Storm sewer design for Maple Ave from 8th St to 4th St (S.I.

units)
col. 1 col. 2 col. 3 area increment ha 1.82 1.50 2.05 2.09 col. 12 pipe slope (Vfull = 1) m/m 0.002120 0.001575 0.001235 0.001006 col. 4 cumul. area ha 1.82 3.32 5.37 7.46 col. 13 surface slope m/m 0.00019 0.001189 0.001301 0.000234 col. 20 Vfull m/s 1 1 1 1 col. 21 Qfull m /s 0.28 0.44 0.64 0.87
3

col. 5

col. 6 inlet time

col. 7

col. 8

col. 9

Length Line 8th - 7th 7th - 6th 6th - 5th 5th - 4th col. 10 m 105 143 146 171 col. 11

tC min 18 19.8 22.1 24.6 col. 16

i mm/hr 141.50 134.62 126.25 118.72 col. 17

Qdes m3/s 0.22 0.38 0.57 0.74 0.74 0.61 0.83 0.85

C 0.3 0.3 0.3 0.3 col. 14

min 18 18 18 18 col. 15

Dpipe mm 524.8 691.4 851.5 973.2 col. 18

Dstd* mm 600 750 900 1050 col. 19

Length m 105 143 146 171 col. 22

tpipe min 1.8 2.4 2.4 2.9 col. 23 col. 24 pipe slope

Ground Elev, m upper lower 20.5 20.48 20.31 20.12 20.48 20.31 20.12 20.08

Invert Elev, m upper lower 18.400 18.027 17.652 17.322 18.177 17.802 17.472 17.150

Cover Depth, m upper lower 1.50 1.70 1.76 1.75 1.70 1.76 1.75 1.88

for design m/m 0.002120 0.001575 0.001235 0.001006

derivation of IDF equation [i = a/(b + d)] for T = 25 years, 10 min < d < 30 min: d, min 10 15 30 1/i, hr/mm 0.00535 0.00654 0.00952 i, mm/hr 187 153 105 slope = 0.000207 = 1/a a = 1/slope = intercept = The IDF equation is thus: i = 4840/(d + 16.2) 0.0033 = b/a 16.2 4840

b = a*intercept =

*Standard pipe diameters in mm: 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 650, 700, 750, 800, 850, 900, 950, 1000, 1050, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000

NOTES:

(Each line in the spreadsheet designs the pipe between two adjacent manholes assuming that the pipe flows full at design flow rate.) See manhole map below.

Col. 1: Enter information from the manhole layout map. Col. 2 & 3: Measure distance between manholes and area draining to the inlet . Col. 4 calculates the cumulative area draining to the section of pipe being designed. Col. 5: Enter the runoff coefficient value Col. 6: Enter the inlet time for the drainage area to the section of pipe being designed. Col. 7 calculates the time of concentration for the section of pipe being designed. Col. 8: enter the design storm intensity for specified return period and storm duration equal to the time of concentration. Col. 9 calculates the design stormwater flow using Q = 0.0028CiA Col. 10 calculates the pipe diameter to give V = Vmin with flow rate = Qdes, using Qdes = (Vmin)A = (Vmin)(pD2/4) ( Vmin - 1 m/s in the example )

Col. 11: Enter the next larger standard pipe diameter. Col. 12 calculates the pipe slope for Vfull = Vmin with the pipe diameter set at Dstd using the Manning equation: V = (1/n)(D/4)2/3(S1/2) (n = 0.013 in the example)

Col. 13 calculates the ground surface slope using surface elevations from Col 18 & 19. (If pipe slope > surface slope, use calculated pipe slope. If pipe slope < surface slope, set the pipe slope equal to the surface slope if needed to maintain minimum cover.) Col. 14 & 15 calculate Vfull and Qfull, using the Manning equation, with pipe diam. = Dstd and pipe slope = selected slope (pipe slope or surface slope) Col. 16 & 17 calculate the pipe flow time, using tpipe = length/Vfull. Col. 18 & 19: Enter values from the manhole map. Col. 20 & 21 calculates the invert elevation at each manhole using the ground surface elevation, minimum cover, pipe slope, and pipe diameter. (min. cover = 1.5 m in the example) Col. 22 & 23 calculate the cover depth as a check to be sure it is adequate. Col. 24: Enter the selected design slope (typically pipe slope or surface slope) This slope is used in Col 14, 15, & 21 calculations. For derivation of the IDF equation, enter data for storm duration, d, vs storm intensity, i, from an IDF graph or table for the sewer location at the specified design return period. The Excel formulas will calculate 1/i, and calculate the constants a and b for the equation, i = a/(d + b), based on linear regression of d vs 1/i. The derived equation can then be used to calculate design storm intensity, i, for Col. 8.