signaling Trace
Speech Listen Tool
Internal Only▲

Speech Listen Tool


 A new Speech Listen Tool is provided in the
V6.20.71 version. The user can perform Query
Connect Information and Speech Listen by typing
IMSI, or the information of the base station, cell,
TRX, and channel occupied by the conversation.
 Meanwhile, the audio file can be saved to the local
drive, and replayed with this tool.
 The configuration files should be configured in
both server and client ends.
Internal Only▲

Speech Listen Tool


 The path for the tool in the server: $OMCHOME/tools/tools-mrm-
comm ;
 The configuration file in the server is
/home/gomcr/ums-svr/tools/tools-mrm-comm/conf/links.xml :

<?xml version="1.0" encoding="GB2312"?>


<mrm_links>
<front_nes>
<!—Only modify omp_ip and bureano. Do not modify Port 35057
and Port 5057-->
<omp mrm_port="35057" bureano="102" omp_ip="172.20.2.3"
omp_port="5057" />
</front_nes>
Internal Only▲

Speech Listen Tool


 Start server process:

-bash-3.00$ pwd
/home/gomcr/ums-svr/tools/tools-mrm-comm
-bash-3.00$ ls
burearnoPortConf.properties conf lib log log4j.properties mrm.bat
mrm.sh tools-mrm-comm.jar
-bash-3.00$ nohup ./mrm.sh &
[1] 1291
-bash-3.00$ nohup: appending output to ‘nohup.out’
Internal Only▲

Speech Listen Tool


 The client software package is not integrated in
the iOMCR package, but is released separately.

E:\work\
V4+iBSC71½Ì²Ä¿ª·¢¼Æ»®\SpeechListe
Internal Only▲

Speech Listen Tool


 Execute SpeechListenTool.exe in the package:
Internal Only▲

Speech Listen Tool


 Click the button to set the parameters in the Connect
Server window:

 Set IP address as the external IP of SBCX, and Port as the


mrm_port value in the links.xml file of the server (Keep
the default value: 35057). Click Connect to establish link
with the server.
 If the Server status in the tool window is Connect, it
indicates the tool is connected with the server normally. At
this time, the Query Connection Information and Speech
Listen can be performed.
Internal Only▲

Speech Listen Tool


 Click the button to set Speech Listen
information.
 Query Connect Information
 Query by IMSI
Internal Only▲

Speech Listen Tool


 Query Connect Information
 Query by radio information (Site, Bts, Trx, and Ts)
Internal Only▲

Speech Listen Tool


 Speech Listen
 The listen points supported by the software:

Up Receive, Up Send, Down Receive, and Down Send points
of IPRB (BIPB) on the Abis interface

Up Receive, Up Send, Down Receive, and Down Send points
of AIPB (DRTB and TIPB) on the A/Ater interface
 The unavailable listen points are dimmed on the tool
window.
Internal Only▲

Speech Listen Tool


 For example: AIPB Up Send
Internal Only▲

Speech Listen Tool


 Click or to start or stop listen process.
Internal Only▲

Chapter/Course Review

 OMP serial port commissioning is not required in the V6.20.71 version, so


how to perform remote commissioning on the OMP board delivered to the
field?
 Which software packages are supported by OMM Remote Auto Install
Tool?
 How is the Signaling Trace improved?
 How to use the Speech Listen Tool?
Internal Only▲