You are on page 1of 1

AUTOMATICCONTROLTECHNOLOGY

DeadTimeElement

DL2676

Itallowstheinsertionofan
adjustablerealdeadtimein
thoseprocesseswhichare
characterizedbyit.

Technicalfeatures:
Powersupply:+15V;0V;15V
Signalvoltagerange:10V,...,+10V
ProportionalcoefficientofthemoduleKS=1
DeadtimeTt=10ms....100ms/100ms....1s
Threepositionswitchforcoarsesettingandexclusionof
thedeadtime.
Potentiometerfinesetting.
Ledindicatorsofoverrange.

Itallowsanalyzingthe
behaviourofanelement
withproportionaltransfer
functionabletooscillate,
withadelayofthesecond
order,bothinthetime
domainandinthe
frequencydomain.

Technicalfeatures
Powersupply:+15V;0V;15V
Signalvoltagerange:10V,...,+10V
Gainfactor=1
TimeconstantT=10ms....30s,selectablethroughtwo
rotaryswitches.
Dampingcoefficientd=0....3,withpotentiometersetting.
Resetinputfortherestorationoftheinitialconditions.
Ledindicatorsofoverrange.

Itallowstoclosethe
controlloop,without
oscillations,afterasuitable
settingofthesystem.
Itiscomposedofa
summingpointtowhich
thesignalcomingfroma
potentiometer(manual
mode)andthesignal
comingfromthecontroller
(automaticmode),thatcan
beinsertedthroughswitch,
areconnected.

Technicalfeatures
Powersupply:+15V;0V;15V
Signalvoltagerange:10V,...,+10V
Manualmode/Automaticmodeswitch
Manualmodepotentiometer
Outputsummingpoint.

SecondOrderTransfer
Element

DL2677

Manual/AutomaticSwitch

DL2678