You are on page 1of 10

Calculated value

Dry Material Gs [kg]


Wet Material Ge [kg]
Dried Material Ga [kg]
Evapor. Moisture Gd [kg]
Moisture in Wet Mat. Gwe [kg]
Moisture in Dried Mat. Gwe [kg]

Given value Dry matter Wet Material Dried Material


Gs
Ge
Ga
Gs
Ge

Dry matter Wet Material Dried Material


Gs
Ge
Ga
6.00
6.48
6.48
7.50
7.20
7.21
6.60
6.55
6.55
0.90
0.65
0.66
1.50
0.72
0.72
0.60
0.07
0.07

Initial moisture related to dry Matter


Rezidual moisture related to dry Matter
Rezidual moisture related to wet Material
Initial moisture related to dried Material

Xe= 0.25
Xa=
0.1
Ze= 0.1
Za=
0.01

AF Wet Material =
AF Wet Material Initial Moisture =
AF Dry Matter =
AF Moisture Content =

10.0 t/h
35.0 %
6.5 t/h
3.5 t/h

AF Wet Material Final Moisture =

10.0 %

AF Dried Material =

7.2 t/h

Removed Moisture =
Dry Wood Chip Specific Heat =

2.9 t/h
1.35 J/g/C

Dry Wood Chip Specific Heat =

0.3224 Kcal/kg/C

Enthalpy Liquid Water =


AF Wet Material Temperature =
Dry Bulb Temperature =

1.0 Kcal/Kg/C
20 C
70 C

Heat Required Heat to Warm AF (to dry bulb temperature)=


Required Heat to warm Water (to dry bulb temperature)=

104793.64 Kcal/h
174664.13 Kcal/h

Required Heat to evaporate removed water=

412208.43 Kcal/h

Theoretical Heat Required to Dry Material=

691666.20 Kcal/h

Wall loses Heat=


Heat Loses (Dryer efficiency)

945119.24 Kcal/h
207499.86 Kcal/h

Total heat required to dry Material=

1844285.29 Kcal/h

Heat relese by Cooler exhaustat Air Flow=

1113313.90 Kcal/h

Cooler exhaustat air flow=


Inlet Air Temperature=
Cooler exhaustat air Pressure=
Cooler exhaustat air density=
Cooler exhaustat air flow=
Enthaphy of air at the inlet =

420000.0 Nm3/h
90 C
760.00 mmHg
0.97 Kcal/kg
408263.5 Kg/h
21.63 Kj/kg
5.17 Kcal/kg
8832477.61 Kcal/h
0.01 Kg/Kg(db)
4082.64 Kg/Kg(db)
634.50 Kj/kg
151.55 Kcal/kg
618714.76 Kcal/h

Heat of dry air at the inlet =


Air vapor water flow=
Enthaphy of water vapor at the inlet =
Enthaphy of water vapor at the inlet =
Heat of water vapor at the inlet =

Total Inlet Heat=

9451192.37 Kcal/h

Cooler exhaustat air flow=


Outlet Air Temperature=
Outlet Cooler exhaustat air Pressure=
Outlet Cooler exhaustat air density=
Outlet Cooler exhaustat air flow=
Enthaphy of air at the outlet=
Enthaphy of air at the outlet=
Heat of dry air at the outlet=
Kg Water vapor/Kg dry air =
Air vapor water flow=
Air vapor water flow(evaporated water)=
Enthaphy of water vapor at the inlet =
Enthaphy of water vapor at the inlet =
Heat of water vapor at the inlet =
Total Outlet Heat=

420000.0 Nm3/h
70 C
760.00 mmHg
1.03 Kcal/kg
432058.6 Kg/h
16.82 Kj/kg
4.02 Kcal/kg
7266576.58 Kcal/h
0.01 Kg/Kg(db)
4320.59 Kg/Kg(db)
2850.00 Kg/Kg(db)
625.52 Kj/kg
149.40 Kcal/kg
1071301.89 Kcal/h
8337878.47 Kcal/h

Theoretical Heat Required to Dry

0.998080767 Kcal/g/C
H2OL
H2Ov
70 C
625.52 Kj/kg

10.00%
30.00%

-730971.39 Kcal/h

57.0 %

20 C
19.96 Kj/kg

10.0 t/h
35.0 t/h

Heat relese by Cooler exhaustat

Theoretical Heat Required to Dry Material=


Wall loses Heat=

691666.20 Kcal/h
945119.24 Kcal/h

10.00%

Heat Loses (Dryer efficiency)=

207499.86 Kcal/h

30.00%

Total heat required to dry Wet Material=

1844285.29 Kcal/h

-730971.39 Kcal/h

1113313.90 Kcal/h

Heat relese by Cooler exhaustat Air Flow=

400000.0 Nm3/h
90 C
Relative humidity= 57.0 %

2850.0 Nm3/h
420000.0 Nm3/h
70 C

7.2 t/h
10.0 %