You are on page 1of 26

Name of project :

Location :
Design Structure :
Designed by :

DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: Coef. width length
Catchment Area, CA = 0.012 km² 0.5 20 1200
Pavement Surface = 0.007236 km² 0.9 6.7 1200
Shoulder = 0.00072 km² 0.3 2.0 1200
total = 0.019956 km²
Length of Main Watercourse, L = 1
Highest Elevation of drainage, He = 100
Elevation at the point of interest, El., = 99
Difference in Elevation, H = 1
Drainage Gradients, S = 0.01

2. DESIGN DISCHARGE CALCULATION:

Qd = ciA/3.6 (Rational Formula Method)


where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Drainage Area (total)
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff

CHARACTERISTICS RUNOFF COEFF.


a. Lawn, gardens meadows and cultivated lands 0.05-0.25
b. Suburban districts with few building 0.20-0.30
c. Residential district not densely built 0.30-0.55
d. Residential district densely built 0.50-0.75
e. For watershed having steep gullies and not heavily timbered 0.55-0.70
f. For watershed having moderate slope, cultivated and heavily timbered 0.45-0.55
g. For suburban areas 0.34-0.45
h. For agricultural areas 0.15-0.25

Hence, use 0.34 as runoff coefficient.

2b. Determine the rainfall intensity within the time of flood concentration, mm/hr

L1.15 (Kirpich Equation) time of concentration (mins)


tc =
51H -385

tc = 0.220082485546 mins

Therefore,
1578.76
i =
(tc + 7.7 ) ^ 0.75 Rainfall intensity Duration curve, Return Period 2 yr.
tc
i = 196.820448869 mm/hr 0.196820448869 m/hr.
Thus,
Qd = ciA/3.6 = 0.370954060665 m³/s

3. DESIGN DISCHARGE CAPACITY


1
Qcap =
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness

3a. Manning's Coefficient of Roughness

CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. General waterway 0.03-0.035
b. Rapid river of wide and shallow river 0.04-0.05
c. Temporary waterway excavated without timbering 0.035
d. Three sided lined channel 0.025
e. River tunnel 0.023

Hence, use 0.025 as Roughness coefficient, n.

3b. DESIGN DIMENSIONS


x

X = 0.8
Y = 0.7

3b.1 Drainage cross-section area


A = X*Y = 0.56 m²
3b.2 Dranage wetted perimeter
P = x + 2Y = 2.2 m
3b.3 Hydraulic Radius
R = A/P = 0.254545454545 m

Solve for Qcap, 0.02


0.43
1 0.01
Qcap = x A x R2/3 x S½ (m³/s)
n

Qcap = 0.899687284343

Thus,
Qcap = 0.899687284343 > Qd = 0.370954060665 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04

50 3243.6 0.76 9.28


100 3595.52 0.76 9.59
Name of project :
ASSET PRESERVATION - CONSTRUCTION/ UPGRADING/ REHABILITATION OF DRAINAGE
ALONG NATIONAL ROADS TERTIARY ROADS - LANAO DEL NORTE INTERIOR CIRCUM. RD
(LDNICR) - K1548+000 - K1548+313, K1549+717 - K1550+331
Location : BALOI, LANAO DEL NORTE
Design Structure : AMRONZAMAN A. MACAMIMIS
Designed by : AMRONZAMAN A. MACAMIMIS

DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: Coef. width length
Catchment Area, CA = 0.025 km² 0.5 50 1000
Pavement Surface = 0.00558981 km² 0.9 6.7 927
Shoulder = 0.0005562 km² 0.3 2.0 927
total = 0.03114601 km²
Length of Main Watercourse, L = 1
Highest Elevation of drainage, He = 466.852
Elevation at the point of interest, El., = 418.286
Difference in Elevation, H = 48.566
Drainage Gradients, S = 0.01

2. DESIGN DISCHARGE CALCULATION:

Qd = ciA/3.6 (Rational Formula Method)


where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Drainage Area (total)
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff

CHARACTERISTICS RUNOFF COEFF.


a. Lawn, gardens meadows and cultivated lands 0.05-0.25
b. Suburban districts with few building 0.20-0.30
c. Residential district not densely built 0.30-0.55
d. Residential district densely built 0.50-0.75
e. For watershed having steep gullies and not heavily timbered 0.55-0.70
f. For watershed having moderate slope, cultivated and heavily timbered 0.45-0.55
g. For suburban areas 0.34-0.45
h. For agricultural areas 0.15-0.25

Hence, use 0.34 as runoff coefficient.

2b. Determine the rainfall intensity within the time of flood concentration, mm/hr

L1.15 (Kirpich Equation) time of concentration (mins)


tc =
51H -385

tc = 0.04935686116 mins

Therefore,
2090.54
i =
i =
(tc + 0.75 ) ^ 8.31 Rainfall intensity Duration curve, Return Period 5 yr.
tc
i = 248.4385858592 mm/hr 0.248438585859 m/hr.
Thus,
Qd = ciA/3.6 = 0.730798897514 m³/s

3. DESIGN DISCHARGE CAPACITY

Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness

3a. Manning's Coefficient of Roughness

CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. General waterway 0.03-0.035
b. Rapid river of wide and shallow river 0.04-0.05
c. Temporary waterway excavated without timbering 0.035
d. Three sided lined channel 0.025
e. River tunnel 0.023

Hence, use 0.025 as Roughness coefficient, n.

3b. DESIGN DIMENSIONS


x

D B
Y

X = 1
D = 0.7
B = 0.5
Y = 0.746

3b.1 Drainage cross-section area


A = ((B+X)/2)*D = 0.525 m²
3b.2 Dranage wetted perimeter
P = B + 2Y = 1.992 m
3b.3 Hydraulic Radius
R = A/P = 0.263554216867 m

Solve for Qcap, 0.02


0.46

Qcap = 1 x A x R2/3 x S½ (m³/s) 0.01


n
Qcap = 0.863242090139

Thus,
Qcap = 0.863242090139 > Qd = 0.730798897514 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
Name of project :
Location :
Design Structure :
Designed by :

DESIGN SHEET

REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: coef w L
Catchment Area, CA = 0.0975 km² 0.5 150 1300
Length of Main Watercourse, L = 0.8 km.
Highest Elevation of drainage, He = 101.15 m.
Elevation at the point of interest, El., = 99.8 m.
Difference in Elevation, H = 1.35 m.
Gradients, S = 0.01
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:

Qd = ciA/3.6 (Rational Formula Method)

where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff

CHARACTERISTICS RUNOFF COEFF.


a. Lawn, gardens meadows and cultivated lands 0.05-0.25
b. Suburban districts with few building 0.20-0.30
c. Residential district not densely built 0.30-0.55
d. Residential district densely built 0.50-0.75
e. For watershed having steep gullies and not heavily timbered 0.55-0.70
f. For watershed having moderate slope, cultivated and heavily timbered 0.45-0.55
g. For suburban areas 0.34-0.45
h. For agricultural areas 0.15-0.25

Hence, use 0.25 as runoff coefficient.

2b. Determine the rainfall intensity within the time of flood concentration, mm/hr

L1.15 (Kirpich Equation) time of concentration (mins)


tc =
51H -385

tc = 0.017027928182 mins
Therefore,
2464.1
i =
(tc ^ 0.76 + 8.76 )Rainfall intensity Duration curve, Return Period 10 yr.

i = 279.844197763 mm/hr 0.279844197763 m/hr.


Thus,
Qd = ciA/3.6 = 1.894778422353 m³/s

3. DESIGN DISCHARGE CAPACITY

Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness
3a. Manning's Coefficient of Roughness

CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. Concrete Box Culvert 0.017

Hence, use 0.017 as Roughness coefficient, n.

3b. DESIGN DIMENSIONS


B

Design Depth, D = 1.0


Design Width, B = 1.2

3b.1 Drainage cross-section area


A = BD = 1.2 m²
3b.2 Dranage wetted perimeter
P = B + 2D = 3.2 m
3b.3 Hydraulic Radius
R = A/P = 0.375 m
Solve for Qcap,

1
Qcap = x A x R2/3 x S½ (m³/s)
n
Qcap = 3.670736158327
Thus,
Qcap = 3.670736158327 > Qd = 1.894778422353 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
Name of project :
Location :
Design Structure :
Designed by :

DESIGN SHEET

REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA: coef w L
Drainage Area, CA (Waterway) = 0.0015 km² 0.5 6.00 500.00
(Lined Canal) = 0.027378 km² 0.9 25.35 1200.00
Total A = 0.028878 km²
Coefficient of Runoff C = 0.9
Rainfall Intensity from PAGASA I = 107.545 mm/hr
Length of Main Watercourse, L L = 500.00 m.
Highest Elevation of drainage, He H1 = 20.35 m.
Elevation at the point of interest, El., H2 = 16.50 m.
Difference in Elevation, H ΔH = 3.85 m.
Length of Box Culvert x = 12.00 m.
Width of Box Culvert w = 1.50 m.
Height of Box Culvert h = 1.50 m.
Manning's Roughness coefficient n = 0.017
Allowable Maximum Velocity Vmax = 5.000 m/s
Allowable Manimum Velocity Vmin = 0.500 m/s
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:

Qd = CIA/3.6 (Rational Formula Method)

where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff

CHARACTERISTICS RUNOFF COEFF.


a. Lawn, gardens meadows and cultivated lands 0.05-0.25
b. Suburban districts with few building 0.20-0.30
c. Residential district not densely built 0.30-0.55
d. Residential district densely built 0.50-0.75
e. For watershed having steep gullies and not heavily timbered 0.55-0.70
f. For watershed having moderate slope, cultivated and heavily timbered 0.45-0.55
g. For suburban areas 0.34-0.45
h. For agricultural areas 0.15-0.25

Hence, use 0.25 as runoff coefficient.


2b. Determine the rainfall intensity calculation
Time of Concentration (t)

L1.15 (Kirpich Equation) time of concentration (mins)


tc =
51H 0.385

tc = 41.84539866222 mins > 5 mins TRUE

Therefore,
2808.93
I =
(tc^ 0.76 ) + 9.04 Rainfall intensity Duration curve, Return Period 20 yr.

I = 107.545198902 mm/hr 0.107545198902 m/hr.

Thus,
Qd = ciA/3.6 = 0.776422563473 m³/s

add: Existing Q = 1.8 m³/s

Total Discharge = 2.576422563473 m³/s

3. DESIGN DISCHARGE CAPACITY

Qcap = AV

Qcap = Discharge Capacity of Box Culvert, m/s


V = Drainage Velocity, m³/s
A = Cross Section area of Box Culvert, m²

a) Cross-Sectional Area of Box Culvert

A = hxw
= 1.00 sq.m.

b) Discharge Velocity Calculations

1
V = R⅔ S½
n

where:
R = Hydraulic Radius of channel, m
S = Slope of Channel
n = Manning's Coefficient of Roughness

3a. Manning's Coefficient of Roughness


CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. Concrete Box Culvert 0.017

Hence, use 0.017 as Roughness coefficient, n.

3b. DESIGN DIMENSIONS


w

Design Depth, h = 1.00


Design Width, w = 1.00

3b.1 Drainage cross-section area


A = hw = 1.000 m²
3b.2 Dranage wetted perimeter
P = w + (2h*0.80) = 2.600 m
3b.3 Hydraulic Radius
R = A/P = 0.385 m
3b.4 Slope of Box Culvert
S = h/L = 0.0100
where: 0.01
h = 16.50 - 16.38 = 0.12
inlet outlet
therefore:(Discharge Velocity)

1
V = R⅔ S½
n
= 3.111016 m/sec < 5.0 m/sec SAFE

3c. Discharge Capacity of the Box Culvert

Qcap = AV

Qcap = 3.111015536367

3d. Design Freeboard required

Thus,
Qcap = 3.111015536367 > Qd = 2.576422563473 OK!!!
19.63164509

53.64895259

102.8641551
1270.03446 DIPOLOG (741)
24.90263648 YR FACTOR
1.074652529
2 1578.76 0.75 7.70
0.638630298 5 2090.54 0.75 8.31
15.90357816 10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
223.328 50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
6.993007

5.333333333
2.5198421 0.666667
0.5

2.774561219

2.774561219
Name of project :
Location :
Design Structure :
Designed by :

DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA:
Catchment Area, CA = 0.0014 km²
Length of Main Watercourse, L = 0.2
Highest Elevation of drainage, He = 101.15
Elevation at the point of interest, El., = 99.8
Difference in Elevation, H = 1.35
Gradients, S = 0.01
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:

Qd = ciA/3.6 (Rational Formula Method)

where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff

CHARACTERISTICS RUNOFF COEFF.


a. Lawn, gardens meadows and cultivated lands 0.05-0.25
b. Suburban districts with few building 0.20-0.30
c. Residential district not densely built 0.30-0.55
d. Residential district densely built 0.50-0.75
e. For watershed having steep gullies and not heavily timbered 0.55-0.70
f. For watershed having moderate slope, cultivated and heavily timbered 0.45-0.55
g. For suburban areas 0.34-0.45
h. For agricultural areas 0.15-0.25
Hence, use 0.25 as runoff coefficient.

2b. Determine the rainfall intensity within the time of flood concentration, mm/hr

L1.15 (Kirpich Equation) time of concentration (mins)


tc =
51H-385

tc = 0.096147503452 mins
Therefore,
2464.1
i =
(tc ^ 0.76 + 8.76 ) Rainfall intensity Duration curve, Return Period 10 yr.

i = 3242.23683685 mm/hr 3.24223683685 m/hr.


Thus,
Qd = ciA/3.6 = 0.315217470249 m³/s

3. DESIGN DISCHARGE CAPACITY

Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness

3a. Manning's Coefficient of Roughness

CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. Concrete Pipe Culvert 0.025

Hence, use 0.025 as Roughness coefficient, n.

3b. DESIGN DIMENSIONS

D = 0.61

Design Diameter, D = 0.61

3b.1 Drainage cross-section area


A = πD2/4 = 0.2922466566 m²
3b.2 Dranage wetted area
Aw = 0.765D2 = 0.2846565 m²
3b.3 Hydraulic Radius
R = 0.29D = 0.1769

Solve for Qcap,

1
Qcap = x Aw x R2/3 x S½ (m³/s)
n

Qcap = 0.358811470752

Thus,
Qcap = 0.358811470752 > Qd = 0.315217470249 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59
Name of project :
Location :
Design Structure :
Designed by :

DESIGN SHEET
REFERENCE:
1. Technical Standard and Guidelines for Planning and Design, Volume 1: Flood Control
1. DESIGN DATA:
Catchment Area, CA = 0.004 km²
Length of Main Watercourse, L = 0.5
Highest Elevation of drainage, He = 101.15
Elevation at the point of interest, El., = 99.8
Difference in Elevation, H = 1.35
Gradients, S = 0.01
PAGASA Rainfall Station = Dipolog City
2. DESIGN DISCHARGE CALCULATION:

Qd = ciA/3.6 (Rational Formula Method)

where;
Qd = Design Discharge, m3/s
c = Runoff Coefficient
I = Rainfall Intensity, mm/h
A = Catchment Area, km²
Note:
The Rational Formula Method is applicable to catchment area smaller than 20 km²
2a. Determine the coefficient of runoff

CHARACTERISTICS RUNOFF COEFF.


a. Lawn, gardens meadows and cultivated lands 0.05-0.25
b. Suburban districts with few building 0.20-0.30
c. Residential district not densely built 0.30-0.55
d. Residential district densely built 0.50-0.75
e. For watershed having steep gullies and not heavily timbered 0.55-0.70
f. For watershed having moderate slope, cultivated and heavily timbered 0.45-0.55
g. For suburban areas 0.34-0.45
h. For agricultural areas 0.15-0.25

Hence, use 0.25 as runoff coefficient.

2b. Determine the rainfall intensity within the time of flood concentration, mm/hr

L1.15 (Kirpich Equation) time of concentration (mins)


tc =
51H -385

tc = 0.14425336434 mins

Therefore,
2464.1
i =
(tc ^ 0.76 + 8.76 ) Rainfall intensity Duration curve, Return Period 10 yr.
i = 3242.236658462 mm/hr 3.242236658462 m/hr.
Thus,
Qd = ciA/3.6 = 0.900621294017 m³/s
add:
Existing Discharge = 0.1 m³/s

Total Discharge = 1.000621294017 m³/s

3. DESIGN DISCHARGE CAPACITY

Qcap = 1
n
Qcap = Discharge Capacity, m/s
V = Drainage Velocity, m³/s
A = Drainage Cross Section area, m²
R = Hydraulic Radius, m
S = Drainage Gradient/Slope
n = Manning's Coefficient of Roughness
3a. Manning's Coefficient of Roughness

CHARACTERISTICS
CHARACTERISTICS ROUGHNESS COEFF
a. Concrete Pipe Culvert 0.025

Hence, use 0.025 as Roughness coefficient, n.

3b. DESIGN DIMENSIONS

D = 0.91

Design Diameter, D = 0.91

3b.1 Drainage cross-section area


A = πD2/4 = 0.650388219109 m²
3b.2 Dranage wetted area
Aw = 0.765D2 = 0.6334965 m²
3b.3 Hydraulic Radius
R = 0.29D = 0.2639

Solve for Qcap,

1
Qcap = x Aw x R2/3 x S½ (m³/s)
n

Qcap = 1.042550588904
Thus,
Qcap = 1.042550588904 > Qd = 1.000621294017 OK!!!
DIPOLOG (741)
YR FACTOR
2 1578.76 0.75 7.70
5 2090.54 0.75 8.31
10 2464.1 0.76 8.76
20 2808.93 0.76 9.04
25 2927.64 0.76 9.16
50 3243.6 0.76 9.28
100 3595.52 0.76 9.59

You might also like