FAILURE ANALYSIS OF MULTI SECTION DIGITAL AXLE COUNTER Sr. No. 1. 2. 3. 4.

Diagnostic Event DP information DP information DP information DP information Message on MMI WLP ZPR 1+0+1 VERSTAZI(1) STA 01 011 DRW AS11,1 AS20,0 DFW 11 DFM 11 AR 11 AKT 00 REIH (1) NN 54724.54726 OK dfw OK da Explanation Wheel pulse longer than 3 seconds detected at DP n. Counting fault in DP n. Self test of analog circuits failed in DP n message received from SK1 Drift warning from DP n. CPU1 & 2 send a drift warning to rail contact SK1. Defect warning from DP n received from CPU1 & 2. Defect message from DP n received from CPU1 & 2. Restart of CPU1 & 2 in the detection point. Detection point n is not communicating. The ACE did not received the detection point telegram with the telegram no. 54725. The status of DP n is OK but a defect warning was sent. The status of DP n is OK but one of the rail contacts indicates a permanent wheel pulse. If no train is present, this indicates a faulty rail contact or analog board. The status of DP n is defect due to an unsuccessful self test. The status of DP n is defect due to loss of communication. The status of DP n is defect due to a defect message (dfm). Reset for section n cannot be carried out due to a technical defect. Conditional reset not carried out for section n because the last count was accounted into the section ( Section occupied). Reset not carried out for section n because section is already clear.

5. 6. 7. 8. 9.

DP information DP information DP information DP information DP information

10. 11.

STATE STATE

12. 13. 14. 15.

STATE STATE STATE Command

DEF st DEF komm DEF dfm Kdo abgew AZEGR ANFORD Grund TECHNISCH. Kdo abgew AZEGR ANFORD Grund Einschr = Einzaehlen bei BELEGET Kdo abgew AZEGR ANFORD Grund

16.

Command

17.

Command

Sr. No. 18.

Diagnostic Event Command

19. 20. 21. 22.

STATE STATE STATE STATE

Message on MMI BETRIEDLICH Kdo empf AZEGR ANFORD 01030000 OK fre OK bel DEF ges DEF def

Explanation

Conditional reset command for section n. Section n is clear Section n occupied Section n disturbed. A reset is possible. Section n disturbed due to a defect. Reset not possible.