PED Professional Directive 97/23/EC - Pressure Equipment Directive

06/08/2013

Calculation of test pressure acc. to EN 13445-5


for the standard water pressure test, taking into account temperature dependent material properties without considering the fluid pressure (hydrostatic pressure) Projekt: Duvaci gara Novoprojektovani cevovod viskog pritiska 2"-SS-9601-0 Wall thickness emin: Max. allowable temp.Ts: Max. allowable pressure Ps: Design pressure Pd at Td: Material: 5.13 mm 412 C 47 bar 45.5 bar

P265GH (1.0425)( EN 10216-2:2002 )

Type of material: Non austenitic steels acc. to EN 13445-3, 6.2 with A < 30% Testing group: Design stress Testing group 1-3 Calculation of test pressure

Allowable design strength fTd of design conditions at design temperature Rp0,2/T = 132.56 MPa Rm/20 = 410.00 MPa fd = fTd = 88.37 MPa

Rp0,2/T / 1.5 = 88.37 MPa

Rm/20 / 2.4 = 170.83 MPa

Allowable design strength of design conditions at proof temperature, normally 20 C Rp0,2/20 = 245.00 MPa Rm/20 = 410.00 MPa fa = 163.33 MPa

Rp0,2/20 / 1.5 = 163.33 MPa

Rm/20 / 2.4 = 170.83 MPa

Calculation of the test pressure PT in bar acc. to EN 13445-5 Pt1 = Ps * 1,43 = Pt = max(Pt1, Pt2) with Pt2 = Ps * 1,25 * fa / fTd = 105.12 bar 67.21 bar

Pt =

105.12 bar

Exceptions and special cases are to be taken into account according to EN 13445-5! In case of doubt, the original text of the DIN EN 13445 is authoritative.