The design standards of centrifugal pumps are as follows.
1.1 International standard
Pump dimensions and approximate performance
(capacity and total head) of standard pumps are
prov ided.
H orizontal, end
suction single
stage, centerline
discharge design
Specification for
horizontal end suction
centrifugal pumps for
chemical process
A N SI
B 73.1
3
same as A PI 610 ISO 137 09 2
(6) Impeller diameter, ov erhung pumps 3 30 mm
(5) R ated total head 120 m
(4) R otativ e speed 36 00 min
-1
(3) Pumping temp. 150 !
(2) Suction press. 5 b ar
(1) Discharge press. 19 b ar
R elev ant industry operating experience suggests
pumps produced are cost effectiv e when pumping
liq uids at conditions ex ceeding any one of the
following:
O v erhung : 6types
B etween b earings:
5types
V ertically
suspended 7
types
Centrifugal pumps for
petroleum,
petrochemical and
natural gas industries
A PI 610 1
Summary Pump type
A pplication
Standard title
Standard
numb er
N o.
Copyright(C)SotoyamaConsultant
Pump Design Standards
1.2 International standard
It was estab lished for req uirements to centrifugal pump
class !bwith single stage, multistage, horiz ontal or v ertical
(rigidly coupled and closed-coupled) of general use, and
all driv es and installed methods, to standardize, to
rationalize of production and use and to improv e the
q uality. It may b e applied for commercialized pumps.
Single stage,
multistage,
horizontal,
v ertical, closed-
coupled
Technical
specifications for
centrifugal pumps-
Class !b
ISO 990 8
(J IS B
830 9)
7
It was estab lished for req uirements to centrifugal pump
class !awith single stage, horiz ontal or v ertical of general
use, and all driv es and installed methods, to standardize,
to rationalize of production and use and to improv e the
q uality. It may b e applied for chemical pumps.
Single stage,
multistage,
horizontal,
v ertical, closed-
coupled
Technical
specifications for
centrifugal pumps-
Class!a
ISO 519 9
(J IS B
830 8)
6
It was estab lished for req uirements to centrifugal pump
class !`(the sev erest), to standardize, to rationalize of
production and use and to improv e the q uality. It may b e
applied for power generation pumps.
Single stage,
multistage,
horizontal,
v ertical, closed-
coupled
Technical
specifications for
centrifugal pumps-
Class I
ISO 990 5
(J IS B
830 7)
5
Maximum operating rating of 16 b ar. Pump dimensions and
nominal duty points are prov ided.
H orizontal, end
suction single
stage, centerline
discharge design
E nd-suction
centrifugal pumps
(rating 16 b ar) -
Designation, nominal
duty point and
dimensions
ISO 285 8 4
Summary Pump type
A pplication
Standard title
Standard
numb er
N o.
Copyright(C)SotoyamaConsultant
Pump Design Standards
2.1 J IS standard
It was estab lished for general use, centrifugal pumps with
single stage and doub le suction, applied for maximum
working pressure 1.4 MPa and fresh water temperature 0
to 4 0!, and coupled with 5 0H z/6 0H z and 4P/ 6P/ 8P
three-phase induction motor through flex ib le coupliN g on
common b aseplate.
H orizontal, single
stage, doub le
suction v olute
pumps
Doub le suction
v olute pumps
J IS
B 8322
10
It was estab lished for general use, small centrifugal
pumps with multistage (2- 15 stages), applied for
maximum work ing pressure 2.75 MPa and fresh water
temperature 0 to 4 0!, and coupled with 5 0H z/6 0H z and
2P/4P three-phase induction motor through flexib le
coupliN g on common b aseplate.
Small siz e, single
suction multi-
stage centrifugal
pumps
Small siz e multi-
stage centrifugal
pumps
J IS
B 8319
9
It was estab lished for general use, small centrifugal
pumps with single stage and end suction, applied for
maximum work ing pressure 1 MPa and fresh water
temperature 0 to 4 0!, and coupled with 5 0H z/6 0H z and
2P/4P three-phase induction motor through flexib le
coupliN g on common b aseplate.
Small siz e, end
suction centrifugal
pumps
E nd suction
centrifugal pumps
J IS
B 8313
8
Summary Pump type
A pplication
Standard title
Standard
numb er
N o.
Copyright(C)SotoyamaConsultant
Pump Design Standards
2.2 J IS standard
It was estab lished for single suction, centrifugal,
sub mersib le motor pumps for sump, applied for sewage
temperature 0 to 4 5!, pH 5- 9and solids less than 20mm,
suspended in the storage tank or set on it, coupled with
50H z/ 60H z and 2P/ 4P sub mersib le three-phase induction
motor through common shaft or coupliN g.
Single suction,
single stage,
centrifugal,
sub mersib le
motor pumps for
sump
Sub mersib le motor
pumps for sump
J IS
B 8325
13
It was estab lished for single suction, centrifugal or mixed
flow, sub mersib le motor pumps for deep well with b ore
size 20- 20 0mm, suspended on well top or under column
pipe, applied for water temperature 10 to 25! , coupled
with 5 0H z/6 0H z and 2P sub mersib le three-phase
induction motor through coupliN g, and sub merged within
100 m deep.
Single suction,
centrifugal or
mixed flow,
sub mersib le
motor pumps for
deep well
Sub mersib le motor
pumps for deep
well
J IS
B 8324
12
It was estab lished for general use, water ring v acuum
pumps with suction b ore siz e 20- 50 mm, and coupled with
50H z/ 60H z three-phase induction motor through flexib le
coupliN g or V -b elt on common b aseplate.
Water ring
v acuum pumps
Water ring v acuum
pumps
J IS
B 8323
11
Summary Pump type
A pplication
Standard title
Standard
numb er
N o.