Professional Documents
Culture Documents
Location :
Design Structure :
Designed by :
DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: Coef. width length
Catchment Area, CA = 0.012 km² 0.5 20 1200
Pavement Surface = 0.007236 km² 0.9 6.7 1200
Shoulder = 0.00072 km² 0.3 2.0 1200
total = 0.019956 km²
Length of Main Watercourse, L = 1
Highest Elevation of drainage, He = 100
Elevation at the point of interest, El., = 99
Difference in Elevation, H = 1
Drainage Gradients, S = 0.01
2b. Determine the rainfall intensity within the time of flood concentration, mm/hr
tc = 0.220082485546 mins
Therefore,
1578.76
i =
(tc + 7.7 ) ^ 0.75 Rainfall intensity Duration curve, Return Period 2 yr.
tc
i = 196.820448869 mm/hr 0.196820448869 m/hr.
Thus,
Qd = ciA/3.6 = 0.370954060665 m³/s
CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. General waterway 0.03-0.035
b. Rapid river of wide and shallow river 0.04-0.05
c. Temporary waterway excavated without timbering 0.035
d. Three sided lined channel 0.025
e. River tunnel 0.023
X = 0.8
Y = 0.7
Qcap = 0.899687284343
Thus,
Qcap = 0.899687284343 > Qd = 0.370954060665 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: Coef. width length
Catchment Area, CA = 0.025 km² 0.5 50 1000
Pavement Surface = 0.00558981 km² 0.9 6.7 927
Shoulder = 0.0005562 km² 0.3 2.0 927
total = 0.03114601 km²
Length of Main Watercourse, L = 1
Highest Elevation of drainage, He = 466.852
Elevation at the point of interest, El., = 418.286
Difference in Elevation, H = 48.566
Drainage Gradients, S = 0.01
2b. Determine the rainfall intensity within the time of flood concentration, mm/hr
tc = 0.04935686116 mins
Therefore,
2090.54
i =
i =
(tc + 0.75 ) ^ 8.31 Rainfall intensity Duration curve, Return Period 5 yr.
tc
i = 248.4385858592 mm/hr 0.248438585859 m/hr.
Thus,
Qd = ciA/3.6 = 0.730798897514 m³/s
Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness
CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. General waterway 0.03-0.035
b. Rapid river of wide and shallow river 0.04-0.05
c. Temporary waterway excavated without timbering 0.035
d. Three sided lined channel 0.025
e. River tunnel 0.023
D B
Y
X = 1
D = 0.7
B = 0.5
Y = 0.746
Thus,
Qcap = 0.863242090139 > Qd = 0.730798897514 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
Name of project :
Location :
Design Structure :
Designed by :
DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: coef w L
Catchment Area, CA = 0.0975 km² 0.5 150 1300
Length of Main Watercourse, L = 0.8 km.
Highest Elevation of drainage, He = 101.15 m.
Elevation at the point of interest, El., = 99.8 m.
Difference in Elevation, H = 1.35 m.
Gradients, S = 0.01
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:
where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff
2b. Determine the rainfall intensity within the time of flood concentration, mm/hr
tc = 0.017027928182 mins
Therefore,
2464.1
i =
(tc ^ 0.76 + 8.76 )Rainfall intensity Duration curve, Return Period 10 yr.
Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness
3a. Manning's Coefficient of Roughness
CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. Concrete Box Culvert 0.017
1
Qcap = x A x R2/3 x S½ (m³/s)
n
Qcap = 3.670736158327
Thus,
Qcap = 3.670736158327 > Qd = 1.894778422353 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
Name of project :
Location :
Design Structure :
Designed by :
DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: coef w L
Drainage Area, CA (Waterway) = 0.0015 km² 0.5 6.00 500.00
(Lined Canal) = 0.027378 km² 0.9 25.35 1200.00
Total A = 0.028878 km²
Coefficient of Runoff C = 0.9
Rainfall Intensity from PAGASA I = 107.545 mm/hr
Length of Main Watercourse, L L = 500.00 m.
Highest Elevation of drainage, He H1 = 20.35 m.
Elevation at the point of interest, El., H2 = 16.50 m.
Difference in Elevation, H ΔH = 3.85 m.
Length of Box Culvert x = 12.00 m.
Width of Box Culvert w = 1.50 m.
Height of Box Culvert h = 1.50 m.
Manning's Roughness coefficient n = 0.017
Allowable Maximum Velocity Vmax = 5.000 m/s
Allowable Manimum Velocity Vmin = 0.500 m/s
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:
where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff
Therefore,
2808.93
I =
(tc^ 0.76 ) + 9.04 Rainfall intensity Duration curve, Return Period 20 yr.
Thus,
Qd = ciA/3.6 = 0.776422563473 m³/s
Qcap = AV
A = hxw
= 1.00 sq.m.
1
V = R⅔ S½
n
where:
R = Hydraulic Radius of channel, m
S = Slope of Channel
n = Manning's Coefficient of Roughness
1
V = R⅔ S½
n
= 3.111016 m/sec < 5.0 m/sec SAFE
Qcap = AV
Qcap = 3.111015536367
Thus,
Qcap = 3.111015536367 > Qd = 2.576422563473 OK!!!
19.63164509
53.64895259
102.8641551
1270.03446 DIPOLOG (741)
24.90263648 YR FACTOR
1.074652529
2 1578.76 0.75 7.70
0.638630298 5 2090.54 0.75 8.31
15.90357816 10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
223.328 50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
6.993007
5.333333333
2.5198421 0.666667
0.5
2.774561219
2.774561219
Name of project :
Location :
Design Structure :
Designed by :
DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA:
Catchment Area, CA = 0.0014 km²
Length of Main Watercourse, L = 0.2
Highest Elevation of drainage, He = 101.15
Elevation at the point of interest, El., = 99.8
Difference in Elevation, H = 1.35
Gradients, S = 0.01
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:
where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff
2b. Determine the rainfall intensity within the time of flood concentration, mm/hr
tc = 0.096147503452 mins
Therefore,
2464.1
i =
(tc ^ 0.76 + 8.76 ) Rainfall intensity Duration curve, Return Period 10 yr.
Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness
CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. Concrete Pipe Culvert 0.025
D = 0.61
1
Qcap = x Aw x R2/3 x S½ (m³/s)
n
Qcap = 0.358811470752
Thus,
Qcap = 0.358811470752 > Qd = 0.315217470249 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
Name of project :
Location :
Design Structure :
Designed by :
DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA:
Catchment Area, CA = 0.004 km²
Length of Main Watercourse, L = 0.5
Highest Elevation of drainage, He = 101.15
Elevation at the point of interest, El., = 99.8
Difference in Elevation, H = 1.35
Gradients, S = 0.01
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:
where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff
2b. Determine the rainfall intensity within the time of flood concentration, mm/hr
tc = 0.14425336434 mins
Therefore,
2464.1
i =
(tc ^ 0.76 + 8.76 ) Rainfall intensity Duration curve, Return Period 10 yr.
i = 3242.236658462 mm/hr 3.242236658462 m/hr.
Thus,
Qd = ciA/3.6 = 0.900621294017 m³/s
add:
Existing Discharge = 0.1 m³/s
Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness
3a. Manning's Coefficient of Roughness
CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. Concrete Pipe Culvert 0.025
D = 0.91
1
Qcap = x Aw x R2/3 x S½ (m³/s)
n
Qcap = 1.042550588904
Thus,
Qcap = 1.042550588904 > Qd = 1.000621294017 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59