High Voltage Products


for cables, substations and
transmissions up to 800 kV
Catalogue 2008
1
Content
General 3
Cable Accessories up to 170 kV 4
Experience, Certicates, References
Terminations
Joints
Connection Boxes
Installation & Tools
Equipment for Substations up to 800 kV 46
Surge Arrester
High Voltage Connection System (HVCS)
Equipment for Transmission up to 500 kV 80
Tension Insulators
Hardware for Transmission Lines
Hardware for Distribution Lines
2
3
General
Energy Division
The Energy Division is a part of Tyco
Electronics. The headquarter of the
Energy Division is based in Ottobrunn,
near Munich in Germany. The world-
wide activities in the Energy Division
will be handled from here. Besides
modern laboratories for Research and
Development the production of heat
shrink tubings is placed here also the
logistic centre for shipments into the
whole world.
In other countries like United King-
dom and France we have factories for
producing the products which will be
shown in this catalogue.
Quality and Environment
Quality
The Tyco Electronics factories are
certied to ISO 9000. Our vendor
routine tests and internal incoming
inspection conrm performance of
all critical components used in the
assembly of our products. We offer
competitive lead times on all standard
products.
Environment
The Tyco Electronics factories are
also certied to ISO 14001. The gentle
exposure with natural resources for
our products and processes is for us
one of the important aspects.
Packaging
We try to minimize the packaging
materials, without any danger for the
products. All packaging materials can
be disposed without any problems.
Recycling
The most waste of the different
locations will be recycled. If possible
this will be done at the location or
the waste will be repatriate to the
economic cycle in another kind.
Production Processes
Our production processes are ar-
ranged to minimize the inuence of
the environment. Hereby is the focus
on an optimal Energy usage one of
the main aspects. With special proce-
dures we use the dispensed warmness
from the production machinery to
heat the production halls.
Water
We could reduce the usage of water
by concurrent rising of the production
volume.
Waste
We could reduce the amount of waste
by concurrent rising of the production
volume.
Test Procedure and
Qualication
Tyco Electronics products are tested
and certied to the major national
and international standards, e. g. IEC,
CENELEC, VDE, GOST, BS, etc.
Germany
France
United Kingdom
4
C
a
b
l
e

A
c
c
e
s
s
o
r
i
e
s
5
Cable Accessories
Experience, Certicates, References 6
Terminations 8
Joints 24
Connection Boxes 32
Installation & Tools 38
6
Experience
Tyco Electronics Raychem GmbH is
one of the World leaders on cable
accessories production for voltages
up to 170 kV.
Our company is focused on develop-
ment, manufacturing of cable ac-
cessories and execution of projects
providing reliable operation of electric
power systems.
Application of Tyco Electronics
Raychem GmbH cable accessories
provides the increase of customers
protability and competitive capacity
due to high operational performance
of our products.
Many worlds leading enterprises
apply our cable accessories which
are developed for the long-term
operation in most severe conditions
of indoor and outdoor maintenance in
any climatic zones and high pollution
locations. Our products have a very
high reliability index which warrants
saving of customers capital outlays.
We use an experience accumulated
within more than 40 years in sphere
of materials science, development of
new technologies and intensive study
of customers needs.
We constantly improve production
technology and quality of our prod-
ucts paying attention to customers
increasing requests.
Our products passed all relevant tests
in independent test labs in order
to comply with quality requests of
International Standards like IEC, IEEE.
Tyco Electronics Raychem GmbH of-
fers a wide range of cable accessories.
In this catalogue we present the range
from 42 kV up to 170 kV:
Outdoor / Indoor Terminations
Switchgear terminations and
transformer terminations with
Corona Shield
Joints for plastic insulated cables
Inline or shield-break type joints
Tyco Electronics Raychem GmbH
has technical support centers where
customers can get professional assist-
ance. Our specialists are always ready
to nd solutions for any specic issue
of every enterprise.
Certicates
ISO 9000 series and ISO 14001
certications for almost all locations
underline our continuing commitment
to quality and the environment. The
products are subjected to extensive
testing from the time they enter our
plants as raw material until they leave
as nished products.
Requalication testing is carried
out on a regular basis with installed
components.
7
References
Our company has realized thousands
of projects all over the World includ-
ing tropical zones, deserts, places
behind polar circle and in high pollu-
tion industrial and coastal areas.
List of countries where our company
executed projects with HV cable ac-
cessories increases every month and
some of them are listed below:
Australia Korea
Austria Lithuania
Belgium Luxemburg
Brazil Netherlands
Canada Norway
China Peru
Colombia Philippines
Croatia Portugal
Denmark Russia
Egypt Saudi Arabia
Finland Singapore
France Slovenia
Germany Spain
Greece Sweden
Hong-Kong Taiwan
India Thailand
Indonesia Ukraine
Iran United Arabic Emirates
Ireland United Kingdom
Kenya USA
Detailed list of projects quantity in
each country and names of custom-
ers can be presented upon additional
inquiry.
8
T
e
r
m
i
n
a
t
i
o
n
s
9
Terminations from 42 kV up to 72 kV
Application, Features 10
Indoor Terminations 11
Outdoor Terminations 11
Terminations with long creepage 11
Lugs for Terminations 12
Terminations up to 170 kV

Outdoor, Composite, Dry plug-in 14
Outdoor, Composite, Oil-lled 16
Connectors for Outdoor Terminations 18
Switchgear & Transformer, Dry plug-in 20
Switchgear & Transformer, Oil-lled 22
10
Termination Systems for Polymeric Insulated Cables up to 72 kV
Application
Raychems terminations up to 72 kV
are suitable for all climates and
environments, even severely polluted
areas, and for all installation condi-
tions, including top feed installation.
The factory-engineered kits contain
a proven termination system which
saves space, facilitates installation and
enhances system reliability. The spe-
cial design of the termination, which
incorporates pre-coated tracking
resistant sealants that melt during the
shrinking process, results in a reliable
and lasting barrier against moisture
and corrosion.
Features
The slim, compound-free Raychem
Terminations are suitable for indoor
and outdoor use on all polymeric
cables for voltages from 42 kV up to
72 kV.
Easy installation
Non-tracking, heat-shrinkable outer
insulation
Heat-shrinkable stress control
sleeves
Pre-coated track resistant sealant
Water and corrosion resistant
Light-weight components
Isolated base plate for
sectionalisation
High reliability
11
Major Design Elements
Kit content:
The kit contains a limited number
of light-weight components with
unlimited shelf life under normal stor-
age conditions. The heat-shrinkable
sleeves are extremely versatile, and
accommodate a wide range of cable
diameters. Four basic kits cover all
cable sizes, permitting reduced inven-
tories and efcient stocking policy.
The lightweight of the components
and limited volume of the kits facili-
tate safe and easy transportation and
handling. All components are included
in a single box.
The set of pre-engineered compo-
nents requires no special or expensive
tools for installation. Installation
involves a simple set of standard
procedures with no soldering re-
quired. Neither does the termination
require lling with oil or compound.
Risk of leakage is avoided, and lling
and topping-up time on the job site is
saved.
High Performance Material:
Raychem terminations are made of
a specially formulated material with
excellent tracking and erosion resist-
ance characteristics. Accelerated and
natural weathering tests which have
been carried out at Raychem facilities
and independent test sites around
the world have demonstrated that
the terminations are UV and water
resistant and perform reliably even
when exposed to sudden temperature
variations. A Tracking and Erosion
Test as per ASTM D2303 showed no
tracking. IEC 112 was also conducted
with no erosion or tracking observed.
Electrical Stress Control:
Screened or shielded power cables
require electrical stress control in
order to reduce the electrical stresses
at the end of the screen and at the
termination surface to avoid partial
discharge and surface corona under
all service conditions. Corona or
electrical discharge can ultimately
destroy the cable insulation, causing
premature failure.
Raychems stress control sleeves have
electrical properties that smooth out
the electrical eld at the end of the
cable. This is achieved by the unique
resistive and capacitive properties of
the heat-shrinkable materials.
A Universal System:
The material used in these termina-
tions is suitable for all climates and
environments. It is not susceptible
to damage from transportation or
vandalism. The termination has a
discreet, low prole which allows it to
blend into landscapes.
42 kV 52 kV 72 kV
Indoor b b b b b
Outdoor b b b b b
Long Creepage b b
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e

o
r

l
e
a
d

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e

o
r

l
e
a
d

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e

o
r

l
e
a
d

s
h
i
e
l
d
Outdoor Indoor
Controlled torque lug
Non-tracking
heat-shrinkable
outer insulation
Heat-shrinkable sheds
Heat-shrinkable
stress-control sleeves
Stress-relief material
Solderless
grounding accessory
High-voltage sealant
12
Torque Controlled Lugs for Termination Systems up to 72 kV
Features
Torque controlled shear off bolts
Application Range
Lugs
Benets
fast and safe installation
excellent electrical performance
excellent mechanical performance
easy installation with standard box
spanner
pre-engineered design for perfect t
Cu and Al conductors
up to 1200 mm
2
Variety of different palms available
Body made of tinned aluminium
alloy
13
Cable lug with 1-hole palm
(EPPA-052-X/Y)
Cable lug with 2-hole palm
(EPPA-051-X/Y)
Cable lug with rod
Cable lug with 4-hole palm (NEMA pad)
(EPPA-054-X/Y)
X Diameter over cable conductor
Y Diameter over cable insulation
X Diameter over cable conductor
Y Diameter over cable insulation
X Diameter over cable conductor
Y Diameter over cable insulation
X Diameter over cable conductor
Y Diameter over cable insulation
Dimension:
L = 190 mm D = 18 mm
A = 100 mm E = 25 mm
B = 50 mm F = 64 mm
Dimension:
L = 190 mm D = 18 mm
A = 100 mm E = 25 mm
B = 27.5 mm F = 64 mm
C = 45 mm
Dimension:
Rod 30 mm (EPPA-050-X/Y)
L = 190 mm A = 100 mm
F = 64 mm = 30 mm
Rod 40 mm (EPPA-053-X/Y)
L = 264 mm A = 125 mm
F = 106 mm = 40 mm
Rod 50 mm (EPPA-061-X/Y)
L = 264 mm A = 125 mm
F = 106 mm = 50 mm
Dimension:
Contact plate 100 mm x 100 mm
L = 232 mm D = 14.5 mm
A = 100 mm E = 25 mm
B = 27.5 mm F = 112 mm
C = 45 mm
Contact plate 80 mm x 80 mm
L = 212 mm D = 14.5 mm
A = 80 mm E = 25 mm
B = 17.5 mm F = 112 mm
C = 45 mm
14
Dry Self-Supporting Outdoor Termination OHVT up to 145 kV
Application
The dry self-supporting termination
is designed for voltage classes up to
145 kV and operation under severe
environmental conditions. It is free
from any insulating liquid or gel.
Polymeric insulated cables of various
designs can be adopted with respect
to shielding and metal sheath. The
polymeric housing with long creepage
length covers extreme pollution levels
according to IEC 60071-1 1996, IEC
60071-2 1996 and IEEE-1313.1-1996.
Its mechanical performance is similar
to conventional oil-lled terminations
with composite housing.
The termination is easily separable
and consists of a plug-in part and an
epoxy resin insulator protected with
directly moulded silicone shed hous-
ing. Due to the short cable cutback
dimensions of the plug-in the time
required to install the termination is
very short and can be further reduced
in case of short cable links by pre-in-
stalling the plug-in on the shop oor.
The plug-in is similar to the plug-in
used with Tycos dry switchgear/
transformer termination.

Features
Dry interface, no oil-lling
Self-supporting
Pre-fabricated and factory tested
silicone rubber stress control
Torque-controlled multi-contact
conductor bolt
Fast and simple installation combin-
ing GIS plug-in technology with
polymeric insulators
No special tools required to install
the termination
Isolated cable gland for sectionali-
sation
Long creepage length
Type tested according to IEC 60840
OHVT-145D
Highest Voltage U
M
kV 145
Lightning Impulse Voltage kV 650
Length mm 1750
Cantilever Force N 5000
Flashover Distance mm 1320
Creepage Distance mm 4495
Pollution Level (IEC 60 137; 1995, VDE 0674, part 5) IV
Weight approx. kg 130
Max. Conductor Size Cu/Al approx. mm
2
1200
Outer Diameter Cable Insulation mm 74
Outer Diameter Cable Oversheath mm 99
Technical Data
15
Major Design Elements
The polymeric insulator (3) with
embedded multi-contact electrode
is attached to the support structure
through the base plate (6) and the
support insulators (7).
The torque-controlled shear-off bolt
connector (2) with multi contacts ts
the cable conductor. The connector
is suitable for stranded aluminium
and copper conductors and can be
modied to accept solid conductors
as well. No special tool is required to
install the connector.
The silicone rubber stress cone (4)
provides the electrical eld control
and can easily be applied on the cable
without tools owing to its excellent
elasticity.
A metal spring-loaded compression
ring (5) presses the rubber stress
cone into the specially shaped interior
of the insulator housing, ensuring a
uniform contact pressure and electri-
cally sound interface.
The cable outer serving is adapted
through a gland system (8), which
addresses the individual shielding and
armouring. The gland system also
secures the cable.
1 Upper metal tting
2 Mechanical connector
3 Resin body with silicone shed
housing
4 Stress cone
5 Spring-loaded compression ring
6 Base plate
7 Support insulators
8 Gland and sealing
1
2
3
4
5
6
7
8
16
Outdoor Composite Termination OHVT for 123 kV up to 170 kV
Application
The termination is designed for
voltage classes up to 170 kV and to
operate under severe environmental
conditions. Polymeric insulated
cables of various designs can be
adopted with respect to shielding and
metal sheath. Composite housings
with different creepage lengths up
to 50 mm/kV are available covering
the most common and also extreme
pollution levels according to
IEC 60071-1 1996, IEC 60071-2 1996
and IEEE-1313.1 1996.
Features
Pressure-tight and light weight
composite housing
Pre-fabricated and factory tested
Si-rubber stress cone
Torque-controlled conductor bolt
H/S components used for sealing
No special tools required to install
the termination
Si-oil lling (lling from the top)
Isolated base plate for sectionali-
sation
Fittings made of corrosion resistant
alloy
Type tested according to IEC 60840
and IEEE 48 standards
OHVT-145 OHVT-170
Highest Voltage U
M
kV 145 170
Lightning Impulse Voltage kV 650 750
Length mm 1880 2100
Diameter over sheds mm 294 355
Cantilever Force N 5000 5000
Flashover Distance mm on demand on demand
Creepage Distance mm on demand on demand
Pollution Level (IEC 60 137; 1995, VDE 0674, part 5) II IV
Oil volume approx. l 35 50
Weight approx. kg 120 160
Max. Conductor Size Cu/Al approx. mm
2
1200 1200
Outer Diameter Cable Insulation mm 90 108
Outer Diameter Cable Oversheath mm 110 119
Technical Data
17
Major Design Elements
The pressure-tight composite housing
(4) is made of a glass bre reinforced
resin GFR tube with silicone rubber
sheds moulded INSITU to the tube.
The ttings (3) and the base plate (7)
are made of non-corrosive alloy.
To t the cable conductor, mechanical
connectors with torque-controlled
shear-off bolts (1) or crimp-type
connectors are available. The connec-
tor is suitable for stranded aluminium
and copper conductors and can be
modied to accept solid conductors
as well. No special tool is required
to install the mechanical connector.
Heat-shrinkable polymeric tubing
containing oil-resistant sealant encap-
sulates the connector barrel and the
polymeric insulation transition.
The silicone rubber stress cone (6)
provides the electrical eld control
and can easily be applied without
tools owing to its excellent elasticity.
The interface between stress cone,
cable insulation and inner GFR hous-
ing is lled with silicone oil (5) which
could be easily lled from the top.
The cable outer serving is adapted
through a gland system (9), which
addresses the individual shielding and
armouring of the cable. Heat shrink-
able tubing is used to seal the cable
gland.
Support insulators (8) are supplied for
sectionalisation and cross-bonding,
when separate grounding is required.
1 Connector (mechanical or crimp)
2 Sealing system
3 Upper Metal tting
4 Composite housing
5 Oil-lling
6 Stress cone
7 Base plate
8 Support insulators
9 Gland and sealing
1
2
3
4
5
6
7
8
9
18
D
D
L
B
C
16
44,4 100
27,8 44,4
100
14,3
D1
C1 C2
D2
L
D1 B1 D2 B2
D
C C
D
D B D
L
Connectors for Outdoor Terminations up to 145 kV
Description D B C L Reference
ROD 30 2631 29 85 193 SIML-0-0707021-1
ROD 40 3641 32 92 200 SIML-0-0707121-1
ROD 50 4651 25 94 207 SIML-0-0718671-1
Dimensions in mm
Terminal Pad (NEMA)
Straight Rod
Description D1 D2 B1 B2 C1 C2 L Reference
ROD 30/20 2631 1621 84 66 85 70 165 SIML-0-0706684-1
ROD 30/25 2631 2126 84 66 85 70 165 SIML-0-0706636-1
ROD 30/35 2631 3136 84 84 85 85 180 SIML-0-0706949-1
ROD 40/20 3641 1621 102 66 92 70 172 SIML-0-0706700-1
ROD 40/25 3641 2126 102 66 92 70 172 SIML-0-0706635-1
ROD 40/30 3641 2631 102 84 92 85 187 SIML-0-0706655-1
ROD 40/35 3641 3136 102 84 92 85 187 SIML-0-0706663-1
ROD 50/20 4651 1621 112 66 92 70 174 SIML-0-0712016-1
ROD 50/25 4651 2126 112 66 92 70 174 SIML-0-0716341-1
ROD 50/30 4651 2631 112 84 92 85 189 SIML-0-0711000-1
ROD 50/35 4651 3136 112 84 92 85 189 SIML-0-0711002-1
ROD 50/40 4651 3641 112 102 92 92 196 SIML-0-0711001-1
Dimensions in mm
Straight Transition Rod
Description D B C L Reference
ROD 30 2631 84 85 180 SIML-0-0706684-1
ROD 40 3641 92 102 195 SIML-0-0706685-1
Dimensions in mm
19
C1
C2
D2 D1
D1
D2 B2 B1
L
B1
B2
D2 D2 D2
C2
C1
L
D1
D1
B3
B
C1
C2
D1
D2 D2
C3
C4
D2
L1
L2
D1
T-Rod
Twin Straight Rod
Description D1 D2 B C1 C2 C3 C4 L1 L2 Reference
TWIN T ROD
50/30
4651 3641 100 136 94 134 84 185 171 SIML-0-0706684-1
TWIN T ROD
50/35
4651 3136 100 136 94 134 84 185 171 SIML-0-0706636-1
TWIN T ROD
50/40
4651 3641 105 145 94 145 92 186 195 SIML-0-0706949-1
Dimensions in mm
Twin T-Rod
Description D1 D2 B1 B2 C1 C2 L Reference
T-ROD 30/20 2631 1621 84 66 124 70 166 SIML-0-0716192-1
T-ROD 30/25 2631 2126 84 66 124 70 166 SIML-0-0706686-1
T-ROD 30/30 2631 2631 84 84 140 85 182 SIML-0-0706627-1
T-ROD 30/35 2631 3136 84 84 140 85 182 SIML-0-0706638-1
T-ROD 30/40 2631 3641 84 102 143 92 195 SIML-0-0706667-1
T-ROD 40/20 3641 1621 92 66 131 70 182 SIML-0-0716198-1
T-ROD 40/25 3641 2126 92 66 131 70 182 SIML-0-0716106-1
T-ROD 40/30 3641 2631 92 84 146 85 197 SIML-0-0706624-1
T-ROD 40/35 3641 3136 92 84 146 85 207 SIML-0-0706623-1
T-ROD 40/40 3641 3641 92 102 151 92 207 SIML-0-0706622-1
T-ROD 50/20 4651 1621 94 66 135 70 191 SIML-0-0716203-1
T-ROD 50/25 4651 2126 94 66 135 70 191 SIML-0-0716342-1
T-ROD 50/30 4651 2631 94 84 151 85 207 SIML-0-0716342-1
T-ROD 50/35 4651 3136 94 84 151 85 207 SIML-0-0716204-1
T-ROD 50/40 4651 3641 94 102 158 92 214 SIML-0-0706664-1
Dimensions in mm
Description D1 D2 B1 B2 B3 C1 C2 L Reference
TWIN STRAIGHT
ROD 50/30
4651 3641 184 100 112 94 85 214 SIML-0-0716192-1
TWIN STRAIGHT
ROD 50/35
4651 3136 184 100 122 94 85 214 SIML-0-0706686-1
TWIN STRAIGHT
ROD 50/40
4651 3641 207 105 112 94 85 230 SIML-0-0706627-1
Dimensions in mm
20
Dry Compact Switchgear & Transformer Termination PHVS & PHVT
from 72 kV up to 145 kV
Application
The dry compact switchgear termina-
tion for voltage classes up to 145 kV is
designed to be installed in cable entry
housings of gas-insulated switchgear
(GIS). It complies with IEC 62271-209
standard, which essentially species
the interfaces between the termina-
tion and the switchgear.
Therefore the termination will t into
all GIS complying with IEC 62271-209.
An adapter is available to match the
dimensions of wet (oil-lled) type
terminations, which are also specied
in IEC 62271-209.
The termination operates in SF
6
but
also in insulating liquids like trans-
former oil. A corona shield at the top
of the termination then provides the
necessary shielding of the terminal.
The termination is easily separable
and consists of a plug-in part and an
epoxy resin insulator. The insulator
can be installed by the GIS or trans-
former manufacturer already at the
factory saving installation time onsite
and reducing the risk of contamina-
tion of the cable entry housing. In
case of short cable links and due to
the short length and light weight of
the plug-in part it can be also pre-
installed by the cable manufacturer
further reducing the time required to
install a substation.
Features
Dry interfaces, no oil-lling
Dimensions comply with
IEC 62271-209
Pressure-tight resin housing
Operates in SF
6
and insulating
liquids
Pre-fabricated and factory tested
Si-rubber stress cone
Torque-controlled multi-contact
conductor bolt
No special tools required to install
the termination
Isolated cable gland for sectionali-
sation
Type tested according to IEC 60840
and IEC 62271-209 standards
PHVS-145 PHVT-145
Highest Voltage U
M
kV 145 145
Lightning Impulse Voltage kV 650 650
Length (with IEC Adapter) mm 470 (757) 470 (757)
Weight approx. (with IEC Adapter) kg 38 (42) 38 (42)
Operating Pressure SF
6
bar 26
Max. Conductor Size Cu/Al approx.
(optional) mm
2
800
(1200)
800
(1200)
Outer Diameter Cable Insulation mm 74 74
Outer Diameter Cable Oversheath mm 99 99
Technical Data
21
62271-209)
62271-209)
1
2
4
5
6
7
8
3
Major Design Elements
The epoxy-resin insulator (4) with
embedded multi-contact electrode
forms the gas pressure-tight interface
between GIS or transformer cable
entry and the plug-in part of the
termination. It is attached to the cable
entry housing with the xing ring (7).
The torque-controlled shear-off bolt
connector (3) with multi-contacts ts
the cable conductor. The connector
is suitable for stranded aluminium
and copper conductors and can be
modied to accept solid conductors
as well. No special tool is required to
install the connector.
The silicone rubber stress cone (5)
provides the electrical eld control
and can easily be applied without
tools owing to its excellent elasticity.
A metal spring-loaded compression
ring (6) presses the rubber stress
cone into the specially shaped interior
of the resin housing, ensuring a uni-
form contact pressure and electrically
sound interface.
A corona shield (1) can be easily
attached to the termination for use
in insulating liquids. Compared with
IEC 60859 wider clearances apply in
this application.
The cable outer serving is adapted
through a gland system (8), which
addresses the individual shielding and
armouring. The gland system also
secures the cable.
An adapter (2) can be used to match
the dimensions of wet type switch-
gear and transformer terminations
which makes the termination an ideal
choice for replacing oil-lled termina-
tions.
1 Corona Shield
2 Adapter (optional)
3 Connector (mechanical)
4 Resin housing
5 Stress cone
6 Spring-loaded compression ring
7 Fixing ring
8 Gland and sealing
22
Application
The switchgear termination for volt-
age classes up to 170 kV is designed
to be installed in cable entry housings
of gas-insulated switchgear (GIS).
It complies with IEC 62271-209 and
IEEE 1300 standards, which essen-
tially specify the interfaces between
the termination and the switchgear.
Therefore the termination will t into
all GIS complying with these stand-
ards.
The termination operates in SF
6
but
also in insulating liquids like trans-
former oil. A corona shield at the top
of the termination then provides the
necessary shielding of the terminal.
Features
Si-oil lling (no need for heating
before lling)
Dimensions comply with
IEC 62271-209 and IEEE 1300
Pressure-tight resin housing
Operates in SF
6
and insulating
liquids
Pre-fabricated and factory tested
Si-rubber stress cone
Torque-controlled conductor bolt
No special tools required to install
the termination
Isolated cable gland for sectionali-
sation
Type tested according to IEC 60840,
IEC 62271-209 and IEEE 1300
standards
SHVT-170 THVT-170
Highest Voltage U
M
kV 170 170
Lightning Impulse Voltage kV 750 750
Length mm 757 757
Cantilever Force N 6500 6500
Creepage Distance mm 650 650
Oil volume approx. l 12 12
Weight approx. kg 92 92
Operating Pressure SF
6
bar 26
Max. Conductor Size Cu/Al approx. mm
2
1200 1200
Outer Diameter Cable Insulation mm 84 84
Outer Diameter Cable Oversheath mm 105 105
Technical Data
Switchgear & Transformer Termination SHVT & THVT for 72 kV up to 170 kV
23
62271-209)
62271-209)
1
2
4
5
6
7
8
3
Major Design Elements
The epoxy-resin insulator (3) with
embedded electrode forms the gas
pressure-tight interface between GIS
or transformer cable entry and the
oil-lled cable compartment of the
termination. It is attached to the cable
entry housing with the xing ring (6).
To t the cable conductor, torque-
controlled shear-off bolt connector
(2) or crimp-type connectors are
available. The connector is suitable
for stranded aluminium and copper
conductors and can be modied to
accept solid conductors as well. No
special tool is required to install the
mechanical connector. The exible
double sealing system is installer-
friendly and ensures persistent leak
tightness of the top assembly. Heat
shrinkable polymeric tubing contain-
ing oil-resistant sealant encapsulates
the connector barrel and the poly-
meric insulation transition.
The silicone rubber stress cone (5)
provides the electrical eld control
and can easily be applied without
tools owing to its excellent elasticity.
The interface between stress cone,
cable insulation and inner GFR
housing is lled with silicone oil (4)
through a lling nozzle at the base
plate.
The cable outer serving is adapted
through a gland system (8), which
addresses the individual shielding and
armouring of the cable. Heat shrink-
able tubing is used to seal the cable
gland.
1 Corona shield (THVT only)
2 Connector (mechanical or crimp)
3 Resin housing
4 Oil-lling
5 Stress cone
6 Fixing ring
7 Base Plate
8 Gland and sealing
24
J
o
i
n
t
s
25
Joints from 42 kV up to 72 kV
Application, Features 26
Connectors for Joints 29
Joints up to 170 kV
Inline and Shield-Break Joints 30
26
Application
The elastomeric Raychem joints from
42 kV up to 72 kV are suitable for
all type of polymeric cables and can
accommodate various cross-bonding
shield break and external grounding
arrangements.
Features
Quick cable preparation.
Simplied installation:
No specialists required. A qualied
medium-voltage jointer will be
trained in one day.
Pre-engineered wall thickness:
All product dimensions are set and
checked at the factory before the
product is shipped to the eld.
Time savings:
Due to short installation time out-
ages are kept to a minimum in repair
situations.
High reliability:
The combination of long experience
and rigorous testing to international
standards leads to high joint reli-
ability.
Joints for Polymeric Insulated Cables EHVS from 42 kV up to 72 kV
27
Major Design Elements
Designed for easy jointing:
The Raychem joint design comprises
of a connector that allows even large
cross-sections to be jointed and two
dual-wall, heat-shrinkable sleeves.
A heavy-walled co-extrusion of two
layers of red insulation forms the inner
sleeve. The outer sleeve consists of a
thick layer of red insulation co-extrud-
ed under a black outer conductive
layer which acts as the joint screen.
Kit Content:
The set of pre-engineered compo-
nents and the Raychem connector
require no special installation tools.
After placing the heat-shrinkable
components over the cable end, the
connector is installed by tightening
the special bolts, which shear off
cleanly when the correct contact
force is reached. Each sleeve in turn
is placed over the connector area and
shrunk down. Copper shielding mesh
and an adhesive-coated outer sleeve
for water sealing then complete the
joint.
Controlled-torque Connector:
The connector design allows cables
to be jointed without special tools,
heat treatment as dressing/ling after
installation. Shear-head bolts ensure a
pre-engineered electrical connection.
The shear-head bolts break off at a
pre-determined level below the outer
surface of the connector, at a dened
torque. This ensures the correct con-
tact pressure is reached every time.
The stable voltage drop provided by
this concept has been demonstrated
in eld installations which closely
follow the predictions of long-term
load-cycling tests.
Comprehensive qualication proce-
dures like IEC 61238-1996 and ANSI
119.4 1993 prove the excellent long-
term performance.
28
Electrical Stress Control:
A material with stress adjusting
characteristics is applied onto the
connector and cable screen ends. This
heat-shrinkable sleeve incorporates a
conductive coating in the connector
area which equalizes potential in the
manner of a Faraday cage. It extends
over the dielectric to accommodate
possible insulation shrink-back.
Cross-bonding / shield break:
The use of heat-shrinkable sleeves for
stress control, insulation, and screen-
ing provides a location for the shield
break at the end of the joint.
Outer Sealing:
The cable oversheath is replaced with
a thick-wall heat-shrinkable insulating
sleeve, which provides the required
dielectric strength and create an
effective water seal and corrosion
protection.
Elastomeric Technology:
Two dual-wall, heatshrinkable elas-
tomeric sleeves shrink rapidly and
deliver pre-engineered, uniform layers
of thick insulation. The outer layer
shrink to the pre-determined diam-
eter and the elastomeric inner part
conrms tightly to the joint.
42 kV 52 kV 72 kV
Joints b b b b b b b
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e
o
r

l
e
a
d

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d

a
n
d

c
r
o
s
s

b
o
n
d
i
n
g

m
o
d
u
l
e
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e

o
r

l
e
a
d

s
h
i
e
l
d

a
n
d

c
r
o
s
s

b
o
n
d
i
n
g

m
o
d
u
l
e
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e
o
r

l
e
a
d

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d

a
n
d

c
r
o
s
s

b
o
n
d
i
n
g

m
o
d
u
l
e
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e

o
r

l
e
a
d

s
h
i
e
l
d

a
n
d

c
r
o
s
s

b
o
n
d
i
n
g

m
o
d
u
l
e
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e
o
r

l
e
a
d

s
h
i
e
l
d
C
a
b
l
e

w
i
t
h

w
i
r
e

s
h
i
e
l
d

a
n
d

c
r
o
s
s

b
o
n
d
i
n
g

m
o
d
u
l
e
C
a
b
l
e

w
i
t
h

m
e
t
a
l

t
a
p
e

o
r

l
e
a
d

s
h
i
e
l
d

a
n
d

c
r
o
s
s

b
o
n
d
i
n
g

m
o
d
u
l
e
29
Torque Controlled Connectors for Joints up to 72 kV
Features
Torque controlled shear off bolts
fast and safe installation
excellent electrical performance
excellent mechanical performance
easy installation with standard box
spanner
Application Range
pre-engineered design for perfect t
Cu and Al conductors
Up to 1200 mm
2
Connectors
Straight and size transition type
Body made of aluminium alloy
Mechanical connector for straight
connection
X Diameter over cable conductor
Y Diameter over cable insulation
Dimension:
L = 130 mm
L = 180 mm
(EPPA-047-X/Y-L)
Mechanical connector for size
transition
X1/X2 Diameter over cable conductor
Y1/Y2 Diameter over cable insulation
Dimension:
L = 130 mm
L = 180 mm
(EPPA-047-X1/Y1-X2/Y2-L)
Mechanical connector for cables
with small insulation thickness
X1/X2 Diameter over cable conductor
Y1/Y2 Diameter over cable insulation
Dimension:
L = 180 mm
L = 230 mm
(EPPA-063-X1/Y1-X2/Y2-L)
30
Application
The joint is a pre-fabricated three-
piece design for voltages from 123 kV
up to 170 kV. Polymeric insulated
cables of various designs can be
adopted with respect to shielding and
metal sheath.
Features
Pre-fabricated three-piece joint
design
Torque-controlled conductor sleeves
Integrated moisture barrier using
H/S components
Short cut-back dimensions
No special tools required to install
the joint
Can adapt shield-break applications
Cable size transition is possible
Factory tested Si-rubber parts
Type tested according to IEC 60840
and IEEE 404 standards
EHVS-145-IL EHVS-170-IL EHVS-145-SB EHVS-170-SB
Highest Voltage U
M
kV 145 170 145 170
Lightning Impulse Voltage kV 650 750 650 750
Length mm 1500 1900 2000 2400
Diameter mm 195 240 195 245
Weight approx. kg 40 60 45 75
Max. Conductor Size Cu/Al approx. mm
2
1200 1200 1200 1200
Outer Diameter Cable Insulation mm 75 84 75 108
Outer Diameter Cable Oversheath mm 105 105 105 140
IL: Inline Joint
SB: Shield Break Joint
Technical Data
Inline and Shield-Break Joint EHVS for 123 kV up to 170 kV
31
2
3
9
11
12
4
Major Design Elements
The joint consists of connector (1),
cable adapters (2) including stress
cones and main joint body (3) con-
taining Faraday cage (7) and outer
serving by heat-shrink technology
(9,12). The conductors of the cable are
connected by a mechanical connec-
tor sleeve (1) using torque controlled
shear-off bolts. The connector sleeve
is suitable for stranded aluminium and
copper conductors but can be easily
modied to accept solid conductors
as well. The Si-rubber cable adapters
(2), accommodating the various cable
insulation diameters, build up the
connection area to an almost constant
diameter. This allows to cover dif-
ferent cable cross-sections with just
one main insulation joint body (3).
Therefore cross-section transitions are
possible without any extra compo-
nents.
No extra tooling is needed to push-on
the Si-rubber cable adapters (2) and
the Si-rubber joint main body (3) due
to its excellent elasticity.
A metal shielding clamp (7) on top of
the connector ensures perfect heat
transmission and a smooth interface
t. The xing rings (6) keep the cable
adapter and the cable dielectric in
position.
During the installation the main body
is parked on the over sheath of the
cable. This keeps the cut back length
and cable preparation time as short as
possible. Mechanical solderless con-
nector technologies (8) are used to
connect metal shields copper wires,
metal sheath and CAS. Heat-shrink
technologies (9,12) replace the cable
serving and the moisture barrier.
The joint concept is similar for the
shield break joints, despite the shield
continuity.
Special sealant components make it
possible to use double-insulated
ground leads, and thereby to utilise
the proven heat-shrink technology.
1 Mechanical connector
2 Adapter
3 Main body
4 Stress cone
5 HV electrode
6 Fixing ring
7 Metal shielding clamp
8 Solderless shield connection
9 Conductive tubing
10 Copper mesh
11 Insulating tubing
12 Outer protection with integrated
moisture barrier
EHVS-IL (Inline Joint) EHVS-SB (Shield Break Joint)
5
6
1
7
10
2
3
9
11
12
4
5
6
1
7
10
8
32
C
o
n
n
e
c
t
i
o
n

B
o
x
e
s
33
Connection Boxes
Link Boxes 34
Add-on Kits for 145 kV Cable Accessories 37
34
Application
Single point bonding
Mid point grounding
Direct grounding
Grounding through SVL
Cross bonding and transposition
Features
Compact design
Stainless steel
Hermetically sealed
1-phase and 3-phase boxes
Sheath voltage limiters (SVL)
IP65 / IP 68
Removable links
For coaxial cable or single core
cable
Voltage withstand according to
IEC 60840 Annex H
Link Boxes
Cross bonding and sectionalisation for high-voltage cable systems
35
Link boxes and sheath voltage
limiters
Link boxes are used with cable joints
and terminations to provide easy
access to the screen of HV cables
for testing purposes and to reduce
induced voltages building up the
sheath due to load and short circuit
currents.
Lightning and switching operations
may cause transient over voltages
on the cable sheath. Sheath voltage
limiters (surge arresters) may be
integrated into the link boxes in order
to limit these over voltages.
Depending on the application differ-
ent link boxes are available.
Mechanical design
Made of stainless steel
1-phase and 3-phase link boxes
With and without SVL
Coaxial cables entry or single core
cable entry
Removable links
Compact design available
(no removable links)
Hermetically sealed
Tight up to a water level of 5 m
Lugs and bonding cables sealed
inside and outside the link box
with heat shrink tubes coated with
hot melt adhesive
Suitable for
Single point bonding
Mid point grounding
Direct grounding
Grounding through SVL
Cross bonding and transposition
Electrical design
Cross section of links up to 300 mm
2
Uc = 3 kV of 6 kV SVL
Short circuit current withstand 1 s
31.5 kA
BIL phase to ground / phase to
phase 40 kV
Application
Installation in pits or vaults and on
structures or poles
36
Description Comment Dimensions
LxWxH (mm)
Special properties
HVLB-GND-0/4-41-1PH-4WAY 1-Phase Link Box
for Direct Grounding Assembly
(4WAY)
496x862x320 4 cable entries, IP68, 3 mm stainless
steel, removable links, 300 mm
2

tinned copper links, BIL 40 kV, short
circuit current 31.5 kA/1 s
HVLB-GND-1/6 1-Phase Link Box
with 1 kV SVL Assembly
(6WAY)
340x725x293 6 cable entries, 1 kV SVL, compact
design, no removable links, stainless
steel
HVLB-GND-6/4-41-1PH-4WAY 1-Phase Link Box
with 6 kV SVL Assembly
(4WAY)
496x862x320 4 cable entries, IP68, 3 mm stainless
steel, removable links, 300 mm
2
tinned copper links, 6 kV SVL,
BIL 40 kV, short circuit current
31.5 kA/1 s
HVLB-GND-0/4-41-3PH 3-Phase Link Box
for Direct Grounding Assembly
469x725x320 IP 68, 3 mm stainless steel, remov-
able links, 300 mm
2
tinned copper
links, 6 kV SVL, BIL 40 kV, short
circuit current 31.5 kA/1 s
HVLB-GND-1/3 3-Phase Link Box
with 1 kV SVL Assembly
310x310x255 1 kV SVL, compact design, no
removable links, stainless steel
HVLB-GND-6/3 3-Phase Link Box
with 6 kV SVL Assembly
310x310x255 removable links, 240 mm
2
tinned
copper links, 6 kV SVL, stainless
steel, compact design
HVLB-GND-6/4-41-3PH 3-Phase Link Box
with 6 kV SVL Assembly
496x725x320 IP 68, 3 mm stainless steel, remov-
able links, 300 mm
2
tinned copper
links, 6 kV SVL, BIL 40 kV, short
circuit current 31.5 kA/1 s
HVLB-CRB-0/3-50-3PH 3-Phase Link Box
Cross Bonding
for Direct Grounding Assembly
355x883x621 coaxial cable entry, IP 68, 3 mm
stainless steel, removable links,
300 mm
2
tinned copper links,
BIL 40 kV, short circuit current
31.5 kA/1 s
HVLB-CRB-6/3-50-3PH 3-Phase Link Box
Cross Bonding
with 6 kV SVL Assembly
355x883x621 coaxial cable entry, IP 68, 3 mm
stainless steel, removable links,
300 mm
2
tinned copper links, 6 kV
SVL, BIL 40 kV, short circuit current
31.5 kA/1 s
EPPA-055-0/1 1-Phase Link Box
for Direct Grounding Assembly
300x190x165 compact design,
no removable links
EPPA-055-3/1 1-Phase Link Box
with 3 kV SVL Assembly
300x190x165 3 kV SVL, compact design,
no removable links
EPPA-055-6/1 1-Phase Link Box
with 6 kV SVL Assembly
300x190x165 6 kV SVL, compact design,
no removable links
EPPA-055-0/3 3-Phase Link Box
for Direct Grounding Assembly
310x310x255 compact design,
no removable links
EPPA-055-3/3 3-Phase Link Box
with 3 kV SVL Assembly
310x310x255 3 kV SVL, compact design,
no removable links
EPPA-055-6/3 3-Phase Link Box
with 6 kV SVL Assembly
310x310x255 6 kV SVL, compact design,
no removable links
Available Link Boxes
37
Application:
Add-on kits for HV cables with
integrated glass bres are available
for all Raychem 145 kV terminations
and joints. The add-on kits include all
required components to reliably seal
the cable and the glass bre outlet as
well as suitable tubes to protect the
sensitive steel pipes carrying the glass
bres. The standard kit can be used
for cables with up to two individual
steel pipes. Glass bre splicing kits
may be included in the add-on kits as
well. These kits are able to handle up
to 12 individual glass bres per steel
pipe. The commonly used FOSC 500
splicing kit is able to take two steel
pipes so up to 24 glass bres can be
spliced with this splice box. The box is
isolated and is therefore suitable for
cross bonding joints as well.
The glass bre outlet is arranged
straight, which means the pipe
doesnt need to be fold back. This
saves the pipe from being snapped
off because its smallest permitted
bending radius usually is bigger than
the diameter of the power cable.
For more details please contact your
relevant Sales Representative.
Add-on Kits for 145 kV Cable Accessories
38
I
n
s
t
a
l
l
a
t
i
o
n

&

T
o
o
l
s
39
Installation & Tools
Installation, Training and Supervision 40
Installation Requirements 41
Toolbox for the installation of
HV Cable Accessories 45
40
Installation, Training and Supervision
Tyco Electronics Raychem is an
independent supplier of HV cable
accessories. We provide our products
world wide to
utilities having their own installation
crews
contractors providing installation
services to utilities and industrial
customers
cable manufacturers
We are able to offer following
services:
Installations (accessories only)
Trainings (on-site and in-house)
Supervisions
Installations
Tyco Electronics has got well trained
and experienced jointers which
are able to carry out installation at
construction sites. Usually they are
supported by local helpers provided
by the contractor or the local utility.
In case there are no trained jointers
available locally ordering installation
services from us is the rst choice.
Training
Jointers with 5 years or more experi-
ence in HV cable preparation may be
trained on-site during an installation.
Less experience jointers should be
rst trained in our labs. In both cases
well experienced supervisors demon-
strate how to install our products in
order to ensure the high performance
expected to be enjoyed over the
whole life time of our products.
At the end of the training the jointers
will be able to carry out installations
without or at least with a minimum of
help provided by our supervisors.
Supervision
Jointers, which have been trained by
Tyco Electronics supervisors prior to
an installation but havent yet got suf-
cient on-site experience in installing
Tyco Electronics accessories, may
need the help of a supervisor on-site.
We recommend ordering this service
for the rst installations. If ensures
that all accessories are installed ac-
cording to the instructions provided
with the accessories.
For the installation of the cable accessories the construction side must be
prepared before. The installation requirements for the different products are
described on the following pages.
41
Installation Requirements
Cable accessories from Tyco Electron-
ics Raychem GmbH are very reliable in
service and offer a long maintenance-
free life cycle.
In order to assure both the installation
has to be carried out as described in
our installation instruction.
In addition to the process steps de-
scribed in our installation instructions
we recommend following commonly
accepted installation practice.
General
Joints EHVS
Minimum requirements for the
installation
Access to installation site for motor
vehicles / lorries.
Complete readiness of cable routing.
Joints may be directly buried (i.e. in
a concrete tray) or installed in man
holes. The size of the concrete tray
or the man hole should be 4 m x
10 m in order to allow the joints to
be staggered. In case the joints are
to be installed in-plane then size
may be reduced to 3 m x 5 m
Cables to be jointed shall overlap
by at least 2 m. Please consult the
relevant installation instruction for
details.
Temporary electric lighting at the
installation place (spot lights and
uorescent lamps)
Free power sockets 230 V, min. 10 A
Ambient temperature at installation
place shall be 15C min. In case of
lower ambient temperature, gas or
electric heaters are required.
Two or more helpers per installation
team
Taking into account the technical
complexity of accessories and their
installation procedure we strongly
recommend installations to be
carried out and supervised by well
trained and qualied installers only.
EHVS Installation
The sketch besides shows an example
for a concrete shelter in which the
joints have been staggered. The cable
is laid in a cable ducts installed on
metal poles of several meters height
Cable laying and jointing in a concrete duct.
42
A similar arrangement to the sketch
on the previous page is shown below.
Due to the limited space and two
systems to be jointed, the shelter has
got two stories.
The following sketch shows the top
view of the two previous arrange-
ments. The cables however are ar-
ranged in an underground cable duct.
Terminations OHVT
Minimum requirements for the
installation
Access to installation site for motor
vehicles / lorries.
Complete readiness of cable routing
including xing the cable to the
termination platform.
Depending on the dimension of the
termination to be installed the cable
end shall project above the termina-
tion base plate by 23 meters.
Temporary electric lighting at the
installation place (spot lights and
uorescent lamps)
Free power sockets 230 V, min. 10 A
Ambient temperature at installation
place shall be 15C min. In case of
lower ambient temperature, gas or
electric heaters are required.
Two or more helpers per installation
team.
Taking into account the technical
complexity of accessories and their
installation procedure we strongly
recommend installations to be
carried out and supervised by well
trained and qualied installers only.
Platforms (permanent):
Platforms have to be strong, tough
and rigid enough to withstand all
expected mechanical loads taking
into consideration the weight of the
terminations, dynamic forces caused
by short circuit currents, wind loads,
icing etc. and temporary loads like
those taking effect during installa-
tions.
The support structure shall be
equipped with a sufcient number
of non-metallic cable cleats xing
the cable to the support structure.
Spacing between the cable cleats
shall be coordinated with the cable
manufacturer.
The max. distance between the
termination gland and the nearest
cable cleat shall not exceed 1 m.
The platform, to which the individual
base plate of the termination is
assembled to, shall be level and
preferably horizontal. The mounting
holes for the base plate shall be as
per provided offer drawings.
In case the platform is more than
3 m above ground we recommend
contacting your relevant Sales
Representative to provide you with
additional details.
Scaffolding (temporary):
The use of scaffolding is strongly
recommended. It shall be equipped
with fences, handrails, stairs or rm
ladders and shall follow common
safety rules. The roof ridge shall be
solid enough to carry a load of ap-
prox. 100 kg (composite insulator).
The scaffolding shall have 2 levels.
The lower level shall be approx.
700 mm below the terminations
base plate, the upper level approx.
2 m above the lower one. The oors
may be prepared using wooden
planks or steel grids and shall be
able to carry min. 250 kg/m
2
.
Depending on weather conditions
the scaffolding may require to be
protected from the elements with
a tent or tarpaulin. The clearance
between the top oor and the roof
ridge shall be in the range of 3.0 m.
The tarpaulin should be easy to
remove to allow the insulator to be
lifted over the prepared cable easily.
The recommended size of the
scaffolding is 4 m x 4 m with the
termination in the center. In case the
terminations are installed side by
side the size shall be 8 m x 4 m.
43
OHVT platforms and scaffolding
The sketch below shows an example
for a platform including the scaffold-
ing for 3 terminations assembled side
by side.
Special actions may have to be
taken in case the vertical cable span
exceeds 3 m. The cable may require
more and/or special cable cleats to x
the cable reliably.
Features:
Weight-bearing capacity: 250 kg/m
2
Lifting capacity of block and tackle:
max. 5000 N
Weatherproof covering (transparent
tarpaulin) from the roof ridge down
to the upper level (summer)
Weatherproof covering (transparent
tarpaulin) from the roof ridge down
to the bottom level (winter)
OHVT Mounting
The terminations base plate shall
be mounted on a horizontal steel
structure similar to the one shown in
the sketch beside:
Chain block
2. platform
Sealing End
1. platform
Power Cable
Cable Support
Protection Pipe
44
OHVT Installation with Surge
Arrester
Similar platforms can be used for
both, outdoor terminations and surge
arresters installed together.
The clearance between termina-
tion and arrester has to follow local
regulations. By default it should be
1500 mm.
Surge Arresters are shown in a sepa-
rate chapter of this catalogue.
Switchgear & Transformer terminations
SHVT, THVT, PHVS, PHVT
Minimum requirements for the
installation
Access to installation site for motor
vehicles / lorries.
Forklift
Complete readiness of cable routing
including xing the cable to vertical
cable duct (if any).
The cable end shall project above
the lower cover of the cable entry
box by 1 meter.
Cable ducts underneath the opening
in the ceiling/oor for the cable shall
be xed temporarily only because
the cables have to be pulled back by
up to 3 meters for cable preparation.
Temporary electric lighting at the
installation place (spot lights and
uorescent lamps)
Free power sockets 230 V, min. 10 A
Ambient temperature at installation
place shall be 15C min. In case of
lower ambient temperature, gas or
electric heaters are required.
Two or more helpers per installation
team.
Taking into account the technical
complexity of accessories and their
installation procedure we strongly
recommend installations to be
carried out and supervised by well
trained and qualied installers only.
For questions please contact your
relevant Sales representative.
45
Toolbox for the installation of HV Cable Accessories
For the installation of the HV Cable
accessories we recommend using
our toolbox equipped with about 70
different tools (see right column).
(Cable stripping tool and straight-
ening set tool have to be ordered
separately, available as an extension
set as well)
For details on how to use the tools
during installation please contact
your Sales Representative and ask for
a price quotation on training/super-
vision.
List of Standard Tools and
Auxiliary Materials:
Cable Saw with Blade
Small Sanding Machine
Big Sanding Machine
Extension Cable Drum
Cordless Impact Wrench
Drill Machine
Set of Fork/Ring Spanners
Set of Hexagon Spanners
Big Screw Clamp
Small Screw Clamp
Pinch Bar
Big Box Spanner Assembly
Small Box Spanner Assembly
Big Sliding Caliper
Torque Wrench
Set of Files
Small Sliding Caliper
Wood Rasp
Set of Dowel Pin Fasteners
Big Hammer
Small Hammer
Club Hammer
Plastic Hammer
Set of Screw drivers
Engineers pliers
Edge Cutter
Pincers
Set of Ring Spanner
Halogen Radiator
Plastic Tarpaulin
Pressing Tool
Crane Rope
Spirit Level
Pipe Cutter
Adjustable Wrench
Set of Eyelet Pliers
Chain Host
Metal Saw
Set of Drills to unscrew Bolts
Set of White Marker Pens
Tape Ruler
Hook Knife
Jacket Removal Tool
Carton Abrasive Paper
Cleaning Paper Roll
Kitchen Foil Roll
Package of Latex gloves
Slide Rail for Cable Alignment*
Bottles with Cleaning Solvent*
Cable Knife*
Cable Stripper*
Screw Tap**
Electric Torch**
Metal Angle**
Precision Angle**
Water pump pliers**
Set of Mandrel and Chisel**
Rolls of Crepe Paper**
First Aid Box**
* Extension Set
** not included but recommended
Photo of toolbox available from Tyco
Semicon Stripping and insulation cutting
tool
Cable Straightening Set
46
S
u
b
s
t
a
t
i
o
n
47
Substation
Surge Arrester 48
High Voltage Connection System (HVCS) 72
48
S
u
r
g
e

A
r
r
e
s
t
e
r
49
Surge Arrester
Introduction 51
Application 51
Benets 51
Design Concept
I. Single Modules for single column and
series parallel surge arresters 52
A. Construction 52
B. Housing material 52
C. Applications 52
II. The Single Column Design 53
III. The Module Series Parallel Design 53
A. Voltage distribution and stress grading 53
B. Thermal ageing and partial discharge 53
C. Comparison between Series Parallel
and standard single column design 54
D. Electrical tests for Series Parallel
surge arrester 54
E. Advantages of the Series Parallel design 54
Appropriate Surge Arrester Selection
I. Electrical performance and housings 55
II. Surge Arresters for System Voltages
123 kV and 170 kV 56
III. Surge Arresters for System Voltages
245 kV and 362 kV 58
IV. Surge Arresters for System Voltages
420 kV and 550 kV 60
V. Accessories 62
VI. Transmission Line Surge Arresters for Overhead
Poles and Overhead Lines up to 150 kV 68
Additional Equipment
Surge Counter 70
Installations 71
50
4P11SR396 Series Parallel Surge Arrester
51
Introduction
Tyco Electronics Bowthorpe has been
manufacturing surge arresters for
over 60 years. Our knowledge and
experience we use to develop our
surge arrester range today.
Tyco Electronics is well known
for their insulation and protection
products worldwide. The range of
HV surge arresters up to 550 kV and
line discharge classes from 2 up to 5
operates in 130 countries in diverse
climates from the artic circle to the
tropics.
Since 1988 Tyco Electronics have
designed the patented series parallel
metal oxide surge arrester which is
special in construction and provides
many advantages over conventional
single column and multiple columns
porcelain and polymeric housed
arresters. They were designed and
tested to meet dened abnormal
service conditions as detailed in
Annex A of IEC 60099-4 (1991).
The special construction of this
series parallel surge arrester provides
electrical and mechanical properties
that cannot be obtained with single
or multiple column types. In particular
the geometry and unitary construc-
tion provides inherent voltage grading
that does not require additional
grading rings or further correction of
the maximum continous operating
voltage (Uc) required for arresters of
conventional construction.
For voltages up to 220 kV Tyco Elec-
tronics offers two types of Polymeric
Single Column Surge Arrester which
also have their benets based on the
construction and design.
Application
This range of Silicone Rubber housed
surge arresters is applicable for sub-
station equipment and transmission
lines. Because of their high cantilever
strength, they can be used to replace
the cable support insulators on HV
terminations. This results in simpli-
ed installation for HV terminations
at reduced cost which is aestheti-
cally more acceptabIe to the general
pubIic.
Benets
Low residual voltages
High protection margins
High TOV performance
Inbuilt stress grading along the full length
More effective grading per unit length than a single column type
Similar stress distribution like single column type, but without stress grading
ring
Resistant against Radial stress based on the gap free Bowthorpe patented
construction
Safe non-shattering short circuit behavior to higher current levels
High-energy handling
Direct molded housing to prevent moisture ingress
Hydrophobic and tracking and erosion resistant silicone housing
High pollution performance
Excellent cantilever and tensile performance
Excellent mechanical, vibration and impact withstand capability
Extremely strong mechanical strength
Low thermal ageing of varistor insulation
Smaller footprint than equivalent single column SA with grading ring
Modular design for quick installation and commission
Light weight
Capable to withstand seismic condition
Uniform current sharing
Maintenance free
Tested in accordance with IEC60099-4 at independent accredited
laboratories
Quality design and manufacturing, ISO 9001 and 14001 compliant
52
Design Concept
Many 1-column porcelain housed and
non-integrated polymeric housed
type surge arresters have some
limits. A few of them are the control
of uniform stress grading and the
radial eld strength which are the
most important issues in these surge
arrester design types. The high radial
eld would lead to discharge in the
surge arrester enclosure between the
porcelain inside and the metal oxide
varistors.
I. Single Modules for Single Column
and Series Parallel Surge Arrester
A. Construction
The Tyco Electronics Bowthorpe
patented surge arrester construc-
tion eliminates the air gap by direct
moulding of the silicone rubber hous-
ing onto the wrapped ZnO varistor
elements and the terminal assembly.
The applied ZnO varistors ensure a
very good electrical behaviour. The
polymeric housing and the shed form
(gure 1a) shows a good performance
in salt-fog tests.
B. Housing material
Housing material is a service proven
formulation of Silicone Rubber. The
silicone housing was developed using
the knowledge accumulated over
35 years of internal Tyco Electron-
ics materials science expertise and
experience, resulting in an optimum
shed prole and a material with excel-
lent tracking and erosion resistance.
This range of Silicone Rubber housed
surge arresters has been fully tested
to meet the very severe pressure-
relief tests.
C. Application
The advantages of the construction
and the housing material are used for
the Tyco Electronics Polymeric Surge
Arrester independant if they are build
in a single column design or in the
series parallel design.
Figure 1a: Tyco Electronics Bowthorpe
surge arrester core and series parallel surge
arrester.
Excellent hydrophobicity
Safe non-shattering failure mode
Track and Erosion Resistant
Corona Ring
Intermediate
metal work
Insulated
base
Aluminium
End Block
Silicone Rubber
Housing
Heat Sink
ZnO Varistor
Element
Die Cast Aluminium
Sealing End
Stainless Steel
Terminal Block
53
Figure 1c: Equivalent electric circuit
network and the additional capacitance
introduced by the series parallel surge
Key
R
MO,X
Voltage-dependent resistance
of section x
C
MO,X
Capacictance of section x
C
e, X
Stray Capacitance to earth at node x
n number of sections
II. The Single Column Design
Tyco Electronics offers two types of
single column Surge Arrester.
The construction of the arrester type
HSR is manufactured with the above
described modules. These arresters
are available for voltages up to 132 kV
as a class 2 Surge Arrester.
The type named PCA is designed as
a class 3 Surge Arrester for voltages
from 30 kV up to 220 kV.
III. The Module Series Parallel Design
Especially for higher voltages are
some features like voltage distribu-
tion, stress grading, thermal ageing,
partial discharge and the weight
important for the design of the Surge
Arrester. Tyco Electronics developed
the Module Series Parallel Design to
build up the advantages for these
higher voltages.
A. Voltage distribution and stress
grading
The voltage distribution is largely
governed by the surge arrester
geometry and intermediate plates.
The intermediate connection plates
of the series parallel surge arresters
provide additional natural grad-
ing capacitance. The intermediate
connection plates have stray capaci-
tances which cascade and shunt to
earth. Furthermore, the resistance and
capacitance of the non-linear varistors
also provide voltage grading.
The equivalent cascade capacitance
network (Fig. 1c) gives more uniform
electric eld distribution when com-
pared it with standard single column
porcelain or non-porcelain house
surge arrester with or without grading
ring. Intermediate connecting plates
assist the reduction in radial stress at
extremely high voltage sections.
The overall geometry of the modular
surge arrester is such that both radial
and longitudinal voltage stress was at
an acceptable value at an extremely
high system operating voltage.
B. Thermal ageing and partial
discharge
An exponential longitudinal voltage
grading of a surge arrester is undesir-
able phenomenon for varistor disks
especially for those which are in top
of the Surge Arrester. Low energy
ionisation of the parallel air gap due
to the high electrical stress would lead
to ageing and failure of the varistor
insulation. It has been established
that partial discharge activity in close
proximity to metal oxide varistors will
lead to rapid ageing and premature
failure. Therefore, the conventional
single column arrester requires a
grading ring for the additional reasons
other than uneven eld or thermal
considerations.
Equivalent circuit network (Fig. 2a)
can only handle the varistor element
in its linear model either before or
after the threshold turn on point.
For the former, varistors have high
resistance and its capacitance that
dictates the surge arrester voltage
grading. Beyond the turn on point
the varistors have low resistance and
this dominates the voltage grading.
Further more for the former case,
although the varistor or varistors are
seeing high stress, the equivalent
network as shown in gure 2a, has
high source impedance (Z). Under
these conditions the voltage across
the varistor will collapse as soon as
any signicant current commences
to ow.
The high equivalent source imped-
ance effectively limited the voltage
and current that can be applied to
the varistor elements located in top
surge arrestor section high stress
region. It is in this context that further
consideration must be given to actual
ageing mechanism.
Thermal ageing of the varistor would
be caused by the lack of self limiting
under the combination of high stress
and low source impedance. The series
parallel surge arrester design has
eliminated both, thermal and partial
discharge ageing to the metal oxide
arrester.
The Series Parallel surge arrester has
no internal air gaps and therefore
requires no grading ring to avoid
internal ionisation.
Figure 2b shows the coaxial circuit
approximation model and gure 2c
shows typical results obtained and
conrmed the near uniform longitu-
dinal voltage stress distribution. The
Series Parallel surge arrester does
not require external means such
as grading rings, to aid the voltage
distribution.
Figure 1b: Single column surge arrester
and core in cage design (type PCA)
Aluminium End
Fitting
Cage Design
Moulded Silicone
Sheds
ZnO Blocks
Pedestal Base
54
C. Comparison between series
parallel and single column design
There are differences and similarities
between the eld plot to a standard
single column porcelain house surge
arrester and the Series Parallel design.
They are summarized as follows:
The Series Parallel arrester has more
effective grading per unit length
than the single column type
Specially a Series Parallel 4P type
exhibits similar stress distribution
to the IEC example calculations, but
without use the oversize diameter
voltage grading rings
Radial stress is an issue for many
por celain housed design due to the
inbuilt air gap between the varistor
and the housing inner wall but not for
the gap free (integrated housing) Tyco
Electronics patented construction
D. Series Parallel surge arrester
electrical tests
The following standard IEC routine
testing for every series parallel surge
arrester units:
Reference voltage measurement
Partial discharge measurement
Leakage current measurement
Residual voltage measurement
In addition, a proprietary internal
procedure was introduced to check
the current sharing of parallel columns
within a series parallel surge arrester.
A proprietary process ensures that
between parallel columns the lowest
practical differences in characteristics
can be employed in one complete se-
ries parallel surge arrester. Therefore,
residual voltages, energy absorption
and heat dissipation are shared
among the parallel units.
E. Installation and maintenance ad-
vantages of the series parallel design
Good stress grading without the
need of oversize grading ring
Light weight no heavy lifting
equipment is required for installation
Light weight no heavy duty
foundation is required for the surge
arrester
Modular design quick installation
and commission
Lattice structure exceptional
strong mechanical strength
Non shatter of the surge arrester
housing transportation easiness
Non shatter of the surge arrester
housing no damage to personal
and nearby expensive equipments
Good pollution performance
maintenance free
Environmental acceptable material
maintenance free
The series parallel design is capable to
withstand seismic condition set in the
current international standards which
warrants reliable maintenance in all
regions.
0 10 20 30 40 50 60 70 80 90 100
Time (s)
Current
(2.0 kA/div)
CH1
Current
(2.0 kA/div)
CH2
Current
(2.0 kA/div)
CH3
Trace
Zeros
Figure 2b: Field plot of series surge arrester
using a coaxial circuit approximation model
Figure 2c: Field plot result of series parallel
surge arrester
A Varistor non-conduct
B Varistor partially conduct
C Varistor fully conduct
Figure 2a: Equivalent network
55
Surge Arrester Selection
System
Voltage
(kV)
Rated
Voltage
(kV)
Line
Discharge
Class
Long
Duration
Current
(A)
Nominal
Discharge
Current
(4/10 s)
(kA)
Rated Short
Circuit
Current
(kA)
Energy
Capability
at Ur acc. to
IEC 60099-4
(kJ/kV)
Type Page
123 84120 3 640 10 65 7.8 PCA 8
84126 2 450 10 40 4.5 HSR 8
96126 3 750 10 40 7.0 2PH 8
96120 4 1100 20 63 10.8 3P 8
108120 5 1500 20 63 12.5 4P 8
Neutral Ground 75 2 450 10 40 4.5 HSR 8
170 132150 3 640 10 65 7.8 PCA 8
132150 3 750 10 40 7.0 2PH 8
132150 4 1100 20 63 10.8 3P 8
132 5 1500 20 63 12.5 4P 8
Neutral Ground 96 2 450 10 40 4.5 HSR 8
Neutral Ground 96 3 750 10 40 7.0 2PH 8
245 180198 3 640 10 65 7.8 PCA 10
180214 4 920 20 63 10.8 3P 10
180214 5 1500 20 63 12.5 4P 10
Neutral Ground 168 3 750 10 40 7.0 2PH 10
362 240290 4 1100 20 63 10.8 3P 10
260290 5 1500 20 63 12.5 4P 10
Neutral Ground 180 3 920 20 63 9.4 3P 10
420 336-360 4 1100 20 63 10.8 3P 12
330393 5 1500 20 63 12.5 4P 12
336360 5 1500 20 63 16.4 5P 12
550 396-444 5 1500 20 63 12.5 4P 12
420468 5 1800 20 63 16.4 5P 12
Electrical Performance
High current inpulse (4/10 s) 100 kA (for all Surge Arrester types)
PCA HSR 2PH 3P 4P
56
Surge Arrester for System Voltages 123 kV and 170 kV
System
Voltage
(kV)
Ur*
(kV)
Uc**
(kV)
Line
Discharge
Class
Max. U res tested with current wave Steep
Current
1/20 s
Switching surge
30/60 s
Lightning Current
8/20 s
250 A
(kV)
1000 A
(kV)
5 kA
(kV)
10 kA
(kV)
20 kA
(kV)
10 kA
(kV)
123 84 67.2 3 169 180 209 219 240 238
96 76.8 3 189 201 234 245 268 266
108 86.4 3 209 222 259 270 296 294
120 96.0 3 239 254 296 209 339 336
84 67.0 2 171 183 209 225 248 256
87 70.0 2 178 192 219 235 259 267
91 73.0 2 183 197 225 242 266 273
95 76.0 2 193 208 237 255 281 288
96 76.8 2 193 208 237 255 281 288
98 79.0 2 198 213 243 261 288 295
102 82.0 2 208 224 256 275 303 309
106 85.0 2 216 232 265 285 314 320
108 86.4 2 218 235 268 288 317 323
110 88.0 2 221 237 271 291 321 327
120 96.0 2 241 259 296 318 350 355
126 101.0 2 253 272 311 334 369 373
95 76.0 3 191 203 227 241 261 272
96 76.8 3 191 203 227 241 261 272
98 79.0 3 198 210 235 250 271 281
103 82.4 3 205 218 244 260 281 291
106 84.8 3 213 226 253 269 291 301
108 86.4 3 213 226 253 269 291 301
110 88.0 3 220 234 262 278 301 311
114 91.2 3 227 242 270 287 311 321
120 96.0 3 235 249 279 297 321 331
121 96.8 3 242 257 288 306 311 340
126 101.0 3 249 265 296 315 341 351
96 76.8 4 188 198 219 232 249 262
98 79.0 4 195 206 228 241 258 272
103 82.4 4 202 213 236 250 268 281
105 84.0 4 202 213 236 250 268 281
108 86.4 4 209 221 245 259 278 291
120 96.0 4 231 244 270 285 306 319
108 86.4 5 207 218 240 253 271 283
120 96.0 5 229 241 265 280 299 311
Neutral Ground 75 60.0 2 151 162 185 199 219 223
Protective Characteristics
170 132 106.0 3 252 267 311 325 356 354
138 110.0 3 269 286 333 348 381 378
150 120.0 3 299 318 370 386 423 420
132 106.0 3 264 280 314 334 361 374
138 110.0 3 274 291 325 346 374 388
140 112.0 3 274 291 325 346 374 388
144 115.0 3 284 301 337 358 388 401
150 120.0 3 293 312 349 371 401 414
132 106.0 4 260 274 304 321 345 362
138 110.0 4 270 285 315 333 357 375
144 115.0 4 279 295 326 345 370 388
150 120.0 4 289 305 338 357 383 400
132 105.0 5 257 271 298 314 337 353
Neutral Ground 96 76.8 2 193 208 237 255 281 288
Neutral Ground 96 76.8 3 191 203 227 241 261 272
* Ur Rated Voltage Surge Arrester with other characterstics are available on request
** Uc Cont. Operating voltage
*** TOV curves are given in Technical data for selected Surge Arrester (on request)
**** Accessories selection see on the pages 6267
57
Temporary
Overvoltage
capability
for 1 sec***
(kV)
Creepage
length
(mm)
Overall
height
(mm)
Rec. Min.
distance
between
phase
centers
(mm)
Rec. Min.
distance
between
phase to
earth
(mm)
Max.
Cantilever
load
(N)
Weight
(kg)
Product code****
96.6 3625 1085 880 502 2500 26.5 PCA3-84
110.0 3625 1085 993 567 2500 26.5 PCA3-96
124.0 3625 1085 1106 632 2500 26.5 PCA3-108
138.0 3625 1085 1218 698 2500 36.5 PCA3-120
97.7 3975 1428 841 455 600 17 3HSRC(P)84L1E1M0(5)
102.0 3975 1428 1133 475 600 17 3HSRC(P)87L1E1M0(5)
106.0 3975 1428 1168 495 600 17 3HSRC(P)91L1E1M0(5)
111.0 3975 1428 1203 516 600 17 3HSRC(P)95L1E1M0(5)
112.0 3975 1428 1212 518 600 17 3HSRC(P)96L1E1M0(5)
115.0 3975 1428 1238 536 600 17 3HSRC(P)98L1E1M0(5)
120.0 3975 1428 1274 556 600 17 3HSRC(P)102L1E1M0(5)
124.0 3975 1428 1309 577 600 17 3HSRC(P)106L1E1M0(5)
127.0 3975 1428 1325 586 600 17 3HSRC(P)108L1E1M0(5)
128.0 3975 1428 1344 597 600 17 3HSRC(P)110L1E1M0(5)
140.0 3975 1428 1438 651 600 17 3HSRC(P)120L1E1M0(5)
147.0 3975 1428 1494 684 600 17 3HSRC(P)126L1E1M0(5)
109.0 3975 1454 1337 516 1000 35 2P3HSRC95L2E2M4
110.0 3975 1454 1346 521 1000 35 2P3HSRC96L2E2M4
113.0 3975 1454 1373 536 1000 35 2P3HSRC98L2E2M4
118.0 3975 1454 1412 559 1000 35 2P3HSRC103L2E2M4
121.0 3975 1454 1440 575 1000 35 2P3HSRC106L2E2M4
124.0 3975 1454 1459 586 1000 35 2P3HSRC108L2E2M4
126.0 3975 1454 1478 597 1000 35 2P3HSRC110L2E2M4
131.0 3975 1454 1516 619 1000 35 2P3HSRC114L2E2M4
138.0 3975 1454 1572 652 1000 35 2P3HSRC120L2E2M4
139.0 3975 1454 1581 657 1000 35 2P3HSRC121L2E2M4
145.0 3975 1454 1628 684 1000 35 2P3HSRC126L2E2M4
115.0 3975 1500 1612 521 2000 65 3P3SR96L2E2M7-4
117.0 3975 1500 1639 536 2000 65 3P3SR98L2E2M7-4
122.0 3975 1500 1678 559 2000 65 3P3SR103L2E2M7-4
124.0 3975 1500 1697 570 2000 65 3P3SR105L2E2M7-4
128.0 3975 1500 1725 586 2000 65 3P3SR108L2E2M7-4
141.0 3975 1500 1838 651 2000 65 3P3SR120L2E2M7-4
119.0 3975 1838 1725 586 2875 64 4P3SR108L2E2M7
132.0 3975 1838 1838 651 2875 64 4P3SR120L2E2M7
87.5 2650 950 759 407 900 11 2HSRC(P)75L1E1M0(5)
152.0 3625 1085 1851 1023 2500 PCA3-132
159.0 4725 1485 1908 1055 PCA31-138
173.0 4725 1485 2020 1121 PCA31-150
151.0 2650 952 1685 716 900 46 2P4HSRC132L2E2M4
159.0 5300 1936 1741 749 500 46 2P4HSRC138L2E2M4
160.0 5300 1936 1760 760 500 46 2P4HSRC140L2E2M4
166.0 5300 1936 1798 782 500 46 2P4HSRC144L2E2M4
172.0 5300 1936 1854 814 500 46 2P4HSRC150L2E2M4
159.0 5300 2000 1951 717 1875 84 3P4SR132L2E2M7
162.0 5300 2000 2007 749 1875 84 3P4SR138L2E2M7
170.0 5300 2000 2064 782 1875 84 3P4SR144L2E2M7
176.0 5300 2000 2120 814 1875 84 3P4SR150L2E2M7
145.0 5300 1951 1951 716 2750 86 4P4SR132L2E2L7
112.0 3975 1428 1212 521 600 17 3HSRC(P)96L1E1M0(5)
110.0 3975 1454 1346 521 1000 35 2P3HSRC96L2E2M4
58
Surge Arrester for System Voltages 245 kV and 362 kV
System
Voltage
(kV)
Ur*
(kV)
Uc**
(kV)
Line
Discharge
Class
Max. U res tested with current wave Steep
Current
1/20 s
Switching surge
30/60 s
Lightning Current
8/20 s
250 A
(kV)
1000 A
(kV)
5 kA
(kV)
10 kA
(kV)
20 kA
(kV)
10 kA
(kV)
245 180 144 3 350 372 433 453 496 492
192 154 3 379 402 468 489 536 532
196 157 3 389 413 480 502 550 546
198 158 3 389 413 480 502 550 546
180 144 4 349 368 408 431 463 484
183 146 4 361 381 422 446 479 500
186 149 4 361 381 422 442 479 500
192 154 4 373 394 436 461 495 516
194 155 4 385 407 450 475 511 532
198 158 4 385 407 450 471 511 532
201 161 4 397 419 464 490 527 548
205 164 4 397 419 464 486 527 548
214 171 4 421 445 492 520 558 580
180 144 5 345 364 401 422 452 472
183 146 5 357 377 414 437 468 487
186 149 5 357 377 414 437 468 487
192 154 5 369 389 428 451 483 503
198 158 5 381 402 442 466 499 517
201 161 5 393 414 456 480 514 533
204 153 5 393 414 456 480 514 533
214 171 5 393 414 456 480 514 564
Neutral Ground 168 134 3 332 353 395 420 454 466
Protective Characteristics
362 240 192 4 472 498 552 582 625 656
264 211 4 522 551 611 645 692 723
268 214 4 522 551 611 645 692 723
271 217 4 522 551 611 645 692 723
276 221 4 539 569 630 666 715 745
279 223 4 539 569 630 666 715 745
283 226 4 556 587 650 686 737 767
286 229 4 556 587 650 686 737 767
288 230 4 556 587 650 680 737 767
290 232 4 573 605 670 707 760 789
260 208 5 495 522 575 606 648 682
264 211 5 514 542 597 629 673 705
268 214 5 514 542 597 629 673 705
271 217 5 533 562 619 652 698 731
276 221 5 533 562 619 652 698 731
279 223 5 533 562 619 652 698 731
283 226 5 552 583 641 675 723 756
288 230 5 552 583 641 675 723 756
290 232 5 552 583 641 675 723 756
Neutral Ground 180 144 3 349 368 408 431 463 484
* Ur Rated Voltage Surge Arrester with other characterstics are available on request
** Uc Cont. Operating voltage
*** TOV curves are given in Technical data for selected Surge Arrester (on request)
**** Accessories selection see on the pages 6267
59
Temporary
Overvoltage
capability
for 1 sec***
(kV)
Creepage
length
(mm)
Overall
height
(mm)
Rec. Min.
distance
between
phase
centers
(mm)
Rec. Min.
distance
between
phase to
earth
(mm)
Max.
Cantilever
load
(N)
Weight
(kg)
Product code****
207 5440 1675 2305 1284 40.5 PCA32-180
221 7250 2170 2415 1349 53 PCA33-192
225 7250 2170 2453 1370 53 PCA33-196
228 7250 2170 2472 1381 53 PCA33-198
210 6625 2500 2402 978 1750 103 3P5SR180L2E2M7-4
216 6625 2500 2430 993 1750 103 3P5SR183L2E2M7-4
219 6625 2500 2458 1009 1750 103 3P5SR186L2E2M7-4
225 6625 2500 2515 1042 1750 103 3P5SR192L2E2M7-4
229 6625 2500 2534 1053 1750 103 3P5SR194L2E2M7-4
232 6625 2500 2571 1075 1750 103 3P5SR198L2E2M7-4
237 6625 2500 2599 1091 1750 103 3P5SR201L2E2M7-4
242 6625 2500 2637 1113 1750 103 3P5SR205L2E2M7-4
250 6625 2500 2722 1161 1750 103 3P5SR214L2E2M7-4
198 6625 2500 2402 977 2625 108 4P5SR180L2E2M4-5
201 6625 2500 2430 993 2625 108 4P5SR183L2E2M4-5
204 6625 2500 2458 1009 2625 108 4P5SR186L2E2M4-5
211 6625 2500 2515 1042 2625 108 4P5SR192L2E2M4-5
218 6625 2500 2571 1075 2625 108 4P5SR198L2E2M4-5
221 6625 2500 2599 1091 2625 108 4P5SR201L2E2M4-5
224 6625 2500 2628 1107 2625 108 4P5SR204L2E2M4-5
235 6625 2500 2722 1161 2625 108 4P5SR214L2E2M4-5
193 5300 1936 2023 912 500 46 2P4HSRC168L2E2M4
283 9275 3500 2966 1303 1500 141 3P7SR240L2E2M7-4
312 9275 3500 3192 1433 1500 141 3P7SR264L2E2M7-4
316 9275 3500 3229 1454 1500 141 3P7SR268L2E2M7-4
320 9275 3500 3257 1471 1500 141 3P7SR271L2E2M7-4
326 9275 3500 3304 1498 1500 141 3P7SR276L2E2M7-4
329 9275 3500 3333 1514 1500 141 3P7SR279L2E2M7-4
334 9275 3500 3370 1536 1500 141 3P7SR283L2E2M7-4
337 9275 3500 3398 1552 1500 141 3P7SR286L2E2M7-4
339 9275 3500 3417 1563 1500 141 3P7SR288L2E2M7-4
342 9275 3500 3436 1574 1500 141 3P7SR290L2E2M7-4
286 10600 4000 3154 1411 2250 170 4P8SR260L2E2M7
290 10600 4000 3192 1433 2250 170 4P8SR264L2E2M7
295 10600 4000 3229 1454 2250 170 4P8SR268L2E2M7
298 10600 4000 3257 1471 2250 170 4P8SR271L2E2M7
303 10600 4000 3304 1498 2250 170 4P8SR276L2E2M7
307 10600 4000 3333 1514 2250 170 4P8SR279L2E2M7
311 10600 4000 3370 1536 2250 170 4P8SR283L2E2M7
317 10600 4000 3417 1563 2250 170 4P8SR288L2E2M7
319 10600 4000 3436 1574 2250 170 4P8SR290L2E2M7
210 6625 3500 2402 977 1750 103 3P5SR180L2E2M7
60
Surge Arrester for System Voltages 420 kV and 550 kV
System
Voltage
(kV)
Ur*
(kV)
Uc**
(kV)
Line
Discharge
Class
Max. U res tested with current wave Steep
Current
1/20 s
Switching surge
30/60 s
Lightning Current
8/20 s
250 A
(kV)
1000 A
(kV)
5 kA
(kV)
10 kA
(kV)
20 kA
(kV)
10 kA
(kV)
420 336 269 4 655 691 765 808 868 902
336 269 4 650 686 760 802 862 901
360 288 4 693 732 810 856 919 958
360 288 4 698 737 816 862 925 969
330 264 5 629 663 729 769 823 855
360 288 5 686 723 796 839 898 934
336 269 5 643 678 746 786 842 883
360 288 5 691 728 801 844 904 945
381 305 5 810 854 939 990 1060 1098
385 308 5 810 854 939 990 1060 1098
389 311 5 810 854 939 990 1060 1098
393 314 5 857 904 994 1048 1122 1161
336 269 5 643 678 746 786 842 915
360 288 5 686 723 769 839 898 934
Protective Characteristics
* Ur Rated Voltage Surge Arrester with other characterstics are available on request
** Uc Cont. Operating voltage
*** TOV curves are given in Technical data for selected Surge Arrester (on request)
**** Accessories selection see on the pages 6267
550 396 317 5 857 904 994 1048 1122 1161
400 320 5 857 904 994 1048 1122 1161
404 323 5 857 904 994 1048 1122 1161
408 326 5 857 904 994 1048 1122 1161
411 329 5 857 904 994 1048 1122 1161
396 317 5 864 912 1003 1057 1132 1175
400 320 5 864 912 1003 1057 1132 1175
404 323 5 864 912 1003 1057 1132 1175
408 326 5 864 912 1003 1057 1132 1175
411 329 5 864 912 1003 1057 1132 1175
415 332 5 864 912 1003 1057 1132 1175
419 335 5 891 939 1033 1089 1166 1208
420 336 5 891 939 1033 1089 1166 1208
423 338 5 891 939 1033 1089 1166 1208
444 355 5 943 994 1094 1153 1235 1341
405 324 5 886 934 1028 1083 1160 1208
409 327 5 886 934 1028 1083 1160 1208
413 330 5 886 934 1028 1083 1160 1208
416 333 5 886 934 1028 1083 1160 1208
420 336 5 886 934 1028 1083 1160 1208
424 339 5 886 934 1028 1083 1160 1208
428 342 5 943 994 1094 1153 1235 1282
431 345 5 943 994 1094 1153 1235 1282
435 348 5 943 994 1094 1153 1235 1282
444 355 5 943 994 1094 1153 1235 1282
420 336 5 891 939 1033 1089 1166 1208
444 355 5 934 994 1094 1153 1235 1277
420 336 5 886 934 1028 1083 1160 1208
444 355 5 943 994 1094 1153 1235 1282
468 374 5 972 1025 1127 1188 1272 1319
61
Temporary
Overvoltage
capability
for 1 sec***
(kV)
Creepage
length
(mm)
Overall
height
(mm)
Rec. Min.
distance
between
phase
centers
(mm)
Rec. Min.
distance
between
phase to
earth
(mm)
Max.
Cantilever
load
(N)
Weight
(kg)
Product code****
388 10600 4000 3868 1824 1375 159 3P8SR336L2E2M7-4
397 11925 4500 3868 1824 1250 178 3P9SR336L2E2M7-4
423 11925 4500 4094 1954 1250 178 3P9SR360L2E2M7-4
426 13250 5000 4094 1954 1125 197 3P10SR360L2E2M7-4
364 10600 3812 3812 1791 2250 170 4P8SR330L2E2M7
397 11925 4575 4094 1954 2125 190 4P9SR360L2E2M7
370 13250 5075 3868 1824 2000 210 4P10SR336L2E2M7
397 13250 5075 4094 1954 2000 210 4P10SR360L2E2M7
419 13250 5075 4291 2068 2000 210 4P10SR381L2E2M7
424 13250 5075 4329 2089 2000 210 4P10SR385L2E2M7
428 13250 5075 4367 2111 2000 210 4P10SR389L2E2M7
432 13250 5075 4404 2133 2000 210 4P10SR393L2E2M7
370 11925 4575 3868 1824 2400 236 5P9SR336L2E2M7
396 11925 4575 4094 1954 2400 236 5P9SR360L2E2M7
436 13250 5075 4432 2149 2000 210 4P10SR396L2E2M7
440 13250 5075 4470 2171 2000 210 4P10SR400L2E2M7
444 13250 5075 4508 2193 2000 210 4P10SR404L2E2M7
449 13250 5075 4545 2214 2000 210 4P10SR408L2E2M7
452 13250 5075 4573 2231 2000 210 4P10SR411L2E2M7
436 14575 5575 4432 2149 1875 230 4P11SR396L2E2M7
440 14575 5575 4470 2171 1875 230 4P11SR400L2E2M7
444 14575 5575 4508 2193 1875 230 4P11SR404L2E2M7
449 14575 5575 4545 2214 1875 230 4P11SR408L2E2M7
452 14575 5575 4573 2231 1875 230 4P11SR411L2E2M7
457 14575 5575 4611 2252 1875 230 4P11SR415L2E2M7
461 14575 5575 4649 2274 1875 230 4P11SR419L2E2M7
463 14575 5575 4658 2279 1875 230 4P11SR420L2E2M7
465 14575 5575 4686 2296 1875 230 4P11SR423L2E2M7
488 14575 5575 4884 2410 1875 230 4P11SR444L2E2M7
446 14575 5575 4517 2198 1875 250 4P12SR405L2E2M7
450 15900 6075 4555 2220 1750 250 4P12SR409L2E2M7
454 15900 6075 4592 2241 1750 250 4P12SR413L2E2M7
458 15900 6075 4620 2258 1750 250 4P12SR416L2E2M7
463 15900 6075 4658 2279 1750 250 4P12SR420L2E2M7
466 15900 6075 4696 2301 1750 250 4P12SR424L2E2M7
471 15900 6075 4733 2323 1750 250 4P12SR428L2E2M7
474 15900 6075 4761 2339 1750 250 4P12SR431L2E2M7
479 15900 6075 4799 2361 1750 250 4P12SR435L2E2M7
486 15900 6075 4884 2410 1750 250 4P12SR444L2E2M7
462 14575 5575 4658 2279 2200 250 5P11SR420L2E2M7
488 14575 5575 4884 2410 2200 250 5P11SR444L2E2M7
462 15900 6075 4658 2279 2000 250 5P12SR420L2E2M7
488 15900 6075 4884 2410 2000 250 5P12SR444L2E2M7
512 15900 6075 5109 2540 2000 250 5P12SR468L2E2M7
62
HSRC
HSRCP
Modular Single Column Polymeric Surge Arrester Type HSR
Line lead accessories
L1
50 mm stud
with washers
and nut M 16
L2
Line clamp to
suit conductors
up to 16 mm
L5
Line clamp to
suit conductors
up to 35 mm
L6
Aluminium
stem 30 mm
x 80 mm high
Earthing accessories
E1
2 x M 10 x
20 mm Hexago-
nal headed set
screws and
spring washers
E2
Earth clamp to
suit conductors
up to 16 mm
E5
Earth clamp to
suit conductors
up to 35 mm
Mounting accessories
M5
4 Hole Pedestal
Base 127-140
PCD (Pitch Circle
Diameter)
M3
Set of 4 Poly-
bre Base Insu-
lators supplied
with M5
M0
Without xing
accessories
M10
Single Polybre
Insulator
Arrester Type = Rated Voltage Ur in kV
Sample: 3 HSRC 110 L2 E2 M4
Parallel Paths Mounting
Arrester Housing Earth Terminal
Voltage Line Terminal
2HSRC 2HSRCP
48.00 60.00
72.00 75.00
83.75 87.50
91.25 95.00
96.00 98.75
102.50 106.25
108.00 110.00
63
Modular Polymeric Surge Arresters Type 2PH
L5
Line clamp to suit
cables up to 35 mm
L2
Aluminium stem
30 mm x 80 mm high
Sample: 2P 3HSRC 110 L2 E2 M4
Parallel Paths Mounting
Series Stages Earth Terminal
Voltage Line Terminal
L3
Line clamp to suit
cables up to 16 mm
E5
Earth clamp to suit
cables up to 35 mm
E1
2 x M10 x 20 mm
Hexagonal headed
set screws and
spring washer
E2
Earth clamp to suit
cables up to 16 mm
Silicone Rubber
Housed Arrester
Module
Aluminium
Connection Strap
M4
Set of 2 Polybre
Base Insulators
64
Modular Polymeric Surge Arresters Type 3P
L5
Line clamp to suit
cables up to 35 mm
L2
Aluminium stem
30 mm x 80 mm high
Sample: 3P 8SR 336 L2 E2 M7
Parallel Paths Mounting
Series Stages Earth Terminal
Voltage Line Terminal
L3
Line clamp to suit
cables up to 16 mm
E5
Earth clamp to suit
cables up to 35 mm
E1
2 x M10 x 20 mm
Hexagon headed set
screws and spring
washers
E2
Earth clamp to suit
cables up to 16 mm
Silicone Aluminium
intersection cross-arm
Corona Shield
M7
3 Polybre Base
Insulators connected
to galvanised steel
plate
Corona Ring
Silicone Rubber
Housed Arrester
Module
65
Modular Polymeric Surge Arresters Type 4P
L5
Line clamp to suit
cables up to 35 mm
L2
Aluminium stem
30 mm x 80 mm high
Sample: 4P 8SR 336 L2 E2 M7
Parallel Paths Mounting
Series Stages Earth Terminal
Voltage Line Terminal
L3
Line clamp to suit
cables up to 16 mm
E5
Earth clamp to suit
cables up to 35 mm
E1
2 x M10 x 20 mm
Hexagon headed set
screws and spring
washers
E2
Earth clamp to suit
cables up to 16 mm
Silicone Aluminium
intersection cross-arm
Corona Shield
M7
4 Polybre Base
Insulators connected to
galvanised steel plate
Corona Ring
Silicone Rubber
Housed Arrester
Module
66
Line Accessories
L5 2P L2 L3 HSR L6
Earthing accessories
E5 2P E5 3P E5
2P E2 3P E2 / HSRP E2
67
Mounting accessories
HSR M10
M5
4P M7 3P M7
HSR M3
M0
No mounting
68
Transmission Line Surge Arresters TLA
Lightning is responsible for approximately 65% of all of the non-scheduled out-
ages occurring on transmission lines.
Power supply utilities have veried the load losses due to voltage sags in their
systems from transitory outages caused by lightning activity and in some
regions they have found serious permanent damages on important lines.
The effect of transitory disturbances on transmission lines can also be more
critical in areas with high ground resistivity when associated with high lightning
activity.
Although a fault time is shorter than 1 minute, in many cases this is still unac-
ceptable. This loss of supply is critical for all modern industries, electronical
equipment and especially production processes.
In most cases line arresters (TLA), electrically connected in parallel with the
insulating string, have been considered as the most effective method currently
applied to improve transmission line performance, especially when associated
with improvements of the grounding system and usually presents the best
benet versus cost relationship in reducing ashovers of the insulator string due
to excessive voltages.
Generic Technical data
Specication IEC60099-4
Classication 10 kA
Voltage Rating 10 to 192 kV
High Current
Performance 100 kA
Line Discharge Class 2
Minimum Energy
Capability acc. to
IEC 60099-4 at Ur 4,5 kJ/kV
Disconnect Device tested
in accordance with IEC 60099-4
Insulation Material Silicone
Rubber
Vibration Tested Report No.
BOE002000
Features & Benets
HV arrester suspended from a
transmission line giving enhanced
transmission line performance
Increasing system line voltage on
standard insulated transmission lines
Minimising circuit breaker opera-
tion with possible system outage
resulting from back ashover on the
transmission line
Switching overvoltages are ab-
sorbed over the length of the line
reducing the severity of surge at the
substation
Transmission systems can be oper-
ated even where sub-soil gives poor
tower footing resistance
Eliminating interrupted power sup-
ply for sensitive industrial processes
Installing TLA on a standard 3 phase
voltage system along the line, at cal-
culated intervals, allows for optimum
performance of the TLA, to give
an increased system line voltage.
Therefore eliminating the need to
increase the standard insulation level
required on conventional system
upgrade.
Earthing Conguration
Accessories
TLA Pivot Suspension Clamp
Clamp Conductor Dimensions in mm U
Bolt
Weight
Range
Diameter
A B C D Torque
L2 9.519 mm 180 80 90 40 45 Nm 1.8 kg
L3 1830 mm 217 90 110 50 45 Nm 3.0 kg
L4 3045 mm 267 100 120 64 75 Nm 4.3 kg
L5 4565 mm 320 120 140 86 75 Nm 6.0 kg
TLA Disconnect E1
TLA Strain Relief System E2
Suspension Clamp
Grading Ring
for voltages
above 150 kV
Silicone Rubber
Insulation
Disconnect Device
Earth Cable with
Strain Relief
TLA Surge Arrester
Disconnect Device
Earth Connection
TLA Surge Arrester
Disconnect Device
Earth Connection
TLA Surge Arrester
Strain Relief Wire
Connection
Suspension Clamp
Assembly
Copper Shoring
Braid/Cable
TLA Surge Arrestor
Galvanic Steel
Clamp Straps &
Podings
Galvanised
Steel Line
palm
M 16 x 35 Min.
Full Thread
M 12 Connection
For Shoring
Braid/Cable
Aluminium
Line Clamp
69
Ur*
(kV)
Uc**
(kV)
Max. U res tested with current wave Seep
Current
1/20 s
Temporary
Over-
voltage
capability
for 1 s***
(kV)
Creepage
length
(mm)
Overall
height
(mm)
Product code****
Switching surge
30/60 s
Lithtning Current
8/20 s
125 A
(kV)
500 A
(kV)
5 kA
(kV)
10 kA
(kV)
20 kA
(kV)
10 kA
(kV)
15 12.0 31.1 33.3 41.4 45.9 51.6 46.7 17.1 930 321 TLA1B15L1E1M2
18 14.0 39.2 41.7 50.5 54.4 61.8 59.5 20.5 930 321 TLA1B18L1E1M0
21 17.0 43.8 46.5 56.4 61.4 69.0 67.1 24.0 930 321 TLA1B21L1E1M0
24 19.0 50.1 53.2 64.5 69.5 78.9 75.6 27.4 930 321 TLA1B24L1E1M0
27 22.0 54.8 58.2 70.6 76.3 86.4 83.3 30.8 930 321 TLA1B27L1E1M0
30 24.0 60.9 64.8 78.5 84.6 96.0 92.0 34.2 1310 476 TLA1C30L1E1M0
36 29.0 71.8 76.3 92.4 100.0 113.0 108.0 41.1 1310 476 TLA1C36L1E1M0
39 31.0 76.4 81.2 98.4 106.0 120.0 115.0 44.5 1310 476 TLA1C39L1E1M0
42 34.0 82.7 87.8 106.0 115.0 130.0 125.0 47.9 2000 476 TLA1E42L1E1M0
45 36.0 88.8 94.4 114.0 123.0 140.0 134.0 51.3 2000 476 TLA1E45L1E1M0
48 38.4 93.9 100.0 121.0 130.0 148.0 142.0 54.8 2620 952 TLA2C48L1E1M0
60 48.0 115.0 122.0 148.0 160.0 182.0 174.0 68.4 2620 952 TLA2C60L1E1M0
72 57.6 137.0 146.0 176.0 190.0 216.0 207.0 82.0 2620 952 TLA2C72L1E1M0
75 60.0 144.0 153.0 186.0 200.0 227.0 218.0 85.5 2620 952 TLA2C75L1E1M0
84 67.2 159.0 169.0 204.0 220.0 250.0 240.0 95.8 4000 952 TLA2E84L1E1M0
96 76.8 182.0 193.0 234.0 252.0 286.0 275.0 109.0 4000 952 TLA2E96L1E1M0
108 86.4 202.0 215.0 260.0 281.0 319.0 305.0 123.0 3930 1428 TLA3C108L1E1M0
120 96.0 225.0 239.0 286.0 312.0 354.0 339.0 137.0 3930 1428 TLA3C120L1E1M0
138 110.0 261.0 277.0 336.0 362.0 411.0 394.0 157.0 6000 1428 TLA3E138L1E1M0
144 115.0 271.0 288.0 349.0 377.0 427.0 410.0 164.0 6000 1428 TLA3E144L1E1M0
150 120.0 285.0 303.0 367.0 396.0 449.0 430.0 171.0 5240 1904 TLA4C150L1E1M0
168 134.0 314.0 333.0 404.0 435.0 494.0 474.0 192.0 8000 1904 TLA4E168L1E1M0
180 144.0 338.0 359.0 435.0 470.0 533.0 511.0 205.0 8000 1904 TLA4E180L1E1M0
192 154.0 376.0 399.0 484.0 521.0 594.0 591.0 219.0 8000 1904 TLA4E192L1E1M0
Protective Characteristics
* Ur Rated Voltage Surge Arrester with other characterstics are available on request
** Uc Cont. Operating voltage
*** TOV curves are given in Technical data for selected Surge Arrester (on request)
**** Accessories selection see on left page
TLA 1: 1545 kV TLA 2: 4096 kV TLA 3: 108144 kV TLA 4: 150192 kV
70
Surge Counters Type SC 12 & SC 13
The Tyco Electronics Bowthorpe EMP
range of Surge Arrester monitoring in-
struments are fully tested for use with
any manufacturers surge arrester. The
SC 12 is a Surge Counter only, whilst
the SC 13 provides the additional
measurement of total leakage current.
The analogue instrument provides
a means of monitoring the current
through the arrester and the leak-
age current over the surface of the
arrester housing. Signicant changes
after installation may indicate a
deterioration in the arrester or a build
up of surface contamination.
These instruments, which require
no auxiliary supply, are designed for
installation in the earth connections of
a single surge arrester or alternatively
the SC 12 may be used with the com-
mon earth of a three phase set.
Fully weatherproofed and sealed for
life they are housed in a one piece
gravity die cast aluminium case coat-
ed to enhance its already high degree
of resistance to surface corrosion.
The glass viewing window is sealed in
place, using a silicon rubber adhesive,
and a desiccator is enclosed to ensure
any residual moisture trapped during
sealing is absorbed for the service life
of the counter. Mounting is effected
by means of an integrally cast lug at
the rear of the case providing a single
clearance hole for the galvanized steel
M 12 bolt supplied.
The SC 12 and SC 13 are service
proven and require no special mainte-
nance or servicing apart from general
cleaning of the glass viewing window
and the moulded epoxy resin line
bushing.
Meter: 6 digit cyclometer at least 5 counts/second
Minimum count current: 200 A 8/20 microsecond wave
Maximum High Current Withstand: 100 kA 4/10 microsecond wave
Nominal Residual Voltage
withstand at 100 kA with
4/10 s Wave: 5 kV peak
Meter scale: 030 mA Peak (bilinear scale) Ref SC 13
2
SC 13 leakage: 050 mA Peak (bilinear scale) Ref SC 13L
2
Both counters can be supplied with an auxiliary contact rated 1,0 A 250V for
connection to remote signaling equipment. If required put sufx e.g. SC 12/AC.
M12 x 35 galvanized
steel with full nut and
springwasher
Ground terminal M12 Nickel
plated brass tted with 2-nickel
plated brass locknuts
Line termination M12 nickel plated brass tted
with 2-nickel plated brass locknuts
Moulded resin insulator
Hermetically sealed glass display panel
71
Installations
400 kV Surge Arrester
Damhead Creek, UK
500 kV Surge Arrester Indonesia 400 kV Surge Arrester Statnet
66 kV Surge Arresters Statkraft, Norway
300 kV Surge Arrester Statnet
110 kV Surge Arresters Estonia
132 kV Surge Arresters Statkraft, Norway
72
H
V

C
o
n
n
e
c
t
i
o
n

S
y
s
t
e
m
73
HV Connection System
Introduction 74
Connectors for Copper or Aluminium conductors
& Copper or Aluminium terminals
220 kV Bronze, Aluminium & Bimetal Range 75
Connectors for Aluminium conductors
& Aluminium or Copper terminals
330 kV Sinemex Range 76
Connectors for Aluminium conductors
& Aluminium or Copper terminals
550 kV Anti-Corona Range 77
Connectors for Aluminium conductors
& Aluminium or Copper terminals
800 kV Extra High Voltage Connectors 78
UNIVERSAL Connectors 79
74
Introduction
For more than 60 years, Tyco
Electronics SIMEL has been continu-
ously expanding and manufacturing
connectors for Grid Stations in France
and throughout the world.
The various ranges of:
Bronze, Aluminium & Bimetallic
connectors up to 220 kV
Connectors according to NEMA-CC1
Standard up to 330 kV
Connectors for Aluminium cables or
tubes up to 550 kV
Connectors up to 800 kV
UNIVERSAL connectors
are shown in the following pages as a
small overview.

These pages are only a capability of
available connectors.
Therefore we recommend the
customer to contact us with his
requirements and we should be in
position to nd the right solution for
his application.
It is necessary to know the conditions
of the substation project like:
Operating Voltage
Conductor type (Material, Diameter)
Nominal Current
Short-circuit current
Applicable Standards
Connection type
(bolted, crimped, welded)
Working conditions
Tyco Electronics SIMEL has expertise
level into the substation elds and
can provide technical support to
customers engineering teams in order
to establish the best selection of
products t for each application.
To nd a product for your application,
please contact your representative
Sales Engineer.
The products are subject to strict
controls during the manufacturing,
according to our quality control
manual, in order to meet the require-
ments of the ISO 9001: 2000 &
ISO 14001: 2004.
All our connectors comply with
criteria of standards such as IEC, VDE,
NEMA, ANSI, etc
The tests requested by the main
worldwide standards like
Heating test
Electrical Resistance test
Mechanical Cantilever test
Short-Circuit current test
RIV/Corona test
have already been performed on our
connectors.
SIMEL laboratory is COFRAC accred-
ited as an independent lab following
ISO CEI 1725 and can perform usual
required type tests such as tempera-
ture rise, resistance & mechanical
75
Connectors for Copper or Aluminium conductors
& Copper or Aluminium terminals
220 kV Bronze, Aluminium & Bimetal Range
Bolted Applications:
Bronze connectors for Copper
conductors to Copper conductors or
copper terminals
Aluminium connectors for Alumi-
nium conductors to Aluminium
conductors or Aluminium terminals
Bimetal connectors for Aluminium
or Copper conductors to Aluminium
or Copper conductors or terminals
Principle is provided by assembling
a bimetallic sheet in between Alumini-
um and bronze part.
Standard capacities:
Al or Cu tube diameter:
20 to 120 mm
Cu cable cross section:
50 to 600 mm
2
Al cable cross section:
75 to 1144 mm
2
Al or Cu stud diameter:
M12 to 60 mm
Al or Cu palm:
50, 60, 80, 100, 125, 100x200 mm
or whatever required
Connectors are available such as:
conductor ttings
rigid, sliding & expansion busbar
connectors & supports
terminal connectors on stud or
palms
earthing & grounding applications
possibility of providing 330 kV
copper alloy range

Al. straight expansion terminal pad Bi-metallic straight terminal pad Bronze tee connector
Al. tee connector Bi-metallic straight connector pad Bronze straight expansion connector
76
Applications:
This range meets the requirements of
NEMAC-CC1 1984 and 107 standards
for a maximum operating voltage of
330 kV.
It allows a bolted connection from:
Aluminium conductors to Aluminium
conductors or Aluminium terminals
Aluminium conductors to copper
terminals wherever applicable
Standard capacities:
Al Tube diameter:
50 to 250 mm
Al cable cross section:
75 to 1144 mm
2
Al or Cu stud diameter:
20 to 80 mm
Al or Cu palm:
50, 60, 80, 100, 125, 100x200 mm
or whatever required
Bundle spacing:
100, 200 mm,
or whatever required
Connectors are available such as:
conductor ttings
terminal connectors on stud or
palms
earthing applications

Connectors for Aluminium conductors & Aluminium or Copper terminals


330 kV Sinemex Range
Al. tee connector
Al. straight connector
77
Applications:
This range of connectors can be used
up to 550 kV operating voltage
It allows a bolted, welded or crimped
connection from:
Aluminium conductors to Aluminium
conductors or Aluminium terminals
Aluminium conductors to copper
terminals wherever applicable
Standard capacities:
Al Tube diameter:
100 to 250 mm
Al cable cross section:
75 to 2000 mm
2
Al or Cu stud diameter:
20 to 60 mm
Al or Cu palm:
50, 60, 80, 100, 125, 100x200 mm
or whatever required
Bundle spacing:
100, 200, 400 mm or whatever
required
Connectors are available such as:
conductor ttings
rigid, sliding & expansion busbar
connectors & supports
terminal connectors on stud
or palms
conductors spacers
earthing applications

Connectors for Aluminium conductors & Aluminium or Copper terminals


550 kV Anti-Corona Range
Al. spacer
Al. straight connector Al. Straight compression type terminal pad
Al. straight expansion connector
78
800 kV Connectors for EHV Grids
Connectors for Aluminium conductors & Aluminium or Copper terminals
800 kV Extra High Voltage Connectors
Al. tee connector Al. Straight terminal pad
79
Universal Connectors
Advantages:
Adjustable on site
Easy to install
Controlled tightening (shear head
bolt)
High electrical contact efciency &
stability
Al. UNIVERSAL terminal pad
80
T
r
a
n
s
m
i
s
s
i
o
n
81
Transmission
Tension Insulators 82
Transmission Line Hardware 90
Distribution Line Hardware 96
82
T
e
n
s
i
o
n

I
n
s
u
l
a
t
o
r
s
83
Tension Insulators
Introduction 84
Tension Insulators up to 52 kV 86
Tension Insulators up to 72 kV 88
84
Introduction
Construction
Tyco Electronics Tension Insulators
were built as composite insulators.
They are based on Raychems 30
years experience in the eld of
crosslinked polymers for medium
and high voltage applications. They
consist of a polymeric housing of
ethylene vinyl acetate (EVA) over
pultruded berglass rod to which
galvanized steel or aluminium end
ttings are attached. By molding
directly over the end tting, or by
using a track resistant polyurethane,
moisture ingress to the berglass rod
is prevented.
Composite Insulators are available for
applications up to system voltages of
72 kV. They provide a reliable solution
for power utilities and railway com-
panies with installations in severely
polluted environments all over the
world.
The core of a composite insulator
is a pultruted ber glass rod which
provides a high mechanical strength.
In a direct injection molding process a
non-tracking, erosion and UV resistant
polymeric housing is molded directly
onto the berglass rod. A corrosion
resistant metal tting is crimped
onto each end to the rod to provide
a high mechanical strength. A new
developed crimping control technol-
ogy monitors the assembly process
of the metal ttings and ensures that
crimping forces cause no damage to
the berglass rod while achieving a
crimp that will withstand extremely
high mechanical loads. Sealed with a
tracking and erosion resistant poly-
urethane barrier, the core is protected
from deterioration due to moisture
ingress.
High strength pultruded
ber glass rod
Field proven interfacial sealing
Non tracking, UV resistant
EVA housing
Corrosion resistant crimped
end ttings
85
Application
Composite insulators are available
as tension (suspension), line post
and station post insulators. For
railway applications, tension and strut
composite insulators are available in a
large variety of congurations.
The maintenance free characteristics
of Raychems EVA material have been
demonstrated during service expe-
rience of more than 30 years.
The Tension insulators are qualied to
the requirements of the IEC 61109.
New products up to 230 kV
A range of High Voltage silicone ten-
sion insulators from 69 kV to 230 kV
will be available shortly. These insula-
tors will cover normal, high and extra
pollution levels. They will be available
with a variety of end tting options,
ball, socket, eye, clevis, tongue and
Y-Clevis. They will also available with
corona rings where required.
86
Composite Tension Insulator up to 52 kV
RST-DS46R-xx
General Technical Data
Physical Properties
Creepage Distance [mm] 1300
Dry Arc Distance [mm] 450
Type of Sheds Alternating
Core Diameter [mm] 21

End Fittings
Mechanical Connection Galvanised Steel

Electrical Properties [kV]
AC Wet Withstand Voltage 130
AC Dry Withstand Voltage 148
AC Wet Flashover Voltage 158
AC Dry Flashover Voltage 193
Impulse Withstand Voltage 310
Impulse Flashover Voltage 347

Housing
Color Grey Available on request
Color Red Available on request
RST-DS46R- BS SB CC CC CT CT TC TC TT TT
Physical Properties
Number of
Sheds
13 18 18 13 13 13 13 13 13 13
Housing
Material
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
End Fittings
Top Ball Socket Clevis Clevis Clevis Clevis Tongue Tongue Tongue Tongue
Bottom Socket Ball Clevis Clevis Tongue Tongue Clevis Clevis Tongue Tongue
Orientation N/A N/A parallel perpen-
dicular
parallel perpen-
dicular
parallel perpen-
dicular
parallel perpen-
dicular
Drawing Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Avail-
able on
request
Mechanical Properties [kN]
Specied
Mechanical
Load
120 120 75 75 75 75 75 75 75 75
Routine Test
Load
60 60 37.5 37.5 37.5 37.5 37.5 37.5 37.5 37.5
Drawing Dimensions [mm]
A 650 650 613 613 613 613 650 613 613 613
B 360 360 360 360 360 360 360 360 360 360
C 112.5 112.5 112.5 112.5 112.5 112.5 112.5 112.5 112.5 112.5
D 92 92 92 92 92 92 92 92 92 92
E 28 28 28 28 28 28 28 28 28 28
F 450 450 450 450 447 447 450 450 450 450
Type Specic Technical Data
The Clevis and Tongue ttings can be supplied in any orientation.
The Ball and Socket ttings are according to the IEC 120-16A.
The product range is available in pollution class II and III according to IEC 815.
87
Composite Tension Insulator up to 52 kV
RST-DS46R-xx
Example: RST-DS46R-BS
Top: Ball
Bottom: Socket
End Fittings:
Ball
Socket
Clevis
Tongue
88
Composite Tension Insulator up to 72 kV
RST-DS69R-xx
General Technical Data
Physical Properties
Creepage Distance [mm] 1810
Dry Arc Distance [mm] 610
Type of Sheds Alternating
Number of Sheds 18
Core Diameter [mm] 21
Housing Material Available on request

End Fittings
Mechanical Connection Galvanised Steel
Drawing Available on request

Mechanical Properties [kN]
Specied Mechanical Load 75
Routine Test Load 37.5

Electrical Properties [kV]
AC Wet Withstand Voltage 180
AC Dry Withstand Voltage 180
AC Wet Flashover Voltage 191
AC Dry Flashover Voltage
Impulse Withstand Voltage 350
Impulse Flashover Voltage 434

Housing
Color Grey Available on request
Color Red Available on request
RST-DS69R- BS SB CC CC CT CT TC TC TT TT
End Fittings
Top Ball Socket Clevis Clevis Clevis Clevis Tongue Tongue Tongue Tongue
Bottom Socket Ball Clevis Clevis Tongue Tongue Clevis Clevis Tongue Tongue
Orientation N/A N/A parallel perpen-
dicular
parallel perpen-
dicular
parallel perpen-
dicular
parallel perpen-
dicular
Drawing Dimensions [mm]
A 796 796 759 759 759 759 759 759 759 759
B 510 510 510 510 510 510 510 510 510 510
C 112 112 112 112 112 112 112 112 112 112
D 92 92 92 92 92 92 92 92 92 92
E 28 28 28 28 28 28 28 28 28 28
F 596 596 596 596 596 596 596 596 596 596
Type Specic Technical Data
The Clevis and Tongue ttings can be supplied in any orientation.
The Ball and Socket ttings are according to the IEC 120-16A.
The product range is available in pollution class II and III according to IEC 815.
89
Composite Tension Insulator up to 72 kV
RST-DS69R-xx
Example: RST-DS69R-BS
Top: Ball
Bottom: Socket
End Fittings:
Ball
Socket
Clevis
Tongue
90
H
a
r
d
w
a
r
e

f
o
r
T
r
a
n
s
m
i
s
s
i
o
n

L
i
n
e
s
91
Hardware for Transmission Lines
Introduction, Project Support 92
Vibration Dampers 93
Spacer Dampers and Spacers 93
Pole Hardware 94

Suspension Clamps 95
Dead Ends 95
Compression Fittings 95
92
Introduction Project Support
Tyco Electronics developed Hardware
for Overhead Transmission lines since
over 20 years and has a lot of eld
experience in these products.
On the following pages we present
an overview of our product ranges for
Overhead Transmission Lines.
Spacer Dampers
Vibration Dampers
Spacers
Pole Hardware
Suspension Clamps
Dead Ends
Compression Fittings
With the products on the following
pages we want to give you an over-
view of available product types.
For these product ranges we concern
to work close together with the cus-
tomers on their projects to dene the
right product from the wide product
range. Therefore we do not present
details of the products in this cata-
logue, which are available in different
sizes and materials for a wide range
of applications.
If you are interested in products from
the following pages, please contact
your relevant sales representative. He
will nd together with you the correct
product for your special application.
93
Vibration Dampers
General Recommendations
Vibration dampers are designed to
eliminate conductor fatigue damage
and line maintenance costs by ef-
fectively diminishing aeolian vibra-
tion, thereby allowing increased line
tensions.
All Tyco Electronics damping devices
are designed for the single purpose of
reducing vibration. This unitary func-
tion is entirely different from that of
protecting against: (1) stress concen-
trations, (2) fretting of abrasion and
(3) arc-over burning.
Stockbridge Vibration Dampers Dogbone Vibration Dampers Spiral Vibration Dampers
The Stockbridge vibration dampers
are constructed with a 7 strand mes-
senger cable to improve the damping.
Damper weight and length will be
optimized for maximum efciency.
The Dogbone vibration dampers are
constructed with a 19 strand mes-
senger cable to improve damping
and fatigue performance. The design
of the zinc weights eliminates water
entrapment. The messenger cable has
improved energy dissipation at low
amplitude of exure.
Spiral Vibration Dampers are ex-
ceptionally effective against high
frequency aeolian vibration of EHS or
Alumoweld shield wires.
Spacer Dampers
2 Bundle Posilok Spacer Damper
Spacer Dampers are recommended
for multi-conductor bundles with
industry standard spacing. The Spacer
Damper is designed to withstand
the forces and movements caused
by transient conditions such as short
circuit, differential icing, and wind
loading without either causing dam-
age themselves.
3 Bundle Posilok Spacer Damper
The design accommodates both
longitudinal movement of the subcon-
ductors, vertical sag differences, as
well as compressive and tensile forces.
The Spacer Damper can constitute a
system which replaces conventional
spacers and vibration dampers.
4 Bundle Bolted Spacer Damper
Spacer Dampers will control both
Aeolian vibration and subconductor
oscillation to levels recognized as
acceptable within the industry and to
the customers expressed needs. Tyco
Electronics will tailor the recom-
mendations to terrain and design
parameters.
Posilok Spacer
Posilok spacers are designed to main-
tain specied subconductor spacing.
Furthermore, they are designed to
withstand the forces and movements
caused by transient conditions such
as short circuit differential icing and
wind loading without either causing
damage to the subconductors or
sustaining damage themselves.
The Posilok spacer is exible enough
to allow some longitudinal movement
between subconductors and yet rigid
enough to restrain the subconductors
under adverse conditions. They pro-
vide a smooth, unitized construction
which minimizes corona and presents
a low level of RIV.
94
Pole Hardware
Yoke Plates and Clevis Eyes Ball Clevis Ball Eye Links
Bow Shackles (Anchor Shackles) Ball Clevis Extension Links Ball Eye Extension Links
Ball Hooks Socket Clevis Socket Tongues
D Shackle Socket Clevis Extension Links Clevis Tongues
Clevis Suspension Clamps Trunnion Suspension Clamps Suspension Clamp for Steel and
Copper Conductors
Turnbuckles Aluminium Angle Clamp The devices above are available in
different designs and sizes. Other
devices of pole hardware are available
on request.
For more details please contact your
relevant sales representative.
95
Suspension Clamps
Heliformed Suspension Unit Forged / Cast Bolted Suspension
Clamp
Suspension clamps are designed to
reduce the static stresses at the sup-
port point, as well as insure that the
conductor is cushioned against the
dynamic stresses of aeolian vibration.
They also protect the conductor in
the support area against impulse and
power ashover.
Dead Ends
Wegde Tension Clamp Bolted Tension Clamp
Dead Ends are designed to x the
transmission line at the pole. There
are two possibilities to x the cable
into the Clamp: the wedge and the
bolted solution.
Compression Fittings
Full Tension Fittings
Full Tension Fittings are designed to
hold a minimum of 95% of the specic
conductor breaking load.
Non-Tension Fittings
Non-Tension Fittings are designed to
hold nominally 10% of the conductor
breaking load.
Spacers
Spacers are designed to maintain
conductor separation.
96
H
a
r
d
w
a
r
e

f
o
r
D
i
s
t
r
i
b
u
t
i
o
n

L
i
n
e
s
97
Hardware for Distribution Lines
Ties 98
Splices 98
Armor Rods 98
Line Guards 98
Heliformed Suspension Unit 98
Fiber Optic Dead Ends 99
Optical Tension Device 99
Fiber Optic Suspension Unit 99
98
Ties
To insure proper t and service life, it
is recommended that only insulators
corresponding to C Neck, F Neck, or
J Neck be used. The neck diameters
and groove height dimensions appear
in ANSI Standard for low and medium
voltage pin type insulators and also at
the beginning of each listing.
Ties are recommended as an improve-
ment over Armor Rods secured with
hand tie wire.
Ties are available as:
Longspan Ties
Distribution Ties
Double Support Ties
Side Ties
Double Support Ties
Spool Ties
Quick Spool Ties
Splices
Splices are designed for joining ACSR
or repairing ACSR when damage to
the core is suspected.
Full Tension Splice will hold the full
rated breaking strength and restore
conductivity.
Conductor Splices are designed as a
single component outer layer as-
sembly for sub-EHV conductor. All
conductors, new or weathered, must
be thoroughly scratch brushed until
bright and clean and an inhibitor ap-
plied immediately prior to installation
of the splice.
Armor Rods
Armor Rods are intended to protect
the conductor on which they are
being applied against bending and
compression stresses, abrasion, and
arc-over. The degree of protection
needed on a specic line depends
upon a number of factors such as
line design, temperature, tension,
exposure to wind ow, and vibration
history on similar construction in the
same area.
Armor Rods should be considered
as minimum protection for clamp
style supports of bolted suspension
arrangements.
Armor Rods do not act as vibra-
tion dampers. They are designed to
provide an extra degree of protection
to the conductor at support points.
Line Guards
Line Guards are intended to protect
the conductor against abrasion and
arc-over and to provide repair. The
degree of protection needed on a
specic line depends upon a number
of factors such as line design, tem-
perature, tension, exposure to wind
ow, and vibration history on similar
construction in the same area.
Line Guards are recommended as
minimum for use with hand-tied
spans of less than 300 feet in urban
construction having no experience
of vibration. Line Guards alone are
not recommended for use in areas
of suspected vibration. They are
designed to provide an extra degree
of protection to the conductor at
support points.
Heliformed Suspension Unit
Heliformed suspension is intended
for use on aluminium based conduc-
tors, alumoweld and galvanized steel
strands. They are designed to reduce
the static stresses at the support
point, as well as insure that the
conductor is cushioned against the
dynamic stresses of aeolian vibration.
They also protect the conductor in
the support area against impulse and
power ashover.
Although Heliformed suspension pro-
vides improved protection over armor
clamp or bare clamp attachments, in
the case of known vibration, vibration
dampers will be necessary. Consult
Tyco Electronics for recommenda-
tions concerning Dogbone vibration
dampers.
99
Fiber Optic Dead End
For ADSS cable
Fiber Optic dead ends may be
installed once as a temporary (less
than 30 days) pulling device prior
to its nal installation; as long as it
is not stressed over 50% of its rated
strength.
The dead ends are sold as an assem-
bly including reinforced rods, a dead
end, clevis thimble, extension link and
oval eye nut.
Fiber Optic Dead End
For OPGW cable
The ber optic dead end may be
installed once as a temporary (less
than 30 days) pulling device prior
to its nal installation; as long as it
is not stressed over 50% of its rated
strength. A ground clamp may be
ordered with the dead end. Clamping
over the OPDE or the OPRR assem-
blies is not permitted.
Maximum Rated Holding Strength is
95% of the OPGW RTS.
Optical Tension Device (OTD)
For OPGW Fiber Cable
Tyco Electronics new Optical Tension-
ing Device is designed for pulling
OPGW ber cable to nal sag tension.
Once the nal sag has been achieved,
a permanent type dead end device
should be installed promptly, followed
by the removal of the tensioning
device.
This device should not be subjected
to sag tension for an extended time
period and it should never be utilized
as permanent dead end device.
Fiber Optic Suspension Units
The ber optic xed suspension unit
is a low cost assembly for installing
ADSS cable. The aluminium housing
is joined with stainless steel roll pins,
which ensure positive alignment. The
housing is cushioned on the inside
with an EPDM liner which is specially
sized to provide excellent slip strength
ability and yet not impart any undue
clamping stresses on the cable.
A grounding lug, consisting of a
10 mm aluminium bolt tapped in the
housing, is available as an option.
100
Notes
Energy Division
The Energy Division, a global operating untit of Tyco Electronics
develops manufactures and markets products and systems
for the electrical power industry. Today, the Energy Division
employs approximately 4000 people and annual sales amount
to almost $ 800 million. Our products are extensively employed
by power utilites and equipment manufacturers, in rail transport
systems and in industry around the world.
Tyco Electronics Raychem GmbH,
Energy Division
Finsinger Feld 1
85521 Ottobrunn/Munich, Germany
Phone: +49-89-6089-0
Fax: +49-89-6096345
http://energy.tycoelectronics.com


T
y
c
o

E
l
e
c
t
r
o
n
i
c
s

E
P
P

1
3
8
4

1
2
/
0
7
All of the above information, including drawings, illustrations and graphic designs, reects our present understanding and is to the
best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product
for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance.
Such an assurance is only provided in the context of our product specications or explicit contractual arrangements. Our liability
of these products is set forth in our standard terms and conditions of sale. Raychem, Bowthorpe, Dulmison, Simel, TE logo and
Tyco Electronics are trademarks.