KUNI VODOVOD

OBUHVATA SVE ELEMENTE VODOVODNE INSTALACIJE, OD PRIKLJUKA NA ULINOJ MREU DO POSLEDNJEG POTROAA U ZGRADI SASTOJI SE OD : 1.VODOVODA MOKRIH VOROVA 2.VODOVODA VERTIKALNOG RAZVODA 3. HORIZONTALNOG RAZVODA SA PRIKLJUKOM NA UL.MREU

OZNAKE ZA VODOVOD U PROJEKTU

VODOVOD MOKROG VORA POINJE OD VERTIKALE HORIZONTALNIM ODVAJANJEM :

1. NA 30CM IZNAD PODA 2. U VISINI TOEEG MESTA 3. U PODU

...O EMU TREBA VODITI RAUNA KADA SE PROJEKTUJE MOKRI VOR ?...

RAZVOD VODOVA U MOKROM VORU IMA PAD OD 1% PREMA VERTIKALI ZA VODOVE PO SPRATU KORISTITI CEVI PROFILA 15MM ili COLA ISPRED SVAKOG TOEEG MESTA POSTAVITI ODGOVARAJUI VENTIL

...KAKO SE PRIKAZUJE RAZVOD VODOVA NA CRTEU?... IZOMETRIJSKIM CRTEOM


1. SVI HORIZONTALNI VODOVI U OSNOVI OSTAJU HORIZONTALNI NA CRTEU.SVE VERTIKALE I VERTIKALNI VODOVI SE PRIKAZUJU VERTIKALNO. 2. LINIJE KOJE SU UPRAVNE NA HORIZONTALU U OSNOVI SE CRTAJU POD UGLOM OD 30 ili 45. 3. DUINE VODOVA SE OBELEAVAJU U REALNIM MERNIM JEDINICAMA /CM,M/

...KAKO SE IZRAAVA KOLIINA UTRONE VODE NA TOEEM MESTU?...


SVAKO TOEE MESTO TROI ODREENU KOLIINU VODE, TO SE IZRAAVA KROZ MERU JEDINICA OPTEREENJA JO predstavlja koliinu vode koja protie kroz cev od 15mm pod pritiskom od 5 bara 1JO = 0.25 l/sec OD NJE ZAVISI I DIMENZIONISANJE CEVI KOJE SE RADI PREMA BRIX-OVIM TABLICAMA

VERTIKALNI RAZVOD
ON SE SATOJI OD:

VERTIKALA i SPRATNIH OGRANAKA VODODNE VERTIKALE: PO POLOAJU PRATE KANALIZACIONE VERTIKALE NJENA DUINA JE OD HORIZ.RAZVODA DO NAJVIEG IZLIVNOG MESTA /NIM-na slici./ U ZGRADI

U DNU SVAKE VERTIKALE TREBA POSTAVITI PROPUSNO ISPUSNE VENTILE /PRANJENJE MREE I MOGUNOST INTERVENCIJE/ ONA NE MORA IMATI ISTI PROFIL PO CELOJ VISINI, VE SE ON DIMENZIONIE PO BRIKSOVIM TABLICAMA

MOGUI POLOAJ NAINI CRTANJA VERTIKALA


kanalizaciona vertikala vodovodna vertikala

HORIZONTALNI RAZVOD

HORIZONTALNI RAZVOD POINJE OD ULINOG PRIKLJUKA /SPOJA/ IDE UPRAVNO NA OBJEKAT VODOMER SE POSTAVLJA NA CEV KOJA IDE OD SPOJA NA 1-1,5 M OD REGULACIONE LINIJE PORED OBJEKTA ILI U SAMOM OBJEKTU KADA PROBIJE FASADNI ZID, CEV SE DIE UPRAVNO DO 30 CM ISPOD PLAFONA PODRUMA GDE SE RAZVODI DO MESTA VODOV.VERTIKALA / W/ AKO OBJEKAT NEMA PODRUM CEVI SE VODE ISPOD PODA PRIZEMLJA, ALI ONDA SE CEVI DODATNO OBLAU I ZATIUJU OD KOROZIJE

PRIKAZ RAZVODA VODE U OBJEKTU

VODOMER

MERI POTRONJU VODE POSTAVLJA SE U DVORITI U VODOMERNOM OKNU ili U OBJEKTU-VODOMERSKO SANDUE. MESTO MU JE NA ZIDU, U NII ILI NA KONZOLNIM NOSAIMA NA 1-1,2 M OD PODA I MORA BITI ZAKLJUANO SASTOJI SE IZ PROPUSNOG VENTILA /PREMA ULICI/ I PROPUSNO-ISPUSNOG VENTILA PREMA ZGRADI. PREKO DRUGOG VETILA MOE SE ISPRAZNITI INSTALACIJA SA VODOM ILI SNIAVATI PRITISAK U MREI I NJIM MOE RUKOVATI KORISNIK ILI VLASNIK OBJEKTA VODOMER SE MORA POSTAVITI HORIZONTLNO U OKNU KROZ OKNO SE NE SMEJU VODITI DRUGE INSTALACIJE NA DNU OKNA TREBA STAVITI SLIVNIK ZBOG VEZE SA KANALIZACIJOM DIMENZIJE OKNA I SANDUETA ODREUJU SE PRAVILNIKOM GRADSKOG VODOVODA

VODOMERNA OKNA VAN ZGRADE

VODOMERNA OKNA U ZGRADI

TOPLA VODA

LOKALNI UREAJI BOJLERI /akumulacioni,protoni/ /elektrini,plinski,solarni/ CENTRALNI UREAJI-KOTLARNICE DALJINSKO ZAGREVANJE VODE i razvod do potroaa

PRIKAZ TOPLE I HLADNE VODE NA PROJEKTU VODOVODA

...SNABDEVANJE VODOM U VISOKIM ZGRADAMA...


1. DODATHNI REZERVOARI MESTO REZERVOARA JE NA NAJVILJOJ ETAI ZGRADE JEDAN DEO ZGRADE SE SNABDEVA DIREKTNO IZ ULINOG PRIKLJUKA, A DRUGI VILJI DEO VODOM KOJA TEE SLOBODNIM PADOM IZ REZERVOARA VODA IZ ULINOG PRIKLJUKA SE VODENOM PUMPOM, PREKO VENTILA SA PLOVKOM, DOPREMA DO REZERVOARA 2. HIDROFOR UREAJI ZA POVEANJE PRITISKA POMOU KOMPRIMOVANOG VAZDUHA U KUNOJ MREI MESTO MU JE UZ OBJEKTE VELIKE SPRATNOSTI, GDE SE NE MOE OBEZBEDITI DOVOLJAN PRITISAK U MREI ZBOG VELIKE GEODETSKE RAZLIKE U VISINI NAJNIE I NAJVILJE TAKE TOEEG MESTA U OBJEKTU OBEZBEUJE NORMALAN PRITISAK GRADSKE VODOVODNE MREE

HIDROFOR

...SNABDEVANJE VODOM VISOKIH ZGRADA...


a/DODATNI REZEROVAR b/HIDROFOR

...BITNI PARAMETRI ZA PRORAUN VODOVODA I DIMNEZIONISANJE CEVI...


NA DIMENZIJE CEVI UTIE : 1.KOLIINA VODE NA MESTU IZLIVA 2.PRITISAK VODE U MREI 3.BRZINA VODE U CEVIMA DIMENZIONISANJE SE RADI PO BRIX-OVIM TABLICAMA

GUBICI U MREI: 1.TRENJE PRI PROTOKU KROZ CEVI 2.GUBITAK NA SPOJU I VODOMERU /5M VODENOG STUBA/ 3.GUBITAK NA GEODETSKU VISINU ZGRADE /RAZLIKA U KOTI IZMEU NAJVIE TAKE I NAJNIE U MREI, A TO JE KOTA SPOJA/ SLOBODAN NADPRITISAK MREE se dobija kada se od raspoloivog pritiska mree oduzme zbir svi gubitaka na mrei

ISPITIVANJE INSTALACIJE VODOVODA


PO ZAVRETKU UGRADNJE VODOV.INSTALACIJA CELA MREA SE ISPITUJE NA VODONEPROPUSTLJIVOST I ISPRAVNOST, A TEK POTOM SE ROVOVI ZATRPAVAJU IZVODI SE POSTAVLANJEM VAZDUNE PUMPE NA PROPUSNI VENTIL. CELA MREA SE PUMPA VAZDUHOM ILI VODOM I IZLAE SE ZA 50-100% VEEM PRITISKU OD RADNOG U TRAJANJU OD 36 SATI. O CELOM POSTUPKU SE PRAVI ZAPISNIK U PRISUSTVU NADZORNOG ORGANA,IZVOAA I LJUDI IZ VODOVODA

SADRAJ ELABORATA VODOVODA I KANALIZACIJE


RADI SE NA OSNOVU ARHITEKTONSKOG PROJEKTA PRVO SE RADI PROJEKAT KANALIZACIJE, PA ZATIM VODOVODA 1. 2. 3. ELABORAT SADI: PROJEKTNI ZADATAK TEH.OPIS USLOVE KOMUNALNOG VODOVODA I KANALIZACIJE 4. SAGLASNOST KOMUNALNOG VODOVODA I KANALIZACIJE 5. SITUACIJU R 1:100, R 1:200 6. OSNOVE KANALIZACIONE I VODOVODNE MREE R1:50, R 1:100 7. PRESEKE KANALIZACIONE I VODOVODNE MREE R1:50, R 1:100 8. IZOMETRIJSKA EMA VODOVODA 9. HIDRAULINI PRORAUN VODOVODNE MREE 10.PREDMER I PREDRA RADOVA