Tekelec is a leading developer of telecommunications signaling infrastructure, soft switches, diagnostic solutions, and service applications. The companys highly reliable solutions enable telecommunications carriers and equipment suppliers to provision and test a variety of revenue-generating services featuring voice and data technologies. Tekelecs innovative solutions are widely deployed in traditional and next-generation wireline, wireless, and IP voice/data communications networks around the world Founded in 1979, Tekelecs corporate headquarters are located in Calabasas, California, with operations in Morrisville, North Carolina; Richardson, Texas; Staines, United Kingdom; and Tokyo, Japan.
TABLE OF CONTENTS
Format of SS7 SU Types ..........................................2 SS7 LSSU Format......................................................2 SIO Field....................................................................3 Routing Label ............................................................3 Format of SPC (ANSI) ..............................................3 Format of ISPC (ITU)................................................4 MTP Management Messages Structure ....................4 SNM Heading Code Table ........................................4 SNT Heading Code Table ..........................................5 MSU Signalling Message Structure ..........................5 SS7 Function Levels ..................................................5 SNM/SNT Heading Code Table Abbreviations ........6 General ISUP Message Format: Mandatory Parameter Section ..............................7 General ISUP Message Format: Pointer Section ....................................................8 General ISUP Message Format: Optional Portion ..................................................8 SCCP Messages and Protocol Classes Table ............9 SCCP Messages Parameters Table ............................9 SCCP Parameter Name Codes Table ......................10 General ISUP CIC Field ..........................................10 ISUP Mandatory/Optional Parameters Table (ANSI) ................................................................11 ISUP Mandatory/Optional Parameters Table (ITU White Book) ..............................................13 ISUP Message Type Table ......................................15 ISUP Parameter Code Table ....................................16 TUP Heading Code Table ........................................18 TUP Heading Code Table Abbreviations ................19 Glossary of SS7 Acronyms......................................20 SS7 References ........................................................21
-1-
FISU(LI=0)
F LI I FSN B
6 1 7
B I B
1
BSN
Opening Flag
* 8
Level 2
Level 3
Level 2
SF
Flag
8
F LI I FSN B
2 6 1 7
B I B
1
BSN
Opening Flag
8
16
8 or 16
Level 2
Level 3 Above
Level 2
MSU(LI>2)
SIO
F LI I FSN B
2 6 1 7
B I B
1
BSN
Opening Flag
8
SF
F LI I FSN B
B I B
BSN
Opening Flag
Spare
Status Indications
CBA
0 0 0 0 1 1 0 0 1 1 0 0 0 1 0 1 0 1
Status Indication
"O"ut of alignment "N"ormal alignment "E"mergency alignment "O"ut of "S"ervice "P"rocessor "O"utage "B"usy
-2-
SIO Field
Level 2 Level 3 Above Closing FCS/CK SIF Flag F SIO LI I FSN B B I B BSN Opening Flag * Level 2
Sub-Service Field
Service Indicator *
DCBA 0000 0001 0010 0011 0100 0101 0110 0111 Others SNM SNT (*1) SNT (*2) SCCP TUP ISUP DUP (*3) DUP (*4) Spare
XX *1 *2 *3 *4
ANSI Priority Regular MSGS Special MSGS Call and Circuit related Facility registration and cancellation
Routing Label
Level 2 Level 3 Above Closing FCS/CK SIF Flag F SIO LI I FSN B B I B BSN Opening Flag * Level 2
ITU: 12 14 14 Bits
*First Bit Transmitted
-3-
L KJIHGFED C
Area/Network Identification 8 SANC ISPC
Zone Identification 3
F SIO LI I FSN B
B I B
BSN
Opening Flag
MTP Level 3
Routing Label
Information Content
H1 MSG Type
H0 MSG Group
0000 CHM 0001 ECM 0010 FCM 0011 TFM 0100 RSM 0101 MIM 0110 TRM 0111 DLM 1000 SPARE 1001 UFC 1010 1011 1100 1101 1110 1111
LLI = LLT in ITU LRI = LRT in ITU *ANSI only
COO COA ECO ECA RCT TFC TFP TCP* TFR RSP RSR RCP LIN LUN LIA TRA TRW* DLC CSS ENS UPU
CBD CBA
LRI
-4-
F SIO LI I FSN B
B I B
BSN
Opening Flag
Signalling Information
Routing Label
TUP
H1
HO
SLS
CIC Code Message Type
ISUP
TCAP
Transaction Portion
OMAP
7 ASES TC 4-6
ISUP Level 4
TUP Level 4
MTP (Levels 1 - 3)
1-3 NSP
Signalling Network Functions Level 3 Signalling Link Functions Level 2 Signalling Data Link Functions Level 1
-5-
Signaling Information
Routing Label
Message Type Code CIC** Mandatory Fixed Part Pointers for the Mandatory Variable Part Pointer for the Start of Optional Part Mandatory Variable Part Optional Part
*First Bit Transmitted
-7-
Signalling Information
Routing Label
Message Type Code CIC** Mandatory Fixed Part Pointers for the Mandatory Variable Part Pointer for the Start of Optional Part Mandatory Variable Part Optional Part
Length of Parameter 1 Parameter 1 Content Length of Parameter 2 Parameter 2 Content ------------------------------Length of Parameter m
Parameter m Content
Signalling Information
Routing Label
Message Type Code CIC** Mandatory Fixed Part Pointers for the Mandatory Variable Part Pointer for the Start of Optional Part Mandatory Variable Part Optional Part
**For ISUP only. *First Bit Transmitted
Optional Parameter 2 Length of Parameter 2 Parameter 2 Content --------------------------Optional Parameter m Length of Parameter m Parameter m Content End of Optional Parameters
-8-
Message Type CR CC CREF RLSD RLC DT1 DT2 AK UDT UDTS ED EA RSR RSC ERR IT XUDT XUDTS Connection Request Connection Confirm Connection Refused Released Release Complete Data form 1 Data form 2 Data Acknowledgment Unitdata Unitdata Service Expedited Data Expedited Data Ack. Reset Request Reset Confirm Error Inactivity Test Extended Unitdata* Extended Unitdata Service*
CR CC CREF RLSD RLC DT1 DT2 AK ED EA RSR RSC ERR IT UDT XUDT* UDTS XUDTS*
m m m o m m m m m o o m m m m o o o o o o o m o o o m o o m o o m m m m m m m m m m1 m1 m m m m o o m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m m
1) Information in these fields is ignored if the protocol class parameter indicates class 2 * ANSI only
-9-
4321 0000 0001 0010 0 0 11 0100 0101 0 11 0 0 111 1000 1001 1010 1 0 11 11 0 0 11 0 1 111 0 1111 0000 1010
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0001 1111
Message Type
CIC Code
Routing Label
Spare
- 10 -
PARAMETER FIELD
M O O M M M M M M M M M M M
CVT CCR BLO BLA SUS CGB CGBA GRS IAM INR INF CRA CRM COT ACM EXM ANM CPG FOT REL CFN CVR RLC RSC UBL UBA RES CGU CGUA GRA CQR CQM LPA UCIC
Message Type
Access Transport
Business Group
O O
Call Reference
Charge Number
Carrier Identification M M M O M M O
- 11 M
Cause Indicators
CLLI Code
Connection Request
Continuity Indicators
Egress Service
Event Information O
Generic Address
Generic Digits
O O
PARAMETER FIELD
CVT CCR BLO BLA SUS CGB CGBA GRS IAM INR INF CRA CRM COT ACM EXM ANM CPG FOT REL CFN CVR RLC RSC UBL UBA RES CGU CGUA GRA CQR FAC CQM LPA UCIC
Generic Name
Hop Counter
Information Indicators
Jurisdiction Information
Network Transport
Notification Indicator
- 12 M M M O
M
O M
Precedence
Redirection Information
O O O
Redirecting Number
Remote Operations
Service Activation
Service Code
Suspend/Resume Indicators
Transaction Request
O O
User-to-User Indicators
User-to-User Information
Message
IAM
SAM
IN
IN
COT
ACM CO
CP
ANM
FOT
RE
RL
F O O
F O O
F O O
F O O
F O O O
F O O O V F V F V O
O O
O V O F
O O
O O
O O
O O
- 13 O O O F O F
F O O O O O O O O
O O
O O
O F
O O
F O O O O
O O
O O
O O O
PARAMETER FIELD Message Type Access Delivery Information Access Transport Automatic Congestion Level Backward Call Indicators Call Diversion Information Call History Information Call Reference Called Party Number Calling Party Number Calling Party's Category Cause Indicators Circuit Group Supervision Message Type Ind. Circuit State Indicator CUG Interlock Code Connected Number Connection Request Continuity Indicators Echo Control Information End of Optional Parameters Event Information Facility Indicator Forward Call Indicator Generic Digit Generic Notification Ind. Generic Number Generic Reference Information Indicators Information Request Indicators
F = Mandatory fixed length parameter V = Mandatory variable length parameter O = Optional parameter, fixed or variable length
Message
IAM
SAM
IN
IN
COT
ACM CO
CP
ANM
FOT
RE
RL
CC RS LPA
PARAMETER FIELD O O O O O O O
O F O
O O
O O
O O
O O
Location Number Message Compatibility Information MCID Response Indicator MCID Request Indicators MLPP Precedence Nature of Connection Indicators Network Specific Facility Optional Backward Call Indicators Optional Forward Call Indicators Original Called Number Originating ISC Point Code Parameter Compatibility Information Propagation Delay Counter Range and Status O V V V V O O O O
O O O O O
- 14 F O O
O O
Redirection Number
O O O
O O
O O O
O O O
O O O
O O O
O F O O
Redirection Number Restr. Remote Operations Service Activation Signaling Point Code Subsequent Number Suspend/Resume Indicators Transit Network Selection Transmission Medium Requirement Transmission Medium Requirement Prime Transmission Medium Used User Service Information
O O O
O O
O O
O O
O O
O O
F = Mandatory fixed length parameter V = Mandatory variable length parameter O = Optional parameter, fixed or variable length
Message Type Address Complete Answer Blocking Blocking Acknowledgment Call Modification Completed Call Modification Reject Call Modification Request Call Progress Circuit Group Blocking Circuit Group Blocking Acknowledgment Circuit (Group) Query Circuit (Group) Query Response Circuit Group Reset Circuit Group Reset Acknowledgment Circuit Group Unblocking Circuit Group Unblocking Acknowledgment Circuit Reservation Circuit Reservation Acknowledgment Circuit Validation Response Circuit Validation Test CUG Selection and Validation Request CUG Selection and Validation Response Charge Information Confusion Connect Continuity Continuity Check Request Delayed Release Exit Facility Facility Accepted Facility Deactivated Facility Information Facility Reject Facility Request Forward Transfer Identification Request Identification Response Information Information Request Initial Address Loop Back Acknowledgment Network Resource Management Overload Pass-along Release Release Complete Reset Circuit Resume Segmentation Subsequent Address Suspend Unblocking Unblocking Acknowledgment Unequipped CIC User Part Available User Part Test User-to-user Information
Code 00000110 00001001 00010011 00010101 00011101* 00011110* 00011100* 00101100 00011000 00011010 00101010 00101011 00010111 00101001 00011001 00011011 11101010* 11101001* 11101011* 11101100* 00100101* 00100110* 00110001** 00101111 00000111 00000101 00010001 00100111* 11101101* 00110011 00100000 00100010* 00100011* 00100001 00011111 00001000 00110110** 00110111** 00000100 00000011 00000001 00100100 00110010 00110000 00101000 00001100 00010000 00010010 00001110 00111000 00000010 00001101 00010100 00010110 00101110 00110101 00110100 00101101
- 15 -
Code 00101110** 00000011 00100111 00010001 11000110* 00110110** 00101101** 00010111* 00000001 00000100 00001010 00001001 11000101* 11101110* 00010010 11101011* 00100101* 11100101* 00010101 11101000* 00100110 11100110* 00011100* 00011010 11101001* 00100001 00001101 00010000 00110111** 11000011* 00000000 00100100 00011000 00011001* 00000111 01000001** 11000000* 11000001 11000111* 00101100** 11000000** 01000010** 00111101 00011011* 00001111 00001110 11000100* 00111111** 00111011** 00111100** 00111000** 00111010** 00000110 00101111** 11101111* 11100001*
- 16 -
Code 11000010* 00101001 00001000 00101000 11101010* 00101011** 11100111* 00111001** 00111010* 00110001** 00010110 00001011 00010011 00001100 01000000** 00110010 00110011 11101100* 00011110 11101101* 00000101 00100010 11100011* 00100011 00000010 00111110** 00110101 00011101 00110000 00110100** 00101010 00100000
- 17 -
MSG Group
H1
H0
0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111
IAI
- 18 -
FAM FSM BSM SBM UBM CSM CCM GRM UNN LOS SST ACB DPN MPR EUM CCL RSC HGU HUA GRS GRA SGB SBA SGU SUA
CNM
0000 0001 0010 0 0 11 0100 0101 0 11 0 0 111 1000 1001 1010 1 0 11 11 0 0 11 0 1 111 0 1111
ACC
SS7 References CCITT White Book, Volume VI, Fascicle VI.7, Recommendations Q.700-Q.716: Specifications of Signalling System No. 7. CCITT White Book Volume VI, Fascicle VI.8, Recommendations Q.721-Q.766: Specifications of Signalling System No.7. ITU White Book, ITU-T Recommendation Q.763: Specifications of Signalling System Number 7. GR-246-CORE, Issue 1, December 1994: Specifications of Signalling System Number 7.
Even though the specifications herein may resemble specifications, descriptions or requirements of third parties or portions thereof, nothing herein shall be deemed, expressly or by implication, to be a warranty by such third parties or an endorsement by any of them or concurrence by any of them in any representation with respect to the SS7 Pocket Guide developed by TEKELEC, its employees or agents.
- 21 -
Corporate Headquarters 26580 West Agoura Road Calabasas, California 91302 Tel +1.818.880.5656 Fax +1.818.880.6993
5200 Paramount Parkway Morrisville, North Carolina 27560 Tel +1.919.460.5500 Fax +1.919.460.0877
2425 N. Central Expressway Richardson, Texas 75080 Tel +1.972.301.1300 Fax +1.972.643.4510