You are on page 1of 5

Procedure for checking combination switch LH lever / FNR lever:

INTERNAL CONTACT DETAILS OF FNR LEVER:

Apparatus needed:
1. Calibrated Digital mulitemeter .

Follow the following process for each function.


When forward/reverse / neutral position is maintained on the lever, check the
respective pins for resistance value. We would get zero resistance and
continuity sound if the contact / function is OK in the switch.

S
R.
N
O
1
2
3
4
5

CHECKING
FUCNTION

RED
TERMINAL

BLACK
TERMINAL

LEVER
POSITI
ON

MULTIMETER
OUTPUT

RESULT

Machine
Forward
Machine
Forward
Machine
Reverse
Machine
Reverse
Machine
Neutral

Connector
pin 1
Connector
pin 1
Connector
pin 1
Connector
pin 1
Connector
pin 1

Connector
pin 6
Connector
pin 6
Connector
pin 4
Connector
pin 4
Connector
pin 5

Forward

0 Ohms

OK

Forward

> 0 ohms

Not OK

Reverse

0 Ohms

OK

Reverse

> 0 ohms

Not OK

Neutral

0 Ohms

OK

Machine
Neutral

Connector
pin 1

Connector
pin 5

Neutral

> 0 ohms

Not OK

You might also like