Input Value Inputs Assumptions Hot water volume drawn in 24 hr Manufacturers rated tank size of water heater Water heater thermostat set point, minus 10 degrees F Inlet water temperature Ambient air temperature (around water heater) Heating element input capacity Warranty life (10 years or lifetime) EF of proposed model Is Tank Located Inside Heated Space? Constants: den Cp Avol Energy Use: Efficiency Options Existing Baseline 2004 Baseline Proposed Model Energy Savings of Proposed Model: Site Savings (kWh/yr)
Variable Name
55.4 50.0 120.0 55.0 72.0 4.5 10 0.93 Yes 8.29 1.00 0.00132 Yes
Hot Water Use Tanksz Ttank Tin Tamb Hin Warr EFprop
Density of water (at 96.5 degF) Specific heat of water (at 96.5 degF) EF adjustment factor for storage volume
EF
Calculated Energy Use Annual Use UA Btu/day kWh/year 0.86 3.921 34636 3705 0.90 2.456 33087 3539 0.93 1.570 32152 3439 Relative to 2004 Baseline 100