You are on page 1of 104

ABOUT US:

Abbott Laboratories is a highly diversified global health care company


devoted to the discovery, development, manufacture and marketing of
pharmaceutical, nutritional and medical products, including devices and

diagnostics
With over 70,000 employees worldwide and a global presence in more than
130 countries, Abbott is committed to improving people's lives by providing
cost effective health care products and services that consistently meet the
needs of our customers.
Abbott Pakistan is part of the global healthcare corporation of Abbott
Laboratories, Chicago, USA.
Abbott started operations in Pakistan as a marketing affiliate in 1948; the
company has steadily expanded to comprise a work force of over 1500
employees. Currently two manufacturing facilities located at Landhi and
Korangi in Karachi continue to use innovative technology to produce top
quality pharmaceutical products.
Abbott Pakistan has leadership in the field of Pain Management, Anesthesia,
Medical Nutrition, Anti-Infectives and Diagnostics. Our wide range of products
is managed and marketed through four marketing arms.
The Diagnostic Division operates from its office located at Korangi, Karachi.
With leading products in several key segments of the diagnostic market,
Sales and support staff are available in all the major cities of the country.
A continuous process of innovation, research and development at Abbott's
worldwide facilities enables Abbott Pakistan to offer effective solutions for
various healthcare challenges, with products and services that are well
focused, within the customer's reach and contribute to improved health care
of the people of Pakistan.

PRODUCTS:

Abbutol
Abocain
Abocal
Abozole
Abrifam
Acyclovir
Arinac
Artifen
Atrelax
Becefol
Bejectal
Bevidox

Brufen
Burnol
Calcijex
Cecon
Cofcol
Citro Soda
Cremaffin
Dayalets
Daycor
Dijex
Dobutamine
Enoxabid
Entamizole
Epival
Erybron
Erythrocin
Eryderm
Flexin
Forane
Froben
Ganaton
Gopten
Hytrin
Iberet
Isoptin
Klaricid
Lucrin
Lincomycin
Loftyl
Mammol
Moculator
Mospel
Neophage
Nicor
Optilets-M
Pentothal
Pramet - FA
Prothaiden
Protium
Rambuzid
Rashnil
Reductil
Rondec
Savourane
Selsun

Silliver
Somogel
Sparaxin
Survanta
Surbex
Tarka
Trividox
Tronolane
Urixin
Vancomycin
Vi-Daylin

INTERNSHIP COVER THE


AREA

QUALITY CONTROL
PRODUCTION

Q.C
LABORATORY

THE LAB IS FURTHER DIVIDED INTO:

CONVENTIONAL
LAB
HPLC SECTION

Conventional lab:
DISINTEGRATION TEST.
DISSOLUTION TEST.

WEIGHT UNIFORMATY TEST.


FRIABILITY TEST.
PHYSICAL TEST.
MOISTURE ANALYZER.
PH METER.
OXIDIZABLE TEST.
MELTING POINT.
VISCOSITY TEST.
SPECIFIC GRAVITY.
POLARITY METER.

HPLC SECTION:
HPLC
GC
ATOMIC ABSORPTION TEST.

DISINTEGRATION TEST:
The disintegration test is performed to find out that within how much time the tablet
disintegrates.
The apparatus used for this test is known as disintegration apparatus. It consists of a
glass or plastic tube which is open at one end and the other end is fitted with a rust
proof no. 10 mesh sieve. About 6 tablets are placed in the tube along with a plastic disk
over it, the tube is allowed to move up and down and the time of disintegration is noted
when all the tablets have passed through the sieve.

The disintegration test is a measure of the time required under a given set of conditions
for a group of tablets to disintegrate into particles which will pass through a 10 mesh
screen. Generally, the test is useful as a quality assurance tool for conventional dosage
forms. The disintegration test is carried out using the disintegration tester which consists
of a basket rack holding 6 plastic tubes, open at the top and bottom, the bottom of the
tube is covered by a 10-mesh screen. The basket is immersed in a bath of suitable
liquid held at 37 o C, preferably in a 1L beaker. For compressed uncoated tablets, the
testing fluid is usually water at 37 o C but some monographs direct that simulated gastric
fluid be used. If one or two tablets fail to disintegrate, the test is repeated using 12
tablets. For most uncoated tablets, the BP requires that the tablets disintegrate in
15minutes (although it varies for some uncoated tablets) while for coated tablets, up to
2hours may be required.

DISSOLUTION TEST:
The apparatus used for this test is known as dissolution apparatus. For performing the
test a suitable volume of dissolution medium like distilled water, HCl or phosphate buffer
is filled in the glass vessel which is submerged in the water bath maintained at
370C.The motor is started and the mixer rotates then the tablet is introduced in the
vessel The samples are withdrawn after specified interval and filtered immediately
through a suitable filter medium .The samples are tested by UV spectroscopy for
proportion of drug dissolved. Drug release in the human body can be measured in-vivo
by measuring the plasma or urine concentrations in the subject concerned. However,
there are certain obvious impracticalities involved in employing such techniques on a
routine basis. These difficulties have led to the introduction of official in-vitro tests
which are now rigorously and comprehensively defined in the respective
Pharmacopoeia.

Tablet Dissolution is a standardized method for measuring the rate of drug release from
a dosage form.
The principle function of the dissolution test may be summarized as follows:
Optimization of therapeutic effectiveness during product development and stability
assessment.
Routine assessment of production quality to ensure uniformity between production
lots.
Assessment of bioequivalence, that is to say, production of the same biological
availability from discrete batches of products from one or different manufacturers.
Prediction of in-vivo availability, i.e. bioavailability (where applicable).
Although initially developed for oral dosage forms, the role of the dissolution test has
now been extended to drug release studies on various other forms such as topical and
transdermal systems and suppositories.

APPARATUS:

Baskets - including special polyurethane suppository baskets

Paddles

Shafts

Paddle over Disc (USP Method 5) for Transdermal Delivery Systems

Rotating Cylinder (USP Method 6) alternative for Transdermal Delivery Systems

Special mini cell(vessel) and paddle for transdermal studies of topical


preparations such as liquids, suspensions, gels and ointments

WEIGHT UNIFORMITY TEST:


For carrying out this test generally 10 tablets at random are taken and weighed. The average
weight is calculated, the tablet is weighed individually and weight is noted. The weights of
individual tablets are then compared with the average weight .This test is repeated after short
intervals of time.
The difference between the weight in tablets can lead to variation in dose. Therefore all
the tablets of a batch must confirm to this test. For carrying out this test generally 20
tablets at random are taken and weighed. The average weight is calculated, then each
tablet is weighed individually and weight noted. The weights of individual tablets are
then compared with the average weight already calculated and see that not more than
two tablets fall out side the range. The range is given in STM.

FIRABILITY TEST:

A friable substance is any substance that can be reduced to fibers or finer particles by
the action of comparatively little pressure or friction on its mass, such as inadvertently
brushing up against the substance. The term could also apply to any material that
exhibits these properties.

Friction and shock are the forces that most often cause tablets to chip, cap or break.
The friability test is closely related to tablet hardness and is designed to evaluate the
ability of the tablet to withstand abrasion in packaging, handling and shipping. It is
usually measured by the use of the Roche friabilator. A number of tablets are weighed
and placed in the apparatus where they are exposed to rolling and repeated shocks as
they fall 6 inches in each turn within the apparatus. After four minutes of this treatment
or 100 revolutions, the tablets are weighed and the weight compared with the initial
weight. The loss due to abrasion is a measure of the tablet friability. The value is
expressed as a percentage. A maximum weight loss of not more than 1% of the weight
of the tablets being tested during the friability test is considered generally acceptable
and any broken or smashed tablets are not picked up. Normally, when capping occurs,
friability values are not calculated. A thick tablet may have less tendency to cap whereas
thin tablets of large diameter often show extensive capping, thus indicating that tablets
with greater thickness have reduced internal stress

OXIDIZABLE SUBSTANCES:
We take 100 ml sample in the conical flask, add 10 ml H 2SO4 and some drops of
potassium permanganate and then heat it to boil.
If pink color remains it means that the oxidizable substances are not present, if
disappears then it means that the oxidizable substances are present.

MOISTURE ANALYZER:
VACUUM OVEN:
The classic laboratory method of measuring high level moisture in solid or semi-solid
materials is loss on drying (LOD). In this technique a sample of material is weighed,
heated in an oven at 600C under vacuum for an appropriate period, cooled in the dry
atmosphere of a desiccator, and then reweighed. If the volatile content of the solid is
primarily water, the LOD technique gives a good measure of moisture content.

ELECTRONIC MOISTURE BALANCE:


These analyzers incorporate an electronic balance with a sample tray and surrounding
heating element. Under microprocessor control the sample can be heated rapidly and a
result based on the moisture loss rate is obtained.

KARL FISCHER MOISTURE ANALYSER:


Karl Fischer titration is a classic titration method that is used to determine trace
amounts of water in a sample. It was invented in 1935 by the German chemist Karl
Fischer. The reagent used in titration is methanol.
WORKING PRINCIPLE:
Water react stichiometrically with iodine, producing iodide. While there is still water
present, the iodine is converted to iodide, which is colorless. Once all of the water has
been reacted, the color of the iodine comes through.
ADVANTAGES OF KARL FISCHER MOISTURE ANALYSER:
The popularity of the Karl Fischer titration is due in large part to several practical
advantages that it holds over other methods of moisture determination, including:

High accuracy and precision


Selectivity for water.

Small sample quantities required.

Short analysis duration.

Suitability for analyzing solids, liquids, gases.

Independence of presence of other volatiles.

Suitability for automation.

ASCORBIC ACID:
Vitamin C (ascorbic acid) is an antioxidant that is essential for human nutrition. Vitamin
C deficiency can lead to a disease called scurvy, which is characterized by
abnormalities in the bones and teeth. Many fruits and vegetables contain vitamin C, but
cooking destroys the vitamin, so raw citrus fruits and their juices are the main source of
ascorbic acid for most people.
One way to determine the amount of vitamin C in food is to use a redox titration. The
redox reaction is better than an acid-base titration since there are additional acids in a
juice, but few of them interfere with the oxidation of ascorbic acid by iodine.
Iodine is relatively insoluble, but this can be improved by complexing the iodine with
iodide to form tri iodide:
I2 + I- <--> I3Tri iodide oxidizes vitamin C to form dehydro ascorbic acid:
C6H8O6 + I3- + H2O --> C6H6O6 + 3I- + 2H+
As long as vitamin C is present in the solution, the tri iodide is converted to the iodide
ion very quickly. However, when the all the vitamin C is oxidized, iodine and tri iodide
will be present, which react with starch to form a blue-black complex. The blue-black
color is the endpoint of the titration.
This titration procedure is appropriate for testing the amount of vitamin C in vitamin C
tablets, juices, and fresh, frozen, or packaged fruits and vegetables. The titration can be
performed using just iodine solution and not iodate, but the iodate solution is more
stable and gives a more accurate result.

MELTING POINT TEST:

Melting point analysis is one of the simplest and most useful techniques for the
identification of a chemical substance. A melting point is a characteristic physical
property of a substance. If a chemist is in doubt as to the identity of what he or she has
synthesized, the melting point of the unknown is measured and is compared to
previously published melting points of "candidate" substances. Comparing the melting
point of a newly synthesized substance to the known values of previously characterized
compounds can help determine which of the suspected compounds has been made.

Melting point analysis can also provide information about the purity of a sample. A
substance containing impurities usually melts at a lower temperature than the pure
compound, and melts over a wide range of temperatures. In general, the smaller the
range of melting temperatures, the higher the purity of the sample.

When a melting point analysis is performed, a small amount of sample is first loaded
into a melting point capillary tube, which is then heated in a melting point apparatus until
melting is observed. A melting point capillary tube is a thin glass capillary pipet that has
been sealed closed at one end. The sample needs to be packed at the closed end of
the tube. There are a few technical tricks to doing this - see the interactive walk-through
below.

Once the sample is loaded and packed, you are ready to proceed with melting point
determination by heating the sample in a melting point apparatus. A melting point
apparatus is an electrical device equipped with a thermometer, a magnifying glass, and
heating block with which a hole has been drilled to allow a melting point capillary tube to
be inserted. Such devices can typically heat a sample to at least 500C. We use the
optimelt (automatic melting point system) apparatus in our labs, as it can be loaded with
three tubes at once.
The melting point of a substance is the temperature at which the solid phase converts
to the liquid phase under 1 atmosphere of pressure. The melting point is one of a
number of physical properties of a substance that is useful for characterizing
(describing) and identifying the substance. To measure the melting point of a substance,
it is necessary somehow to gradually heat a small sample of the substance while
monitoring its temperature with a thermometer. The temperature at which liquid is first
seen is the lower end of the melting point range. The temperature at which the last solid
disappears is the upper end of the melting point range. A pure substance normally has a
melting point range no larger than 1-1.5 oC.
Preparing a melting point capillary. A glass capillary tube is normally used to contain
the sample for a melting point determination. Therefore the tube must have one open
end into which the sample can be loaded, and one sealed end so that the capillary will
retain the solid sample. Glass capillary tubes for holding the solid sample are
commercially available.

VISCOSITY TEST:
The viscosity is check by apparatus consist of a rod on which paddle are placed.the
paddle circulate and viscosity is noted from screen.

POLAR METER:
The polarized light passes through the sample tube and exhibits angular rotation to the
left (-) or right (+). On the side opposite the polarizer is the analyzer. Using optics, visual
fields are manually adjusted by the user to measure the optical rotation angle.

In an optical rotation angle polarimeter for investigating optical activity of a test object, a
two-frequency laser source generates a laser beam with two eigen modes of two
different temporal frequencies and two orthogonal linear polarized waves. The laser
beam is to be passed through the test object. The polarized beam splitter is adapted to
receive and split the laser beam, which exits the test object, into first and second
orthogonal optical heterodyne interference X-axis and Y-axis components. Each of first
and second photo detectors receives a respective one of the first and second
orthogonal optical heterodyne interference X-axis and Y-axis components from the
polarized beam splitter, and generates a corresponding optical heterodyne interference
signal. A signal processor is connected to the first and second photo detectors, and
combines the optical heterodyne interference signals therefrom so as to obtain an
optical heterodyne interference output. An amplitude detector detects the amplitude of
the optical heterodyne interference output, which serves as a measure of the optical
activity of the test object. In addition, the laser beam has an adjustable wavelength to
permit measurement of dispersion of optical rotation angles versus wavelength for an
optically active material or substance.
The sample is placed in the glass rod which is present in polar meter. It check the purity
because if there is impurity this will cause change in polarity.

SPECIFIC GRAVITY TEST:


Specific gravity G is defined as the ratio of the weight of an equal volume of distilled
water at that temperature both weights taken in air.

Clean and dry the density bottle


Weigh the empty bottle with stopper (W 1)
Put distilled water in the bottle and again weigh it(W 2).

Again fill the bottle completely with sample put the stopper and weigh it(W 3).

pH METER
A pH meter is an electronic instrument used to measure the pH (acidity or
alkalinity) of a liquid (though special probes are sometimes used to measure the pH of
semi-solid substances). A typical pH meter consists of a special measuring probe (a
glass electrode) connected to an electronic meter that measures and displays the pH
reading

The meter circuit is no more than a voltmeter that displays measurements in pH units
instead of volts. The input impedance of the meter must be very high because of the
high resistance approximately 20 to 1000 M of the glass electrode probes
typically used with pH meters. The circuit of a simple pH meter usually consists of
operational amplifiers in an inverting configuration, with a total voltage gain of about -17.
The inverting amplifier converts the small voltage produced by the probe (+0.059
volt/pH) into pH units, which are then offset by seven volts to give a reading on the pH
scale. For example:

HPLC SECTION
ATOMIC ABSORPTION
SPECTROSCOPY:
Introduction
Atomic absorption spectroscopy (AAS) determines the presence of metals in liquid
samples. Metals include Fe, Cu, Al, Pb, Ca, Zn, Cd and many more. It also measures
the concentrations of metals in the samples. Typical concentrations range in the low
mg/L range.
In their elemental form, metals will absorb ultraviolet light when they are excited by heat.
Each metal has a characteristic wavelength that will be absorbed. The AAS instrument
looks for a particular metal by focusing a beam of uv light at a specific wavelength
through a flame and into a detector. The sample of interest is aspirated into the flame. If
that metal is present in the sample, it will absorb some of the light, thus reducing its
intensity. The instrument measures the change in intensity. A computer data system
converts the change in intensity into an absorbance.
As concentration goes up, absorbance goes up. The researcher can construct a
calibration curve by running standards of various concentrations on the AAS and
observing the absorbances. In this lab, the computer data system will draw the curve for
you! Then samples can be tested and measured against this curve.

Principle
The technique makes use of absorption spectrometry to assess the concentration of an
analyte in a sample. It relies therefore heavily on Beer-Lambert law.
In short, the electrons of the atoms in the atomizer can be promoted to higher orbitals
for a short amount of time by absorbing a set quantity of energy (i.e. light of a given
wavelength). This amount of energy (or wavelength) is specific to a particular electron
transition in a particular element, and in general, each wavelength corresponds to only
one element. This gives the technique its elemental selectivity.
As the quantity of energy (the power) put into the flame is known, and the quantity
remaining at the other side (at the detector) can be measured, it is possible, from Beer-

Lambert law, to calculate how many of these transitions took place, and thus get a
signal that is proportional to the concentration of the element being measured.

Instrument Design
In atomic absorption, there are two methods of adding thermal energy to a sample. A
graphite furnace AAS uses a graphite tube with a strong electric current to heat the
sample. In flame AAS, we aspirate a sample into a flame using a nebulizer. The flame is
lined up in a beam of light of the appropriate wavelength. The flame (thermal energy)
causes the atom to undergo a transition from the ground state to the first excited state.
When the atoms make their transition, they absorb some of the light from the beam. The
more concentrated the solution, the more light energy is absorbed!

The light beam is generated by a lamp that is specific for a target metal. The lamp must
be perfectly aligned so the beam crosses the hottest part of the flame and travels into
the detector. The detector the measures the intensity of the beam of light. When some
of the light is absorbed by a metal, the beam's intensity is reduced. The detector records
that reduction as an absorption. That absorption is shown on a read out by the data
system. The figure above shows the schematic diagram of a flame AAS. As the diagram
indicates, there are four primary parts to the system--the light source, the flame
apparatus, the detector, and the data system.
We can find the concentrations of metals in a sample running a series of calibration
standards through the instrument. The instrument will record the absorption generated
by a given concentration. By plotting the absorption versus the concentrations of the
standards, a calibration curve can be plotted. We can then look at the absorption for a
sample solution and use the calibration curves to determine the concentration in that

Light source
The light source is usually a hollow-cathode lamp of the element that is being
measured. Lasers are also used in research instruments. Since lasers are intense
enough to excite atoms to higher energy levels, they allow AA and atomic fluorescence
measurements in a single instrument. The disadvantage of these narrow-band light
sources is that only one element is measurable at a time.
Hollow cathode lamps
Hollow cathode lamps are the most common radiation source in atomic absorption
spectroscopy. Inside the lamp, filled with argon or neon gas, is a cylindrical metal
cathode containing the metal for excitation, and an anode. When a high voltage is
applied across the anode and cathode, gas particles are ionized. As voltage is
increased, gaseous ions acquire enough energy to eject metal atoms from the cathode.
Some of these atoms are in an excited states and emit light with the frequency
characteristic to the metal. Many modern hollow cathode lamps are selective for several
metals.
Atomizer
AA spectroscopy requires that the analyte atoms be in the gas phase. Ions or atoms in a
sample must undergo desolvation and vaporization in a high-temperature source such
as a flame or graphite furnace. Flame AA can only analyze solutions, while graphite
furnace AA can accept solutions, slurries, or solid samples.
Flame AA uses a slot type burner to increase the path length, and therefore to increase
the total absorbance. Sample solutions are usually aspirated with the gas flow into a
nebulizing/mixing chamber to form small droplets before entering the flame.
The graphite furnace has several advantages over a flame. It is a much more efficient
atomizer than a flame and it can directly accept very small absolute quantities of
sample. It also provides a reducing environment for easily oxidized elements. Samples
are placed directly in the graphite furnace and the furnace is electrically heated in
several steps to dry the sample, ash organic matter, and vaporize the analyte atoms.
Light separation and detection
AA spectrometers use monochromators and detectors for uv and visible light. The main
purpose of the monochromator is to isolate the absorption line from background light
due to interferences. Simple dedicated AA instruments often replace the
monochromator with a bandpass interference filter. Photomultiplier tubes are the most
common detectors for AA spectroscopy.

GAS CHROMATOGRAPHY:
Also known as Vapor Phase Chromatography
A type of chromatography in which the mobile phase is an inert gas. Volatile
components of sample are separated in the column and measured by a detector.
OR
Technique for separating chemical substances in which the sample is carried by a
moving gas stream through a tube packed with a finely divided solid that may be coated
with a film of a liquid is termed as Gas Chromatography .

Working:
Gas Chromatography (GC) is used to separate volatile components of a mixture. A
small amount of the sample to be analyzed is drawn up into a syringe. The syringe
needle is placed into a hot injector port of the gas chromatograph, and the sample is
injected. The injector is set to a temperature higher than the components boiling
points. So, components of the mixture evaporate into the gas phase inside the injector.
A carrier gas, such as helium, flows through the injector and pushes the gaseous
components of the sample onto the GC column. It is within the column that separation
of the components takes place. Molecules partition between the carrier gas (the mobile
phase) and the high boiling liquid (the stationary phase) within the GC column.
After components of the mixture move through the GC column, they reach a detector.
Ideally, components of the mixture will reach the detector at varying times due to
differences in the partitioning between mobile and stationary phases. The detector
sends a signal to the chart recorder which results in a peak on the chart paper. The
area of the peak is proportional to the number of molecules generating the signal.
The main reason why different compounds can be separated this way is the interaction
of the compound with the stationary phase. The stronger the interaction is the longer the
compound remains attached to the stationary phase, and the more time it takes to go
through the column (=longer retention time).

TYPES OF GAS CHROMATOGRAPHY:


Gas chromatography can be divided into two types on the bases of Stationary phase.
Gas Chromatography

Gas Liquid Chromatography


(GLC)

Gas Solid Chromatography


(GSC)

Gas - Liquid Chromatography :


Gas-liquid chromatography (GLC) is a common type of chromatography in which the
mobile phase is a gas (usually helium or nitrogen) and the stationary phase is a
microscopic layer of liquid or polymer on an inert solid support inside a column. It is
used in analytic chemistry for separating and analyzing compounds that can be
vaporized without decomposition.

Gas Solid Chromatography :


Gas-solid chromatography is a chromatography separation technique in which the
mobile phase is a gas (usually helium or nitrogen) and the stationary phase is a suitable
adsorbent such as silica gel, alumina or carbon. The technique is mostly used for the
separation of the permanent gases or the low molecular weight hydrocarbons. Solute
distribution occurs between the gaseous mobile phase (often called the carrier gas) and
the surface of the adsorbent.

INSTRUMENTAL COMPONEMTS:

Carrier gas
The carrier gas must be chemically inert. Commonly used gases include nitrogen,
helium, argon, and carbon dioxide. The choice of carrier gas is often dependant upon
the type of detector which is used. The carrier gas system also contains a molecular
sieve to remove water and other impurities.

Sample injection port


For optimum column efficiency, the sample should not be too large, and should be
introduced into the column in the form of vapour - slow injection of large samples
causes band broadening and loss of resolution. The most common injection method is
where a micro syringe is used to inject sample through a rubber septum into a flash
vaporizer port at the head of the column. The temperature of the sample port is usually
about 50C higher than the boiling point of the least volatile component of the sample.
For packed columns, sample size ranges from tenths of a micro liter up to 20 micro
liters. Capillary columns, on the other hand, need much less sample, typically around
10-3 L.

Columns
There are two general types of column, packed and capillary (also known as open
tubular). Packed columns contain a finely divided, inert, solid support material
(commonly based on diatomaceous earth) coated with liquid stationary phase. Most
packed columns are 1.5 - 10m in length and have an internal diameter of 2 - 4mm.
Capillary columns have an internal diameter of a few tenths of a millimeter. They can be
one of two types; wall-coated open tubular (WCOT) or support-coated open tubular
(SCOT). Wall-coated columns consist of a capillary tube whose walls are coated with
liquid stationary phase. In support-coated columns, the inner wall of the capillary is lined
with a thin layer of support material such as diatomaceous earth, onto which the
stationary phase has been adsorbed. SCOT columns are generally less efficient than
WCOT columns. Both types of capillary column are more efficient than packed columns.
Column temperature
The column(s) in a GC are contained in an oven, the temperature of which is precisely
controlled electronically. (When discussing the "temperature of the column," an analyst
is technically referring to the temperature of the column oven.)
The rate at which a sample passes through the column is directly proportional to the
temperature of the column. The higher the column temperature, the faster the sample

moves through the column. However, the faster a sample moves through the column,
the less it interacts with the stationary phase, and the less the analytes are separated.
Material of Column:

Stainless Steel
Aluminum (Soft material so it is turned easily)

Copper (Soft material so it is turned easily, it is mostly used for circular shape
column)

Glass

Nickel

Adsorbent for Packing of Column:

Silica Gel
Glass Beads

Activated Carbon

Molecular Sieve

Properties of Solid Support:

It should be small and uniform in size.


Inert at high temperature.

Good mechanical strength.

Liquid phase coated uniformly.

Liquid phase coated strongly.

Properties of Liquid phase.

High thermal stability.


Low thermal reactivity.

Low vapour pressure at high temperature.

Detectors

There are many detectors which can be used in gas chromatography.


Commonly used detectors are;

Mass Spectrometer (GC/MS)


Many GC instruments are coupled with a mass spectrometer, which is a very
good combination. The GC separates the compounds from each other, while the
mass spectrometer helps to identify them based on their fragmentation pattern.

Flame Ionization Detector (FID)


The detector is very sensitive towards organic molecules (10 -12 g/s, linear range:
106 107), but relative insensitive to a few small molecules e.g. N 2, NOx, H2S, CO,
CO2, H2O. If proper amounts of hydrogen/air are mixed, the combustion does not
afford any ions. If other components are introduced that contain carbon atoms
cations are produced in the effluent stream. The more carbon atoms are in the
molecule, the more fragments are formed and the more sensitive the detector is
for this compound (-- > response factor). However, due to the fact that the
sample is burnt (pyrolysis), this technique is not suitable for preparative GC. In
addition, several gases are usually required to operate a FID: hydrogen, oxygen
(compressed air), and carrier gas.

Thermal Conductivity Detector (TCD)


This detector is less sensitive than the FID (10-5-10-6g/s, linear range: 103-104),
but is well suited for preparative applications, because the sample is not
destroyed. It is based on the comparison of two gas streams, one containing only
the carrier gas, the other one the carrier gas and the compound. Naturally, a
carrier gas with a high thermal conductivity e.g. helium or hydrogen is used in
order to maximize the temperature difference (and therefore the difference in
resistance) between two thin tungsten wires. The large surface-to-mass ratio
permits a fast equilibration to a steady state. The temperature difference between
the reference cell and the sample cell filaments is monitored by a Wheatstone
bridge circuit.

Electron Capture Detector (ECD)


The detector consists of a cavity that contains two electrodes and a radiation
source that emits b-radiation (e.g. 63Ni, 3H). The collision between electrons and
the carrier gas (methane plus an inert gas) produces a plasma containing
electrons and positive ions. If a compound is present that contains
electronegative atoms, those electrons are captured and negative ions are
formed, and the rate of electron collection decreases. The detector is extremely
selective for compounds with atoms of high electron affinity (10 -14 g/s), but has a
relatively small linear range (~102-103). This detector is frequently used in the
analysis of chlorinated compounds e.g. pesticides, polychlorinated biphenyls,

which show are very high sensitivity.

Data reduction and analysis:

Qualitative analysis:
Generally chromatographic data is presented as a graph of detector response (y-axis)
against retention time (x-axis), which is called a chromatogram. This provides a
spectrum of peaks for a sample representing the analytes present in a sample eluting
from the column at different times. Retention time can be used to identify analytes if the
method conditions are constant.
Quantitative analysis:
The area under a peak is proportional to the amount of analyte present in the
chromatogram. By calculating the area of the peak using the mathematical function of
integration, the concentration of an analyte in the original sample can be determined

FACTORS INFLUENCE SEPERATION:


Polarity of the stationary phase
Polar compounds interact strongly with a polar stationary phase, hence have
a longer retention time than non-polar columns.
Temperature
The higher the temperature, the more of the compound is in the gas phase. It
does interact less with the stationary phase, hence the retention time is
shorter, but the quality of separation deteriorates.
Carrier gas flow
If the carrier gas flow is high, the molecules do not have a chance to interact
with the stationary phase. The result is the same as above.
Column length
The longer the column is the better the separation usually is. The trade-off is
that the retention time increases proportionally to the column length. There is
also a significant broadening of peaks observed, because of increased back
diffusion inside the column.

Amount of material injected


If too much of the sample is injected, the peaks show a significant tailing,
which causes a poorer separation. Most detectors are relatively sensitive and
do not need a lot of material (see below).
Conclusion
High temperatures and high flow rates decrease the retention time, but also
deteriorate the quality of the separation.
USES OF GAS CHROMATOGRAPHY:

Testing the purity of a particular substance.


Separating the different components of a mixture (the relative amounts of such
components can also be determined).

In some situations, GC may help in identifying a compound.

In preparative chromatography, GC can be used to prepare pure compounds


from a mixture.

HIGH PERFORMANCE LIQUID


CHROMATOGRAPHY - HPLC
HPLC is a popular method of analysis because it is easy to learn and use and is not
limited by the volatility or stability of the sample compound. Modern HPLC has many
applications including separation, identification, purification, and quantification of various
compounds.
High performance liquid chromatography is basically a highly improved form of column
chromatography. Instead of a solvent being allowed to drip through a column under
gravity, it is forced through under high pressures of up to 400 atmospheres. That makes
it much faster.
It also allows us to use a very much smaller particle size for the column packing
material which gives a much greater surface area for interactions between the stationary

phase and the molecules flowing past it. This allows a much better separation of the
components of the mixture.
The other major improvement over column chromatography concerns the detection
methods which can be used. These methods are highly automated and extremely
sensitive.

The column and the solvent


Confusingly, there are two variants in use in HPLC depending on the relative polarity of
the solvent and the stationary phase.
Normal phase HPLC
This is essentially just the same as you will already have read about in thin layer
chromatography or column chromatography. Although it is described as "normal", it isn't
the most commonly used form of HPLC.
The column is filled with tiny silica particles, and the solvent is non-polar - hexane, for
example. A typical column has an internal diameter of 4.6 mm (and may be less than
that), and a length of 150 to 250 mm.
Polar compounds in the mixture being passed through the column will stick longer to the
polar silica than non-polar compounds will. The non-polar ones will therefore pass more
quickly through the column.
Reversed phase HPLC
In this case, the column size is the same, but the silica is modified to make it non-polar
by attaching long hydrocarbon chains to its surface - typically with either 8 or 18 carbon
atoms in them. A polar solvent is used - for example, a mixture of water and an alcohol
such as methanol.
In this case, there will be a strong attraction between the polar solvent and polar
molecules in the mixture being passed through the column. There won't be as much
attraction between the hydrocarbon chains attached to the silica (the stationary phase)

and the polar molecules in the solution. Polar molecules in the mixture will therefore
spend most of their time moving with the solvent.
Non-polar compounds in the mixture will tend to form attractions with the hydrocarbon
groups because of van der Waals dispersion forces. They will also be less soluble in the
solvent because of the need to break hydrogen bonds as they squeeze in between the
water or methanol molecules, for example. They therefore spend less time in solution in
the solvent and this will slow them down on their way through the column.
That means that now it is the polar molecules that will travel through the column more
quickly.
Reversed phase HPLC is the most commonly used form of HPLC.

Injection of the sample


Injection of the sample is entirely automated, and you wouldn't be expected to know
how this is done at this introductory level. Because of the pressures involved, it is not
the same as in gas chromatography (if you have already studied that).
Retention time
The time taken for a particular compound to travel through the column to the detector is
known as its retention time. This time is measured from the time at which the sample is

injected to the point at which the display shows a maximum peak height for that
compound.
Different compounds have different retention times. For a particular compound, the
retention time will vary depending on:

the pressure used (because that affects the flow rate of the solvent)
the nature of the stationary phase (not only what material it is made of, but also
particle size)

the exact composition of the solvent

the temperature of the column

That means that conditions have to be carefully controlled if you are using retention
times as a way of identifying compounds.

The detector
There are several ways of detecting when a substance has passed through the column.
A common method which is easy to explain uses ultra-violet absorption.
Many organic compounds absorb UV light of various wavelengths. If you have a beam
of UV light shining through the stream of liquid coming out of the column, and a UV
detector on the opposite side of the stream, you can get a direct reading of how much of
the light is absorbed.
The amount of light absorbed will depend on the amount of a particular compound that
is passing through the beam at the time.

You might wonder why the solvents used don't absorb UV light. They do! But different
compounds absorb most strongly in different parts of the UV spectrum.

Interpreting the output from the detector


The output will be recorded as a series of peaks - each one representing a compound in
the mixture passing through the detector and absorbing UV light. As long as you were
careful to control the conditions on the column, you could use the retention times to help
to identify the compounds present - provided, of course, that you (or somebody else)
had already measured them for pure samples of the various compounds under those
identical conditions.
But you can also use the peaks as a way of measuring the quantities of the compounds
present. Let's suppose that you are interested in a particular compound, X.
If you injected a solution containing a known amount of pure X into the machine, not
only could you record its retention time, but you could also relate the amount of X to the
peak that was formed.
The area under the peak is proportional to the amount of X which has passed the
detector, and this area can be calculated automatically by the computer linked to the
display. The area it would measure is shown in green in the (very simplified) diagram.

If the solution of X was less concentrated, the area under the peak would be less although the retention time will still be the same. For example:

This means that it is possible to calibrate the machine so that it can be used to find how
much of a substance is present - even in very small quantities.
Be careful, though! If you had two different substances in the mixture (X and Y) could
you say anything about their relative amounts? Not if you were using UV absorption as
your detection method.

In the diagram, the area under the peak for Y is less than that for X. That may be
because there is less Y than X, but it could equally well be because Y absorbs UV light
at the wavelength you are using less than X does. There might be large quantities of Y
present, but if it only absorbed weakly, it would only give a small peak.

SEMI-SOLID MANUFACTORING:
PRODUCTS NAME:

Artifen Gel
Brufen cream
Froben Gel
Somo Gel
Rashnil Cream
Tronolane Cream

(a) ARTIFEN GEL:


1g. Artifen gel contains an amount of Diclofenac Diethylammonium equivalent to
active substance diclofenac 10mg. (1%).
(b)

BRUFEN CREAM:

.
Per 100g the active ingredient ibuprofen 10gm is used.

(c) FROBEN GEL:

Per 100gm, the active ingredient used is Fluriprofen 5gm.

(d) SOMO GEL:


Lignocaine (Base)
Menthol
Eucalyptol
Cetylpyridinium chloride
Ethanol

0.60% w/w
0.06% w/w
0.10% v/w
0.02% w/w
33% v/w

(e) RASHNIL CREAM:


Benzalkonium Chloride 0.1% w/w
Zinc Oxide 8.5% w/w

(f) TRONOLANE CREAM:


Each 20gm contains pramoxine hydrochloride.

INTRODUCTION:
Transdermal drug delivery system delivers drug systematically through the skin but
without the use of any instrument to inject them. The system is applied to the skin and is
absorbed by a process of molecular diffusion. The diffusion process begins as soon the
system is applied to the skin. In the beginning the process is quite fast till the binding
sites of the skin are saturated then the release of drug settles at a constant rate.
Semi-solid includes ointments, creams, gels, clear gels and pastes. They may serve as
vehicles for topically applied drugs, as emollients, or as protective or occlusive
dressings on the skin.

TYPES OF SEMI-SOLID:
(a) Ointments.
These are soft, semi-solid preparations intended for application to the skin and
may consist of hard and soft paraffins, vegetable oils, synthetic esters of fatty acids,
animal fats and many other materials. These substances may be used singly or in
multiple combinations, with the incorporation of medicaments and sometimes surface
active agents.
Properties which affect choice of an ointment base are:

1. Stability
2. Penetrability
3. Solvent property
4. Irritant effects
5. Ease of application and removal
Methods of preparation of ointments:

Trituration: In this finely subdivided insoluble medicaments are evenly


distributed by grinding with a small amount of the base followed by dilution with
gradually increasing amounts of the base.
Fusion: In this method the ingredients are melted together in descending order
of their melting points and stirred to ensure homogeneity.

(b) Creams.
These are viscous semi-solid emulsions for external use and may be oil in water
(o/w) i.e. non-greasy, or water in oil (w/o) i.e. greasy. Emulsifying agents for o/w
creams include monovalent inorganic and organic soaps and anionic, cationic and nonionic emulsifying waxes. Those for w/o creams include wool fat, wool alcohols,
combinations of beeswax and borax, calcium soaps and surfactants of low H.L.B.
Creams are able to support the growth of micro-organisms, and it is therefore
necessary to use preservatives in most systems. Accidental contamination will almost
certainly occur during bench scale manufacture, but good technique can keep this to a
minimum. All apparatus and final containers should be thoroughly cleansed before use
and purified water should be used in the preparation of products.
Uses of creams

The provision of a barrier to protect the skin. This may be a physical barrier or a
chemical barrier as with sunscreens
To aid in the retention of moisture (especially water-in-oil creams)

Cleansing

Emollient effects

As a vehicle for drug substances such as local anaesthetics, anti-inflammatories


(NSAIDs or corticosteroids), hormones, antibiotics, antifungals or counterirritants.

(c)Gels.
Gels encompass semi-solids with a wide range of characteristics. They can be
considered as being composed of two interpenetrating phases. In simplistic terms they

fall into two major classes; suspensions of small inorganic particles or large organic
molecules interpenetrated with liquid.
(d) Clear gels.
Clear gels are microemulsions in which the diameter of the dispersed phase
globules is in the range of 10 to 60 nm. These emulsions are thermodynamically stable.
Microemulsions are transparent as the globule diameter of the disperse phase is less
than the wavelength of light. Microemulsions can be distinguished from other types of
gels by the vibrations or ringing that occurs when the emulsion is subjected to impact.

(e) Pastes.
These are semi-solid preparations containing large proportions of solids finely
dispersed in the basis. They are usually intended to be applied to small localised areas
of the skin. Pastes should be stored at temperature not exceeding 25 0C unless
otherwise stated. Pastes are used principally as antiseptic, protective or soothing
dressings. Their consistency is much stiffer than that of ointments and so they are
usually spread on gauze or lint before being applied.

PERPARATION OF SEMI SOLID:


These are following step for the preparation of semi-solids.
Line clearance
Dispensing/Warehouse section
Mixing section
Filling section
Packaging section
PCI i.e Production Control Inspector.

LINE CLEARENCE:
Line clearance is check by worker, supervisor as well as PCI i.e Production Control
Inspector.
The line clearance include following steps:
Check pressure, temperature as per SOP requirement.
Check gas protection where required.
Check the equipment/area is cleaned.
Check no identity sign from previous batch.
Check required commodities of the batch area available as per finishing shop
order.
Check exhaust are operational in powder filling.
Check product name and strength on almonium foil.

DISPENSING/WARE HOUSE SECTION:


In this section following step is done:
The raw material is collected as per STM or as define in direction.
The weighing of raw material is done under control environment with proper
labeling.

MIXING SECTION:
In mixing section the mixing of different phases occur that is define in direction.
For example in cream there are two phases one is aqueous while other is alcoholic.
These two phases are prepared in different chamber with different condition that are
define in direction. Then these phases are mixed together.
In mixing section we have following equipments that are defined below.
Batch reactor.
Silverson mixer.
Storage tank.

BATCH REACTOR:
Within the chemical and pharmaceutical industries, external cooling jackets are
generally preferred as they make the vessel easier to clean. The performance of these
jackets can be defined by 3 parameters:

Response time to modify the jacket temperature


Uniformity of jacket temperature

Stability of jacket temperature

A chemical reactor in which the reactants and catalyst are introduced in the desired
quantities and the vessel is then closed to the delivery of additional material.
The Batch reactor is the generic term for a type of vessel widely used in the
process industries. Vessels of this type are used for a variety of process operations
such as solids dissolution, product mixing, chemical reactions, batch distillation,
crystallization, liquid/liquid extraction and polymerization.

A typical batch reactor consists of a tank with an agitator and integral heating/cooling
system. These vessels may vary in size from less than 1 litre to more than 15,000 litres.
They are usually fabricated in, stainless steel. Liquids and solids are usually charged via
connections in the top cover of the reactor. Vapors and gases also discharge through
connections in the top. Liquids are usually discharged out of the bottom.
The advantages of the batch reactor lie with its versatility. A single vessel can carry out
a sequence of different operations without the need to break containment. This is
particularly useful when
processing, toxic or highly
potent compounds.

Agitation

The usual agitator arrangement is a centrally mounted driveshaft with an overhead drive
unit. Impeller blades are mounted on the shaft. A wide variety of blade designs are used
and typically the blades cover about two thirds of the diameter of the reactor. Where
viscous products are handled, anchor shaped paddles are often used which have a
close clearance between the blade and the vessel walls.

With propeller scrapper is also introduce in reactor because of the fact that cream, gel
e.t.c are very viscous in nature and hence need scrapper for efficient mixing. Most batch
reactors also use baffles. These are stationary blades which break up flow caused by
the rotating agitator. These may be fixed to the vessel cover or mounted on the side
walls.
Despite significant improvements in agitator blade and baffle design, mixing in large
batch reactors is ultimately constrained by the amount of energy that can be applied. On
large vessels, mixing energies of more than 5 Watts per litre can put an unacceptable
burden on the cooling system. High agitator loads can also create shaft stability
problems. Where mixing is a critical parameter, the batch reactor is not the ideal
solution. Much higher mixing rates can be achieved by using smaller flowing systems
with high speed agitators, scrapper, ultrasonic mixing or static mixers.

Heat cooling systems

Products within batch reactors usually liberate or absorb heat during processing. Even
the action of stirring stored liquids generates heat. In order to hold the reactor contents
at the desired temperature, heat has to be added or removed by a cooling jacket or
cooling pipe. Heating/cooling coils or external jackets are used for heating and cooling
batch reactors. Heat transfer fluid passes through the jacket or coils to add or remove
heat.
It can be argued that heat transfer coefficient is also an important parameter. It has to
be recognized however that large batch reactors with external cooling jackets have
severe heat transfer constraints by virtue of design. It is difficult to achieve better than
100 Watts/litre even with ideal heat transfer conditions. By contrast, continuous reactors
can deliver cooling capacities in excess of 10,000 W/litre. For processes with very high
heat loads, there are better solutions than batch reactors.
Fast temperature control response and uniform jacket heating and cooling is particularly
important for crystallization processes or operations where the product or process is
very temperature sensitive. There are several types of batch reactor cooling jackets:

Single external jacket

The single jacket design consists of an outer jacket which surrounds the vessel. Heat
transfer fluid flows around the jacket and is injected at high velocity via nozzles. The
temperature in the jacket is regulated to control heating or cooling.
The single jacket is probably the oldest design of external cooling jacket. Despite being
a tried and tested solution, it has some limitations. On large vessels, it can take many
minutes to adjust the temperature of the fluid in the cooling jacket. This results in
sluggish temperature control. The distribution of heat transfer fluid is also far from ideal
and the heating or cooling tends to vary between the side walls and bottom dish.
Another issue to consider is the inlet temperature of the heat transfer fluid which can
oscillate (in response to the temperature control valve) over a wide temperature range
to cause hot or cold spots at the jacket inlet points.

CAPACITY:
There are three type of capacities used in Abbott.

400kg
800kg

1000kg

STORAGE TANK:
Storage vessels/tanks are simple vessels used for storing liquids, solutions or
pharmaceutical raw material and other chemicals. These general purpose vessels are
made of stainless steel, fibre glass, titanium, galvanized steel etc. and are used by a
number of industries to store various substances and solutions. Storage tanks/vessels
can either be horizontal or vertical in their orientation. Horizontal storage vessel is
generally mounted on stands or saddles and have an access port either at the bottom or
at the top. Vertical storage tanks are erected vertically and have access ports at bottom.
These specialized tanks can either be placed above or underground, depending on the
construction of the storage facility. The thickness of wall of these tanks/vessels also
determine their application or use; while single wall storage tanks can be used for

general application, double walled tanks/vessel are used for high pressure
considerations.

SILVERSON MIXER:

In pharmaceutical industry, Silverson has In-Line mixers, top and bottom entry
immersion/batch mixers and powder/liquid mixing systems.
Silverson High Shear Bottom Entry Mixers are increasingly being specified by the
pharmaceutical sector for applications where focused high shear in-tank mixing is
required. Using their expertise in the design and manufacture of Ultra Hygienic In-Line
and top entry batch mixers, Silverson have advanced their range of Bottom Entry mixers
incorporating specific features, for example minimized number of product contact parts,
"crevice-free" design, electro-polished finish, and special hygienic shaft seals. Complete
documentation packages and data manuals including IQ/OQ documentation to comply
with FDA and GMP requirements can also be supplied.
These mixers can be used in conjunction with slow speed stirrer/scraper units, the
action of the two being complementary to one another, the Silverson rotor/stator work
head providing high shear which stirrer/scraper units cannot impart. The stirrer/scraper
unit complements this action by distributing the homogenized output of the bottom entry
mixer uniformly throughout the vessel. This combination is ideal for high viscosity
products, those that increase in viscosity on cooling - for example, pharmaceutical
creams and ointments - and where heat sensitive materials such as active ingredients
may only be added at low temperatures.

FILLING SECTION:
The filling is done by two machine named kali having capacity

Kali having 1000 kg


Unipack having 400kg

There is no contamination occur in the tube by supplying air as well as


simultaneously supplying vacuum in the same tube.
There is also a sensor present that locate the direction where expire date, batch
number is printed. The cream or gel is filled and simultaneously sealed by the
machine.
The tube filling, crimping and coding machine is sturdy compact in design and
simple in operation. It consists of an aluminium-rotating disc with interchangeable
tube holding sockets for different tube sizes.
The filling station is made of SS Block, fitted with pneumatic device to control tailing.
No tube no fill process switches. (Electronic counter provided if required, not
included in basic machine) S.S plain hopper of 25 kg capacity.

KALI FILLING MACHINE


FEATURE:

All contact parts easily detachable for cleaning and sterilization.


Thermostatically controlled jacketed heater with stirrer.
All operations are automatic except loading of the containers on the
turntable.
No need of costlier spares as in the case of ultrasonic sealing machines with
heaters.
Fill accuracy: + 98.8 %.
Accurate tail cutting arrangement.
PLC controlled alarm for any abnormal performance during filling operation.
Output up to 70+ Tubes/minute.
Can fill from 3 Grams to 500 Grams with change parts. (Change parts
available on request)
GMP model contact parts SS 304 / SS 316 (As per customer requirement).
Power consumption 0.75 HP, 230 Volts / 415 Volts.
Sensors embedded in hopper to stop overflowing and also pause machine in
case of low level of cream to avoid tube wastage.

UNIPACK FILLING MACHINE:


FEATURES:

Fully pneumatic and 95% maintenance free.

Tube holders are of spring loaded type to take care of any


tube diameter variation.
Output up to 50 - 55 Tubes/minute.

Can fill from 3 Grams to 500 Grams with change parts.

GMP model contact parts SS 304 / SS 316 (As per customer


requirement).
Power consumption 0.75 HP, 230 Volts / 415 Volts.

It is fully automatic.

Production counters with memory to indicate the number of


filled tubes.
Tube orientation device incorporating photo sensors and
stepper motor and controller. (optional)
Automatic cream level sensing device. (optional

PACKAGING AREA:
In packaging area the tubes are packed in cartons and then LOCPS.
Then it is marketed.

PRODUCTION COTROL INSPECTOR:


The PCI check the following test during production

Check FO i.e expiry slip and batch number on the tube.


To check line clearance.
Take three empty tubes marked them and filled them with cream by machine and
then perform weight uniformity and leak test by applying 500mm of Hg pressure
for 3-4 hr.

LIQUID MANUFACTORING:
PRODUCT NAME:

Iberet drop.
Vidaylin drop.
Rondec-D drop.
Cecon solution.
Silver suspension.
Vidaylin syrup.
Surbex syrup.
Rondec-C syrup.
Iberet solution.
Vidaylin-L syrup
Epival syrup.

1.

IBERETDROPS

Per ml : Ferrous sulphate 125mg (represents 25 mg of elemental iron


The liquid department is divided into five sections:

2.

VI-DAYLIN DROPS
Each 0.6 ml of Vi-Daylin Drops contains:

Vitamin A

1.5 mg or 5000 IU

Vitamin D

10 mcg or 400 IU

Vitamin B1

1.5 mg

Vitamin B2

1.2 mg

Vitamin B6

0.5 mg

Vitamin C

50 mg

Nicotinamide

10 mg

in citrus flavour with a calibrated dropper

3.

VIDAYLIN-L SYRUP
Each 5 ml teaspoonful of ViDaylin-L Syrup contains:

Vitamin A

0.9 mg or 3000 IU

Vitamin D

10 mcg or 400 IU

Vitamin B1

1.5 mg

Vitamin B2

1.2 mg

Vitamin B6

1.0 mg

Vitamin B12

3 mcg

Vitamin C

50 mg

Nicotinamide

10 mg

Choline

5 mg

Inositol

5 mg

Lysine

300 mg

Monohydrochloride

4.

VI-DAYLIN SYRUP
Each 5 ml teaspoonful of Vi-Daylin Syrup contains:

Vitamin A

0.9 mg or 3000 IU

Vitamin D

10 mcg or 400 IU

Vitamin B1

1.5 mg

Vitamin B2

1.2 mg

Vitamin B6

1.0 mg

Vitamin B12

3 mcg

Vitamin C

50 mg

Nicotinamide

10 mg

in delicious lemon candy flavor

5.

CECON DROP:
Each ml. contains 100 mg of vitamin C in a vehicle of propylene glycol

6.

RONDEC SYRUP
Each teaspoonful (5ml.) provides:

Dextromethorphan hydrobromide......10 mg
Chlorpheniramine maleate ...........2 mg
Ephedrine hydrochloride ............5 mg
Phenylephrine hydrochloride ........5 mg
Ammonium chloride ..................40 mg
7.

RONDEC C SYRUP
Each teaspoonful (5ml.) provides:

Dextromethorphan HBr ...........7.5 mg


Carbinoxamine maleate ..........1.25 mg
Pseudoephedrine HCl ............30 mg
Guaifenesin ....................50 mg
Ipecac fluid extract ...............0.005 ml
8.

RONDEC D ORAL DROPS


Each dropperful (1ml.) contains:

Carbinoxamine maleate 1.0 mg


Pseudoephedrine HCl 30 mg

9.

SILLIVER
Silymarin 200mg

10.

SURBEX SYRUP
Each 5 mL of Surbex Syrup contains the following ingredients:

Vitamin C (as Ascorbic acid) 100 mg


Nicotinamide

50 mg

Vitamin B1

10 mg

Vitamin B2

6 mg

Pantothenol

10 mg

Vitamin B6

10 mg

Vitamin B12

10 mcg

11.

IBERET-500LIQUID
BERET-500 Liquid: Per 5ml: Ferrous sulphate 131 mg (represents 26.25mg of
elemental iron), Vit C 125mg, B1 1.5mg, B2 1.5mg, B6 1.25mg, B12 6.25mcg,
Nicotinamide 7.5mg and Dexpanthenol 2.5mg

PREPARATION OF LIQUID:
The area is further divided into following:
1. Syrup manufacturing.
2. Pedialyte manufacturing area.
3. GHC (general health care) production area.

SYRUP MANUFACTURING AREA:

INTRODUCTION OF SYRUP:
Syrup is a concentrated or nearly saturated solution of sucrose in water. Simple syrup
contains only sucrose and purified water (e.g. syrup USP). Syrup containing pleasantly
flavored substances is known as flavoring syrup (e.g. Cherry syrup, Acacia syrup,
etc).medicinal syrups are those to which therapeutic compounds have been added (e.g.
cough syrup).
Syrup USP contains 850 gm sucrose and 450 gm of water in each liters of syrup.
Although very concentrated the syrup is not saturated. Since 1 gm sucrose dissolves in
0.5 ml of water, only 425 ml of water would be required to dissolve 850 gm sucrose.
This slight excess of water enhances the syrups stability over a range of temperatures,
permitting cold storage without crystallization.
This high solubility of sucrose indicates a high degree of hydration or hydrogen bonding
between sucrose and water. This association limits the further association between
water and additional solutes. Hence, syrup has a lower power than water and salting
out may be a problem.

PRESERVATION OF SYRUPS:
Syrup, USP is protected from bacterial contamination by virtue of its high solute
concentration. More dilute syrups are good media for microbial growth and require the
addition of some preservatives. Industrially formulated syrups often contain ingredients
to improve solubility, stability, taste or appearance which also contribute to product
preservation. It is necessary from an economical point of view to consider the additives
preservative effect of such ingredients as alcohol, glycerin, propylene glycol and other
dissolve solids. Syrup USP having a specific gravity of 1.313 and a concentration of
85% w/v is a 65% w/w solution. This 65 % w/w is the minimum amount of sucrose, the

quantity of alcohol, or other preservatives, may be estimated by considering the USP


syrup equivalent and the free water equivalent. One may assume that free water is
preserved by 18% alcohol

PREPARATION OF SYRUP
For manufacturing of syrup Abbott manufacturers have to follow.
Manufacturing order.
Manufacturing direction.
In Manufacturing order there is a demand that of how much quantity a batch
must have to prepare and all the quantities of raw materials are provided so
according to this the production demands raw materials from the quarantine
section, and at what date this has to be sent to the finishing area i.e. for
filling and packing.
In Manufacturing direction there provided the steps by using a product can be
manufactured in this direction conditions of temperature and pressure
ranges also provided.

Steps for the preparation of syrup are:

Line clearance.
Dispensing.
Preparation of sugar base solution.
Preparation of saturated water.
Final preparation of syrup.
Storage syrup.
Washing of bottles.
Filling of bottles
PCI:

LINE CLEARENCE:

Line clearance is check by worker, supervisor as well as PCI i.e Production


Control Inspector. The line clearance include following steps:

Check pressure, temperature as per SOP requirement.


Check gas protection where required.
Check the equipment/area is cleaned.
Check no identity sign from previous batch.
Check required commodities of the batch area available as per finishing shop
order.
Check exhaust are operational in powder filling.
Check product name and strength on almonium foil.

DISPENSING:
It is the first step of process and carried out in warehouse, dispensing is the
process of weighing of raw materials.

PREPARATION OF SUGAR BASE SOLUTION:


Sugar is treated with steam and prepares the sugar solution. It is transferred in double
jacketed vessel for cooling.

EQUIPMENT:

Liquid manufacturing vessels are specialised vessels used to manufacture high quality
liquids and solutions required in pharmaceutical industry and other industries. These
vessel are equipped with MS/SS steam jackets and insulation with SS cladding for
uniform heating of the liquid.
The vessel also have a direct top mounted stirrer available with or without top dish;
different types of stirrers are available with the vessel including propeller, pedal, anchor
etc. The capacity can range from 50 liters to 10000 liters and more depending on
individual requirements.

PREPARATION OF C02/ N2 SATURATED WATER:


a. In a separate covered S.S vessel, heat required amount of water purified
(measured by dipstick) to boiling for 30 minutes.
b. Turn off heat & cool the water purified to room temperature while continue
purging the water with C02/ N2 gas for two hours.

FINAL PREPARATION OF SYRUP:


Presoaked materials, sugar based solution are added in the double jacketed steam
vessel which is provided with the agitators for mixing, then add active ingredients,
preservatives, flavoring agents, coloring agents & essence all are added with different
time periods & at different temperatures according to the manufacturing order.
After addition of each ingredient mixing is carried out and checks clarity of solution. If
solution is not clear than again mix the solution for 15-20 minutes.
Volume of syrup is maintained by De-ionized water.

STORAGE:
After manufacturing, syrups are stored in storage tanks & after passing from QC it is
allowed for filling & packing area by the help of pumps. Capacity of storage tanks are
3,000 liters made-up of stainless steel.

BOTTLE WASHING:
There is a separate section for washing of bottles in order to make bottles free from any
dirt, impurity and microbial contamination.

Bottle washing machine:


Bottle washing machine consists of 26 manifolds and eight needles in a bottle washing
machine in which compressed air is passing and it passes to another room through the
same machine there sterilized by the help of dry heat sterilization at 210C.

FILLING OF BOTTLES:
In the manufacturing area, there is an automatic filling system for transferring syrup
from holding vessel to filling area. The filling also have automatic valve system, this set
the flow rate of the syrup according to their requirement. According to that floe rate, a
machine fills the required amount of syrup and then stopped. After filling of syrup in
bottles, it comes for packing.

FEATURE:
Voltage: 220/110V 50/60HZ
Power (w): 500
Air Pressure (mpa):0.5-0.7

Current: 3A
Filling speed: 20-50 bottles/min

LABELLING AND PACKING OF BOTTLES:

Labeling is done manually.

For packing, there are six belts, both automatic and manual.

Five belts are manual.


Only one is automatic named autocartnor packs 85,000 bottles/day.

A conveyor belt then carries the labeled bottles to another turntable. This provides
the bottles to the cam cartoons, the cartooning machine, which is fully automatic.
The cartons are provided from one side, picked up one at a time through the suction
pump. The machine then itself opens the cartons. Places the filled bottles in it and
then folds the flaps to the packed position.

PCI SECTION:
Here in this area, checking is very strict, and done by PCIS (production control
inspector).
The volumes and weights are inspected they should be accurate.
After capping bottles comes on the turntable workers are present on the belt for
labeling, they check the Batch no, Manufacturing Date, Expiry, Retail price.
Check line clearance.
Leak test by applying 20 inches of Hg
Hardness test
Capping test.
Check pH, viscosity, and microscope.
Check weight variation.
Check torque test which will not less than 5 torr.

PEDIALYTE MANUFACTURING AREA:

INTRODUCTION:
Pedialyte is sterilized oral glucose electrolyte solutions intended for the management of
dehydration secondary to diarrhea. Pedialyte is formulated to replace fluid and electrolyte
losses in diarrheal stools. Glucose enhances the absorption of sodium and water in the
small intestine, and helps to prevent tissue catabolism.

PREPARATION OF PEDIALYTE:
In the manufacturing of pedialyte electrolyte oral solution number of steps are involved
which are described as follows.

Preparation of oral solution.

HDPE bottles washing.

Filling

Sealing

Leak test

Sterilization

PREPARATION OF THE ORAL SOLUTION:


Solution prepared in glass-lined or a 316 grade stainless steel tank, cleaned a/c
to SOPS.
Deionized water should use.
Volume of water is checked by calibrated dipstick.
Add & dissolve with mixing the following items
Sodium citrate
Sodium chloride
Potassium citrate
Dextrose powder hydrous
Stir for ten minutes or until all the ingredients are dissolve.
Maximum holding time of product is 12 hours.
Adjust PH 5.6 (B/E 5.4-5.8) with 40% citric acid solution.
Makeup the final volume of solution by deionized water.

H.D.P.E(High density polyethylene) BOTTLES WASHING :


The empty bottles are washed on H.D.P.E bottles washing machine. This machine is
consist of 26 manifolds each contains 3 nozzles & 8 washing stations. The mashing
cycle include compressed air (C.A), fresh water (F.W), and hot deionized water (H.D.W).

WASHING STATION:
C.A--- F.W--- F.W--- F.W--- C.A --- HDW --- HDW --- C.A

FILTERATION:

Filtration of solution is done by using 0.8 microns membrane filtration unit.

FILLING:
Filling of bottles up to 500 ml by pedialyte solution on machine.

SEALING:
Sealing of filled bottles by the help of Aluminum foil at 315C, contact time is 4 seconds.

LEAK TEST:
To check leakage applies pressure on sealed bottles up to 0.2 kg/sq.in.

STERILIZATION OF FILLED & SEALED BOTTLES:


Super heated water autoclave equipped with circulated hot water spray is used
for sterilization of pedialyte bottles.
Place bottles in autoclave art 115C for 30-35 min.
Place atleast 4 thermocouples on different locations in autoclave

One functioning thermocouple located in solution filled containers to indicates &


record the time & temp employed.
Air over pressure is employed in order to maintain autoclave pressure. Pressure
should be gradually increased to a max of 28 psig.
After complete sterilization cool down the bottles by gradually decreasing thr air
over pressure until 4 psig is reach.
Then after sterilization bottles are sent to the finishing area for labeling &
packing.

How supplied:
500ml sterile solution in Aluminum sealed plastic bottle. Available in apple, Strawberry,
Bubble-gum and regular flavors.

GHC (general health care)


PRODUCTION AREA:
In GHC area following products are manufactured;

Mospel liquid 120 ml.


Selsun 205%
Selsun blue balance treatment 80 ml/100 ml.
Selsun blue moisturizing treatment 80 ml/100 ml.

MOSPEL:
Ingredient(s): 50 ml bottle contains: Diethyltoluamide- A mosquito repellent.
Indications : Mospel is an effective mosquito repellent.
Pack Size:

50ml bottle

SELSUN BLUE MOISTURIZING TREATMENT


Ingredient(s): Selenium Sulfide..1% concentrations.

Selsun Blue is indicated for the treatment of dandruff and seborrheic dermatitis of the
scalp. Dandruff control for dry scalp, damaged or chemically treated hairs.

SELSUN 2.5%
Ingredient(s): Selenium Sulfide 2.5% w/v.
Selsun is indicated for the treatment of dandruff, tinea versicolor, and seborrheic
dermatitis of the scalp.

SELSUN BLUE BALANCED TREATMENT


Ingredient(s): Selenium Sulfide..1% concentrations
Selsun Blue is indicated for the treatment of dandruff and
seborrheic dermatitis of the scalp. Dandruff control for all types of hairs.

INJECTION MANUFACTORING
PRODUCT NAME:

Abocain spinal injection.


Abozole injection
Acyclovir injection
Artifen injection.
Bejentan injection.
Bevidox injection.
Dopamine HCl injection 200MG.
Epival injection.
Klaricid injection.
Trividox injection.
Lincomycin injections.
Vancomycin injection
Sterilize water.

(a) ABOCAIN

SPINAL INJECTION

Each ml of solution contains:


Bupivicaine Hcl : 7.5mg
Dextrose anhydrous : 82.5mg
(b) ACYCLOVIR

INJECTIONS

Each 10ml vial contains:


Acyclovir Sodium equivalent to Acyclovir 500mg
(c) DOPAMINE

HCL INJECTIONS 200MG

Each ml contains:
40mg/ML Dopamine Hydrochloride
(d) TRIVIDOX

INJECTION

Each 3 ml of solution contains:


Thiamine HC1 ( B1 )
100 mg
Pyridoxine HC1 ( B6)
30 mg
1000
Cyanocobalamin ( B12)
mcg

(e)

VANCOMYCIN INJECTIONS

1.0GM
Each vial contains:
1.0 gram Vancomycin Hydrochloride (lyophilized) equivalent to
vancomycin 1.0 gram

500MG
Each vial contains:
Vancomycin Hydrochloride quivalent to vancomycin 500mg

(f) LOFTYL

INJECTION

Each 5 ml ampoule contains:


Buflomedil Hydrochloride.50 mg
(g)

ABOZOLE INJECTION

Each ml contains:
Metronidazole.................................5mg
Sodium Chloride.................................7.9mg
Dibasic sodium phosphate, anhydrous.........0.48mg
Citric acid, anhydrous....................0.23mg.
(h) ARTIFEN

INJECTION

Each 3ml ampoule contains:

Diclofenac Sodium. 75mg.


(i) BEJECTAL:
Each ml contains
Vitamin B1 C
Vitamin B2
vitamin B6
Nicotinamide
Dexpanthenol

10 mg
2 mg
5 mg
75 mg
5 mg

(j) BEVIDOX

INJECTION

Bevidox is a parenteral solution of vitamins B1, B6, and B12 for the direct
intramuscular injection or intravenous infusion after dilution with an
appropriate intravenous solution.
Each 3ml ampoule contains:
Thiamine HC1 ( B1 ) 100 mg
Pyridoxine HC1 ( B6) 100 mg
Cyanocobalamin ( B12) 1000 mc.
(k) KLARICID

IV

Klaricid I.V., is a lyophilized powder containing clarithromycin lactobionate


equivalent to 500 mg clarithromycin per vial
(l) EPIVAL

INJECTION

Valproate Sodium 500mg/5ml. Each 5ml contains Valproate sodium


equivalent to 500 mg valproic acid (100mg/ml)

INTRODUCTION:
An injection (often referred to as a "shot" or a "jab") is an infusion method of
putting fluid into the body, usually with a hollow needle and a syringe which is pierced
through the skin to a sufficient depth for the material to be forced into the body. An
injection follows a parenteral route of administration, that is, administered other than
through the digestive tract.
OR
Injections are the sterile liquid preparations containing one or more medicaments
dissolved or suspended in a suitable vehicle and are meant for introduction into the
body tissues by means of an injection under or through one or more layers of the skin or
mucous membarne.

TYPES OF INJECTION:
Types with respect to roots of administration of injection:

Intravenous injection
Intramuscular injection
Subcutaneous injection

INTRAVENEOUS INJECTION:
Intravenous injections are applied into the vein.
USED:
They are used when rapid action of drug is required.

INTRAMUSULAR INJECTION:
An intramuscular (IM) injection is a shot. The needle goes into the muscle to
deliver medicine.IM injections are deeper than subcutaneous injections (given under the
skin).
USED:
Some medicines are better absorbed when given in the muscle; if taken by mouth, they
may not work. Some medications are put in the muscle and absorbed slowly over time.
Other medications are put in the muscle because they are absorbed faster and, if taken
by mouth, would not be effective.
These medications may be given using an IM injection:

Certain antibiotics
Certain contraceptive hormones
Most vaccines
Epinephrine injections for severe allergic reactions

A needle passes through skin and fat layers into the muscle fibers to deliver medicine
It is used where rapid absorption is required through many blood vessel found in
muscles.

SUBCUTANEOUS INJECTION:
A subcutaneous (Sub-Q) injection is a shot that delivers medicine into the fat
layers between the skin and the muscle. The drug moves from the small blood vessels
into the bloodstream.

Used:
Some medicines need to be injected because they are not effective if taken by mouth.
Subcutaneous injections are a easy way to deliver this type of medicine. Examples of
medicines given sub-Q include:
Insulin for people with diabetes
Low molecular weight heparin (eg, enoxaparin) to prevent blood clots

Body tissue layers

TYPES OF INJECTION BOTTLES:


There are two types of injection bottels
Ampoul
Vial
AMPOUL:
An ampoule (also ampule or ampulla) is a small sealed bottle made up of glass or
plastic that contain a sterile medicinal solution or a powder to be made into a solution
for subcutaneous, intramuscular, or intravenous injection.

VIAL:
A vial (also phial) is a relatively small glass vessel or bottle, especially used to store
medication as liquids, powders or in other forms like capsules. They can also be
sample vessels e.g. for use in autosampler devices in analytical chromatography.

RUBBER CLOSURES FOR VIALS:


Each vial is sealed with a rubber closure in place by an aluminium cap.rubber
closures are composed of multiple ingredients that are plasticized and mixed together
at an elvated temperature.The physical properties to be considerd in the selection of a
perticular formulation include elasticity, hardness, tendency to fragment and
permeability to vapour transfer.

PRODUCTION FACCILITIES:
Injection preperation area is the most sterilized area in Pharmaceutical industry
because it is very sensitive in nature and as it has a direct contact with blood so high
accuray and sterlity is consider during manufactoring.

STIMULLATION:
It is the process in which we validate aseptic filling procedure.
In stimulation two types of filtration are used.
Air filteration
Water filteration
(a) AIR FILTERATION:
Air is one of the greatest potential sources of contamination in clean rooms, so it is
being drawn in to clean rooms by heating, ventilating & air conditioning (HVAC)
system.This may be done by a series of treatments that will vary somewhat from one
installation to another.
HVAC SYSTEM:
The HVAC system brings outdoor air into a building, humidifies or dehumidifies it, and
heats or cools it to meet the ventilation and thermal comfort needs of the occupants
and to dilute the contaminants inside the building.
.A typical HVAC system consists of a supply air system, a return air system, and an
exhaust air system. It generally also contains heating and cooling units, a humidifier, air
filters, and fans, which treat and move the air. Controls are used to ensure that the
system functions as desired.

Supply air is a mixture of outdoor air and return air (recirculated air) that is
treated, conditioned, and supplied to the room by the HVAC system.
Return air is air from the room that is recirculated into the mixing chamber by the
HVAC system.
Exhaust air is the air from the room that is exhausted from the building by the
HVAC system.
Functions:
Heating is significant in maintaining adequate room temperature especially
during colder weather conditions. Furnace or boiler, heat pump, and radiator
make up the heating system.
Ventilation is associated with air movement. Ventilation is necessary to allow
carbon dioxide to go out and oxygen to get in, making sure that people are
inhaling fresh air. Stagnant air causes the spreading of sickness, usually
airborne, and allergies.
Air-conditioning system controls the heat as well as ventilation.

WORKING:

The air coming from HVAC system is passed through the PRE FILTER, usually of glass
wool, cloth or shredded plastic, to remove large particles.
After passing through pre filter the air is than pass through the most efficient cleaning
device, a HEPA filter.
The clean, aseptic air is introduce into the class 100 area and maintained under
positive pressure, which prevents outside air from rushing into the aseptic area through
cracks, temporarily open doors or other openings.

HEPA FILTERS:

The required environmental control of aseptic areas has been made by the use of
laminar air flow, originating through a HEPA filter.
Laminar Airflow: Unidirectional airflow moving along parallel flow lines at a constant
velocity minimizes air turbulence within the work area.
HEPA (high efficiency particulate air) filters are air filters that remove
particles from the air by forcing air through screens with microscopic pores.
HEPA filters are capable of removing 99.97 percent of the particles that are 0.3 microns
or larger from the air. It must allow, on average, only 3 particles out of every 10,000 to
pass through the filter. This means a HEPA filter is very effective at filtering out allergens
and asthma triggers (e.g., dust, pollen, mold, dander, tobacco smoke).
CONSTRUCTION:
HEPA filters are composed of a mat of randomly arranged fibers. The fibers are typically
composed of fiberglass and possess diameters between 0.5 and 2.0 micron. Key
factors affecting function are fiber diameter, filter thickness, and face velocity. The air
space between HEPA filter fibers is much greater than 0.3 m.
WORKING:
The common assumption that a HEPA filter acts like a sieve where particles smaller
than the largest opening can pass through is incorrect. HEPA filters are designed to
target much smaller pollutants and particles. These particles are trapped (they stick to a
fiber) through a combination of the following three mechanisms:
INTERCEPTION: where particles following a line of flow in the air stream come

within one radius of a fiber and adhere to it.


IMPACTION: where larger particles are unable to avoid fibers by following the
curving contours of the air stream and are forced to embed in one of them

directly; this effect increases with diminishing fiber separation and higher air flow
velocity.
DIFFUSION: an enhancing mechanism is a result of the collision with gas

molecules by the smallest particles, especially those below 0.1 m in diameter,


which are thereby impeded and delayed in their path through the filter; this
behavior is similar to Brownian motion and raises the probability that a particle
will be stopped by either of the two mechanisms above; it becomes dominant at
lower air flow velocities.

WATER FOR INJECTION:


Water for injection is apyrogenic distilled water intended for use in the preparation of
medicines for parenteral administration when water is used as a vehicle and dissolving
or diluting substances or preparations for injectable preparation.
GENERAL CONCEPT STRUCTURE:
Potable water or
Purified water

Distillation unit

Water for
Injection

PREPARATION OF WATER FOR INJECTION:

Take sufficient quantity of potable or purified water in a metal water still or glass
distillation unit of neutral glass.
Boil the water using burner or electricity.
Allow to form sufficient steam.
Steam is condensed to water for injection using water condenser by distillation
unit.
The first 50 ml portion of distillate is discarded and remainder is collected in a
suitable borosilicate container.
Rinse the container with water for injection and then reject that water for
injection.

Continue the process and collect the distillate in a suitable borosilicate container.
The ph of water for injection must be 5-7.

CHECK OF WATER BEFORE USE:

Conductance test
Ph test
Chloride test.

PRODUCTION OF INJECTION:
The preparation step should be done to prepared injection which are as follow:

Line clearence.
Dispensing.
Washing of injection bottels.
Compounding.
Filling of injection.
Leak test.
Optical test.
Packaging area.
PCI section.

LINE CLEARENCE:
Line clearance is check by worker, supervisor as well as PCI i.e Production
Control Inspector. The line clearance include following steps:

Check pressure, temperature as per SOP requirement.


Check gas protection where required.
Check the equipment/area is cleaned.
Check no identity sign from previous batch.
Check required commodities of the batch area available as per finishing shop
order.
Check exhaust are operational in powder filling.
Check product name and strength on almonium foil.

DISPENSING:

It is the first step of process and carried out in warehouse, dispensing is the
process of weighing of raw materials.

WASHING & STERILIZATION OF EMPTY AMPULS


AND VIALS:
Ampoules and vials are washed mechanically by means of machines. For this purpose
two types of machines are used
Compact line machine.
Abbott local machine.
COMPACT LINE MACHINES:

It is automatic in which washing, sterilization, filling and sealing is done simultaneously.


In Abbott it is set for the washing of 3ml ampoules.
These machines have many features such as: water spraying, alternating water and
compressed air flushing, drying, sterilizing, cooling, filling, gas flushing, sealing etc. It
adopts photoelectric technology, PLC and color touch LCD screen for the control
system. With such a high degree automation, fewer operator needed to use this
machine.
In order to meet the GMP requirements, laminar air flow above the filling and sealing
machine is included.
In order to meet the GMP requirements, laminar air flow above the filling and sealing
machine is included.
This line is highly flexible, can be used for 1 to 5 ml ampoules, with few parts needed to
be replaced.
This line is the highest output ampoule compact line in the world at present.
Main applications

This line is highly flexible, can be used for 1 to 5 ml ampoules, with few parts needed to
be replaced.
This line is the highest output ampoule compact line in the world at present.

FEATURES:

Pressurized flow of water is passed through washing needle for pressure


cleaning at minimum usages of washing machine.

Concept of pressure tanks for reverses & continuous supply of washes medias is
apt in this machine.

Acrylic top cover is given, to clearly view washing events taking place in the
machine.

On-line poly carbonates of 10 microns for water and 5 microns for air are used,
for best possible washing.

All contact parts of washing machine are usually made of stainless steel.

If acrylic cover is lifted during cycle operation, the machine will automatically stop
and re-start from the point when cover is pushed down.

Output capacity of 300 Ampoules / min.

Pressure of Water and Air is not less than 17 psi.

STEPS OF WASHING:
1. Ampoule first wash with recycled distilled water
2. Compressed Air
3. Distilled Water
4. Compressed Air
.
STERILIZATION:
After washing ampoules enter into the sterilizing chamber (OVEN).Dry heat
sterilization is occur at 335C for 1 hr.

ABBOTT LOCAL MACHINE:

The machine is designed for washing of ampoule and vials.

STEPS OF WASHING:
1. Compressed Air
2. Tap Water
3. Tap Water
4. Tap Water
5. Compressed Air
6. Distilled Water
7. Distilled Water
8. Compressed Air
Pressure of Water and Air is 10 psi.

STERILIZATION:
Ampoules or vials are sterilized in OVEN at 210 220C, time is 5 hrs.

COMPOUNDING:
The second step is formulation and solution preparation .Solutions are not
standardized but prepared in batch manufacturing using sterile water. Preparation
occur in DOUBLE JACKETED PRESSURE VESSEL made up of STAINLESS
STEEL (non reactive, easy to clean, no growth of microorganism), mixing occur by
means of PROPELLER. All equipment must be dry and sterile, follow established
order of mixing (MANUFACTURING ORDER),For parenteral preparation maintain
proper reduction of particle size under aseptic conditions, Distilled water used as
solvent should be kept and stores at 60 80C and used with in 24 hrs. It is done in
compounding area.
BATCH REACTOR:
Within the chemical and pharmaceutical industries, external cooling jackets are
generally preferred as they make the vessel easier to clean. The performance of these
jackets can be defined by 3 parameters:

Response time to modify the jacket temperature


Uniformity of jacket temperature

Stability of jacket temperature

A chemical reactor in which the reactants and catalyst are introduced in the desired
quantities and the vessel is then closed to the delivery of additional material.
The Batch reactor is the generic term for a type of vessel widely used in the
process industries. Vessels of this type are used for a variety of process operations

such as solids dissolution, product mixing, chemical reactions, batch distillation,


crystallization, liquid/liquid extraction and polymerization.

A typical batch reactor consists of a tank with an agitator and integral heating/cooling
system. These vessels may vary in size from less than 1 litre to more than 15,000 litres.
They are usually fabricated in, stainless steel. Liquids and solids are usually charged via
connections in the top cover of the reactor. Vapors and gases also discharge through
connections in the top. Liquids are usually discharged out of the bottom.
The advantages of the batch reactor lie with its versatility. A single vessel can carry out
a sequence of different operations without the need to break containment. This is
particularly useful when processing, toxic or highly potent compounds.

Agitation
The usual agitator arrangement is a centrally mounted driveshaft with an overhead drive
unit. Impeller blades are mounted on the shaft. A wide variety of blade designs are used
and typically the blades cover about two thirds of the diameter of the reactor. Where
viscous products are handled, anchor shaped paddles are often used which have a
close clearance between the blade and the vessel walls.

With propeller scrapper is also introduce in reactor because of the fact that cream, gel
e.t.c are very viscous in nature and hence need scrapper for efficient mixing. Most batch
reactors also use baffles. These are stationary blades which break up flow caused by
the rotating agitator. These may be fixed to the vessel cover or mounted on the side
walls.
Despite significant improvements in agitator blade and baffle design, mixing in large
batch reactors is ultimately constrained by the amount of energy that can be applied. On
large vessels, mixing energies of more than 5 Watts per litre can put an unacceptable
burden on the cooling system. High agitator loads can also create shaft stability
problems. Where mixing is a critical parameter, the batch reactor is not the ideal
solution. Much higher mixing rates can be achieved by using smaller flowing systems
with high speed agitators, scrapper, ultrasonic mixing or static mixers.
Heat cooling systems
Products within batch reactors usually liberate or absorb heat during processing. Even
the action of stirring stored liquids generates heat. In order to hold the reactor contents
at the desired temperature, heat has to be added or removed by a cooling jacket or
cooling pipe. Heating/cooling coils or external jackets are used for heating and cooling
batch reactors. Heat transfer fluid passes through the jacket or coils to add or remove
heat.
It can be argued that heat transfer coefficient is also an important parameter. It has to
be recognized however that large batch reactors with external cooling jackets have
severe heat transfer constraints by virtue of design. It is difficult to achieve better than
100 Watts/litre even with ideal heat transfer conditions. By contrast, continuous reactors
can deliver cooling capacities in excess of 10,000 W/litre. For processes with very high
heat loads, there are better solutions than batch reactors.
Fast temperature control response and uniform jacket heating and cooling is particularly
important for crystallization processes or operations where the product or process is
very temperature sensitive. There are several types of batch reactor cooling jackets:
Single external jacket

The single jacket design consists of an outer jacket which surrounds the vessel. Heat
transfer fluid flows around the jacket and is injected at high velocity via nozzles. The
temperature in the jacket is regulated to control heating or cooling.
The single jacket is probably the oldest design of external cooling jacket. Despite being
a tried and tested solution, it has some limitations. On large vessels, it can take many
minutes to adjust the temperature of the fluid in the cooling jacket. This results in
sluggish temperature control. The distribution of heat transfer fluid is also far from ideal
and the heating or cooling tends to vary between the side walls and bottom dish.
Another issue to consider is the inlet temperature of the heat transfer fluid which can
oscillate (in response to the temperature control valve) over a wide temperature range
to cause hot or cold spots at the jacket inlet points.

FILTERING:
For filtration of injection MILLIPORE filters are used.
MILLIPORE FILTER: It is a filtration device consists of two filters between two
plates.

Prefilter: prefilter is made up of cellulose, 25 microns porosity.

Filter: It is made up of Polyamide, 2 microns porosity.

Filtering is occurring to remove particles 2 -3 microns in size.

FILLING AND SEALING:


Filling is carried out on aseptic area.

Filling must be done with minimum exposure time.

Fill under a blanket of HEPA-filtered laminar-flow air.

Flow air while filling until sealing.

Employ aseptic technique.

For smaller volume of liquid: use hypodermic syringe.

LIQUIDS:
For large volume of liquid: liquid filters used with multiple filling units.Liquid
injections are filled in ampoules, before and after filling purging of nitrogen or
any CO2 gas is occur to avoid the decomposition of product as the injection
may react with air and oxidizes. CO2 is mostly purge while using vitamins but it
is not use when we are dealing water.

SOLID:
Liquid injection is filled in a vial, vial is closed with rubber closer and then
injection is solidify by process of lyophilization.

LYOPHILIZATION:

Principle: As a basic principle, lyophilization has its advantages for filling if the
medication is not sufficiently stable in solution, temperature sensitive,chemically
reactive with one another and/or if the exact dosage is not possible using a dried filling.
Equipment:
A lyophilizer consists of a vacuum chamber that contains product shelves capable of
cooling and heating containers and their contents. A vacuum pump, a refrigeration unit,
and associated controls are connected to the vacuum chamber. Chemicals used in IVD

products are generally placed in containers such as glass vials that are placed on the
shelves within the vacuum chamber. Cooling elements within the shelves freeze the
product. Once the product is frozen, the vacuum pump evacuates the chamber and the
product is heated. Heat is transferred by thermal conduction from the shelf, through the
vial, and ultimately into the product.
Process:
The first step in the lyophilization process is to freeze a product to solidify all of its water
molecules. Once frozen, the product is placed in a vacuum and gradually heated
without melting the product. This process, called sublimation, transforms the ice directly
into water vapor, without first passing through the liquid state. The water vapor given off
by the product in the sublimation phase condenses as ice on a collection trap, known as
a condenser, within the lyophilizer's vacuum chamber. To be considered stable, a
lyophilized product should contain 3% or less of its original moisture content and be
properly sealed.
The process is carried out under aseptic conditions and takes approx. 2 days (differs
depending on the agent and the application system).

Lyophilization Container Requirements


The container in which a substance is lyophilized must permit thermal conductivity, be
capable of being tightly sealed at the end of the lyophilization cycle, and minimize the
amount of moisture to permeate its walls and seal. The enclosed reagents can only
remain properly lyophilized if the container in which they are processed meets these
requirements.
Benefits of lyophilization:
Compared to common drying procedures, lyophilization protects the agent from
denaturation caused by heat since the agent remain as frozen throughout the entire
process.

Medications which are processed in this manner can be stored up to three years
provided best conditions - while the same combination of agents in liquid form
can become useless within a few days.
During the course of the procedure, no significant changes occure in the agent
and consequently, risk of possible loss of biological activity is reduced comparing
it with common filling processes.

By virtue of its shelf life, the lopyhilized product can also be reconstituted in a
minimum of time.

The process gives product excellent solubility characteristics, allowing for rapid
reconstitution.

Heat- and moisture-sensitive compounds retain their viability.

Most proteins do not denature during the process, and bacterial growth and
enzyme action, which normally occur in aqueous preparations, can be
eliminated.

SEALING:
Filled bottles should be sealed as soon as possible to prevent contaminations.
For Ampules fusion method (melting a portion of the glass neck).
Pull Sealing:

Heating the neck of ampule below tip, leaving enough of the tip for
grasping.
Ampule is rotated in a single flame.

When glass has softened, the tip is grasped firmaly and pulled quickly
away from the body which continue to rotate thus, the small capillary tube
formed is twisted closed.

Pull sealing is slow but reliable than tip sealing.

For Vial:
After lyophilization vials closed with rubber closers are sealed by means of
Aluminum Caps. The cap cover the closure and crimped under the lip of the vial
to hold them in place. The closure can not be removed without destroying the
aluminum cap.

STERILIZATION:
The parenteral product should be sterilized after being sealed in its final container
or a bottle, it is called TERMINAL STERILIZATION and within as short a time as
possible after the filling and sealing has been completed.
Purpose: To destroy microorganisms and there spores.
Method: Ampules can be sterilized by steam sterilization.

Saturated steam under pressure(auto clave, pot & double door) 121C , 15
30 mins, 15 psi

It is the most effective method, commonly used for solutions containing heat
stable substances.

FOR AMPOULES:
LEAK TEST:
The test is carried out in a vessel made up of stainless steel. The ampoules are
place in boxes are place inverted on a shelves in a vessel, a small amount of dye
solution (methylene blue approved by world health organizations WHO) is added

in each box, vacuumed and then pressure is applied dye enter into the ampoule,
time is approx 1 hr after this ampoules are dipped in water leak ampoules float
on the surface and discarded.
OPTICAL TESTING:
All of the ampoules should be inspected by human inspector under good light
and against white and black back ground. Any container which visible particle
can be seen is discarded. In this test crack on any bottle and printing of
manufacturing, expiry date, batch no and retail price is also check.
VOLUME VARIATION TEST:
Volume of injection must be in the in process limit and less then QA limit. In
this test ampoule seal is broken and injection with help of syringe is add into
cylinder (A class), volume is measured. About 10 ampules are taken in one time,
the test is repeated after 3 hrs during production.

FOR VIALS:

Volume Variation test:


Before lyophilization the volume of injection must be equal to target limit. Volume is
measured by mean of cylinder.
Optical Test:
After lyophilization vial is optically tested to ensure the proper formation of cake, to
check crack on bottle etc.
Reconstitution test:
In a vial water for injection (volume mention in direction)is added with help of syringe
and left for a time, injection must dissolve completely and efficiently.

LABELING OF VIALS:

Label name of preparation, percentage content of drug, amt of active ing, volume off
liquid to be added, route of administration, storage, expiration date, name of
manufacture, batch no.
Container label should be arranged that a sufficient area is uncovered to allow
inspection of contents.

PCI SECTION:
FOR AMPOULES:
Check line clearance.
Check GMP.
Check volume variation for >3ml ampoules.
Check weight variation for<3ml ampoules.
Check leak test.
Check optical test.
FOR VIALS
Check leak test.
Check Optical test.
Check weight variation.
Check reconstitution

TABLET MANUFACTORING
PRODUCT NAME:

Abbutol tablet
Abozole tablet.
Abrifen tablet.
Arinac tablet.
Artifen tablet
Becefol tablet.
Brufen tablet.
Cofcol tablet
Epival tablet.
Isoptin tablet.
Surbex-T tablet
Surbex-Z tablet
Entramizole tablet.
Klaricid tablet.

(a) ABBUTOL
Each Abbutol Filmtab tablet contains :
Ethambutol HCl .. . 400 mg
(b) ABOZOLE

TABLETS

Each Filmtab tablet contains:


400MG Metronidazole
(c) ABRIFAM

450, 600mg

Each Abrifam 450,600 mg Filmtab tablet contains :


Rifampicin . 450, 600mg
(d) ARINAC

TABLET

Each tablet contains :


Ibuprofen : 200 mg
Pseudoephedrine HCl : 30 mg
(e) ARTIFEN

TABLETS

Tablet: 25 mg: Each enteric-coated tablet contains: Diclofenac


Sodium.25mg.
Tablet: 50 mg: Each enteric-coated tablet contains: Diclofenac
Sodium.50mg.
(f)

BECEFOL

Each Becefol tablet provides the following ingredients:


Composition
Dosage
Vitamin C
750 mg
Nicotinamide
100 mg
Vitamin E .
30 IU
Calcium pantothenate
20 mg
Vitamin B1 (Thiamine)
15 mg
Vitamin B2 (Riboflavin)
10 mg
Vitamin B6 (Pyridoxine
5 mg
hydrochloride)
Vitamin B12
4 mcg
Folic Acid
150
G
(g) BRUFEN

TABLET 200, 400,

600MG
Each tablet contains:
Ibuprofen : 200, 400, 600mg respectively.
(h) COFCOL
Each Cofcol tablet or each tablespoon (15ml) of
Cofcol Elixir provides:
Paracetamol ....................325mg
Pseudoephedrine HCl ...........30 mg

Chlorpheniramine maleate...........1 mg
Dextromethorphan HBr ...........10 mg
Vitamin C ......................50 mg

(i)

ENTAMIZOLE TABLET

Each tab contains:


Diloxanide furoate 250mg
Metronidazole 200mg
(j) EPIVAL

TABLET 250, 500MG

Divalproex Sodium Equivalent to Valproic Acid 250, 500 mg


.
(k)

EPIVAL CR TABLET

Divalproex Sodium Equivalent to Valproic Acid 500 mg in controlled release tablet


(l)

ISOPTIN 40,80 MG

Each tablet contains:


Verapamil Hydrochloride..40, 80mg
(m) KLARICID

TABLETS

Each Klaricid 250 mg Tablet contains: Clarithromycin 250 mg


Each Klaricid 500 mg Tablet contains: Clarithromycin 500 mg
(n) SURBEX-T
Each Surbex tablet provides the following ingredients;
Composition
Vitamin B1
15 mg
Vitamin B2
10 mg
Vitamin B6
5 mg
Vitamin B12
4 mcg
Nicotinamide
100 mg
Calcium Pantothenate
20 mg
Vitamin C

500mg

(o) SURBEX-Z

TABLETS

Each Surbex Z filmtab tablet provides the following ingredients:


Composition
Vitamin C
500 mg
Nicotinamide
100 mg
Vitamin E
30 IU
Calcium pantothenate (Pantothenic Acid) 20 mg
Vitamin B1 (Thiamine)
15 mg
Vitamin B2 (Riboflavin)
15 mg
Vitamin B6 (Pyridoxine hydrochloride
20 mg
Vitamin B12
12 mcg
Folic Acid
150 mcg
Zinc (equivalen to 100 mg of Zinc sulfate) 22.5mg

INTRODUCTION:
The solid unit dosage form of medicaments with or without suitable diluents and
prepared either by molding or compression, is called a tablet.

TYPES OF TABLET:
These include:
1. Oral tablets.
2. Chewable tablets.
3. Buccal tablets.
4. Lozenges tablets.
5. Soluble tablets.
6. Effervesent tablets.
7. Sugar coated tablets.
8. Film coated tablets.
9. Layered tablets.
10. Sustained action tablets.

1. ORAL TABLETS:
These tablets are swallowed.Most of them are formulated in such a way that they
disintegrate in the stomach and dissolve in the gastric fluids.A disintegrating
agent must be added in the tablet formulation.

2. CHEWABLE TABLETS:
These are tablets which are required to be broken and chewed in between the
teeth.These tablets are given to the children who have difficulty in swallowing
.These tablets should have a very acceptable taste and flavor so usually sorbitol,
lactose, chocolate powder and dextrose are used as a flvoring agent.
Disintegrants are not required here.

3. BUCCAL TABLETS:
These tablets are required to be placed below the tongue or in the side of the
buccal for the slow release of medicaments.Generally they contain those drugs
which are generally destroyed, inactivated or not absorbed in the GIT but are
directly absorbed through the mucosal tissues. They must have sweetening
agent like manitol.

4. LOZENGES:
Lozenges are tablet that dissolves slowly in the mouth and so release the drug
dissolved in the saliva. Lozenges are used for local medication in the mouth or
throat.
They used all excepients apart from disintegrants.

5. SOLUBLE:
These tablets are required to dissolve completely in the liquid to produce solution
of definite concentration.

6. EFFERVESCENT TABLET:
These tablets along with the active medicaments contain other ingredients like
sodium bi carbonate, citric acid and tartaric acid which reacts in the presence of
moisture liberating CO2 and producing effervescence leading to the disintegration
of the tablets.

7. SUGAR OCATED TABLETS:


They are given a sugar coating to mask the objectional taste and odour of the
drug as well as to protect the substance from atmospheric conditions.\

8. FILM COATED TABLETS:


Film coating involves the depositions, usually by a spray method of a thin film of
polymer surrounding the tablet core .The coating liquid contains a polymer in a
suitable liquid medium together with other ingredients such as pigments and
plasticizers.

9. LAYERED TABLETS:

Granules of incompatible substances are compressed into two layers


successively in the same tablet.

(10) SUSTAINED ACTION TABLETS:


These are the tablets which after oral administration release the drug at a desired
time and prolong the effect of medicament.

TABLET EXCEPIENT:
Compressed tablet usually consist s of active medicament, mixed with a no. of
inert substances known as excepient or additives.

1. DILUENTS:
When the quantity of drug for an individual dose is small and it is difficult to
compress such small amount in the form of a tablet then the inert substance
which are added to increase the bulk of powders so that it is easy to
compressed, and are known as diluents for example lactose, starch, sodium
chloride, calcium carbonate, manitol etc.

2. BINDERS:
The agents used during granulation to impart cohesiveness to the powdered
substances are known as binders. They keep the tablet intact after
compression e.g.starch, acacia, gelatin, methyl cellulose, glucose, lactose.
Sometimes they are used in dry form, while sometimes by dissolving in other
solvents like water or alcohol.

3. GRANULATING AGENT:
Granulating agents are the substances which are added to powder during
granulation process to convert fine powders into granules.The quantity of
proper granulating agent to be added is very critical. Examples are water,
mucilages of acacia, starch, liquid glucose, syrup e.t.c.

4. DISINTEGRATING AGENTS:
Disintegrators are the substances or a mixture of substances which are
added to tablet to facilitate their disintegration or breaking apart into small
particles after administration, thus facilitating dissolution.

Two types of disintegrating agents are used,


Substances that swell up when they come in contact with moisture.
Substances which react with effervescence when they come in contact
with moisture.
The most popular disintegrating agents are maize starch, corn starch, potato
starch, methyl cellulose, carboxy methyl cellulose, citrus pulp e.t.c.
The other type include citric acid, tartaric acid and sodium bicarbonate.

5. LUBRICANTS:
Lubricants are the substances which are added to granules before
compression to improve the flow of granules from the die cavity by reducing
interparticle friction, and to facilitate the ejection of the tablet from die cavity
after compression. Examples are Magnesium stearate, calcium stearate,
stearic acid, talc, cocoa butter, waxes and liquid parrafins.

6. COLORING AGENT:
They are used to impart elegance to the tablet and also used to identify
different types of tablet. Examples are permitted food colors and edible dyes.

7. FLAVORING AGENT:
Flavors are added to enhance or mask the taste of drug. Fruit flavours, oils
and volatile substances are used for this purpose.

8. SWEETENING AGENT:
Sweetening agents are added to the tablets which are required to be
dissolved in the buccal cavity. Examples are manitol, lactose and sucrose.

PREPARATION OF TABLETS:
There are following step done during preparation of tablet.
Line clearance.
Dispensing section.
Granulation section.
Compression section.
Coating section.
PCI section.
Low RH section.
Potent sction.

LINE CLEARENCE:
The step involve are:

Check pressure, temperature as per SOP requirement.


Check gas protection where required.
Check the equipment/area is cleaned.
Check no identity sign from previous batch.
Check required commodities of the batch area available as per finishing shop
order.
Check exhaust are operational in powder filling.
Check product name and strength on almonium foil.

DISPENSING SECTION:
The APIs and excipient are weighed for example the drug (ibuprofen) and
different additives (starch as binder) are first weighed to make an accurate
composition.

GRANULATION SECTION:
The granulation section involve following step:

Sieving
Mixing/Formation of granules
Sieving
Drying
Sieving
Blending.

SEIVING:
This is the first step in which sieving of raw material is done in order to get
accuracy. The machine used for sieving is called RUSSEL SHIFTER.

MIXING:
The mixing of API and excipient is done as define in directions by MORTEN
RIDER in which by efficient mixing and addition of binder formation of massive mass is
done like ibuprofen and starch are mixed efficiently with each other in High shear mixer
granulator at a speed of 27 rpm, major portion of the disintegrating agent is
incorporated and mixed uniformly.

SEIVING:
Then the massive mass is sieved by passing through 3/8 inch sieved and this is called
intermediate granule. The machine used for this is called TORNATE MILL.
DRYING:
The wet granules thus obtained, are dried in fluidized bed driers for about 70 minutes.
The temperature inside fluidized bed is 70 0C.The hot air pressure is more than 3500
cfm. After drying, it is tested for L.O.D and then sends for blending. Capacity of
fluidized bed is 60 kg, 120 kg and 300 kg.

SEIVING:
The dry mass is passed through 12 inch mesh size.
BLENDING:
The granules are then passed through a 12 mesh sieve, and then it is entered
into the Double cone blender where the granules are then mixed with other additives
like the second portion of disintegrating agent, lubricants and flavoring agents.

FEATURES:

The conical shape of both ends enables uniform mixing and easy discharge.
All contact parts are made out of SS304 quality material.

Maximum care has been taken to ensure safe operation of the unit.

COMPRESSION SECTION:
The blended granules are now finally ready for compression.
TABLET COMPRESSION:
For the compression of granules in the form of tablet, two types of machines of
machines called tablet presses are used, which are as follows.

SINGLE HOPPER MACHINES:


In these types of machines one set of die and punch is fitted and only one tablet
can be compressed at one time. They can be hand operated or power operated
and with these machines 60 to 90 tablets/ minute can be prepared the granulated
material ready for punch is placed in the hopper from where it feeds into the die
where it is compressed in between the two punches.

TWO HOPPER MACHINE:


The construction and working of multi punch machine is similar as that of single
punch machines with difference that a number of dies are are fitted in steel frame
having two punches.

ROTARY TABLET MACHINE:


For large scale production, rotary tablet machines are used. Rotary tablet
machines carries a number of sets of punches and dies revolves continuously
while the tablet granulation runs from the hopper into the dies placed in a large,
steel plate revolving under it.Compresion takes place as the upper and the lower
punches pass between a pair of rollers then the lower punch lifts up and ejects
the tablet.

TABLET COATING:
Tablets are coated for the sake of improving their appearance, taste and stability. More
recently coating has been used to control the site of drug release and delay the release
of drug from the dosage form.
TYPES OF COATING:

Methods used for tablet coating are as follows,


Sugar coating.
Film coating.
SUGAR COATING:
It is used to mask the unpleasant taste and odour, to improve appearance and to protect
the ingredients from decomposition exposure to air and moisture.
APPARATUS:
The coating pans are spherical vessels made up of stainless steel which rotate on the
axis driven by a motor.

STEPS OF THE PROCESS:


Water proofing.
Subcoating.
Smoothing.
Coloring and finishing.
Polishing.
WATER PROOFING:
Water is used to dissolve sugar for coating and it may be destroyed the drugs so to
prevent this tablets are given one or two coatings of water proof materials such as
shellac, ethyl cellulose e.t.c. After water proof coating, tablets are allowed to dry in
air.
SUB-COATING:

The water proof coated tablets are put in the pan and rotated at a speed of 19 rpm
and a heavy syrup consisting of acacia and sugar solution is added on the rotating
table.The tablets are allowed to roll until they become sticky and adhere to each
other and to the pan.At this point, tablet are dusted with calcium powder until they
lose their tendency to adhere and the rotation is continued until the tablets are fully
dried then building solution made up of CMC, sugar and calcium is sprayed.
SMOOTHING:
The sub-coated tablets are put in pan and given a few coatings of heavy sugar syrup
which are dried simultaneously until a smooth surface is obtained and tablets of
specific size are produced.
COLORING:
Water soluble color is dissolved in the diluted syrup
and several coating of this
0
diluted syrup are given at a temperature of 45 C, drying each time.
FINISHING:
The thoroughly dried coated tablets are transferred into polishing pans.The polishing
pans are rotated and paraffin polishing solution is added.Allow to run for 5 to10
minutes, during this sprinkle purified talc in pan.

FILM COATING:
Film coating involves the deposition, usually by a spray method of a thin film of polymer
surrounding the tablet core .The coating liquid contains a polymer in a suitable liquid
medium together with other ingredients such as pigments and plasticizers.

PROCEDURE:
First we warm the tablets until the exhaust temperature is 49-58 0C. The coating material
such as CMC or other high polymers are dissolved in a volatile solvent and sprayed with
the help of guns to the tablet rotating in a coating pan .After coating the tablets are
stored in polyethylene bags.
COATING MACHINES:

Accela cota 60.


China cota 48.
Thai cota 61.

PACKAGING OF TABLETS:
Tablets are enclosed individually in strips or blister packs and in bottle packings.

IN STRIP PACKING:
The unit drugs are sealed in between strips of aluminium foil.

IN BLISTER PACKING:
The unit dosage forms are enclosed in between transparent blisters and suitable
material, generally aluminium foil with the help of packing machines.

IN BOTTLE PACKS:
The number of tablets (10 or 20) is filled in bottles and the cap of the bottle is
tightened with the help of machines.

PCI SECTION:
The PCI section checked the following test:

To check line clearance.


Check the shape, size and physical appearance of tablet.
Check the uniformity of weight.
Check the hardness test.
Check the disintegration test.
Check the count of tablets
Check physical appearance of tablets

LOW RH SECTION:
In this section those product that are moisture sensitive or degrade in moisture
are prepared.
All the steps are similar as defined above but the only difference is that in this
area low RH is maintained.
The packaging is also done in low RH environment.

POTENT SECTION:
In this section those tablet whose API is highly intense so that is could be harmful for
human even in the minor increment. For this purpose the environment is highly
sensitive and high attention is done during manufacturing.

You might also like