Line No.
1
Unit
Unit Rate
SQM
5.8
EXCAVATION:
EXCAVATION for foundation upto required depth below existing ground level in any type of soil except hard rock. Rate to include dressing the sides and bottom, bailing out water if encountered, shoring, strutting, back filling after the construction of foundation, compacting by the side of the foundation and disposal of surplus excavated earth within /outside HPCL's premises to an unobjectionable place, as directed by the Engineer in Charge including spreading, watering and compaction, complete . 4 5 Up to 2 mtr depth Above 2 mtr and upto 4 mtr depth CUM CUM 93.5 121
Line No.
8 9 For 0-2 mtr depth
Description
Unit
CUM CUM
Unit Rate
305 426
SAND FILLING:
10 Supply and filling with clean locally available approved quality sand in layers of 150 mm each including compacting by hand ramming and watering. CUM 275
BOULDER PACKING:
Providing and laying boulder packing / soling using 150 / 230 mm thick naturally formed quarry boulders for foundation trenches / pits etc. (not R R stone) of approved quality, including dewatering contineously of accumulated water from any source and keeping the surface dry for subsequent works, hand packing to line and level, filling the voids with smaller size stone, binding material, hand ramming to desired levels, tools and plant complete etc., all labour, materials as per drawing and Engineer-in-charge directions. 11 12 150 mm thick 230 mm thick SQM SQM 66 102
13
CUM
434
16
SQM
300
Description
Unit
Unit Rate
Providing and laying 60 mm average thickness coping in CC 1:2:4 mix using 6 to 12 mm stone aggregate with 40 mm projection on either side of wall with drip mould. Rate to include 20 mm thick plaster in CM 1:4 for fixing of glass pieces including mixing, providing necessary shuttering, compaction and curing. Thickness of coping at the ends shall be 40 mm and 80 mm at centre.
CUM
3100
REINFORCEMENT STEEL:
Supply, fabrication, hoisting and placing in position HYSD reinforcement bars conforming to IS:1786-Latest Edition Grade Fe 415 as per detailed drawing and specifications including cutting, bending and tying with 18 SWG binding wire complete. The rates shall be applicable for all heights and depths. Payment shall be made as per reinforcement drawings and with theoretical weights only including all authorised laps and hooks.
24
MT
45000
Description
Unit
Unit Rate
1756
Providing and laying brick masonry as above for foundation below DPC level.
CUM
SUPER STRUCTURES:
26 Providing and laying brick Masonry as above for superstructure above DPC level including scaffolding. CUM 1896
RUBLE PITCHING:
29 Providing 230mm thick Rubble pitching including surface dressing, making required slope. Rate to exclude flush pointing which will be paid separately . SQM 153
POINTING:
30 Providing flush pointing in Ruble pitching with 1:3 cement mortar including curing etc. complete. Providing 12mm raised pointing in RR Masonry wall with 1:3 cement mortar including curing etc. complete. SQM 55
31
SQM
62
PLASTERING:
32 Providing and laying average 15 mm thick sand faced cement plaster in single coat in CM 1:4. Rate shall include providing necessary scaffolding, chicken wire mesh at all joints of brick and concrete surfaces, with a minimum overlap of 150 mm in all directions and curing complete. No extra payment shall be made for additional thickness if required to achieve perfect line and level. SQM 105
WEEP HOLES:
34 Providing, fabricating and installing in place, 75 mm dia. PVC Pipes of various lengths & at places as directed at site on the masonry wall for water drainage. RMT 196
Line No.
Description
CHAIN LINK FENCING / BARBED WIRE FENCING:
Unit
Unit Rate
STRUCTURAL STEEL:
ANGLE IRON POST: Supply, fabrication, erection and grouting of 65 x
35 65 x 6 ISA post and supporting angles of specified length in 1:1.5:3 concrete grout at every 2.4 m C/C or as advised. Rate to include fabrication of the post as per the specification, erecting, placing, grouting and painting of the posts with two coats of synthetic enamel over two coats of Zinc Phosphate primer. Paints and primer shall be of SHALIMAR / BERGER / ASIAN make first quality only. Excavation and concrete will be paid separately under their respective items. MT 51000
PIPE RAILING:
Supply and fixing of 40 NB medium quality MS pipes confirming to IS:1239 latest edition for top and bottom railings to angle iron posts for fixing the edges of the chain link fencing. Rate includes fabricating, cutting, bending of the MS pipe, supply and fixing of MS clamps at every post, with nuts and bolts (all proper sized) and painting the railing with two coats of Zinc Phosphate primer and two coats of synthetic enamel paint after proper cleaning / scrapping. Paint and primer used shall be of SHALIMAR / BERGER / ASIAN make 1st quality only.
36
RMT
500
37
SQM
325
39
RMT
2629
Line No.
Description
Supplying, laying, joining and aligning 600mm NB NP3 class RCC Hume pipes conforming to IS:458 Latest Edition below approach road /driveway as directed to the true line and level. Rate to include joining with cement mortar, providing and laying PCC 1:2:4 haunching @ 1m C/C. The PCC haunching shall be minimum 1.1m X 0.3m X 0.35m, curing of PCC haunching. Test certificates from manufacturer shall be submitted and approved by EIC before use. (PCC 1:3:6 shall be paid extra as per relevant item).
Unit
Unit Rate
40
RMT
1337
41
Supplying, laying, joining and aligning 300mm NB NP3 class RCC Hume pipes conforming to IS:458 Latest Edition below approach road /driveway as directed to the true line and level. Rate to include joining with cement mortar, providing and laying PCC 1:2:4 haunching @ 1m C/C. The PCC haunching shall be minimum 0.8m X 0.3m X 0.35m, curing of PCC haunching. Test certificates from manufacturer shall be submitted and approved by EIC before use. (PCC 1:3:6 shall be paid extra as per relevant item)
RMT
563
Line No
Description PART -B : SALES BLDG. / CANOPY FOUNDATION PRE-CONSTRUCTION ANTI TERMITE TREATMENT:
Unit
Unit Rate
42
Providing anti-termite treatment including diluting and injecting Neem base solution and creating a continuous barrier under and alround the column pits, wall trenches, basement excavation, top surface of plinth.
SQM
120
RUBBLE SOLING :
44 Providing and laying 230 mm thick rubble soling including hand packing, filling the interstices with chips, spalls and binding with grit and selected murrum, watering, compacting by hand ramming. SQM 145
MURRUM FILLING:
45 Supplying and filling good quality murrum in layers of 150 mm thick including watering and compacting till maximum compaction is achieved as directed by Engineer In Charge. Compacted volume shall be considered for measurements. CUM 200
PCC BEDDING :
46 Providing and laying Plain Cement Concrete of 1:2:4 mix grade with 12mm and down size HBG as coarse aggregate, river sand as fine aggregate and cement min. 330 Kg./Cu.M. for bedding etc., including providin CUM 2747
BRICK MASONARY:
Providing and constructing brick masonry in CM 1:5 using bricks having minimum compressive strength 35 Kg/cm2 and conforming to IS: 1077- Latest Edition including providing all openings and projections as per the drawing, raking the joints to 1 cm deep, scaffolding, soaking of bricks prior to use and curing etc. complete as per specifications. 115 mm thick in partition walls in CM 1:4. Rate to include providing 75 mm thick RCC 1:1.5:3 bands using 2 nos., 8 mm dia. Torsteel reinforcement at every 1 M height of wall including shuttering. Steel reinforcement shall be paid for separately.
47
SQM
217
Line No PLASTERING:
Description
Unit
Unit Rate
Line No
Unit
Unit Rate
54
Ceramic tiles skirting 150 mm in height using C.M. bedding 1:3 & fixed with neat cement slurry. Rate to include all necessary chipping of brick masonry / concrete so that skirting is projecting uniformly 6mm from plaster thickness. All vertical joints of skirting shall match with floor tile spacing uniformly as per standard specifications and EIC directions.
SQM
1020
Description
Unit
Unit Rate
Providing, mixing and laying 50 mm thick Indian Patent Stone flooring in PCC 1:2:4 mix concrete with 12 mm and down size graded crushed aggregate including providing and fixing 4 x 25 mm size glass strips in 1m X 1m panels, casting the concrete compacting and finishing the surface smooth using cement slurry.
SQM
170
GRANITE SKIRTING :
56 Providing and fixing 10mm thick jet black granite skirting of 100 mm height free from crack fissures & flakes with straight edges & perfect corners fixed at right angles with neat cement paste and finishing the joint with white cement mixed with matching colour pigment. RMT 160
Line No
Unit
Unit Rate
57
SQM
600
58
SQM
750
59
SQM
3000
SILL SLAB :
61 Providing and laying 20 mm thick machine cut & machine polished jet black granite strips over a bedding of 20 mm thick 1:5 CM for window sills. The strips shall be of single piece only as per width of window wall and project 12 mm beyond the face of the wall. SQM 2300
63
SQM
1000
WATER PROOFING
Line No TERRACE:
Description
Unit
Unit Rate
64
Providing and laying integral cement based water proofing of average 100 mm thick as per specifications given below: a) cleaning RCC slab and applying neat cement slurry mixed with waterproofing compound. b) Providing and laying brickbat coba in CM 1:4 mixed with water proofing compound and curing for a period of 24 hours. c) Laying of 25 mm thick PCC 1:1.5:3 mix with 6 mm and down size coarse aggregate SQM 350 and water proofing compound, finishing smooth, making half round vata at the junction of parapet wall and slab and curing for 10 days. Note: Contractor will be required to submit a guarantee in respect of performance of waterproofing for 10 years on a stamp-paper. In addition to this, an amount equal to 10% of cost of waterproofing items shall be retained as retention money for 2 years from the date of completion, which shall be returned with out interest only after successful completion of this period. Water proofing on top of chajja with 25mm thick PCC 1:1.5:3 with 6mm and down size stone aggregate mixed with water proofing compound, finishing smooth, making half round vata at the junction of chajja and wall, curing etc. complete.
65
SQM
220
Description
Unit
Unit Rate
Providing and applying 3 coats of white wash to plastered and concrete surfaces including providing necessary scaffolding, surface preparation, mixing DDL binder, blue etc. complete as per IS: 712Latest Edition. If additional coats are required to obtain uniform and smooth finish, the same shall be carried out at no extra cost.
SQM
10
APEX PAINT:
68 Providing and applying 2 coats of apex paint to all exterior surfaces over a coat of premier as per manufacturer's specification including necessary scaffolding, curing etc., complete. If additional coats are required to obtain uniform and smooth finish, the same shall be carried out at no extra cost. SQM 80
71
SQM
85
Description
Unit
Unit Rate
Providing and applying 2 coats of Sandtex matt paint of SNOWCEM INDIA make and of required shades on all surfaces and heights to give an even shade including primer coat of snowcem after thoroughly brushing the surface free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth etc., all material, scaffolding and labour complete.
SQM
70
75
SQM
65
76
KG
50
77
KG
55
78
Providing and fixing Aluminum glazed door/ fixed glazing with 25 micron coloured anodized aluminum section minimum wall thickness of not less than 2 mm with extruded built up section of approved make and weight ratio joints mitred ad joint with heavy duty aluminium pressure die cast cleats with fins to match the section of frames conforming to approved section and shutterconforming to approved SQM 3000 sections and glazed with 12 mm thick glass fixed to shutter with aluminium snap beading and neoprene / PVC gaskets/CP brass/stainless steel screws and fixed to the wall with requisite rawl plugs and screw or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with requisite PVC/neoprene felt/polysulphide sealant/sillicon sealant etc. all complete as per architectural drawing. Aluminium anodised shop front (Doors & fixed glazing) with frames at top & bottom and at two ends of INDAL make o
Line No
Unit
Unit Rate
79
Providing and fixing double action hydrauclic floor springs of approved brand ( HARDWYN/EVERITE) conforming to IS:6315 for aluminium doors. Rate to include cutting of floors as required, embeding in floors and cover plates etc. complete as per specifications.
Nos
1900
80
ALUMINIUM PANELLED DOOR: Providing and fixing 25 micron colored anodised single leaf aluminium door with minimum wall thickness of not less than 2 mm, joints mitred ad jointed with heavy duty aluminium pressure die cast cleats with fins to match the section of frames conforming to INDAL section 9221or equivalent section (Jindal/HIndalco) and shutter conforming to INDAL section 9200, 9201, 9202 and 9240 or equivalent section (Jindal/Hindalco), fully panelled with 9 mm thick prelaminated 3 layers medium density (exterior grade) particle board Grade-1, type -II conforming to IS:12823 bonded with phenolformaldehyde synthetic resin of approved brand and manufacturer fixed to shutter with aluminium snap beading and neoprene / PVC gasket / CP Brass SQM 2800 /stainless steel screws fixed to the wall with requisite rawl plugs and screw or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with requisite PVC/neoprene felt/polysulphide sealant/sillicon sealant etc. all complete as per architectural drawing. Aluminium door section of INDAL make or equivalent make with the following section: Main frame on all sides 9221 -101.5 x 44.45 x 2.5 of weight 1.975 kg/mtr. Shutter vertical frame9202 - 50 x 44.5 x 2.5 of weight 1.202 kg/mtr. Shutter top frame 9201- 50x44.5x2.5 of weight 1.299 kg/mtr. Shutter middle frame - 9129-50x45x2.5 of weight 1.292 kg/mtr. Shutter bottom frame - 9200-100x44.5x2.5 of weight 1.974 kg/mtr. Door handle -5140 - 100x 30 x 2.5 of weight 0.988 kg/mtr. Glazing clip 4660 - 17.8 x 17.6x 1.3 of weight 0.169 kg/mtr.
Description
Unit
Unit Rate
ALUMINIUM WINDOWS(OPENABLE):
Providing and fixing 25 micron colour anodised aluminium glazed windows with 4 mm glass & extruded built up section of wall thickness not less than 1.5 mm and approve make with glass panel fixed to side hung shutter with aluminium snap beading and neoprene / PVC gasket / CP Brass / Stainless Steel screws fixed to the wall with requisite rawl plugs and screw or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions,at top,bottom and sides with PVC/neoprene felt/polusilphide sealant /silicon sealant including heavy duty handle cum locking arrangement etc. all complete as advised by EIC. Al. window section of INDAL make or equivalent approved make with following section: Outer frame -2082 - 34 X 44.45 X 28.5 X 2 of weight @ 0.554 Kg/Mtr Shutter frame - 4124 - 34 X 44.5 x 28.5 X 1.5 of weight @ 0.494 Kg/Mtr Mullion - 9139 - 57 X 34 x 25 X 2 of weight @ 0.810 Kg/Mtr Cleat angle - 2081 - 50 X 50 x 4.9 of weight @ 1.177 Kg/Mtr Glazing clip : 4125 - 31 X 17.5 X 1.2 of weight @ 0.184 kg/mtr 82 Same as above but Aluminium sliding windows SQM 3000
81
SQM
2600
84
SQM
3500
Line No
Description
Glazing clip : 4125 - 31 X 17.5 X 1.2 of weight @ 0.184 kg/mtr Bottom 900 mm height shall be with 9mm thick both side prelaminated NOVOPAN board. The door shall be provided with Al. handle towerbolt, locking arrangement etc. complete .
Unit
Unit Rate
85
ALUMINIUM PANELLED DOOR WITH BISON LAM: Providing and fixing aluminium door to concrete and brick work with minimum wall thickness of not less than 2 mm , with outer door frame section of frames conforming to INDAL series section 9221 or equivalent section( Jindal/HIndalco)and Door shutter conforming to INDAL section 9200, 9201, 9202,9219 and 9240 or equivalent section (Jindal/Hindalco) with 9 mm thk Pre laminated both side Bison lam sheet ( Cement particle Board)fixed to shutter with aluminum snap beading and Neopren/ PVC gasket/CP Brass/SS screws .fixed to the wall with requisite rawl plugs and screw or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top , bottom and sides with requisite PVC/neoprene felt/polysulphide sealant/sillicon sealant etc all complete including hard ware such as tower bolts from inside and Aluminum handle and Aluminum aldrop on both sides etc complete as per architectural drawing. STEEL WINDOWS:
SQM
3200
86
Supply, fabrication and fixing of MS glazed windows using approved Z sections with 4mm plain glass including providing grill with 12mm sqare bar @100mm c/c, painting with two coats of red oxide primer and two coats of sysnthetic enamel paint, handle, stay arrangement etc. complete.
SQM
2100
STEEL DOORS :
87 Supply, fabrication and fixing of MS door using 35x35x5mm angle frame and 25x25x3 mm angle members including bracings with 16 gauge MS sheet stich welded to Door shutter frame complete as per approved drawing, painting with two coats of red oxide primer and two coats of synthetic enamel paint, handle, stay arrangement, tower bolt etc. complete. SQM 2280
FLUSH DOOR :
Providing and fixing solid core flush door in single leaf 35mm thick commercial plywork of seasoned wood without ventilator. Door frame to be made of 60mm x 100mm teak wood with wrough iron hold fasts. Door to be fitted with brass fitting-hinges, handles on both sides, tower bolts etc. complete. Frame to be painted in three coats of sysnthetic enamel paint over a coat of wood primer including scrapping, surface preparation etc. complete. Door (leaf) to be laminated on both sides with laminations 1.5 mm thick and grey in colour of approved make/brand. 88 89 (i) door size 900mm x 2100mm (ii) door size 750mm x 2100mm NOS NOS 3168 3916
Line No
Unit
Unit Rate
90
Providing and fixing door shutters made of Aluminium panel sheets 3"x1.5" aluminium styles and rails and EPDN rubber for pasted sealing with Aluminium frame, hinges, handles, tower bolts etc., complete.
SQM
2500
ROLLING SHUTTER :
Supply, fabrication and fixing of MS rolling shutter of the following specifications including grill window of 300 mm height at eye level for visibility even in closed position. Code: Conforming to IS 6248-1979 Type: Self Coiling type (manual), Curtains: Interlocking cold rolled lath section of 0.8 mm thickness. Lock plate: MS sheet of 3.15 mm thick reinforced with MS angles of 35 X 35 mm. Guide channel: MS sheets of 3.5 mm thick. Bracket Plate: MS sheet of 0.9 mm thick hood covers. Locking handle : To be provided suitably. Rate shall include providing and fixing holdfasts and painting two coats of enamel paint of approved make and shade over two ocats of zinc phosphate primer. Grill in rolling shutter
91
SQM
1600
92
SQM
2260
Line No
Description
DISPLAY SHELVING / STORAGE
Unit
Unit Rate
DISPLAY SHELF:
Providing & fixing (as shown in standard drawing) in position 12 mm thk plain glass of Modi Guard / Asahi make with polished edges in the grooves between the 25 mm thick exterior grade MDF board planks at 375 mm C/C & 300 wide. The vertical memebers of the MDF planks are at every 1200 mm C/C. The exposed surface of the MDF board shall be finished with 1.5 mm thick lamination of approved colour & combination of colours with teak wood beadings on edges. The approved brand for the lamination shall be Formica / Greenlam / Sundek. The shelf shall be movable type fixed with wheels. Same as above but for storage and shelves shall be with 25mm MDF board
93
SQM
3030
94
SQM
7110
MISCELLANEOUS
95 Providing & fixing MS fan hooks with 16 mm dia MS bar bent to shape with hooked ends in RCC Slab during laying including painting the exposed portion. Nos 95
MORTICE LOCK:
96 Providing & fixing GODREJ or equivalent make six lever lock (Cylindrical/ Round Head ) including all necessary hardware etc. NOS 855
97
DOOR CLOSER :
Providing and fixing door closer of Hardwin/Everite make size no. 2
NOS
1765
98
MT
51000
102
KG
55
Line No
WATER CLOSETS
Unit
Unit Rate
EUROPEAN TYPE :
Supplying and fixing coloured (pastel colour) vitreous china European type water closet comprising of the the following accessories including cutting and making good the walls & floors wherever required complete as directed by Engineer In Charge A) Coloured (pastel colour) viterous china pedestal type European water closet with P or S trap of Hindware sanitaryware standard model or equivalent approved make as per the direction of Engineer In Charge. B) 15mm NB brass angle valve as per ISI of approved brand as per the direction of Engineer In Charge C) 15 mm NB CP inlet connection with Brass unions at the ends. D) Commander make or equivalent matching colour polypropylene seat cover with necessary brass hinges and rubber bushes etc. E) WC connector with neoprene rubber etc. F) 10 litres capacity low level plastic cistern of matching colour parry slimline make or approved equivalent with necessary fittings, brackets, screws, etc. all complete.
103
NOS
3525
Line No
Unit
Unit Rate
104
Supplying and fixing coloured (pastel colour) vitreous china Orissa Pan type water closet comprising of the the following accessories including cutting and making good the walls & floors wherever required complete as directed by Engineer In Charge A). Coloured (pastel colour) viterous china 580 mm orissa pan water closet of Hinduatn sanitaryware or any equivalent make with P or S trap B) 10 litres capacity hi-grade NOS 3767 engineering plastic low level flushing cistern of matching colour parry slimline make, model no. 8068 or approved equivalent make with necessary fittings, brackets, screws etc. all complete C) 32 mm PVC flush pipe 10Kg/sq.cm quality of approved length with necessary fittings, clamps etc D) 15 mm NB CP inlet connections with brass union at the ends E) 15mm NB brass angle valve as per ISI of approved brand as per the direction of Engineer In Charge F) WC connector with neoprene rubber.
URINALS :
105 Supplying and fixing coloured (pastel colours) viterous china flat back urinal of size 300mm X 400mm with integrated overflow of Hindustan Sanitary or equivalent approved make with CP flush valve, CP pipe connection, CP waste coupling, CP Brass bottle trap, 32 mm PVC waste line of required length etc. all complete as per the direction of Engineer In Charge. NOS 1200
107
NOS
2225
MIRROR :
108 Providing and fixing bevelled edge mirror of superior glass of 5.5 mm thick & 600 x 600 mm size of BELGIUM GLASS or any other equivalent make, 3mm thick felt backing or 6 mm asbestos sheet or with wooden beads allround of specified size and fixed with wooden plugs with CP brass screws and cup washers etc all complete as directed by Engineer In Charge. NOS 600
Description
Unit
Unit Rate
200
Providing and fixing readymade CP brass soap tray near wash basin with CP brass screws of approved make.
NOS
Line No
110
Unit
Unit Rate
510
NOS
TOWEL RAIL:
112 Providing and fixing CP brass towel rail of 20 mm dia and 600 mm long including all accessories such as brackets (coloured), fixed and anchoring etc. complete as directed. NOS 400
CONCEALED GI PIPING :
Providing & fixing followg size medium grade GI pipes of TATA/ JINDAL make conforming to IS:1239 concealed in the walls/under the concrete floors including making chases in the walls/concrete floors,fixing with clamps at every 1m C/C, necessary tees, bends, elbows, plugs, nipples, unions, testing of pipelines for leaks upto a pressure of 6 Kg/sq cm. , painting the pipes with hot bitumen, wrapping the pipes with hessian cloth and making chases of the walls good after piping complete. 117 15 mm nominal bore 118 20 mm nominal bore RMT RMT 125 140
EXPOSED GI PIPING :
Description same as above but providing, laying and fixing GI medium grades pipes in open on brick or RCC surface with the help of MS 'U' clamps at every 1 m and at every turn. 119 15 mm nominal bore 120 20 mm nominal bore 121 25 mm nominal bore Providing & fixing following size brass full way gate valve ISI marked & of Leader/GG make or approved equivalent as directed by Enginner In Charge. 122 25 mm dia 123 15 mm dia NOS NOS 600 400 RMT RMT RMT 105 115 170
Description
Unit
Unit Rate
Supplying and installation of HDPE water tanks Sintex / Fusion / Polycon make of 1000 litre capacity including 300 mm high brick masonry pedestal of 230mm thick in CM 1:5, providing 75mm thick RCC 1:2:4 slab with reinforcement 8mm tor @150mm c/c, lifting the tank, making all necessary GI connections to inlet, outlet, and overflow nozzles and cleaning the tank before commissioning.
NOS
5650
Line No
126 80 mm dia
Description
Unit
RMT
Unit Rate
210
UPVC PIPES :
Providing and laying unplasicides polyvinyl chloride (UPVC) pipes confirming to IS : 4985 including all necessary fitting to IS/BS 4514 and other accessories including connections etc., complete as per drawings or as directed at site. 127 90 mm dia 4Kg/sqcm 128 110 mm dia 4Kg/sqcm 129 160 mm dia 4Kg/sqcm 130 250 mm dia 4Kg/sqcm RMT RMT RMT RMT 150 165 275 420
SEPTIC TANK :
Providing & constructing septic tank of size 1200x2000x1800mm depth with excavation, PCC1:4:8 100mm thick bed, 345/230mm thick brick masonry wall in CM 1:5, RCC1:2:4 100mm thick slab with 8mm tor steel @150c/c both way, 115mm thick baffle wall with RCC beam at bottom,12mm thick smooth cement plaster with water proofing compound inside and exposed outside portion, providing 600mm X 600mm size medium duty CI cover, providing 75mm dia PVC vent pipe etc. complete.
135
NOS
18140
SOAK PIT :
136 Providing and constructing soak pit of 2.5m dia (internal) and 2m depth as per drawing. NOS 8370
ELECTRIFICATION
Line No
Description POINT WIRING FOR LIGHT / FAN WITH MODULAR PLATE SWITCHES ANCHOR / MK / LEGRAND:
Providing and laying point wiring in concealed conduits for the following points using specified 1100V grade PVC insulated, FRLS multistranded 3 x 1.5 sqmm copper conductor wires. Rate to include supplying, laying and securing in position in roof slabs and brick walls or concrete columns 25 mm dia rigid PVC conduits of approved make with necessary accessories and junction boxes/pull boxes. Providing and fixing in the brick wall flush type metal switch boxes of approved make, shade and sufficient size to accommodate all 6A Modular switches / 3 pin socket, screws, holders, ceiling roses and the fan regulator wherever required. Rate to include wall chasing and rough plastering. Providing and fixing single pole 5A modular plate switches of MK or ANCHOR ROMA make of approved colour. One switch shall be provided for each light and fan point. Rate to include providing main circuit wiring from DB to switch boards with 2.5 sqmm copper wire also. Same as above but for 5A socket controlled by one 5A switch on the same lighting board
Unit
Unit Rate
137
NOS
540
138
Nos
865
Same as above but for 5A socket controlled by one 5A switch 139 independently mounted including providing wiring with 3 runs of 1.5 sqmm pvc insulated copper wire through PVC conduit Same as above but for 5/15A socket controlled by 15A switch independently mounted including providing wiring with 2 runs of 2.5 140 sqmm and 1 run of 1.5 sqmm PVC insulated copper wire through PVC conduit.
Nos
775
Nos
375
Line No
Description
Unit
Unit Rate
Same as above but for AC point with 2 runs of 4 sqmm (P&N) and 1 run of 2.5 sqmm (earthing) PVC insulated, FRLS multistrand copper cable in 25 mm dia PVC conduit from MCBDB to 20 A power socket. The conduit 141 shall be partly/fully concealed in all types of wall, ceiling etc. complete with all accessories, wiring, termination, connected civil works, rough plastering etc. including supply and fixing of 20A industrial socket controlled by 20A SPMCB of MDS/HAVELS make. Supply, laying, and commissioning of wiring using following sizes of PVC insulated, FRLS, unsheathed, multistraned copper wire drawn in PVC conduits. Rate to include supply of 16 GI fish wire, conduits & accessories, wiring, terminations etc. complete. 142 143 4 runs of 10 sq mm and 1 run of 6 sqmm copper wire in 40 mm dia PVC conduit from panel to Distribution Boards. 4 runs of 6 sqmm and 1 run of 4 sqmm copper wire in 32 mm dia PVC conduict from panel to Distribution Boards.
NOS
695
RMT RMT
285 170
CEILING FANS :
144 Supplying and fixing of the ceiling fans of Crompton/GE/Polar with detail as below : Sweep Colour Down Rod Regulator :1400 mm :White : Clear 300 mm long : Electronic type ANCHOR/MK make NOS 1960
EXHAUST FANS
Supply, fixing and commissioning of 305 mm dia. Exhaust fans 145 including bird louvers, frame works and other civil works like chipping and making the surface good etc. 146 NOS 1570
NOS
1350
1 x 36 W tube light fitting with lamp Philips make cat no. TCS 19/136 HPF or equivalent . 1 x 60W spot light luminaire with 1 meter track including lamp Philips make cat no. DGN 451 or equivalent for display shelving 1 x 60 W Bulk head luminaire including lamp Phillps cat no. NXC 101 or equivalent (Outside building).
150 Angle holder Anchor make including lamp 60W (Toilets). 151 1 x 36 W tube light fitting including lamp Phillps cat no TMS 21/136 HPF or equivalent ( stores, service area)
Line No
152
Description
2 x 36 W tube light fitting including lamp Phillps cat no TBS 50/236 HPF or equivalent (for false ceiling area) Corner/wall slim (corner luminar with lamp , reflector clear reeded acrylic cover Acrade make) as follws.
Unit
NOS
Unit Rate
2760
Line No
153 ACW/N -1 X 18W 154 ACW/N -1 X 36W
Description
Unit
NOS NOS
Unit Rate
710 950
Decorative luminar with lamp reflector, opal/clear reeeded acrylic cover Arcade make as follows: 155 AMA-1 X 18W 156 AMA-1 X 36W Philiphs Energy essential as follws 157 11 W 158 14 W 159 18 W Supply and fixing of spot light in sales room opposite to sales display shelving using Philiphs make Catalog 303-21 X 12 V , 50 W halogen 160 Dichotic or equivalent inclusive of necessary connection , accessories , lamp etc. NOS NOS NOS 230 290 320 NOS NOS 660 750
NOS
1000
Line no.
Unit
Unit Rate
164
NO
2100
165
NO
31500
166
NO
43500
167
NO
50000
168
NOS
5500
169
NOS
4900
170 171
RMT RMT
200 145
Line no.
172 173 174 4C X 6 sqmm AL cable 4C X 2.5 sqmm copper cable 3C X 2.5 sqmm copper cable
Description
Unit
RMT RMT RMT
Unit Rate
105 110 100
End termination of following cables with double compression NFLP gland and crimping sockets 175 176 177 178 179 3.5C X 35 sqmm AL cable 4C X 16 sqmm AL cable 4C X 6 sqmm AL cable 4C X 2.5 sqmm copper cable 3C X 2.5 sqmm copper cable End termination of following cables with double compression FLP gland and crimping sockets 180 3C X 2.5 sqmm copper cable YARD LIGHTING: CABLE TRENCH: Excavation in any type of soil including WBM / asphalt up to 600mm depth and 300mm wide including supply and laying 150mm thick sand on top and bottom of cable, supply and laying bricks laid flat on top, back filling trench etc. complete. Junction box for yard light pole; Supplying and fixing 150mm x150mm x125mm weather proof out door junction box fabricated out of 14 SWG CRCA sheet of IP 54 category of protection with rubber gasket and having locking arrangement including required connector, 10A SPMCB. Yard light pole: Supply, Fabrication and Erection of 7 mtrs high galvanised Pole having a base plate of size 300x300x16 with 1000 mm long 40mm MS pipe suitable for mounting 1 no. fixture as per attached detail specificaton. Job also includes foundation for the same. Pole to be made up of 100mm dia MS pipe of 3.0 m length, 80mm dia MS pipe of 3.0m length and 50mm dia pipe of 1.0m length with 65mm dia cap, gusset plates, etc., complete. Same as above but with double arm Street light fitting Supply of street light fixture of WIPRO make cat no. WST 65250 1 x 250W metal hallide lamp including lamp single piece die cast aluminium housing complete with all accessories, choke, acrylic cover etc. complete. NO 125 NO NO NO NO NO 190 165 115 140 105
181
RMT
160
182
NO
706
183
NO
6500
184
NO
7000
185
NO
5450
Line no.
186
Description
Providing and fixing MS angle / channel supports and edge protection for trench etc. including providing hold fast, painting with two coats of red oxide primer and two coats of synthetic enamel etc.
Unit
Unit Rate
46
KG
187
Providing pipe electrode pipe earthing as per IS 3043 and attached drawing including excavation supplying 50mm dia GI pipe medium quality, filling the pit with alternate layers of charcoal and salt, back filling, constructing chamber 400mmx400mx400mm internal size with 100mm thick PCC 1:2:4, providing CI cover with frame etc. complete. Supply and fixing 10 SWG copper wire for earthing connection to pumps, canopy columns etc. Supply and fixing 25x3 copper flat for earth connection of panel Providing and fixing 6mm thick MS chequered plate including making holding arrangements, painting with two coats of red oxide primer and two coats of synthetic enamel paint etc. Supply and fixing 20mm thick ISI marked rubber mat.
NO
2203
188
KG
290
189
KG
300
190
KG
60
191
SQM
260
Line no.
Unit
Unit Rate
192
Supply and filling murrum in 200mm thick layers including levelling with doser, watering, Compacting each layer with 8/10 MT road roller to obtain field dry density 92% of MDD, Dressing top layer to the required slope, Testing of murum sample for OMC & MDD and testing of field dry density by core cutter for checking compaction. Payment will be made only for compacted thickness.
CUM
215
RUBBLE SOLING :
193 Providing and laying dry trap rubble stone soling 230 mm thick including hand packing, filling the interstices with chips, spalls and binding with grit and selected murrum, watering, comacting by power rolling with 8/10 ton roller complete. SQM 156
WATER BOUND MACADUM : Providing and laying WBM in layers of 75 mm compacted thickness each using well graded stone aggregates of 40 mm to 63 mm size of approved quality. Rate includes spreading metals, hand packing, filling the interstices with spalls, chips, and approved quality binder and rolling each layer with 10 MT power roller with simultaneous watering till the metal is bound by the water binder paste to achieve maximum compaction, finishing the surface to proper grade and level. Rate also to include carrying out the following tests on aggregates and test result to be submitted to EIC before use and shall meet the following stength requirements. LA Abrasion value:40% ,Flakiness Index : 15%.
First Layer 75 mm thick Second Layer 75 mm thick Third layer of 75mm thick using 53 to 22.2 mm size stone metal RCC DRIVEWAY : Providing and laying 150mm thick RCC driveway with 1:1.5:3 nominal mix using 20mm and down size crushed stone aggregates in panels using slotted MS channel shuttering, machine mixing, vibrating with screed board vibrator, pond curing for 14 days, vaccum dewatering, finished with power trowelling. Concreting shall be carried out as per IS 456. Rate shall also include providing approved quality polythene paper below the driveway, constructing horizontal and longitudinal vatas with 1:10 CM for curing, levelling depressions if any in the base with 20mm stone aggregates and stone dust.
57 53 48
197
CUM
3740
Line no.
Description
Proper slope to be provided in driveway for easy draining of rain water. Job shall include cutting grooves 4mm wide and 20mm deep by machine and filling the groove with polysulpide compound, providing 12mm thick Shalitek board in the joints between precast cover of pipeline trench or top slab of U/G tank and RCC driveway. Testing of cube, reinforcement steel, stone aggregates, sand, cement etc. to be carried out by contractor at no extra cost.Tubing, ducting, trenching and other necessary embedded items in concrete shall be checked with architect/HPCL representative before concreting. The cement consumption for 1:1.5:3 mix shall be 410 kg/cum and compressive strength shall be 140 kg/sqcm and 230 kg/sqcm after 7 days and 28 days respectively. Rate shall be excluding reinforcement steel which shall be paid separately.
Unit
Unit Rate
198
Same as above but without vaccum dewatering and power trowelling with 1:1.5:3 nominal mix
CUM
3640
STEEL REINFORCEMENT :
Supply, fabrication and placing in position High yield strength deformed bars conforming to IS 1786 - Latest edition grade FE 415 as required and directed at site for driveway including cutting, bending, placing in position and tying with 20 SWG binding wire, complete. Quantity shall be measured as per reinforcement drawing and with theoretical weights including all authorized laps. Unauthorized chairs, spacers and laps will not be measured and paid for. Reinforcement to be provided
200
MT
45000
201
ASPHALTING : Providing & laying 50 mm compacted thickness premix asphalt carpet and 12 mm thick seal coat (total compacted thickness 62 mm) on top of WBM surface as per procedure given below.
1) Applying a tack coat of hot 80/100 asphalt to it @ 5 kg for 10 sqm. for bitumenous surface and 10 Kg for 10 sqm. for non bituminous surface after thorough cleaning of WBM surface. 2) Spreading a layer of premix at the rate specified below in (a) and roll to full compaction with 10 MT roller to the required slope and compacted thickness of this layer shall be 50mm. 3) Spreading a layer of seal coat and rolling with 10 MT roller to the required slope and the total compacted thickness shall be 62mm. Asphalt required for seal coat is 6.8 Kg for 10 sqm.
SQM
213
Line no.
Description
a) Materials to be used per 10 sqm of 50 mm thick premix asphalt carpet : 20mm stone metal: 0.34 cum 12mm stone metal : 0.17 cum. Asphalt 80/100 @ 2.5 KG
Unit
Unit Rate
202
Surface preparation through cleaning of the exposed surface by wire brush to remove the loose sand, pebbles and any inorganic material. Applying tack coat of 80/100 bitumen @ 9.5 Kg / 10 sqm, after surface preparation as per above. (Total compacted thickness of 112 mm) (a) Providing 75 mm thick BT concrete using 1 Cum. of 40 mm hard broken granite metal (machine crushed) with 35 Kg. 80/100 grade bitumen and 0.13 CuM. of 12 mm hard broken granite aggregate for 10 Sqm. well mixed in machine mixer in correct proportion including supply of material. Cost of machine mixer, power rolling with 10 tonnes power roller and all labour charges etc., complete in all respect of stisfaction of H.P.C.L.(b) Providing 25 mm thick Black top surface using 0.27 CuM. of 12 mm hard broken granite chips (machine crushed) with 25.00 Kg. of 80/100 grade bitumen per 10 SqM. including cost of machine mixing, power rolling with 10 tonnes power roller and all labour charges etc., complete in all respect of satisfaction of H.P.C.L. (c) Providing 12 mm thick Black top seal coat using 0.09 CuM. of 6 mm hard broken granite chips with 10 Kg. of 80/100 grade bitumen per 10 SqM. including sprinkling of sand over the black top, supply of material, machine mixing and rolling with 10 ton roller, labour charges etc., to the satisfaction of H.P.C.L.
SQM
345
PAVER BLOCK :
Providing and laying approved brand / make 80 mm thick cement coloured paving blocks of M40 grade over a bed of 50 mm thick well compacted sand bed laid over well prepared sub base to the required line and level including all materials, labour, machinery, transportation etc., paving blocks should have chamfered top edges of not less than 4 mm and shall be laid and interlocked with a minimum of 2 mm gap which in turn packed with sand, compacting with plate vibrator etc.complete. Edge restraint with RCC 1:1.5:3 will be paid separately.
203
SQM
470
204
SQM
525
HUME PIPE :
Supplying, laying, joining and aligning following size NP3 class RCC Hume pipes conforming to IS-458 Latest Edition below approach road whereever directed. Rate to include joining with cement mortar, excavation up to required depth and providing and laying PCC 1:2:4 haunching @ 1m C/C. Test certificates from manufacture shall be submitted and approved by EIC before use. 205 206 300mm NB 225mm NB RMT RMT 450 390
Line no.
207 150mm NB
Description
Unit
RMT
Unit Rate
310
INSPECTION CHAMBER :
Providing and constructing following size inspection chambers with 230mm thick brick masonry in 1:5 cement mortar, excavation, 75mm thick PCC 1:4:8 bed, plastering with neat cement finish, providing 12mm thick MS plate cover with 35X35X6 angle stiffner and 50X50X6 angle frame etc. complete. 208 209 600mm X 600mm internal size X 700mm depth 450mm X 450mm internal size X 700mm depth NO NO 4490 4038
Line no.
Unit
Unit Rate
210
NO
6000
211
KM
24
EXCAVATION IN SOIL :
Excavation for foundation upto 4m depth below existing ground level in any type of soil except hard rock. Rate to include dressing the sides and bottom, bailing out of water if encountered, shoring, strutting, backfilling after the construction of foundation, compacting by the side of the foundation and disposal of surplus excavated earth within / outside HPCL's premises to an unobjectionable place, as directed by the Engineer in Charge including spreading, watering and compaction, complete.
212
CUM
110
PCC 1:4:8 :
215 Providing and laying PCC 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate) with 40mm and dowm Size stone aggregates in foundation trenches, including compacting, curing etc. complete. CUM 1369
R.C.C. 1:1.5:3
Providing and laying RCC 1:1.5:3, providing steel or plywood shuttering with proper supports, removal of form work as per IS code, preparing mix using mechanical mixer, compacting using mechanical vibrator, curing with potable water for 14 days etc. complete. Work shall be carried out as per IS 456 latest edition. Rate shall be excluding reinforcement steel which will be paid separately vide item no 5. 216 Bottom raft Top slab (Rate shall be including providing Polythene paper below the slab, providing 12 mm thick shalicatek board in jionts to separate pieces. Top slab to be cast in 4/3 pieces). CUM 3240
217
CUM
3460
Line no.
Unit
Unit Rate
218
Supply, straightening, cutting, placing in position as per drawing, binding at every intersection with two strands of annealed 20 gauge steel wire, HYSD bars Grade Fe-415 conforming to IS 1786.
MT
45000
TANK INSTALLATION :
Installaion of HPCL supplied Tanks of following capacity in earth pit / under driveway including lowering, providing holding down arrangement, Hydrostatic testing to pressure of 3.5m water column, supplying & filling with water with necessary 50 mm dia pipe & on successful completion emptying out the water from tank, cleaning & drying the inner surfaces with cloth / cotton waste etc., doping with three coats of tank mastic paint of STP make and hot 30/40 bitumen (total doping thickness 3mm), fixing all fittings as required. 219 220 221 22 KL 16 KL 9 KL NO NO NO 10400 9000 8450
BRICK MASONRY :
222 Providing 345mm thick brick wall with bricks having compressive strength of minimum 35 kg/sqcm in cement mortar 1:5 (1 cement: 5 coarse sand) in foundation and superstructure, plain or curved including providing necessary scaffolding, raking the joints on both faces, curing for 7 days etc. complete. CUM 1825
:
SQM 100
Providing and laying smooth cement plaster of 15mm thick in single coat in 1:3 cement mortar mixed with water proofing compound to interior walls including providing necessary scaffolding, curing etc. Complete.
SAND FILLING :
224 Supply and filling coarse river sand in layers of 200mm thickness inside masonary pit / earth pit after tank installation including watering, compaction etc. complete. CUM 300
MANHOLE COVER :
225 Supply, fabrication and fixing of manhole cover of size 900x900 mm with 65x65x6 angle frame and 16mm thick MS plate with 50x50x6 stiffener including painting with two coats of red oxide primer and two coats of synthetic enamel paint. The manhole cover to be fitted with providing and fixing 3mm thick RAF Gasket packing (Champion make) of 750mm dia. PUMP ISLAND AND INSTALLATION OF PUMPS PUMP ISLAND NO 8975
Line no.
Description
Construction of pump island 1m wide with 230mm thick brick masonry in CM 1:5, 12mm thick plastering in CM 1:4 roughened to receive granite tiles including excavation, 75mm thick PCC 1:4:8, sand filling and constructing the wall 300mm above the finished driveway level and 600mm below the finished driveway level . INSTALLATION OF DISPENSING PUMPS Installation of MONO / DUAL / MPD pumps on pedestal including providing & fixing MS angle frame 65x65x6 & connecting suction pipe, electrical, earthing connections to the pump. Job includes providing, fabricating and grouting in proper level MS angle frame made out of 50 x 50 x 6mm MS angles with holdfast etc. complete.
Unit
Unit Rate
226
RMT
1270
227 228
Installation of MONO / DUAL pumps Installation of MPD pumps PIPE LINES Supplying & Laying 'C' Class MS ERW black steel screwed pipeline conforming to IS:1239 (part I) latest edition to the required slope & alignment with heavy duty MS fittings like elbows, tees including doping pipe line with 1 Coat of red oxide primer and 3 coats of shalimastic HD THIXOTROPIC of STP cold applied anti corrosive treatment after preparing the surface as per manufacturer specifications.The joints are to be made leak proof by using jointing materials like Litharge, Glycerin, Shellac, holdite. The pipes laid above ground shall be painted with two coats of synthetic enamal over two coat of zinc chromate primer of approved quality and shall be colour coded as per instruction of EIC. The pipeline shall be tested at a pressure of 5 kg/sqm.
NO NO
700 2035
Description
Unit
Unit Rate
236
Providing and fixing 20 mm thick pre polished water cut black granite slab for pump island top including providing 25mm thk bed cement mortar 1:5 (1 cement : 5 coarse sand), floating cement slurry and finishing the joints with white cement mixed with matching colour pigment.
SQM
2575
237
Providing and fixing 10 mm thick pre polished water cut black granite tiles for pump island dado including providing 12mm thk bed cement mortar 1:4 (1 cement : 4 coarse sand), fixing the tiles with neat cement paste and finishing the joints with white cement mixed with matching colour pigment.
SQM
1530
PIPELINE TRENCH
Providing pipeline trench as per drawing with internal size 300mm wide x 400mm depth including excavation, 100mm thick PCC 1:4:8, 230mm thick brick masonry in 1:5 CM, 12mm thick plastering inside in 1:4 CM, filling trench with sweet river sand, 150mm thick RCC 1:1.5:3 cover with reinforcement 10mm tor @ 125mm c/c both way as main steel and 8 mm tor ring as destribution, 50x50x6 angle edging, curing etc. complete. SAME AS ITEM NO 238 WITH INTERNAL SIZE OF 450MM WIDE X 400MM DEPTH.
238
RMT
1290
239
RMT
1700
Line no.
Unit
Unit Rate
Dismantling of existing pump island 1m wide and carting away 240 debris including removal of pump and disconnecting pipeline etc. complete. 241 Dismantling of existing building/structures 242 Dismantling of RCC roof, beam, column including carting away debris
243 Removal of AC sheet from roof and stacking as directed by EIC 244 Removal of structural steel and stacking as directed by EIC 245 246 Dismantling of brick masonry / PCC / RR masonry including carting away debris Removal of MS / Aluminium doors / windows / fixed glazing and stacking as directed by EIC.
Shifting of GEB / AEC Main, laisoning with AEC / GEB officials, including payment of all incidental charges etc., all complete ( 247 Payment made to AEC / GEB shall be reimbursed to contractor by HPCL on submission of original receipt). Removing of existing ID sign carefully without damage and shifting the same or refixing the same at new place within the 248 primises as per HPCL instructions. Job includes making necessary electrical connecitons etc., complete. Removing the existing yard light poles including removing of 249 light fixtures carefully and with out damage and stacking at designated place as directed by HPCL. Trimming the branches of trees above a minimum height of 4m 250 from ground level and carting away the same from the site when and whenever required as per instruction of HPCL Removing existing chainlink / barbed wire fencing including 251 removing the grouted angles, rods etc., and stacking the same carefully as directed. Breaking of RCC slab over tank and driveway by manual means 252 or by using pneumatic breaker and carting away the debris to unobjectionable place outside RO premises. Removal of existing paver blocks carefully and without damage 253 and refixing the same after the job completion in proper line and level and compaction etc, complete. Removing exiting dispensing pumps after disconnecting pipeline, electrical connection etc, and stacking carefully as directed. 254 Single Pumps 255 Dual / 2T Mix Pumps
LS
900
NO
1850
NO
350
Job
250
RMT
18
SQM
120
SQM
35
NO NO
460 510
Description
Unit NO
Unit Rate
690
Laying of MS threaded pipeline to the required slope of alignment with providing and fixing necessary MS heavy duty fittings like elbows, tees, including providing and applying doping the pipeline with shalimastic HD 2 coats. 257 40 mm dia pipeline 258 50 mm dia pipeline. 259 80 mm dia piipeline. RMT RMT RMT 330 390 620
Line no.
Unit
Unit Rate
260
Installing Club HP Signage Board with necessary CC 1:2:4 foundation upto required depth. Job also supply 4 nos. of 12mm dia x 750mm long MS foundation bolts etc, complete. Installing Air Tower facility with necessary CC 1:2:4 foundation of required size and also with necessary electrical connection. Positioning of Q & Q Tower Board to shown place with necessary foundation. Fixing of water cooler with necessary electrical connections of 5/15 Amp switch board with necessary wiring. Providing and painting work for Quick Care Point as per standard design. Installing Ingress and Egress Signage Board with necessary CC 1:2:4 foundation and with necessary electrical connection. Installing Credit Card Counter with providing and making electrical connections of 5 Amp Switch socket and telephone socket connection with necessary wiring. PROVIDING AND FIXING 930 PROF GI PERFORATED SHEET
NO
2050
261
NO
1250
262
LS
1700
263
NO
950
264
JOB
800
265
NO
1000
266
NO
1300
267
SMT
650
SUPPLY AND LAYING GRANULAR SUB BASE: Filling material with GSB (Granular Sub Base) of 60 cm thick: The GSB shall consists of the following material 40 to 53MM size metal : 40% 20 to 40MM size metal 20% 10 to 20MM size metal 20% 0 to 10MM size metal 20% Job shall include supply and filling GSB materials in two 268 compacted layers of 300MM each. Payment shall be released on the compacted layer provided by the vendor at site. Compaction shall be carriedout only with Vibro roller of required capacity. Contractor has to obtain necessary clerance from HPCL or its autorised reprensatative for first layer. Only after obtaining the second layer GSB shall be provided. Job includes all material and transporation cost of the required to be completed as per the directions of the HPCL
CUM
700
Line no.
Description Filling in ground, plinth and surrounding areas with good yellow earth (quality shall be approved by engineer) brought from outside in layers of 15 to 20 cms including watering, consolidating the same complete as directed. The filling shall be done strictly in layers and the same shall be compacted and sprinkling of water shall be done simultaneously to get the compacted surface in required gradient. The contractor has to get the soil sample approved from the site engineer, and required testing also shall be done, no extra charges will be given for that. Providing Garden Soil and Farm Yard Manure, mixing same in the proporaiton of 3:1 (by volume) and filling in the Panter wiht this mixture as per plan. Providing and Laying 60mm THK (Compacted Thickness) Premix asphlt carpet on top of WBM or Compacted Surface. Rate to inclde Cleaning the Existing surface with wire brush to remove excess surface materials, rolling the existing surface to receive carpert, providing and spreading tack coat wiht asphalt of 60/70 OR 80/100 OR Equivalent grade dependingon site conditions and approved by EIC @ 9.8 Kg/10Sqm, Premixing the aggregates of specified grading as detailed in the specifications with hot molten asphalt in Mixers, laying on top of WBM surface using mechanical mixers or mixers arrangement approved by EIC depending on Qty to be executed at a perticular site. The rate ATEI Include rolling with 10Mt Roller till Maximum Compaction is Acheived, Testing the surface for camber if Required, Correcting Depressions with additional fresh mix and rerolling as per specifications. providing 20mm Thick seal coat on top of asphalt carpet immediately rolling to full compaction. rate to include premixing the aggregates (6mm cown sized/coarse sand) wiht pre-heated asphalt ( 80Kg/CUM) In mechanical mixera and , Spreading & Rolling to acheive Maximum Compaction as per attached specs. Rate analysis also to include providing of quary dust/sand (As Approved by EIC) After Completion of seal coat. The combined thickness of asphalt carpet & seal coat shall be minimym 80mm. Compact thickness of asphalt carpet shall be minimum 60mm in case seal coat is not layed immediately over the asphalt carpet, Tack coat @ 6Kg/10Sqm of carpet area with asphalt of grade as specified above shall be Spread before laying seat coat. Supply of precast RCC Kerbing blocks of various shapes in PCC 1:2:4 of size 18" Height, 6" Thickness and 12" wide including installing the same in ground. The rate includes excavation up to 6" Deep and 6" wide Compacting the base and 75mm PCC 1:4:8 & Installation by joining Pointing it with cement mix 1:3 If Required back Filling Excavated stuff with wo coats of approved oil dispemper etc complete as per satisf action of EIC.
Unit
Unit Rate
269
CUM
130
270
CUM
240
271
SMT
280
272
RMT
1500
Line no.
Description Providing and planting mexican lawn type - Ready made grass in area alongwith top soil filling of 150mm with manure good earth etc or as per direction of EIC. Supplying and fixing mehendi red 150mm height plant in area as per layout and instruction of EIC. Including watering etc complete till the plant has survived.
Unit
Unit Rate
500
273
SMT
274
NO
20
Line no.
Description Supplying and fixing mehendi golden 100mm height plant in area as per layout and instruction of EIC. Including watering etc complete till the plant has survived. Supplying and fixing mehendi bitter (Green Hedge Type) type of 150mm Plant in area as per layout and instruction of EIC. Including watering etc complete till the plant has survived. Providing and fixing prefabricated 500mm High crash barrior in tubes 2mm THK outside pump island, at both side ends of island with grouting in CC 1:2:4 size and 450X450X300mm & including transportation etc complete. ( The details to be sought as per new format island). Note party to quote rate for only one side of Island.
Unit
Unit Rate
20
275
NO
276
NO
15
277
NO
9000
Line no.
Description
Unit
Unit Rate
Line no.
Description
Unit
Unit Rate
284
SMT
950
286
SMT
85
287
SMT
920
288
SMT
480
Line no.
Description BRICK MASONARY - 230 MM THICK IN 1:4 CM FOR KERBING : Providing and constructing brick masonry in CM 1:4 using bricks having minimum compressive strength 35 Kg/cm2 and conforming to IS: 1077- Latest Edition including providing all openings and projections. 18-20MM THICK GRANITE SLAB : Providing and fixing machine cut and polished spotted grey or black Granite slab of thickness of 18-20 mm selected & sorted for uniformity in colour. EARTH FILLING YELLOW : Supplying and filling good quality yellow earth in layers of 150 mm thick including watering and compacting till maximum compaction is achieved as directed by Engineer In Charge. Supply and fixing as per manufacturer's specification vitrified ocean mist tiles of 1m X 1m of NITCO make. Supply and painting yellow thermoplastic road marking paints of approved make at asphalted / pavered and RCC Driveways with HPCL approved symbols signages and letterings. Supply & Fixing rolling shutter in enamel paint,1.2mm THK MS Sheet slats as per approved DRG enclosed. Supply, fabrication and fixing staircase railing with polished stainless steel pipe at two levels of 40mm & 30mm with SS plate balusters with 4 row of 12mm DIA steel tubes (details as per drawings) of any SS structure as per drawing supplied by HPCL like island guard etc. Stainless Steel should be of best grade i.e 304 grade. Supply and fixing deep blue powder coated, extruded aluminium section frames with clear glass / prelaminated particle board infill paneles, glass should be of modi / saint gobain and all sections to be of jindal make. ( Refer DRG Enclosed for more details). Providing and fixing Al fixed glazing as per format drawing enclosed. Glazing frame should be poweder coated with HP blue. SUPPLY AND FIXING DOOR SPRING OF EVERITE / HARDWYN. SUPPLY AND FIXING OF DOOR CLOSER OF HARDWYN / EVERITE MAKE.
Unit
Unit Rate
290
CUM
1850
291
SMT
4000
292
CUM
150
293
SMT
2050
294
SMT
950
295
SMT
2000
296
KG
560
297
SMT
3500
298
SMT
3900
299 300
NO NO
1500 1200
Line no.
Description Providing & Fixing under ground / open 100 mm dia PVC pipe for Rain water line, conduit, cabling, draingange etc. as per details including necessary specials, fixing the clamps & applying approved paint. The pipes shall be of Prince / kissan or equivalent ISI make including fixing the jonts with pidilite/ Aralidate type sealent complete. Providing & fixing under ground / open PVC pipe 75mm dia. PVC pipe for Rain water line, conduit, cabling, drainage etc. as per details including necessary specials, fixing the clamps & applying approved paint. The pipes shall be of Prince / Kishan or equivalent ISI make including fixing the joints with pidilite/ Araldite type sealant complete. Providing and fixing 40 mm dia PVC pipe of 6 kg/sq cm of PRINCE / SUPREME or approved make for rain water / sewage with all necessary fitting like bend, coupling, tee etc. Provding and fixing cast iron floor trap Heavy Duty of self cleansing design conforming to IS specs with 100mm inlet, 75mm outlet and 150mm CP hinged grating of 6mm thick with rim. Rate shall include making all necessary leak proof connections etc. Supplying and laying the following cast iron socket and spigot end pipes including plain or plug type bends, shoes, offsets, clamps junctions, tees, etc caulking of joints with lead, smoke testing the pipeline before commissioning and applying 3 coats of black enamel paint over a coat of primer after necessary surface preparation complete. 100 mm dia soil down take pipes upto gully trap with 45 mm deep joint as per IS 1729 - 1979.
Unit
Unit Rate
301
RMT
200
302
RMT
170
303
RMT
120
304
NO
100
305
RMT
150
306
Supplying and laying the following cast iron socket and spigot end pipes including plain or plug type bends, shoes, offsets, clamps junctions, tees, etc, caulking of joints with lead, smoke testing the pipeline before commissioning and applying 3 coats of black enamel paint over a coat of primer after necessary surface preparation complete. 150 mm dia soil down take pipes upto gully trap with 45 mm deep joint as per IS 1729 - 1979. Supplying and fixing in position 225mm x 150mm (9 x6) S.W. Gully Trap, make of jaguar-Continental in brick masonary chamber of required size with C.I. Covers and frames of approved quality (Heavy Duty 100 kg.) including excavations and back filling, cement concrete 1:3:6 in foundation and bed in brick masonry in CM 1:2,Plastering 20mm with CM 1:1 finished with a neat coat of cement etc. complete as per HPCL specifications and Architects instructions.
RMT
210
307
NO
500
Line no.
308
309
Description Providing and constructing inspection chamber as given below & as per the enclosed sketch. 900 x 900 mm (Internal dimensions) with 750 mm depth for main chamber with top RCC slab in 1:1.5:3 mix, excavation, BBCC/PCC wherever required & floor concrete 1:3:6 mix. complete as per drawing .The inside walls should be duly plastered with 15mm cement slurry & channels made in cement concrete in 1:2:4 mix, with CI frame & cover weighing 125 kg confirming to IS 1726-1974 pattern-2 (Part VI/Sec I), curing testing, complete. Providing and constructing inspection chamber as given below & as per the enclosed sketch. 600mm x 600 mm (clear Internal dimensions) with 600 mm depth with brick masonry 230mm thick wall inside & top finish plaster with necessary excavation, B.B.C.C. etc. complete for outlets of all water closets and at all bends in the sewerage pipes with CI frame & cover weighing 125 kg confirming to IS 1726-1974 pattern-2 (Part VI/Sec I). Supply and fixing WC Orrisa pan with low level cistern. WC0109/17, CISTERN-0709 PARRYWARE, 20028 HINDWARE.
Unit
Unit Rate
NO
5000
NO
3500
310
NO
6000
313
RMT
225
Line no.
Description Supplying and laying underground 25mm dia G.I. "B" Class pipe lines of TATA / Zenith / Jindal or equivalent approved ISI make only for water connections including supplying and fixing of all special fittings and fixtures like elbows, bends, tees, reducers, coupling and threading including excavation upto 600 deep, back filling of trenches and making good the damaged surface for underground pipes and fixing pipeline with suitable G.I. clamps, making water tight threading joints back filling of trenches, consolidating, watering etc. including painting above ground P/L with 3 coats of aluminium / synthetic enamel paint as per HPC specifications and Architects instructions. Supplying and laying underground 50mm dia G.I. "B" Class pipe lines of TATA / Zenith / Jindal or equivalent approved ISI make only for water connections including supplying and fixing of all special fittings and fixtures like elbows, bends, tees, reducers, coupling and threading including excavation upto 600 deep, back filling of trenches and making good the damaged surface for underground pipes and fixing pipeline with suitable G.I. clamps, making water tight threading joints back filling of trenches, consolidating, watering etc. including painting above ground P/L with 3 coats of aluminium / synthetic enamel paint as per HPC specifications and Architects instructions. Supply & fixing fullway valve of 15mm dia for GI pipeline of GG / LEADER make. Supply & fixing fullway valve of 25mm dia for GI pipeline of GG / LEADER make. Supply & fixing fullway valve of 50mm dia for GI pipeline of GG / LEADER make. Providing and fixing bevelled edge mirror of superior glass of 5/6 mm thick of MODI GUARD GLASS make, 3mm thick felt backing over 8mm water proof ply KITPLY/ANCHOR or equivalent make and with wooden beading allround of 600 X 600 size and fixed with wooden plugs with CP brass screws and cup washers etc. all complete as directed by Engineer In Charge.
Unit
Unit Rate
314
RMT
270
315
RMT
470
316
NO
800
317
NO
1400
318
NO
3000
319
SFT
250
Description Supply & Fixing towel rings - CP ring mounted on wall of 1576 Classic Line- Parko. Supplying and filling good quality Yellow/ Red Murrum in layers including watering and compacting till maximum compaction is achieved as directed by engineer in charge. The specification meeting to the latest standards of IS code. Providing and constructing brick masonry in CM 1:4 using bricks having compressive strength 35 Kg/cm2 and conforming to IS: 1077- Latest Edition including providing all openings and projections as per the drawing, raking the joints to 1 cm deep, scaffolding, soaking of bricks prior to use and curing etc complete as per specifications. 230 mm & above thickness in walls / foundations etc. Providing and laying average 20 mm thick sand faced cement plaster as per following procedure : Apply 12 mm thick coat of CM 1:4 mixed with CICO/ IMPERMO/ ACCOPROOF water proofing compound mixed as per manufacturer's specifications as 1st coat and leaving the surface rough. Apply 2nd coat of 8 mm thick of CM 1:4 and finishing the surface by rubbing with sponge till uniform texture is obtained. Rate shall include providing necessary scaffolding, chicken wire mesh at all joints of brick and concrete surfaces, with a minimum overlap of 150 mm in all directions and curing complete. Providing and laying following thick cement plastering in single coat to all the interior walls / ceiling including scaffolding, chicken wire mesh at all joints of brick and concrete required to achieve perfect line and level. 12mm thick plastering in CM 1:4 for walls with NEERU/LIME finish. Supplying fixing AC corrugated sheet of "Charminar or Everest"or approved make for roofing including supply of 'J' bolts and 75 mm MS Pipe with red oxide paint and bitumen and GI washers etc. complete. Providing and fixing AL coloured sheet for roofing of Track Make of 1-1.5mm thickness. Supply and fixing structural steel work with Pipe railing and Baluster as per DRG enclosed. Supplyand fixing conventional mangalore tiles for sloping and Chajja. Supply and fixing tube light mirror optic of 2 X 36w of PHLIPSTBS300 / 418 M1, WIPRO- CAT NO. WCF93418NS or cromptonCAT NO. CRFN 42 HSB. Supply and fixing with complete fixtures 1X36W Box Type fitting Luminaries of WIPRO CAT NO.14140, PHILIPS-CAT NO. TMC 501/136 or CAT NO. DJB 14 of Crompton.
Unit NO
321
CUM
200
322
CUM
1750
323
SMT
145
324
SMT
130
325
SMT
250
326
SMT
1250
KG SMT NO
51 700 1900
330
NO
500
Description providing and fixing 1 x13W CFL down light with complete fixtures of WIPRO / PHILIPS or CROMPTON make
Unit NO
Line no.
Description Providing of cable trench by excavation in any type of soil including WBM/ Asphalt upto 450mm depth and 300mm wide including supply and laying of 150mm thick sand top and bottom of cable, supply and laying bricks laid flat on top, backfilling trench etc. complete. Providing and laying PVC armored cable of CI, ASIAN, Trapdoor (Seimens) or equivalent make confirming to IS: 1554 (part-1) 1976 for power/light wiring and providing necessary connections as directed A) 4x4 core Copper cable. Providing and laying RCC 1:1.5:3 concrete for works using 20 mm and down size graded crushed aggregate including providing and fixing necessary shuttering, scaffolding, machine mixing, compacting by mechanical vibrators, curing etc complete. Concrete shall conform to IS 456-Latest edition. Rate shall be exclusive of the cost of steel reinforcement, which will be paid under a separate item. Supply/ Fabricating & Construction of Electrode Type Earting Pit as per IS 3043 and Electrode with Typical Earthing chamber including PCC Chamber, cast Iron cover, and 600X600 CU Plate & 40mm GI Pipe with funnel / mesh and two runs of 40X6mm CU Strip as per drawing enclosed in " Appendix-5 complete. The cost includes excavation / charcoal / sand etc complete. The clamping arrangenent shall be done by proper NUT BOLTS / WASHERS etc complete. Note all scope as shown in the appendix-5 (Enclosed) Should be kept in mind the earthing chambers, covers etc all should be included in the rates. Please ref\er drawing No. Appendix-5 Enclosed. Providing and fixing 75mm dia `B' CLASS GI pipes with plugs, nipples, unions, etc including all acessories. The pipes should be buried underground in trenches etc complete Providing and fixing 60mm dia `B' CLASS GI pipes with plugs, nipples, unions etc including all acessories. The pipes should be buried underground in trenches etc complete Providing and fixing 100mm dia `B' CLASS GI pipes with plugs, nipples, unions, etc including all acessories. The pipes should be buried underground in trenches etc complete Providing and laying RCC 1:2:4 concrete for works using 20 mm and down size graded crushed aggregate including providing and fixing necessary shuttering, scaffolding, machine mixing, compacting by mechanical vibrators, curing, etc. complete. Concrete shall conform to IS 456-Latest edition. Rate shall be exclusive of the cost of steel reinforcement, which will be paid under a separate item.
Unit
Unit Rate
332
RMT
700
333
RMT
140
334
CUM
3800
335
NO
9000
336
RMT
680
337
RMT
560
338
RMT
780
339
CUM
2960
Line no.
Description Supplying and fixing in position 7M meter height Bajaj Make Octagonal Yard light poles of single arm including 3 wires x 2.5 sq.mm copper wire from fuse cut out to luminaire and 8 SWG coil earthing with salt & coal for each pole. The rate shall include light fixture suitable for 250 Watt metal halide light lamp of "phillips/ crompton / wipro" make includding supplying of condenser, ballast, igniter and cost of lamp also. ( Excluding Foundation) Supplying and fixing in position 7M meter height Bajaj Make Octagonal Yard light poles of double arm including 3 wires x 2.5 sq.mm copper wire from fuse cut out to luminaire and 8 SWG coil earthing with salt & coal for each pole. The rate shall include light fixture suitable for 250 Watt metal halide light lamp of "phillips/ crompton/wipro" make includding supplying of condenser, ballast, igniter and cost of lamp also. Supplying & erection of fire buckets with covers filled with good quality sand with stands of angle frames of the same at appropriate place. Rate to include painting with 2 coats of red oxide primer and 2 coats of enamel paint of approved make and shade. The stand should be 1.5 mtrs. height fabricated with 50x50x6 angles with required shading arrangements on top of buckets with 18 guage MS sheet on 25x25x4 MS angles (each stand to have four buckets). Supply & Fixing / Grouting of MS foundation J bolts for foundation in RCC. Job includes supply of J bolts & check nuts. Exhuming 22 kl tank from earth / masonry pit. The job includes taking out the balance product from tank, opening nut bolts from raft, excavation / clearing the sand/soil & lifting under ground tank from RCC / Earth pit by crane only and loading the same at cariier / truck or storing safely at places as drected by EIC. All tool tackles, machinary crane labour etc will be borne by the party Exhuming 16/14 kl tank from earth / masonry pit. The job includes taking out the balance product from tank, opening nut bolts from raft, excavation /clearing the sand/soil & lifting under ground tank from RCC / Earth pit by crane only and loading the same at carrier / truck or storing safely at places as drected by EIC. All tool tackles, machinary crane labour etc will be borne by the party Supply of DCP (B&C) type 10 kgs. Fire extinguishers as per ISI specifications and ISO 9002 certified company of approved make like Minimax, Firex, Bharat, Safex with complete accessories. Supply of CO2 type 4.5 kgs. Fire extinguishers as per ISI & CCE approved and specifications and ISO 9002 certified company of approved make like Minimax, Firex, Bharat, Safex with complete accessories.
Unit
Unit Rate
340
NO
18500
341
NO
24000
342
NO
5500
343
KG
55
344
NO
10000
345
NO
9500
346
NO
1850
347
NO
4500
Line no.
Description Providing, spreading and rolling 10mm black grit ( black basaltic rock) on the drive way with consolidate thickness of 25mm. Supply and Fixing 1" X 5mm thick copper braided strip of IS quality / make and clamping the same with earthing grid and earthing clip of as advised by EIC complete Supply and Fixing ISI Mark crocodile CLIP Including Fixing / Connecting the same with braided STRIP/WIRE. The crocodile clip should have CU / BRASS connecting point and should be of ISI mark. Supply and fixing fill cap of cast iron having clamp /stud for earthing arrangement with BIS threading suitable male - female coupling with unloading hose. The fill cap shall have cast iron cap with locking arrangement and earthing clamp/stud to facilitate fixing of CU braided strip. Supply and installation of 1HP Kirloskar make submersible water motor pumpset including fitting of switch/STARTER/CABLE/panel at electrical room within 25 RMT distance. Installation of air tower in RCC foundation OF 1:2:4 (0.5 m wide and 1 m long) of 100m height from FGL and 150mm below FGL with excavation supply & grouting of necessary nut foundation / bolting ( included in rate) of base frame etc complete in all respects. The job includes base plaster 12mm thk of CEMENT RATIO 1:4 & fixing granite tiles of 10mm thick as per standard procedure. Supply, transportaion & laying of prefabricated FIBRE REINFORCEMENT CONCRETE trench cover of size 600mm x 450mm and 100 thickness of M30 grade including transporation, laying etc complete. The rate includes supply and fixing of 18 guage MS sheet on periphery of trench cover etc complete including providing of hooks made with 12mm thick reinforcement steel bar by moulding the bar. Installation of Master pole with Logo Box. The scope includes installing the same by crane, supply and fixing 6"x6" single choke Sintex make Junction box, supply of 2.5 sqmm. 3 core cable of polycab / mecab / Finolex / Avocab / Procab / Powercab make from JB to logo box including testing electrical system and commissioning the same etc complete. Installation of Grand ID Signage post. The scope includes installing the same at existing foundation by crane including end termination of cables from the point, testing the lights / electrical connection and commissioning the same etc complete.
Unit
Unit Rate 35
348
SMT
349
RMT
235
350
NO
100
351
NO
700
352
NO
9500
353
NO
2500
354
NO
700
355
NO
3200
356
NO
8500
Line no.
Description Installing Curtain wall Logo Box with Logo. The scope includes fixing the same in the curtain wall gap / depression, sealing the gap by cement slurry and matching it with granite, carrying out electrical connection of cable from nearest point and testing the same and commissioning etc complete. Installing Q&Q tower at site. The job includes installing the same at existing foundation with providing 4 nos of anchor fastners with bolts etc complete the fastner and bolts should be included in rates. Supply & Fixing 6 Amp or 16 Amp DP MCB of indokopp Gold / Legrend Make at existing panel or wall or as directed by EIC. Supply and fixing SINTEX make single choke outdoor junction box. Including fixing the same at post or places as directed by EIC. Supply and fixing SINTEX make Double choke outdoor junction box. Including fixing the same at post or places as directed by EIC. Supply and fixing cable jointing kit of Araldite make to cables of 4 CORE 2.5 SQMM cable at places as directed by EIC.
Unit
Unit Rate
357
NO
600
358
NO
750
NO NO NO NO
Description Transportation of Dispensing Unit / Master pole/ Curtain Wall Logo / Air Tower / Q&Q Tower / Club HP Pole / Yard Lght Pole / Air Compressor / City Pylon from storage point to various Retail Outlets including loading and unloading at both ends.
Unit NO
Unit Rate
2200
364
TPT OF D/Us 101 TO 200 KMS Transportation of Dispensing Unit / Master pole / Curtain Wall Logo / Air Tower / Q&Q Tower / Club HP Pole / Yard Lght Pole / Air Compressor / City Pylon from storage point to various Retail Outlets including loading and unloading at both ends.
NO 3800
365
TPT OF D/Us 201 TO 300 KMS Transportation of Dispensing Unit / Master pole / Curtain Wall Logo / Air Tower / Q&Q Tower / Club HP Pole / Yard Lght Pole / Air Compressor / City Pylon from storage point to various Retail Outlets including loading and unloading at both ends.
NO 4500
366
TPT OF EXISTING MS HOARDING 0 TO 10 TON WEIGHT UPTO 100 KM. TPT of existing MS Hoarding board including loading & Unloading at both ends carefully.
MT 1700 MT 2200
367
TPT OF EXISTING MS HOARDING 0 TO 10 TON WEIGHT 101 TO 250 KM. TPT of existing MS Hoarding board including loading & Unloading at both ends carefully.
368
REMOVAL OF EXISTING MS HOARDING UPTO 5 TON. WEIGHT Removing of existing Hoarding Board with removing of electrical connection & fixtures. Job also including of put the material at safe place.
MT 2800
369
REM OF EXISTING MS HOARDING 5 TO 10 TON. WEIGHT Removing Of Existing Hoarding Board with Removing of Electrical Connection & Fixtures. Job also including of put the material at safe place.
370
ERECTION OF HOARDING BOARD UPTO 5 TON WEIGHT Erection of supplied Hoarding Board with necessary bolting and minor reparing work completed.
371
ERECTION OF HOARDING BOARD 5 TO 10 TON WEIGHT Erection of supplied Hoarding Board with necessary bolting and minor reparing work completed.
372
HOARDING PAINTING - ARTISTIC Painting of MS Hoarding : Painting of MS Hoarding as per message (ART WORK) given by HPCL at various Outlets under Region. Job Includes surface preparation, applying two coats of synthetic enemel paint of approve make. Job also inludes providing scaffoldings / tool tackles etc complete.
120
Description
Unit SQM
Unit Rate
Supplying and Fixing of 22 gauge GI Sheet on Hoardings Board structure by Alluminium Reverting arrangement of size 20mm long and 6mm dia as shown In the Drg. Job also includes painting of GI sheet with 2 coats of Red Oxide. Job includes scaffoldings / tools / tackels etc complete. 374 S&L. OF PRECAST FRC TRENCH COVER W/O MS SHEET Supply & Laying of precast 150mm thk. RCC trench cover in M30 Cement Concrete grade with 12mm dia TMT reinforcement steel bar in 100mm c/c both way job also including of laying of cover on pipeline trench in line and level completed. 375 S&F 150 WATT METAL HALIDE S&F 150 watts MH Light fixtures on the Hoarding of WIPRO/BAJAJ/PHILIPS make suitable for outdoor use with prior approval of HPCL and complete in all respects. Job insludes clamping arrangement for light to focus on the Hoarding. 376 S&F NFLP JUNCTION BOX Supplying and fixing NFLP Junction box of size 6"X4" Sintex Box NFLP glands for lighting. 377 S&F 16 AMP DP MCB SWITCH Supply and fixing of 16 Amp MCB DP Switch of " INDOKUPP" LEGARND, HAGER -L&T Brands ISI make in distrubition board or if required PVC cover completed with switch. 378 P&L OF 1.5 SQMM 3 CORE FLEXIBLE CABLE P&L of 1.5 SQ.MM 3 Core flexible cable in 1.5sqmm dia screened and shielded wire in 20mm dia PVC conduit partly / fully concealed in types of walls, floor etc. complete with all accessories, wiring terminations, connected Civil works , rough plastering etc. 379 P&L OF 2 PAIR TELEPHONE WIRE Providing and Laying 2 Pair of 0.5mm Dia screened and shielded Telephone wire in 20mm dia PVC conduit partly / fully concealed in all types of walls, floor etc complete with all accessories, wiring terminations, connected Civil works , rough plastering etc including tools tackles clamps pins etc complete. 380 P&F OF 63 AMP CHANGE OVER SWITCH Supply and installation of 63 AMP Change Over Switch in sheet steel enclosure suitable for wall mounting with necessary accessories and fixing items. " KEW & L&T" brand ISI make. 381 P&F OF CASSING CAPPING PATTI P& F of cassing capping patti of required size for open wiring in side sales building with line and level completed. 382 P&F OF ELECTRONICS TYPE ELECTRICAL TUBE LIGHT/ CHOKE NO RMT NO RMT RMT NO NO NO CUM
500
4500
5300
400
575
55
18
4500
32
Line no.
Description Providing & Fixing of Tube Light with electronick Chock of 'Philips' & 'Crompton' make in Grand ID Tower and curtain wall logo box.
Unit
Description
Unit NO
Unit Rate
Providing & Fixing of 40 Amp ELCB 4 pole switch of " INDOKUPP / LEGARND / HAGER / L&T Brand ISI Make 384 P&L OF 25MM DIA FLEXIBLE PVC CONDUIT PIPE P&L of 25mm dia flexible PVC conduit pipe for conducting of wire for distribution board MCB switch cable laying. 385 P&L OF TWO WAY POINT WIRING Providing and Laying of Point Wiring in concealed conduits for the following points using specified grade PVC insulated, ERLS multistranded 3X1.5 Sqmm copper wire. Job also including of preparation of wall in plastering work completed. 386 PAINTING OF AIR TOWER & Q&Q TOWER P&A of 2 coats of synthetic enamel paint 1st quality of approved manufacturer and shades on steel srface to give an even shade including two coats of red oxide primer after thoroughly brush. 387 EXHUMING OF 9/11 KL TANK Degassing exhuming tank from the Pit including excavation etc. Job covers dismantling all fittings and piping etc. Job also includes removal of products & store in safe place as advised by HPCL's representative (9/11KL tank) 388 BM EARTHING CHAMBER Providing and constructing earthing inspection chamber of 450X450mm (internal dimensions) with 4450 mm chamber and medium duty rectangular type CI frame & cover confirming to IS 1726-1974 pattern (Part VI/Sec l). The rate includes excavation, PCC 1:3:6, brcik masonry, cover CI plate (man hole cover) of 12mm thick etc complete including earth resistant / testing plate complete. 389 INST.OF YARD LIGHT POLE Inst. of existing Yard light Pole with arm & light fixtures. Job also including of electrical flexible cable and necessary electrical connection completed. 390 INST. OF AIR COMPRESSOR Inst. of supplied Air Compressor in cement concrete base in CC 1:1.5:3 M-20 grade with foundation bolt completed. 391 S&I OF AIR COMPRESSOR SHAED Suppling & Installation of prefabricated MS squre pipe structural shade with Finolex make 1.3 mm thk. PVC roofing sheet with necessory bolting completed. Jjob also including of excavation, errection in CC M-15 grade grouting, aplying of two coat of red oxide and two coats of enamel paint etc complete. 392 S&F Of FRP SHEET SHED Suppling & Fixing of FRP roofing sheet shade in hollow pipe section frame structure approved colour with necessory bolting completed job also including of excavation, errection in CC M-15 grade grouting, aplying of two coats of red oxcide and 2 coats of synthetic enamel paints etc complete.
SIGN AND SEAL OF BIDDER
3700 RMT 15
NO
1200
NO 850
NO 10500
NO
1850
NO 2500 NO 2500 NO
12500
SQM 2000
Description Supplying & Fixing of 300mm dia Air Gauge approved quality of Air Master make or equalent brand with nesscery fitting & connecation complete.
Unit NO
394
P&L OF 12MM DIA BRADED WIRE FLEXIBLE AIR PIPE P&L of 12mm dia braided wire flexible air pipe for Air Filling connecting Air Gauge.
RMT 80 NO 1250
395
REMOVING OF DEAD STOCK / WATER FROM U/G PRODUCT TANK UPTO 50 KM. Removing of dead stock / water from U/G product tank by hand pump manually upto 50 km.
396
REMOVING OF DEAD STOCK / WATER FROM U/G PRODUCT TANK 51 TO 200 KM. Removing of dead stock / water from U/G product tank by hand pump manualy 51 to 200 km.
NO 1600
397
REMOVING OF 80MM DIA FILL CAP/ 40MM DIA NRV & DIP CAP UP TO 50 KM. Removing of existing 80mm dia Fill Cap / 40mm dia NRV and Dip Cap - in City area
NO 150 NO 350
398
REMOVING OF 80MM DIA FILL CAP/ 40MM DIA NRV &DIP CAP 50 TO 200 KM. Removing of existing 80mm Dia Fill Cap / 40mm dia NRV and Dip Cap - in 51 to 200 km.
399
REMOVING OF FACIA BAND Rem. of existing red & blue facia band from canopy or sales bldg carefully with disconnect elec. supply completed.
RMT 90 NO 350
400
REMOVING OF Q&Q TOWER Removing of Q&Q Tower or Air Tower with dismantling of CC base and debris removing to unobjected place with removing with disconnect Electrical power supply.
401
REMOVING OF CURTAIN WAL LOGO Removing of Curtain Wall Logo and put it at safe place with disconnect Electrical power supply.
NO 250
402
REM OF MASTER POLES Removing of Master Pole / Club HP Pole and put it at safe place with disconnect Electrical power supply.
NO 2500
403
REMOVING. OF 40/50MM DIA PIPE LINE Removing of 40 / 50mm dia existing concealed Pipe Line with excavation, back filling and preparation of drive-way completed.
RMT 50
404
REMOVING. OF 80MM DIA PIPE LINE Removing of 80mm dia existing concealed Pipe Line with excavation, back filling and preparation of drive-way completed.
RMT 75 SQM 85
405
Line no.
Description Dism. of Ceramic / Glaze tiles with backing Plaster from existing wall and floor. Job also including of removing of debris to out side of unobjected place.
Unit
Unit Rate 85
Description DISM.OF EXISTING ASHALT D/W Dismantling of exiting 80mm thk. Asphalting D/W with 2 layer of 75mm thk. WBM and 230mm thk rubber soling job including of removing of debris to unobjected place.
Unit SQM
Unit Rate
120
407
APPLYING OF RED OXIDE P&A of 2 coats of Red Oxide 1st quality of approved manufacturer on steel surface by thoroughly brush.
SQ.MT 32
408
P&A OF ENAMEL PAINT ON CURBING WALL Providing & Applying of One coat of Primer & Two coats of synthetic paint yellow & black paints as per chequred pattern 300mm to 300mm size.
RMT. 150
409
P&L OF PRECAST RCC CURBING Providing & Laying of precast RCC curbing block in CC 1:1.5:3 concrete M20 grade of 300mm x 450mm x 150mm thk. size with excavation, 75mm thk. PCC & pointing on joint completed.
RMT. 750
410
DISMANTILING OF BM WALL Dismantiling of existing BM wall job also including of debris to unobjected place completed.
CUM 55
411
DISMANTLING OF PCC Dismantling of existing PCC on D/W or foundation job also including of debris to unobjected place completed.
CUM 550
412
DISMANTLING OF RCC Dismantiling of existing RCC column base/ column / beam and slab job also including of debris to unobjected place completed.
413
150MM GI PIPE P&F of 150mm 'B' class GI pipes with plugs, nipplex, unions, etc including all acessories. The pipes should be buried underground in trenches etc complete.
414
200MM GI PIPE P&F of 200mm dia 'B' class GI pipes with plugs, nipplex, unions, etc including all acessories. The pipes should be buried underground in trenches etc complete.
RMT. 2250
415
GROOVE CUTTING Groove cutting 15mm wide & 25mm deep in trimix floor after 10 days curing of the side floor by working groove cutter & the sand mix in thereafter filling the with 40 grade grout proporation 1:1
RMT. 85
416
STONE WARE SOIL PIPE [100MM DIA] P&L of 100mm dia salt glazed stoneware pipes completed.
417
EXPANSION JOINT
Line no.
Description P&L of expansion joint in RCC D/W slab in salitex board with bituminious primer 20mm thk. 200mm depth job also including of 35mmx35mmx5mm thk. Angle on top age both side as per detailes drawing.
Unit
Description INSP. CHAMBER WITH CI COVER 600X600X700 P&C of following size inspection chambers with 230mm thick brick masonry in 1:5 cement mortar, excavation, 75mm thick PCC 1:4:8 bed, plastering with neat cement finish, providing 35 kg. CI cover with frame completed.
Unit NO
Unit Rate
3800
419
420
S&F OF CHEQUERED PLATE Supplying, fabricating & fixing at all levels chequred plate including two coats approved synthetic enamal paint over a primer coat on the exposed surface wereever necessory and grouting of pocket where ever required completed. S&F OF GI SHEET S&F of 18 guage GI sheet board with ISBM Channel by aluminium rivetting arangement of size 20mm long and 6mm dia as shown in the drg. Job also includes painting of GI sheet with 2 coats of red oxide including scafolding tools/tackles etc complete.
KG 72
SQM 525
421
Supply and filling Silica Gel Anhydrous Crystals as per standards of HPCL. S&F Silica Gel double flanged trap made up of MS or as per HPCL Standards to be fitted in 40mm DIA MS Vent Pipeline. The Silica GEL Trap should be of 12-12.5mm MS flanged plate thickness. The cost includes supply and fixing of the same in Petrol / Power Vent Pipeline, inlcuding cost of Labor, tools tackles etc complete.
KG NO
700
422