Glen E. Thorncroft Mechanical Engineering Department California Polytechnic State University San Luis Obispo
Glen E. Thorncroft Mechanical Engineering Department California Polytechnic State University San Luis Obispo
Copyright 2005 by Glen E. Thorncroft. All rights reserved. Reproduction or Translation of any part of this work beyond that permitted by Sections 107 and 108 of the 1976 United States Copyright Act without permission or copyright owner is unlawful.
Table of Contents
Chapter 1 2 page
Introduction ............................................................................................................................................. 1-1 Technical Report Format ........................................................................................................................ 2-1 2.1 Major Sections of Report ......................................................................................................... 2-1 2.2 Sample Laboratory Report ....................................................................................................... 2-5 2.3 Sample Technical Memorandum........................................................................................... 2-11 Presenting Graphs ................................................................................................................................... 3-1 3.1 Plotting Observed Data ........................................................................................................... 3-1 3.2 Empirical Relationships .......................................................................................................... 3-2 3.3 Theoretical Relationships........................................................................................................ 3-2 3.4 Graph Size................................................................................................................................ 3-3 3.5 Labeling Axes .......................................................................................................................... 3-3 3.6 Scales and Units ...................................................................................................................... 3-5 3.7 Example of Bad Graph Format............................................................................................... 3-7 Presenting Tables .................................................................................................................................... 4-1 4.1 Introduction.............................................................................................................................. 4-1 4.2 Basic Formatting Rules ........................................................................................................... 4-1 Presenting Equations............................................................................................................................... 5-1 5.1 Overview.................................................................................................................................. 5-1 5.1 Equation DOs and DONTs.................................................................................................... 5-1
Appendix A How to Make Graphs with Excel........................................................................................... A-1 Appendix B How to Make Tables with Excel and Word ...........................................................................B-1 Appendix C How to Make Equations with MS Equation Editor ...............................................................C-1 References ..................................................................................................................................................... R-1
ii
Chapter 1
Introduction
A graduate student was writing his thesis. He wanted to see if his committee would actually read his report, so on page 15, he wrote the following line: Ill bet you 20 dollars you dont get this far. Sure enough, when he presented his thesis to his committee, one of the professors interrupted him midway through the presentation: Oh, by the way, I read page 20. You owe me twenty dollars. The student, stunned, paused for a moment. Then he replied, On the contrary, sir, I think you owe me forty dollars. On page 25 I wrote Double or nothing you dont get this far. Okay, I dont know if thats a true story. Its probably an urban myth. But from the professors standpoint, I can certainly see it happening. Do you know how hard it is to read technical writing? If you want a good example, pick up just about any engineering textbook. Ive always believed that engineering writing is hard to read because engineers are not good writers. Thats not true, really. Sure, engineers probably dont develop their writing skills as thoroughly as other majors. And perhaps one of the attractions of engineering to students is the perception that writing isnt as important as technical skill. But the main reason technical writing is so hard to read is simple: technical writing is hard to do. The startling truth is that you will probably spend more time communicating in your job than designing. In your job, you may use that Partial Differential Equations textbook now and again, but how often do you think you will spend in front of the computer, writing letters, memos, and reports? And who do you think will be more successful in their career, a good engineer with poor writing skills, or a mediocre engineer with outstanding writing skills? The purpose of this manual is to introduce you to the mechanics of writing one type of engineering document: a Laboratory (or Experiment , or Test) Report. This work focuses more on the format and presentation of reports than on writing style or strategy; later versions of this manual will discuss these topics as well. In order to better prepare you for the real world, this manual draws from a variety of texts on the subject, including manuals written by organizations like NASA and Allied Signal, who teach the same kind of report writing. Although format and even technique vary from company to company (and instructor to instructor), this manual discusses a typical format and approach to this kind of report. The skills you learn here should make the reports you write for later courses easier and of higher quality. One thing to remember: never stop improving your communication skills. You advertise yourself with everything you write for your boss, your client, and your peers.
1-1
Chapter 2
Report Format
How you prepare your laboratory report will depend on the course you are taking, department, even the individual instructor. Some reports will be written individually, others by a group, as specified in each laboratory. Some laboratories will require a complete laboratory report, but others will only require some sections. An instructor will typically establish the format he expects for the course at the beginning of the quarter. The following discussion lists the various sections that make up a laboratory report. Not all instructors require every section to be included; formats will vary from department to department and instructor to instructor. Nonetheless, this list serves as a guide to the format of the various sections you will likely encounter in your studies. Be sure to check your instructors requirements before writing your report.
2-1
should be consistent throughout the report (all SI units, for example). Any or all of these sections are sometimes required at the discretion of the instructor.
Abstract
The purpose of an abstract (or summary) is to briefly summarize the entire paper, including the introduction, the procedure, the results, and even the main conclusions. Think of the abstract as the portion of the report your boss will read to decide if wants to read further. Often this is all he or she will read. For this reason the abstract should stand alone; this means that you should not refer directly to figures, tables, appendices, or any other portion of the report in the abstract. The abstract can vary in size but typically be less than a half a page, and include the following: a. the scientific context of your experiment (summarize your introduction) b. what you did c. how you did it (brief mention of the methods used) d. what you found (summarize the main results and important data) e. what it means (summarize your conclusions) One last note: since the abstract is a summary of the entire report, it stands to reason that you want to write it last. Dont waste your time writing this section until you have the rest of the report complete.
Introduction
Provide background information so that a reader will understand the purpose of your experiments, as well as the context of the experiment. By context, you want to bring the reader in to your work to provide them with the proper perspective. For example, you can merely say that you calibrated a thermocouple in this experiment, but why did you do this? The reader should know that in during flight tests of a Stealth Bomber, peculiar temperatures were indicated on the engines afterburner, and after extensive engine testing showed no physical defects, the thermocouples were suspected to be out of calibration. You may discuss and cite specific experiments done by others if germane to the present study. What are the questions you are asking, and why are they worth asking? Finally, explain the purpose of your experiments. Note that, for the purpose of the course you are taking, some instructors prefer that you merely state the objective of the experiment instead of writing a complete introduction, since the background and context are merely that you are required to perform this experiment.
2-2
Experimental Procedure
Summarize the procedure that you performed in your own words. You must not write it as instructions, nor should you merely repeat the procedure listed in the laboratory notebook. Instead, write in past tense, for example: The pump was started, and the throttle valve adjusted to obtain the highest flow rate. Measurements of flow rate, turbine inlet pressure, and exit water height were recorded. Using the output of the flow meter as the controlling variable, measurements were repeated over increments of approximately 100 liters per minute A simple listing of equipment is usually not necessary and is never sufficient. A knowledgeable scientist should be able to repeat your experiments after reading this section. Any statistical analyses and software used for data analysis should be mentioned at the end of this section. Cleaning up instructions are not needed. Provide a sketch of the experimental apparatus, depicting and labeling all measurement devices, fluid inlets and outlets, and so forth.
Results
In this section, summarize your data in graphs and tables as appropriate. DO NOT SIMPLY LIST YOUR RAW DATA AND SHOW YOUR GRAPHS. You should include all pertinent tables and figures that you wish to discuss in your report, but you must discuss what these are to the reader. Imagine you are watching the weather report on the evening news. Does the meteorologist simply show the weather map and say, Heres your weather. Back to you, Bob? No! He or she explains what the graph is about. Graphs and diagrams are numbered consecutively as Figure 1 to Figure X, and Tables are numbered separately from the graphs and diagrams as Table 1 to Table X. Label the axes or columns and define all treatments including units. Labels such as "Data sets 1,2,3, and 4" are not sufficient. Each figure and table requires a caption, a succinct statement that summarizes what the entire figure is about; for example, "Figure 1. Variation of Volumetric Flow Rate with Inlet Pressure for an Axial Fan." Never write simply Figure 1. Volumetric Flow Rate vs. Inlet Pressure. This is not descriptive enough. A figure caption appears below the figure, while a table caption appears above a table. Tables and graphs alone do not make a Results section; supporting text must be included. In the text for this section, describe your results (do not list actual numbers in your writing, but point out trends or important features, including whether the trends make sense physically). Refer to the figures and tables by number as well as any other relevant information. "See Figures" is not sufficient. Briefly interpret any analyses. Results are typically not discussed much more in this section unless brief discussion aids clarity. If you experienced technical difficulties, you might describe your expectations rather than your actual data or consult with the laboratory instructor. Some instructors merely want to see your graphs and tabular results in the Results section, deferring all discussion to the next section. In that case, a short paragraph should still be included to explain what data is presented in the graphs and tables. 2-3
Discussion
Describe each general result very briefly and discuss any expected and unexpected findings in light of the specific literature or theory that prompts your expectations. Describe those technical factors that you believe might help the reader interpret your data. Critique the experimental design. Does it adequately address the hypotheses being tested? Were there faulty assumptions in the design that confound your interpretation of the data? What new questions are prompted by the results? If your particular experiment failed, what would you do next time to make it work? Include in your text a page or two of answers to specific questions if listed in the laboratory handout. It is usually a good idea to reflect on these questions as you are obtaining your data. There is sometimes only a subtle difference between the Results and Discussion sections, and it often makes sense to merge these two sections into one called Results and Discussion. But remember that there are still two separate goals to be accomplished here: to simply display the results, then to interpret them.
Conclusions
Often a Conclusions section ends the body of the report. It is a summary of the results and discussion, and highlights the major findings of the report. This is similar to the abstract, and in fact seems somewhat redundant; but the conclusions focus mainly on the results of the report, while the abstract is a condensation of the entire report.
References
Provide a complete alphabetized list of references that you cited within your report. The laboratory handout is only a beginning. Seek out original sources, using the references given in laboratory as an entry into the literature.
Appendices
Appendices should include the following sections, where applicable: 1. Full analyses that are summarized in the text. Often this appendix may be written by hand, and must begin with a schematic diagram of the system being analyzed. It must include the general form of the governing equation; a complete listing of assumptions; a free-body diagram, control volume, or similar analysis diagram as necessary; and a complete description of the derivation leading to the final equations. 2. Spreadsheets. All spreadsheets containing calculations should be included. All data should be described, including units. 3. Sample Calculations. All calculations within or outside of the spreadsheets must be demonstrated in this section. For data appearing in columns of a spreadsheet, it is necessary only to choose one row of data to calculate, and proceed to calculate the data appearing in each column of that row. All sample calculations are to be written by hand.
2-4
2-5
Report:
Measurement of Velocity Profile and Volumetric Flow Rate in a Circular Air Duct Stan Marsh Partners: Eric Cartman Kenny McCormick Kyle Broslowski ME 236-03 September 14, 2010 Abstract In this experiment, the velocity profile and volumetric flow rate was measured in a 6 in. diameter circular air duct. Flow through the duct was produced by an axial fan attached to one end of the duct. Flow profiles were measured by traversing the duct with a Pitot-static tube. Volumetric flow rates were determined by integrating the velocities measured across the duct. Velocity data are tabulated and plotted in the report. The volumetric flow rate was measured to be 504 CFM, and the shape of the velocity profile suggests that the flow is turbulent. Introduction The objective of this experiment is to use a Pitot-static tube to measure the velocity profile of air moving through a 6-inchdiameter circular air duct, and to determine from this data the volumetric flow rate. Theory A Pitot-static tube measures the difference between the dynamic pressure and the static pressure in a fluid stream. This pressure difference can be used to determine the velocity of the stream by:
V =
2"p , !
(1)
where
!p
is the pressure difference and ! is the density of the flowing fluid. This expression is derived from the Bernoulli
Equation; this derivation is presented in Appendix A. In this experiment, the flowing fluid is air, and the pressure difference is measured with a water-filled manometer. Therefore Eq. (1) can be expressed as
V=
2 ! w gh , !a
(2)
where ! w is the water density, g is gravity, and h is the height difference of the water. The density of the flowing fluid is now expressed as ! a to differentiate it from that of the water.
Experimental Apparatus and Procedure A schematic diagram of the experimental apparatus is depicted in Figure 1. The apparatus is a Tecquipment Model 1500 Axial Flow Bench, and consists of a 6 inch diameter duct attached to the inlet of an axial fan. A Pitot-static probe is installed 18 inches behind the inlet and straightening vanes.
18 in..
Pitot-static tube
Flow
Straightening vanes
Figure 1. Diagram of Tecquipment axial flow bench used in this experiment (not to scale).
2-6
The Pitot-tube was connected to an inclined manometer, and the probe was moved to the center of the duct. The probe was secured in this position by tightening a lock screw where the probe enters the side of the duct. Care was taken to be sure that the end of the probe was aligned parallel to the airflow. The axial fan was then turned on, and allowed to reach steady-state flow. The height difference in the manometer was then read. The probe was then moved from the duct centerline a distance of 0.25 inch, and another reading was taken. This process was repeated until the probe reached the wall of the duct. It is noted that the last velocity measurement occurs 2.90 in. from the duct centerline, not precisely at the wall of the duct. This is due to the thickness of the probe. Results and Discussion Table 1 lists the manometer readings and calculated velocities at each probe location in the duct. The raw and reduced data appear in an Excel spreadsheet, presented in Appendix B, while sample calculations appear in Appendix C. The probe location was measured with an uncertainty of 0.005 in., which is the same as the resolution of the device. The manometer had a resolution of 0.01 in. H20, but the uncertainty in the measurement was estimated at 0.05 in. because of fluctuations in the height. Using this estimate of uncertainty, the velocity measurement was estimated at 2.7 ft/s, which was the worst-case value among all the measurements of velocity. The volumetric flow rate was found to be 504 ft3/min. This was determined by multiplying each measurement of velocity by its local area, and adding the individual flow rates together. The details of this calculation are presented in Appendix B. Table 1. Measured pressure drop and calculated velocities for Pitot-static tube. Radius, r Manometer ht., h Velocity, V (in.) (in.H2O) (ft/s) 0.005 in. 0.05 in. H2O 2.7 ft/s 0.00 0.53 48.3 0.25 0.56 49.6 0.50 0.63 52.6 0.75 0.59 50.9 1.00 0.61 51.8 1.25 0.49 46.4 1.50 0.45 44.5 1.75 0.54 48.7 2.00 0.56 49.6 2.25 0.39 41.4 2.50 0.33 38.1 2.75 0.33 38.1 2.90 0.14 24.8 Figure 1 depicts the measured velocity as a function of position in the duct. Generally the data is non-linear (somewhat parabolic), with the maximum velocity occurring near the centerline of the duct and the minimum occurring near the wall. In fact, the maximum velocity was seen at 0.5 in. from the centerline, although the variation of velocity in that region is close to the uncertainty in the measured velocity itself. The fact that the velocity drops off near the wall makes sense, since the velocity is in fact zero at the wall because of the no-slip condition.
Figure 1. Measured velocity through circular duct, as a function of distance from duct centerline. The shape of the velocity profile suggests that the flow is turbulent. First, the velocity profile is somewhat parabolic, but nearly flat from the centerline of the duct to about two inches away. Second, the velocity decreases sharply near the wall. Both of these features are characteristic of turbulent flow. Finally, the fluctuations in manometer readings could be due to turbulence, although fluctuations will occur in any flow, laminar or turbulent.
2-7
Because the flow is driven by an axial fan, it is possible that the air inside the duct may be rotating, or swirling, despite the presence of the straightening vanes in the duct. This would affect how we interpret the velocity of the air, but not the volumetric flow rate. The Pitot-static probe measures velocity only in one direction, in this case along the axis of the duct. Since only one component of velocity is being measured, the actual velocity may be higher. On the other hand, the volumetric flow rate depends only on the axial component of velocity, since that is the only component that contributes to moving the fluid in or out of the duct. Therefore, the rotation of the fluid does not contribute error to the measurement of volumetric flow rate. Conclusions In this experiment, the velocity profile and volumetric flow rate was measured in a 6 in. diameter circular air duct. The volumetric flow rate was measured to be 504 CFM, and the shape of the velocity profile suggests that the flow is turbulent. The effect of flow rotation was considered qualitatively: Measurements using the Pitot-static tube, which in this experiment only measured axial velocity, would underpredict the true velocity of the flow. However, this method would not adversely affect the measurement of volumetric flow rate, since its value is based solely on the axial component of velocity. References Thorncroft, G.E., Experiments in Thermal Systems, 1st Edition, El Corral Publications, 2001.
2-8
Measured Data r, in. 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 2.90 h, in.H2O 0.53 0.56 0.63 0.59 0.61 0.49 0.45 0.54 0.56 0.39 0.33 0.33 0.14
Calculations V, ft/s by Eq.(1) 48.3 49.7 52.7 51.0 51.8 46.4 44.5 48.8 49.7 41.4 38.1 38.1 24.8 nodal area, vol. Flow rate A (ft^2) Q=V*A 3.41E-04 0.99 2.73E-03 8.12 5.45E-03 17.24 8.18E-03 25.02 1.09E-02 33.92 1.36E-02 38.00 1.64E-02 43.70 1.91E-02 55.85 2.18E-02 65.00 2.45E-02 61.02 2.73E-02 62.37 3.00E-02 68.61 1.60E-02 23.87
ft^3/min
2-9
2-10
2.3 Sample Technical Memorandum A technical memorandum is a shorter version of a technical report. Below is the same report as before, presented in memorandum format.
MEMORANDUM
To: From: Date: Dr. Glen E. Thorncroft, Mechanical Engineering Department William Blazejowski (initial by your name) Charles Lumley (initial by your name) January 1, 2005
Subject: Measurement of Velocity Profile and Volumetric Flow Rate in a Circular Air Duct 1. Objective The objective of this experiment, performed in the Fluid Mechanics Laboratory on January 5, 2005, was to use a Pitot-static tube to measure the velocity profile of air moving through a 6-inch-diameter circular air duct, and to determine from this data the volumetric flow rate. Flow through the duct was produced by an axial fan attached to one end of the duct. Flow profiles were measured by traversing the duct with a Pitot-static tube. Volumetric flow rates were determined by integrating the velocities measured across the duct. Velocity data are tabulated and plotted in the discussion that follows. 2. Apparatus and Procedure A schematic diagram of the experimental apparatus is depicted in Figure 1. The apparatus is a Tecquipment Model 1500 Axial Flow Bench, and consists of a 6 inch diameter duct attached to the inlet of an axial fan. A Pitot-static probe is installed 18 inches behind the inlet and straightening vanes. The detailed operating procedure for the experiment is listed in Reference [1].
36 in. 6 in. dia. 18 in..
Pitot-static tube
Flow
Straightening vanes
Figure 1. Diagram of Tecquipment axial flow bench used in this experiment (not to scale). 3. Results and Discussion Table 1 lists the manometer readings and calculated velocities at each probe location in the duct. The raw and reduced data appear in an Excel spreadsheet, presented in Attachment 1, while sample calculations appear in Attachment 2. The probe location was measured with an uncertainty of 0.005 in., which is the same as the resolution of the device; the manometer had a resolution of 0.01 in. H20, but the uncertainty in the measurement was estimated at 0.05 in. because of fluctuations in the height. Using these estimates of uncertainty, the velocity measurement was estimated at 2.7 ft/s, which was the worst-case value among all the measurements of velocity. The volumetric flow rate was calculated to be 504 ft3/min. This was determined by multiplying each measurement of velocity by its local area, and adding the individual flow rates together. The details of this calculation are presented in Attachment 2. Table 1. Measured pressure drop and calculated velocities for Pitot-static tube. Manometer ht., Velocity, h V Radius, r (in.) (in.H2O) (ft/s) 0.005 in. 0.05 in. H2O 2.7 ft/s 0.00 0.53 48.3 0.25 0.56 49.6 0.50 0.63 52.6 0.75 0.59 50.9 1.00 0.61 51.8 1.25 0.49 46.4 1.50 0.45 44.5 1.75 0.54 48.7 2.00 0.56 49.6 2.25 0.39 41.4 2.50 0.33 38.1 2.75 0.33 38.1 2.90 0.14 24.8 1
2-11
Figure 1 depicts the measured velocity as a function of position in the duct. Generally the data is non-linear (somewhat parabolic), with the maximum velocity occurring near the centerline of the duct and the minimum occurring near the wall. In fact, the maximum velocity was seen at 0.5 in. from the centerline, although the variation of velocity in that region is close to the uncertainty in the measured velocity itself. The fact that the velocity drops off near the wall makes sense, since the velocity is in fact zero at the wall because of the no-slip condition. The shape of the velocity profile suggests that the flow is turbulent. First, the velocity profile is somewhat parabolic, but nearly flat from the centerline of the duct to about two inches away. Second, the velocity decreases sharply near the wall. Both of these features are characteristic of turbulent flow. Finally, the fluctuations in manometer readings could be due to turbulence, although fluctuations will occur in any flow, laminar or turbulent. Because the flow is driven by an axial fan, it is possible that the air inside the duct may be rotating, or swirling, despite the presence of the straightening vanes in the duct. This would affect how we interpret the velocity of the air, but not the volumetric flow rate. The Pitot-static probe measures velocity only in one direction, in this case along the axis of the duct. Since only one component of velocity is being measured, the actual velocity may be higher. On the other hand, the volumetric flow rate depends only on the axial component of velocity, since that is the only component that contributes to moving the fluid in or out of the duct. Therefore, the rotation of the fluid does not contribute error to the measurement of volumetric flow rate.
2-12
Chapter 3
Presenting Graphs
Graphs supplement, simplify, or clarify the text of a report. Often, graphical data are the primary result of a report. The purpose of this section is to introduce basic rules and techniques for creating graphs for laboratory reports.
Current (mA)
Voltage (V)
Figure 3.1. A typical set of measured data. Sometimes, however, it is appropriate to connect the points using straight lines (straight lines unless the general shape of the trend is known). This is appropriate, for example, when the sequence of the data points is important, as in the following example.
120
Hardness (Rockwell)
3-1
1.5
Current (A)
1.0
0.5
0.0 0 10 20 30 40 50
Voltage (V)
300
200
100
0 0 1 2 3 Time (s) 4 5
3-2
3-3
0.35
0.30
0.25
Torque, T (N-m)
0.15
0.10
0.05
Torque Power 2nd order curve fit Linear curve fit 0 100 200 300 Rotational Speed (RPM) 400 500
0.00
0 600
3-4
Power, P (W)
0.20
100 90 80 70 60 50 40 30 20 10 0 2000
2500
3000
3500
4000
4500
5000
5500
3-5
(a) Figure 3.7. The effect of choice of scale. 3.5.2 Numerical Format and Significant Figures
(b)
The digits used to label axes should be kept to a minimum and written without ambiguity. For example, consider the plot shown in Figure 3.8. Both axes labels have too many decimal places. Aside from the fact that the extra digits crowd the axes, making them harder to read, the extra digits are not warranted. For example, looking at Figure 3.8, would you be able to find point (3.01, 5.198)? No, because the plot is not that accurate. The rule of thumb is to choose the decimal place for the axes based on whether you could read to that accuracy on the plot. Very large or very small numbers should be plotted in scientific notation, as demonstrated in the third example above. Alternately, you could plot data ranging from 1,000 to 10,000 on a scale from 1 to 10, by titling the axis Variable (Symbol) x 104. Finally, be careful not to divide an axis into too many increments, as illustrated in Figure 3.9.
3-6
4.0000 3.5000 3.0000 2.5000 2.0000 1.5000 1.0000 0.5000 0.0000 0.00 5.00 10.00 15.00 20.00
3.6 3.4 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0
10
20
3-7
Series1
5
2
3
Linear (Series1)
1. Center the title, and place it on the bottom of the graph. DO NOT USE THE TITLE FEATURE DEFINED BY EXCEL! Use the same font as you used in the body of the text (i.e., dont use bold font). Use a descriptive title for the figure, not just a vs. b. 2. Remove the border from the figure. 3. Reduce the size of your fonts to approximately 10 or 11 point. You may make the font size of your legend smaller. 4. Make the plot area larger, to approximately the size of the border above. Move the legend inside the plot area. 5. Give the data descriptive names, not just Series 1" or Linear (Series 1), which are meaningless. 6. Include a name, symbol, AND units in the axis titles, not just F and x. 7. Do not use a background color for the plot (set it to none). In fact, set the colors of all lines and symbols to black and white. Colors do not copy well, and often are hard to distinguish. Do not assume that the plot will look fine if you simply print colors in grayscale! 8. Set the axis scales reasonably! For example, the x-axis above should perhaps range from 0 to 3, with increments of 0.5. 9. Minor axes can add unnecessary tedium to graphs. Remove them unless necessary for interpretation of results. 3-8
Chapter 4
Presenting Tables
4.1 Introduction
A table is a collection of rows and columns of information (usually numerical data). A table comes in handy when the data you are discussing is too complicated or large to present within the text. Tables also allow you to arrange the data in a more simple, logical, or even more persuasive form. Graphs serve a similar function, but some data are not easy to graph, and even if they are, the reader is often interested in the raw data as well. But heres the problem with tables: if you dont make it easy to read, the reader will glance at it, his or her eyes will glaze over, and youve lost them and the whole point of the data. Ask yourself: why should the reader be interested in this data? Whats the point of this data? What important point does it show that makes it worth the readers time to read? Tables are not as easy to put together as you might think. Sure, there are some basic rules we can (and will) follow, but organizing and presenting data in a table is often as difficult as organizing and presenting your written report. Well first present some basic rules in Section 4.2. The remaining section will list some of the more subtle aspects of data presentation.
This table obeys some basic rules of presentation, which we will now list: 1. The table is referred to (and discussed!) in the body of the report. Otherwise how would the reader find it? How would they connect it to what you are writing about? 2. The table is numbered (in this case, 1). 3. The table number and title appear at the top of the table. This is just a conventional format. 4. The title is meaningful (not simply displacement vs. force), and gives considerable detail as to what the measurements represent. This may seem redundant, given that the table will be
4-1
5. 6. 7. 8. 9.
discussed thoroughly in the body of the report. You try driving from San Luis Obispo to Las Vegas in the middle of the night. Wouldnt you like a few reminders youre still on Highway 58? When reading a complicated technical report, a few extra signposts wouldnt kill you. The title and the table are centered. This helps set the table off from the rest of the text. The data columns are labeled, and the units are presented. Notice that in this case the spring force is presented in two units, N and lbf. Typically, you should stick to one system of units, and be consistent throughout the table (and document, for that matter). The data in a column have consistent significant digits (i.e., one decimal place in column 1, two decimal places in the others). The data are centered in their columns and aligned at the decimal point. Alignment at the decimal point makes the data much easier to scan and interpret. The arrangement of data and the selection of lines (cell borders) are simple and logical, so that relationships are clearly revealed.
Rule #8 is more a goal than a rule, but it is so critical that it seems important to list it here. In Appendix B, a step-by-step tutorial is presented on how to create and edit the above table in MS Word and Excel.
4-2
Chapter 5
Presenting Equations
Using the equation editor that comes with Microsoft Word, mathematical equations can be inserted to produce high-quality scientific reports.
5.1 Overview
Equations should be readable. Avoid the use of asterisks (*) and caveats (^) in equations; they result in sloppy-looking equations that are hard to read. For example, the equation for the volume of a sphere is (4/3)*pi*r^3. What is wrong with this equation? First, its not an equation. It should be written as an equality: V = (4/3)*pi*r^3. Now, even without an equation editor, you should at least eliminate the asterisks, and use the superscript command to eliminate the ^3 characters. Further, we can replace pi with the Greek symbol !. Finally, center the equation and add an equation number (using tabs for both). Thus, V = (4/3) ! r3. (5.1)
This can be done much simply and more professionally using an equation editor like MS Equation Editor, provided with MS Word:
4 V = ! r3 . 3
(5.2)
Note that using the equation editor enables writing equations that appear as they would in a textbook or as you might write them by hand. The utility of such a program becomes even clearer when considering an equation like the following:
#
f ( x) = !
0
cos x dx 1" x2
(5.3)
Imagine writing this equation with only a keyboard! A discussion on using MS Equation Editor in Word (along with aligning equations and equation numbers) is presented in Appendix C.
5-1
5.2 Equation DOs and DONTs DONT use caveats (^), asterisks (*), underlines (_), or any other non-standard character in your equations. DO use Equation Editor. DO number your equations. DO center your equations, and right-tab your equation numbers. DO punctuate your equations. You should treat equations like a word in your sentence, even if it appears on a separate line.
5-2
Appendix A
Spring Displacement, Spring Force, x (mm) F (N) 1 2 2.2 5.1 5.8 34.52 6.5 45 10.1 99.91 11 110
2. To make the data presentable, you would need to make the decimal place uniform throughout each column of data: a. Using your mouse, highlight the cells containing the first column of numbers, by clicking on the first cell and dragging down to the last cell. Then right-click once to obtain a pop-up menu. b. Choose Format Cells and click the menu tab called Number . c. Under Category, choose the item Number , which brings up additional information. d. Under Decimal Places, change the value in the selection box to 1. e. Then at the bottom of the Format Cells window, click the OK button. 3. Repeat Step 2 for the second column of numbers, this time changing the decimal places to 2. Note: The Format Cells pop-up menu can also be used to add borders and shading to cells, among other things.
A-1
A.2 Creating the Graph We are now ready to create a graph. Again, there are short-cuts that make creating graphs much easier and faster, but we are learning the nuts and bolts here. 1. From the pull-down menus in Excel, choose Insert=>Chart The Chart Wizard window will open. 2. Step 1 of Chart Wizard is choosing the Chart Type. Under the menu tab Standard Types, choose XY (Scatter). There are several Chart sub-types to choose from, but leave the default type as is, and click Next >. 3. In Step 2 of Chart Wizard, we will enter the data to be graphed, one series at a time. Choose the Series menu tab, and click Add. You now have an x-y series called Series 1 that you will be defining on the graph. (Note: Series 1 mat already exist; in this case, just click Remove to delete the series.) 4. Choose the name of the series. To the right of the menu box called Name: , click the little red/white/blue button. The Chart Wizard window disappears, and you may now choose a cell from the spreadsheet that contains the name of the series. Click on the cell that reads F(N) , then press enter. The Chart Wizard window will reappear. Or you can simply type the name of the series in the menu box. 5. Below the Name selection box are the selection boxes for the x-axis and y-axis series. Select the series cells just like you selected the name in step 4. 6. After selecting the x- and y-axis series, click Next >. 7. In Step 3 of the Chart Wizard, you will choose Chart Options. Under the Titles menu tab, enter the name of the x-axis: Spring Displacement, x (mm). For the y-axis, enter Spring Force, F (N). Also, delete the chart title, if one exists; you will enter a title for the graph when you import the graph into the word processor. 8. After entering titles, click Next >. 9. Finally, in Step 4 of the Chart Wizard you select the Chart Location. Leave the default location of the chart as an object in Sheet 1. Click Finish. You should now have a plot that looks something like this:
120.00
100.00 80.00 60.00 40.00 20.00 0.00 0 2 4 6 8 10 12 Spring Displacement, x (mm) F (N)
A-2
A.3 Formatting the Graph Unfortunately, the default format for an Excel graph is not typical for reports. Lets reformat the graph. Later we will define the style so we dont have to keep reformatting each time we make a graph. 1. First, change the font size on the axes and titles. Otherwise, if we resize the graph, the font size may not be appropriate. a. With the mouse cursor inside the chart box but outside of the actual graph, right-click to view a pop-up menu. b. Click Format Chart Area , and choose the menu tab Font. c. Under Size, choose 10 or 11 point font size. d. Then locate a checkbox called Auto scale and unselect it. By unselecting this box, the size of the font will not change when you change the size of the plot. e. Click OK, which returns you to the spreadsheet. 2. Next, we notice that the decimal places on the y-axis are more than you could actually read off the chart. Since this doesnt make sense we will change the decimals of the y-axis from two (e.g., 100.00) to zero (e.g., 100). a. Right-click over the y-axis labels. A pop-up menu should appear that reads Format Axis Select it. b. In the window that opens, left-click on the tab marked Number. c. Under Category, select Number. Then use the up and down arrows to change the Decimal Places to 0. d. Click OK, which returns you to the spreadsheet. 3. Next, change the background color of the plot from gray to clear. a. Right-click on the plot area, and choose Format Plot Area from the pop-up menu. b. Under Area , select the button marked None, then click OK. 4. Now lets remove the horizontal lines from inside the plot. a. Right-click on one of the horizontal lines to open a pop-up menu. b. Click Clear . The horizontal lines should disappear. At this point, the graph should look something like this:
120
A-3
5. The symbols are actually colored blue in the above graph; colored symbols can often cause confusion, especially when printed in black-and-white. Lets change the color of the symbols, and in fact make them a bit larger: a. Right-click on one of the data symbols to open a pop-up menu, and select Format Data Series... b. Under the menu tab Patterns, in a sub-menu called Marker, youll notice that the markers Foreground color has been chosen to be Automatic. Change the color to black by selecting that color from the pull-down window. c. Repeat step b for the Background color. d. Change the Size of the marker to 6. The selection is just below the Background selection. e. Click OK to exit the menu. 6. Just for the fun(?) of it, lets change the shape of the plot from rectangular to square. Just highlight the entire chart, and click and drag one of the corners to vary the shape and size of the plot. Youll notice that the text inside the chart does not change. Adjust the shape of the plot until it is square. The plot should now look like:
120
7. For aesthetics, we often move the legend to the inside of the plot. Do this by clicking and dragging the legend to the inside right bottom corner of the plot. 8. Finally, you may have noticed that all the plots printed here have a border around them. Lets remove this. a. Click on the chart (outside the plot area), right-click, and select Format Chart Area from the pop-up menu. b. Under the Patterns menu tab, and under the sub-menu Border, select None. c. Click OK to exit the menu. You will now see that the chart border has been removed. The graph should now look like:
A-4
120
100 80 60 40 20 0 0 5 10 F (N) 15
120
4. We can also display the curve-fit equation on the graph. To do this, right-click on the curve-fit line, and select Format Trendline from the pop-up menu. Select the Options menu tab, and select the box entitled Display Equation on Chart.
A-5
5. While were there, lets change the name of the curve-fit. Under the Options menu tab, beneath Trendline Name, select the box entitled Custom: , and type in 2nd order curve fit in the box. 6. Click OK. Now the graph should look like this:
120 2 y = 0.7364x + 2.3138x - 2.2646 100 80 60 40 20 0 0 5 10 F (N) 2nd order curve15 fit
120
F = 0.7364x 2 + 2.3138x - 2.2646
100
A-6
A.5 Saving the Graph Format To save time later, you can save this format and call it up later. 1. Right-click on the chart, and choose Chart Type from the pop-up menu. 2. Under the menu tab Custom Types, beneath where it reads Select From, select User-Defined. 3. Click the Add button, enter a name (and a description if you like), and click OK. The named chart type now appears under the list of custom chart types. When you make a chart, you will now be able to select this as your format when you are creating a new graph. You can even set this as your default style. A.6 Importing the Graph into Word We can now (finally) import the graph into our Word Document. 1. Open MS Word, and keep Excel open. 2. In Excel, right-click on your chart. Choose Copy from the pop-up menu. 3. Go to Word, and move the cursor to where you want to paste the plot. Right-click and choose Paste from the pop-up menu. The graph should now be in your document. 4. Write a figure number and descriptive title below it. Center both the graph and the title. Your figure should now look like this:
120
F = 0.7364x 2 + 2.3138x - 2.2646
100
A-7
Appendix B
Spring Displacement, Spring Force, x (mm) F (N) 1 2 2.2 5.1 5.8 34.52 6.5 45 10.1 99.91 11 110
We will enter this data in a table created in Word. In Section B.7, we will learn how to import this spreadsheet data directly into Word, and manipulate the format from there.
B-1
2. Make the significant digits uniform (one decimal place for the first column, two for the second). Unfortunately, Word doesnt have shortcuts for this, so youll have to change each value one-byone. The table should now look like:
1.0 2.2 5.8 6.5 10.1 11.0 2.00 5.10 34.52 45.00 99.91 110.00
3. Shrink the table to a more reasonable size. If you hold the mouses cursor over the table, two icons will appear on the table as shown below. Click and drag on the lower right icon to make the table smaller.
Changes table size
4. Center the table. You can do this one of two ways: You can click and drag the top left icon shown above; alternately, you can highlight the entire table by just clicking the same icon, then clicking the Center Justify button as before.
The table should now look something like that shown below.
1.0 2.2 5.8 6.5 10.1 11.0 2.00 5.10 34.52 45.00 99.91 110.00
B-2
2. Add a Table Title as shown below. Center the title. Note that the table is numbered, and the title is descriptive not just Force vs. Displacement. Also note that the title does not appear within the table, but above and outside it. Table 1. Measurement of spring displacement under compression.
Spring Displacement, mm 1.0 2.2 5.8 6.5 10.1 11.0 Spring Force, N 2.00 5.10 34.52 45.00 99.91 110.00
The table is complete, but there are a few more tricks we will find useful.
2. With the data cells still highlighted, click on the tab selection button on the left side of the tab bar until the Decimal Tab appears. This is shown in the figure on the next page. With Decimal Tab chosen, click and drag on the tab bar to locate the tab at the center of the column. Note that this sets the tab for all the highlighted data, not just the first column.
B-3
Your table should now look like that shown below. Table 1. Measurement of spring displacement under compression.
Spring Displacement, mm 1.0 2.2 5.8 6.5 10.1 11.0 Spring Force, N 2.00 5.10 34.52 45.00 99.91 110.00
2.
3.
B-4
Notice that a column has been added to the table, but also that the cell containing the text Spring Force spans two columns. In this section, we will learn how to accomplish this. 1. Add a column to the table: Using the table we created in Section B.5, highlight the entire second column of the table. Then right-click, and in the pop-up menu that appears, choose Insert Columns. The table now looks like that shown below. Table 1. Measurement of spring displacement under compression.
Spring Displacement, mm 1.0 2.2 5.8 6.5 10.1 11.0 Spring Force, N 2.00 5.10 34.52 45.00 99.91 110.00
2. Move the data and label in column 3 to column 2 as follows: Highlight the entire column 3, right-click, and from the pop-up menu choose Cut. The entire column will disappear. Then in the blank column that remains, right-click, and choose Paste Columns from the pop-up menu. The table should now look like the following:
B-5
3. Split the cell labeled Spring Force, N into two cells, one on top of the other. To do this, rightclick on the cell and choose Split Cells from the pop-up menu. Choose 1 column and 2 rows, then OK. Repeat this for the cell to the right, so that the table looks like: Table 1. Measurement of spring displacement under compression.
Spring Displacement, mm 1.0 2.2 5.8 6.5 10.1 11.0 Spring Force, N 2.00 5.10 34.52 45.00 99.91 110.00
Youll notice that the cell borders arent right well take care of that last. 4. Merge the cell labeled Spring Force, N with the one on its right: Highlight both cells, then rightclick and choose Merge Cells from the pop-up menu. Now, delete the text , N from that cell, and below it, label the two columns N and lbf as shown below. Enter the data in the last column. Table 1. Measurement of spring displacement under compression.
Spring Displacement, mm 1.0 2.2 5.8 6.5 10.1 11.0 Spring Force, N N 2.00 5.10 34.52 45.00 99.91 110.00 lbf 0.45 1.15 7.76 10.12 22.46 24.73
4. Finally, change the cell borders as before so that the table looks as shown below.
B-6
Spring Displacement, Spring Force, x (mm) F (N) 1 2 2.2 5.1 5.8 34.52 6.5 45 10.1 99.91 11 110
1. First, import the data into Word: While in Excel, highlight the cells containing the data and labels, and right-click. A pop-up menu will appear; choose Copy. Then open your Word file, right-click where you want to place the table, and choose Paste from the pop-up menu. The result should look something like this:
Spring Displacement, Spring Force, x (mm) F (N) 1 2 2.2 5.1 5.8 34.52 6.5 45 10.1 99.91 11 110
B-7
2. The cells are indicated by their gray borders; these borders will not appear when you print your report, so lets change the lines to black. Highlight the entire table, and right-click. Choose Borders and Shading from the pop-up menu. On the left of the Borders sub-menu, choose All. Then under Color, choose Automatic (which should be black). Your table should now look like:
Spring Displacement, Spring Force, x (mm) F (N) 1 2 2.2 5.1 5.8 34.52 6.5 45 10.1 99.91 11 110
3. At this point you can use the techniques of the previous sections to modify the table to the proper format.
B-8
Appendix C
Note: If you cant find MS Equation Editor among the list of objects to be inserted, it probably wasnt installed on your machine. MS Equation Editor comes with MS Word, but often the standard installation doesnt include it. You can install Equation Editor after the fact by running the install software that comes with MS Word.
C-1
Relationship symbols; equality; inequality; equivalence Alignment symbols; spacers; ellipsis Accents; primes; hats; dots Operators; multiplication; division; dot product Arrows
Logic symbols Set theory symbols; union; intersection; containment Miscellaneous symbols; gradient; degree; Plancks constant Lowercase Greek Uppercase Greek
C-2
will adjust automatically. If you wish to have equations appear in a paragraph by themselves, simply press Return before and after the equation. The best way to position an equation when on a separate line is to center the equation using tabs. You can also add a caption, e.g. (2.3), to the equation using tabs. This is demonstrated below:
(1)
Choose tab type (center, right, left, etc.) with this button
C-3
References
Harvill, L.R. and Kraft, T.L., Technical Report Standards, M/A Press, Forest Grove, Oregon, 1978. Ivancec, Paul C. and Hu, S., Creating Equations Using Microsoft Word, (Web Site: http://www.sas.upenn.edu/~pci/Equation/equation.html), University of Pennsylvania, 1998. Word 5.1: The Equation Editor, The Webdoc http://www.reed.edu/webdoc/Macintosh/Word/equation.html), 1998. Project (Web Site: