You are on page 1of 1

HPlaserjet M600, 601, 602

SSM firmware upgrade


Author: Charles Sheffield Reference Number: AA-05410 Views: 670
Created: 2012-06-04 05:01 pm Last Updated: 2012-06-04 05:01 pm

0 Rating/
Voters

1 Turn the product on. The Message error 99.09.67 disk not bootable appear on the control
panel display. Press the OK button to continue.
2 Wait for the preboot menu to appear on the control panel display, and then press the
down arrow button to scroll to administrator. press
the ok button to select it
3 Press the down arrow button to scroll to download . Press the OK button to select it.
4 Press the down arrow button to scroll to USB thumbdrive. Press the ok button to select
it
5 Several .bdl files might be listed, Press the down arrow button to scroll to the firmware
upgrade file that you downloaded earlier. Press the ok button
to select it.
accessory)

( IF no .bdl files are listed, try saving the file to a different USB storage

6 Wait while the file transfer. When the transfer is complete, the message COMPLETE
appears on the screen
7 Turn the product off, remove the USB storage accessory, and then turn the product on.
Wait for several minutes while the product initializes