You are on page 1of 6

FORCES DETAILS :

Axial Load = P1 = 25 T
Moment along Major axis = Mx = 5.00 T-m
Moment along Minor axis = Mz = 5 T-m
COLUMN DETAILS : G.L
Length = ( Larger Dimension of Column ) 0.47 m
Width = ( Smaller Dimension of Column ) 0.47 m
FOOTING DETAILS :
Length = L = 2 m
Width = B = 2 m 1.5
Depth = D = 0.5 m
Cover to Main R/f = 0.05 m
Diameter of R/f in Footing = 12 mm
0.5
SOIL DETAILS :
Density of Soil = g = 1.7 T/m
3
Depth of foundation below G.L = H = 2.0 m
X
MATERIAL CONSTANT :
Concrete Grade = M - 20 N/mm
2
R/f Grade = Fe - 415 N/mm
2
2.00
Load Factor = gf = 1.5 Z Z
DESIGN FORCES :
Axial load = P = 25.00 T
Self Weight of Footing = 5.00 T X
Total Vertical Load = 30.00 T
Moment along Major axis 5 T-m
Moment along Minor axis 5 T-m
PRESSURE CALCULATION :
SBC = 20 T/m
2
FOR EARTHQUAKE CONDITION ALLOWABLE S.B.C = 1.25 x 20 = 25 T/m
2
P + Mx + Mz
A - Zx - Zz
\ P
max
= 7.50 + 3.75 + 3.75 = 15.00 T/m
2
< S.B.C SAFE
\ P
min
= 7.50 - 3.75 - 3.75 =
0.00 T/m
2
P =
TENSION NOT CREATED
ISOLATED FOOTING DESIGN
2.00
2.00
R/F CALCULATION FROM BENDING CONSIDERATION :
765
2000 470
765
0.0
T/M
2
15.0
T/M
2
MOMENT AT CRITICAL SECTION ALONG WIDTH :
M = Pmax x 0.765 x 0.765 / 2
M = 4.39 T-m
Mu = 65.84 KN-m
Ast = 413.30 mm
2
( To be distributed in 2 m Length )
Min Req = 600 mm
2
( Ast = 0.12 x b x D )
Required Spacing of Bar = 12 # @ 185 C/C ALONG WIDTH
\ Ast = 753.98 mm
2
2000
470
PROVIDE 12 # @ 150 C/C ALONG WIDTH
MOMENT AT CRITICAL SECTION ALONG LENGTH :
M = Pmax x 0.765 x 0.765 / 2
M = 4.39 T-m
Mu = 65.84 KN-m
Ast = 413.30 mm
2
( To be distributed in 2 m Length )
Min Req = 600 mm
2
( Ast = 0.12 x b x D )
\ Ast = 611.34 mm
2
CHECK FOR ONE WAY SHEAR ALONG LENGTH :
Critical Section is at diatance of ' d ' from face of column
0.765
2.00 0.765 0.315
\ Shear force at critical section = 15.00 x 0.315
V = 4.73 T
Vu
b x d
1.5 x 4.73
1000 x 450
= 0.158 N / mm
2
100 x As 100 x 611.34 Pt tc
b x d 1000 x 450 0.15 0.28
0.2 0.33
\ tc = 0.28 N / mm
2
< tv
Pt = = =
PROVIDE 12 # @ 185 C/C ALONG LENGTH
2.00
\ Actual Shear stress tv =
0.14
HENCE SAFE
= x 10000
CHECK FOR ONE WAY SHEAR ALONG WIDTH :
Critical Section is at diatance of ' d ' from face of column
0.765
2.00 0.765
\ Shear force at critical section = 15.00 x 0.315
V = 4.73 T
Vu
b x d
1.5 x 4.73
1000 x 450
= 0.158 N / mm
2
100 x As 100 x 753.98
b x d 1000 x 450
\ tc = 0.28 N / mm
2
< tv
0.315
2.00
\ Actual Shear stress tv =
= x 10000
Pt = = = 0.17
HENCE SAFE
CHECK FOR TWO WAY SHEAR :
Critical Section is at distance of 'd/2' from face of column
0.92
2.00 0.92 d/2
\ Shear force at Critical Section = 15.00 x Area of Shadeded Portion
= 15.00 x 3.1536
= 47.30 T
Critical Perimeter = 2 x 0.92 + 2 x 0.92
= 3.68 m
Vu
b x d
1.5 x 47.30
3680.00 x 450
= 0.428 N / mm
2
Allowable Shear stress = ks.tc ( CLAUSE 31.3.3 IS 456 : 2000 )
where,
ks = ( 0.5+b )
Short Side of Column = 0.47
Long Side of Column = 0.47
ks = 1.50 but not greater than 1.0
\ Actual Shear stress tv =
= x 10000
b =
= 1.00
2.00
d/2
Where,
tc = 0.25 fck
tc = 0.25 M - 20 = 1.12 N/mm
2
Allowable Shear stress = ks.tc = 1.12 N/mm
2
SAFE
CHECK FOR OVERTURNING :
ALONG LENGTH :
Rm Restoring Moment = 25.00 x 1.00
Rm = 25.00 T.m
Applied Moment = 5.0 T.m
P 25.00
5
> 2.2
SAFE
5.00
1.00
F.O.S. =
Restoring Moment
Applied Moment
= =

You might also like