Item

Description ISOLA - EXTERNAL WORK


ELEMENT NO. 5 - GUARD HOUSE WORK BELOW LOWEST FLOOR FINISH Notes : 1) The contractor shall allow in his rates for coordination and provision of M & E opening/outlet requirement. The contractor is required to submit shop drawings to Engineer for approval and incorporate all M & E requirement and starter bar layout/positio 2) The cost for any hacking, coring and cutting off starter bars due to misalignment to be done by others will be borne by the Contractor. Excavation commencing from basement platform level including earthwork support, levelling, compacting bottom and trimming sides of excavation

Unit

Qty

Rate

Amount (RM)

A Maximum depth not exceeding 2.00m in pad footing (provisional) m3 B Ground beam not exceeding 1.00m in trench (provisional) Disposal of excavated material Excavated materials to be removed from the site to Contractor's own dump and the provision of a shoot, dump or tip, royalties, C fees, levies, and other charges shall be deemed to be included (provisional) 150mm Thick (consolidated) bed of crusher run as described D spread, levelled, blinded, watered, and consolidated under lean concrete average 1.50m deep for OSD tank (provisional) Lean concrete Grade 15 as described blinding screed to receive Pile cap not exceeding 100mm (provisional) Mild steel rod reinforcement B.S. 4449 F 10mm Diameter as stirrups In ground beam (provisional) High yield tensile rod reinforcement B.S. 4449 G 25mm Diameter bar In pile caps (provisional) H 25mm Diameter bar In column stump (provisional) J 25mm Diameter bar In ground beam (provisional) kg kg kg kg m3

1.00 2.00

m3

3.00

m2

30.00

m2

30.00

36.00

216.00 74.00 179.00

To Collection RM

G1/5/1

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd) Reinforced concrete Grade 30 as describe (provisional) A In pad footing B In column stump C In ground beam D Thickness exceeding 150mm but not exceeding 300mm in concrete slab m3 m3 m3 m3 1.00 1.00 2.00 6.00

E Ditto in apron slab Layer of steel fabric reinforcement to B.S 4483 as described (B.S. Ref No. A6-weighing not less than 2.22kg/m2) well lapped at joints and embedded as discribed in F In concrete bed (provisional) G In apron slab (provisional) Sawn Formwork as described to (provisional) H Sides of pad footing J Sides of ground beam K Sides of column stump L Edge of concrete slab exceeding 300mm M Edge of apron slab exceeding 300mm FRAME Reinforced concrete Grade 25 as described N Column P Roof beam Mild steel bar reinforcement as described Q 6mm Diameter as links in column R 10mm Diameter 'U' Bars embanded in Colum S 6mm Diameter as link in beam

m3

1.00

m2 m2

30.00 6.00

m2 m2 m2 m2 m2

4.00 3.00 3.00 2.00 3.00

m3 m3

1.00 1.00

kg kg kg

24.00 8.00 17.00

To Collection RM

G1/5/2

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd) High yield steel bar reinforcement as described A 12mm Diameter in column B 12mm Ditto roof beam C 16mm Ditto roof beam Sawn formwork as described to D Sides of column E Sides and soffit of roof beam Fabricate supply and install in position structural steel section to B.S 5950 and material properties to B.S 4360 Grade 43 as described F 150mm x 200mm x 4.8mm x 25.4kg/m RHS Column 300mm x 350mm x 10mm thick M.S Base Plate welded to G column Stifferner including forming opening for bolts to R.C Beam (measured seperately) kg 328.00 m2 m2 12.00 8.00 kg kg kg 66.00 23.00 41.00

No.

3.00

20mm Diameter HT Holding Down Bolts 200mm long with head, No. c/w Nut & Washer on bothsides

12.00

230mm x 230mm x 10mm thick mild steel base plate to welded with U steel bars including infill with with non-shrink grout J between the plate and 230mm x 230mm reinforce concrete column as per Drawing no NJASB0611/SJCC/GH/01 ROOF

No.

4.00

Supply and install 12mm thick green tinted laminated glass fixed to 40mm x 100mm selected aluminium framing with sealant to m2 K specialist details complete with all neccessary fixing and accessories to manufacturer's detail Reinforced Conrete Grade 30 as described in L 125mm Thick Suspended Roof Slab m2

16.00

9.00

Extra over for forming 100mm diameter outlet for rainwater M downpipe.(measured seperately) through 125mm thick suspended No. slab with and including pipe sleeve,sealant around opening N Extra over for forming 150 x 200mm deep scupper drain m

1.00

3.00

To Collection RM

G1/5/3

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd) Layer of steel fabric reinforcement to B.S 4483 as described (B.S. m2 A Ref No. A6-weighing not less than 2.22kg/m2) well lapped at joints and embendded in concerete bed Layer of steel fabric reinforcement to B.S 4483 as described (B.S. m2 Ref No. A7) well lapped at joints and embendded in concerete bed

9.00

9.00

Sawn formwork as described to C Soffit of suspended roof slab Cement and sand (1:4) mixed with an approved plasticier as described D 20mm thick to soffit of suspended roof slab Waterproofing System Note: The Contractor shall allow in his rates for oordination and supervision of waterproofing treatment around M&E opening/outlet requirement including provision of swellable/PVC water stop m2 9.00 m2 9.00

Prepare and apply two coats at 1.7kg/m2/coat 'Mapelastic' UV stable fiber waterproofing reinforced complete with layer 'Mapenet 150' all shall according per manufacturer's instruction

E Top of flat roof Prepare and apply three coats 'Aquaflex Roof' or other equal and approved paint as described on the following surfaces F Plastered surface of roof slab Unplasticised polyvynil chloride rainwater downpipe to B.S. 4576 class C and fittings including jointing with solvent cement in accordance with the manufacturer's instruction 100mm Diameter rainwater downpipe fixed to wall and column with approved mild steel bracket

m2

9.00

m2

9.00

5.00

To Collection RM

G1/5/4

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd) STEEL ROOF TRUSSES TENDERER NOTE : 1) Prior to the fabrication of any steelwork, the Contractor shall submit and obtain approval for all steelwork shop drawings. All steel details and connections and splice detail shall be in accordance with the requirementd of BS 5950 2)All shop drawings shall be endorsed by Professional Engineer 3)All welds to be 5mm fillet weld (leg lenght) electrode strenght E43 to BS 639.

Fabricate supply and install in position structural steel section to B.S 5950 and material properties to B.S 4360 Grade 43 as described A 100mm x 200mm x 4.5mm x 20.5kg/m RHS welded to 100mm x kg 200mm x 4.5mm thick RHS roof structure Prepare and apply one coat Zinc Chromate primer or other B approved similar and two (2) coats nicaceous iron oxide on general surfaces of steel trusses EXTERNAL WALLS Half-brick wall in cement and sand bricks in composition mortar C as described reinforced with and including brick reinforcement and bonding tie as described D Noidc 1,150.00

Tonne

1.00

m2

18.00

Horizontal damp-proof course as described laid on half-brick wall m (measured nett - no allowance made for laps)

11.00

6mm Diameter mild steel as described bonding tie 450mm girth E one end hooked and cast in concrete and other end built into joints No. of brickwork including perforation in formwork To boxup exposed pipes with 12mm thick gypsum board on galvanised iron framing to specialist details with and including all m2 F necessary to all manufacturer detail and Architect's approval (Provisional)

32.00

10.00

To Collection RM

G1/5/5

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd) WINDOWS TENDERER TO NOTE: 1) The sizes are only as a guide in tendering and the tenderer shall supply all the units in accordance with the architectural drawings/site measurements and no claims will be entertained for any discrepancy between the Drawing and Bill of Quantities 2) Rates for aluminium works shall include all cutting and waste, cutting holes for electrical wiring and conduits, etc. 3) Allow for submission of shop drawings and samples to Architect for approval

Supply, deliver to site and fix the following natural anodized aluminium windows infilled with glass (measured separately) including all necessary frames, aluminium sub frame, transomes, mullions, glazing materials, glazing beads, fixing screws, weather s 150mm x 150mm Reinforced conrete Grade 30 as described lintol A including all necessary reinforcement and formwork to Engineer's m detail Supply and install Powder Coated Aluminium frame overall size B 1200mm x 1200mm high with 6mm thnk green tint laminated sliding glass window to manufacture detail & to arch's approval. Supply and install Powder Coated Aluminium frame overall size 5350mm x 2400mm high comprising with 6mm thick green tint C laminated fixed glass panel window to manufacture's detail & to arch's approval Supply and install powder coated aluminium louvres screeen D overall size 3100mm x 1000mm high to arch's approval and specialist detail Supply and install powder coated aluminium louvres screeen E overall size 2400mm x 800mm high to arch's approval and specialist detail

7.00

No.

2.00

No

1.00

No

2.00

No

2.00

6mm Thick clear glass as described glazing to aluminium framing m2 with and including aluminium beads and glazing materials

9.00

To Collection RM

G1/5/6

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd) DOOR 150mm x 150mm Reinforced conrete Grade 30 as described lintol A including all necessary reinforcement and formwork to Engineer's m detail Supply and install Powder Coated Aluminium frame overall size 900mm x 2100mm high with 8mm thick clear glass casement B door to manufacture details & arch's approval including all accessories INTERNAL WALL FINISHES

3.00

No.

2.00

18mm Cement and sand (1:4) mixed with an approved plasticiser m2 internally as described plain face to wall and column

18.00

Prepare and apply one coat alkali resisting primer and two coats D 'ICI' or other equal and approved emulsion paint as described on plastered surface of wall and column INTERNAL FLOOR FINISHES E

m2

18.00

25mm Thick cement and sand (1:3) as described screed to receive m2 Homogenoues tiles

7.00

200mm x 200mm x 7mm Thick approved Homogenoues tiles F bedded and jointed in cement mortar (1:3) as described and pointed in coloured cement to match tiles to floor INTERNAL CEILING FINISHES

m2

7.00

10mm Thick Boral Fibrous Plaster Board suspended ceiling to Architect's selection or approval complete with necessary m2 G suspended suspention system and necessory accesory works as per Manufacturer's instruction and Architect's approval (provisional)

7.00

EXTERNAL FINISHES WALL 20mm Cement and sand (1:4) mixed with an approved plasticiser externally as described H Wall and columns m2 20.00

To Collection RM

G1/5/7

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd)

Prepare and apply one coat alkali resisting primer and two coats 'ICI' or other equal and approved weathershield paint A Wall and columns FLOOR 50mm thick cement and sand (1:3) as described paving trowelled m2 smooth to apron slab BUILT-IN CABINET Supply and install 4100mm x 1000mm x 850mm high timber built in cabinet complete with drawer and timer rack including all, m C finish with varnish and all other accessories for complete and proper installation as per drawing no 06013SJCC/DD/07-02 (T01) m2 20.00

24.00

5.00

To Collection RM

G1/5/8

Item

Description

Unit

Qty

Rate

Amount (RM)

ELEMENT NO. 5 - GUARD HOUSE (Cont'd)

COLLECTION Page No. G1/5/1 Page No. G1/5/2 Page No. G1/5/3 Page No. G1/5/4 Page No. G1/5/5 Page No. G1/5/6 Page No. G1/5/7 Page No. G1/5/8
GUARD HOUSE

Carried to Summary RM

G1/5/9