Measuring Protocol

In case of a disturbance of the constant tension device, please control the marked items to determine the source of the defect:

Please measure mA at terminals 8 and 9 of the amplifier at 0 % and at 100 % load. Result: 0 % load 100 % load

Please remove the cable from terminals 10 and 11. easure the mV directl! at the clamped"off cable of the # $ rin% at 0 % and at 100 % load. Result: 0 % load 100 % load

&heck the resistance values of the # $ rin% at terminals a:11'1( ) b:1('10 ) c:10'1* ) d:1*'11. +he values should be appro,. (-0 .hm. Result: a: b: c: d:

&heck the resistance values of the # $ rin% at terminals a:1('1* and b:10'11. +he values should be appro,. /00 .hm. Result: a: b:

&heck the position of the dip s1itches $1"$* on the amplifier: Result: $1: $(: $/: $*:

easure the output volta%e of the amplifier at terminals 1( and 1*. Result: 2

&heck, 1hether the amplifier cards are correctl! screened. +he screen must be at terminal of the amplifier and terminal $ in the contactor cabinet. +he screens must not have metallic contact. 3ll amplifiers must be earthed sufficientl!. Please return the protocol to us dul! completed as soon as possible. 4e thank !ou for !our assistance.

""""""""""""""""""""""""""""""""""""""""""""" #ate, Place

""""""""""""""""""""""""""""""""""""""""""""" $i%nature