2ppt Sanitary Sewer Design
2ppt Sanitary Sewer Design
Water Supply
Robert Pitt
University of Alabama
and
Shirley Clark
Penn State - Harrisburg
McKinney and Schoch
House drain
at the Agora,
Athens,
Greece (1st
to 4th century
BC)
"Tout-a-la-rue (all in
the streets), with the
expectation that dogs,
pigs, and rain would
effectively remove
wastes. This was the
waste disposal policy in
most western cities
until the late 1800s.
More people
were able to
have a flush
toilet, not
just the rich.
First US
treatment
plant built in
NYC in 1886
to protect
Coney Island
beaches from
vast increases
in wastewater
volume.
Coombs and
Boucher
The anticontagionist,
anticontagionist, or miasmic, disease etiology belief held that
putrefying organic matter in sewers exuded noxious disease
causing gases; separateseparate-sewer systems were advocated as the
appropriate means to rapidly remove (< 2 or 3 days) human wastes
from cities
Slide by Steve Burion, Univ. of Utah
Gravity
Pressure
Vacuum
Pressure
Sewer
System
Vacuum
Sewer
System
Assignment
Write a short essay (about 2 double-spaced
typed pages) comparing either the London or
Paris water delivery and wastewater collection
systems to modern systems in your
community.
Defective pipes
Leaking pipe joints
Poor connections
Cracked manhole walls
etc.
10
Is this legal?
The Clean Water Act of 1972 only allows
bypasses in the cases of emergencies
Typically, a rain storm is not considered an
emergency
Jefferson County lost a major lawsuit to the
EPA, ADEM, and citizens and is required to
correct the sanitary sewer system and expand
treatment capacity, and spend about $30
million to purchase stream corridors buffers.
11
Insufficient
System
Capacity
Infiltration and
Inflow
Effects of SSOs
Environmental
Nutrients and toxicants may cause algal blooms and
harm wildlife. Algal blooms remove O2 from water,
smothering aquatic life.
Decrease in water quality reduces number and range of
plants and fish.
Public Health
Direct contact with water containing sewage can cause
skin and ear infections and gastroenteritis, and cuts
become infected.
Illnesses result from eating fish/shellfish that swim in
sewage contaminated waters.
Inhalation and skin absorption can also cause disease.
12
Hydrogen sulfide
generation in
wastewater with
more than 1 mg/L
DO
13
EBOD
Z = (0.308) 0.50 0.33
So Q
)(
P
B
P/B is the ratio of the wetted perimeter to the top width of the flow
Chin 2006
simplifying:
2 / 3 ( sin )5 / 3 = 5.95
P
4.3 radians
=
= 2.57
B 2 sin (4.3 radians / 2 )
P
=
B 2 sin ( / 2)
where is the angle from the center of the pipe to the edge of
the water surface, in radians. The following equation can be
solved by iteration to obtain :
421 mg / L
Z = (0.308)
(0.009 )0.50 1.7m 3 / sec
2 / 3 ( sin )5 / 3 20.16nQD 8 / 3 S o1 / 2 = 0
0.33
(2.57 ) = 2,948
14
15
Calculation/Estimation of Infiltration/Inflow
for New Construction
16
17
The total city flow, excluding I&I, will therefore be: 2.34 + 0.22
+ 0.12 = 2.68 m3/sec. The total city population will be 252,975
(or 252.975 thousands of people). The peak and minimum
flow rates can therefore be estimated:
Q peak
Qave
The commercial area will be 30% of 2,500 ha = 750 ha, with a
flowrate of 2.89x10-4m3/sec/ha, the average flow for
commercial areas will therefore be 0.22m3/sec.
The industrial area covers 10% of 2,500 ha = 250 ha, with a
flowrate of 4.63x10-4m3/sec/ha, the average flow for industrial
areas will therefore be 0.12 m3/sec.
5.5
5.5
=
= 2.0
p 0.18 (252.975)0.18
Qmin
0.16
= 0.2 p 0.16 = 0.2(252.975) = 0.48
Qave
The peak flow is therefore estimated to be: 2.0 (2.68 m3/sec)
+ 0.03 m3/sec = 5.39 m3/sec
The minimum flow is estimated to be: 0.48 (2.68 m3/sec) +
0.03 m3/sec = 1.32 m3/sec
The I&I for the entire area is: (1,000 L/ha)(2500 ha) =
2.5x106L/day = 0.03m3/sec
18
Unit
Apartment
Hotel, resident
Individual Dwellings
Average Home
Better Home
Luxury Home
Semimodern Home
Summer Cottage
Person
Resident
Person
Person
Person
Person
Person
Flow, L/unit-day
Range
Typical
200 340
260
150 220
190
190 350
250 400
300 550
100 250
100 240
280
310
380
200
190
Source
Unit
Airport
Automobile Service
Station
Passenger
Vehicle served
Employee
Customer
Employee
Guest
Employee
Employee
Bar
Hotel
Industrial Building
Flow, L/unit-day
Range
Typical
8 15
10
30 50
40
35 60
50
5 20
8
40 60
50
150 220
190
30 50
40
30 65
55
19
Unit
Machine
Wash
Person
Person
Employee
Meal
Resident
Flow, L/unit-day
Range
Typical
1800 2600
2200
180 200
190
90 150
120
190 220
200
30 65
55
8 15
10
90 190
150
Unit
Store, Department
Toilet room
Employee
Parking space
Employee
Shopping Center
Flow, L/unit-day
Range
Typical
1600 2400
2000
30 50
40
28
4
30 50
40
Chin 2000
20
Unit
Hospital, Medical
Bed
Employee
Bed
Employee
Inmate
Employee
Resident
Employee
Hospital, Mental
Prison
Rest Home
Flow, L/unit-day
Range
Typical
500 950
650
20 60
40
300 550
400
20 60
40
300 600
450
20 60
40
200 450
350
20 60
40
Unit
Flow, L/unit-day
Range
Typical
Student
Student
60 115
40 80
80
60
Student
Student
20 - 65
200 400
40
280
Source
Unit
Source
Apartment, Resort
Cabin, Resort
Cafeteria
Campground (Developed)
Person
Person
Customer
Employee
Person
Flow, L/unit-day
Range
Typical
200 280
220
130 190
160
4 10
6
30 50
40
80 150
120
Cocktail Lounge
Seat
50 100
75
Coffee Shop
Customer
Employee
15 30
30 50
20
40
Flow, L/unit-day
Range
Typical
Member present 250 500
400
Employee
40 60
50
Person
40 60
50
Meal served
15 40
30
Dormitory, Bunkhouse
Person
75 175
150
Hotel, Resort
Person
150 240
200
Laundromat
Machine
1800
2600
2200
Country Club
Unit
21
Unit
Store, Resort
Theater
Customer
Employee
Customer
Employee
Seat
Flow, L/unit-day
Range
Typical
5 20
10
30 50
40
20 50
40
30 50
40
10 15
10
Visitor Center
Visitor
15 30
Swimming Pool
20
Wastewater Flow
L/capita-day
Percent
Bathtub Faucet
30.3
12
34.1
14
26.5
11
Lavatory Faucet
11.4
Shower Head
45.4
19
Toilet
94.6
39
Device/System
Device/System
Batch-Flush Valve
Level Controller for Matches the amount of water used to the amount of clothes
Clothes Washer
to be washed.
Dual-Cycle Toilet
Faucet Aerator
Limiting-Flow
Shower Head
Pressure-Reducing
Valve
Recirculating
Mineral Oil Toilet
System
22
Reduced-Flush Device
Urinal
Vacuum-Flush Toilet
System
Wash-Water Recycle
Recycles bath and laundry wastewater for use in toilet
System for Toilet Flushing flushing.
16
28.4
54.9
12
23
26.5
28.4
11
12
85.2
94.6
35
39
L/capita-day
Percent
4.5
60.6
25
94.6
39
22.7
28.4
9
12
23
Main Sewers
Main sewers are used to convey wastewater from
one or more lateral sewers to trunk sewers or to
intercepting sewers
Trunk Sewers
Trunk sewers are large sewers that are used to
convey wastewater from main sewers to treatment or
other disposal facilities, or to large intercepting
sewers.
Interceptor Sewers
Intercepting sewers are large sewers that are used to
intercept a number of main or trunk sewers and
convey the wastewater to treatment or other disposal
facilities
24
25
Map Sources
Preliminary Investigations
26
Sanitary Sewer:
Basic Design Considerations
Wastewater flow
Hydraulic-design equation
Sewer pipe materials
Minimum pipe sizes
Minimum and maximum velocities
Slopes and cover
Evaluation of alternative alignments or designs
Selection of appropriate sewer appurtenances
Ductile Iron
Reinforced Concrete
Pre-stressed Concrete
Polyvinyl Chloride
Vitrified Clay
27
28
Pipe Sizes
Minimum size 8 inches (200 mm)
Smallest sewers should be larger than the
building sewer connections in general use in
the area
Most common size of building connection is 6
inches
Connections of 5 and 4 inches have been used
successfully in some areas
Velocities
Minimum velocity of 2.0 ft/sec (0.6 m/sec)
with flow at full or full depth
Maximum average velocities of 8-10 ft/sec
(2.5-3.0 m/sec) at design depth of flow
Minimum and maximum velocities may be
specified in state and local standards
29
Slope, m/ma
n=0.013
0.0033
0.0025
0.0019
0.0014
0.0011
0.0009
0.0008
0.0007b
0.0006b
0.0004b
Sewer Appurtenances
Primary appurtenances for sanitary sewers:
Manholes
Drop inlets to manholes
Building connections
Junction chambers
30
Manholes
The number of manholes must be adequately
spaced so that the sewers can be easily
inspected and maintained.
For sewers that are 48 and smaller, manholes
should be located at changes in size, slope or
directions.
For larger sewers, these changes may be made
without installing a manhole.
Chin 2000
31
Manhole Size
Large enough to provide easy access to the sewer
Room for a worker to handle a shovel
Bottoms are usually concrete, sloping toward an
open channel which is an extension of the lowest
sewer. Bottom should provide footing for a person
working in the manhole
Manholes in small sewers are usually about 4 feet
in diameter when the sewers have circular cross
sections
In large sewers, larger manholes may be required
to accommodate larger cleaning devices
32
1. Mannings n of 0.013 recommended when analyzing wellconstructed new sewers and 0.015 for most older existing
sewers. This value is based on the use of individual pipe
sections (not less than 1.5 m, 5 ft long) with true and smooth
inside surfaces, and on the assumption that only first-class
construction procedures are used.
- Minimum allowable velocity = 2 ft/sec (0.6 m/sec) at one-half full or full
depth. If access for cleaning is difficult, the minimum velocity should be
3 ft/sec (1 m/sec).
- Maximum allowable velocity = 8 to 10 ft/sec (2.5 to 3.0 m/sec) to
prevent damage to the sewer.
33
Preliminary/Tentative Layout
Manhole Locations
Sewer intersections
Abrupt changes in horizontal direction or slope
Pipe size change locations
Regular intervals along straight runs (for
maintenance)
Less than, or equal to 100 m (300 ft) general rule
500 ft maximum spacing
Exception: sewers that can be walked through
Vertical Location
Note where basement/below-ground service
connections are required
Want to have sewer below basement points so
you dont have to pump!
Also must have minimum required cover:
3 m (10 ft) required in northern states
0.75 m (2.5 ft) or more required in southern states
Vertical Profile
Ground surface
Street surface (where applicable)
Tentative manhole locations
Elevations of important subsurface strata such as rock
Boring locations
Underground structures
Basement elevations
Cross streets
Plan of the sewer line
34
Given:
Flow
Velocity
Minimum pipe size
Ground elevations and slope
Pipe material and roughness
Minimum pipe cover
Type of
development
Saturation population
density
Wastewater flows
Persons/ha Persons/ac
L/capita- Gal/capitaday
day
Resid.
Single-family
houses
38
15
300
80
Resid.
Duplexes
60
24
280
75
Resid.
Low-rise
apartments
124
50
225
60
35
Area
Design.
Development
type
A-1
A-2
Average WW
flow (m3/day)
Area (ha)
WW flows
(L/cap.-day)
S-Family
100
38
300
1140
S-Family
112
38
300
1276.8
A-3
S-Family
112
38
300
1276.8
A-4
Mix Resid.
114
(38+60+124)/3 =
74
(300+280+225)/
3 = 268.3
2263.7
A-4
School
16
2000
75
150
A-5
Comm.
110
20 m3/ha-day
2200
A-6
Ind.
110
30 m3/ha-day
3300
A-7
Low-rise
Apart.
70
124
225
1953
A-8
Low-rise
Apart.
60
124
225
1674
A-9
Low-rise
Apart.
48
124
225
1339.2
A-10
Shopping
Center
48
20 m3/ha-day
960
Line
UpNumber stream
Manhole
Downstream
Manhole
Feeder
Areas
Cum. Av. WW
Flow (Land
Use) (m3/day)
Peaking
Factor
Peak WW Flow
(Land Use)
(m3/day)
A-1
A-2
A-10
Res. 2417
Com. 960
2.9
1.8
R: 7009
C: 1728
Total: 8737
A-9
Res. 1339
3.0
4017
A-3
Res. 1277
3.0
3831
A-8
Res. 1674
3.0
5022
A-4
Res. 2264
School 150
2.9
R:6566
S: 600
Total: 7166
A-7
A-5
Res. 1953
Com. 2200
2.9
1.8
R: 5664
C: 3960
Total: 9624
A-6
Ind. 3300
2.1
6930
36
Calculate Peak Daily Flows Entering Each Pipe Segment (with I&I)
Line #
Feeder
Areas
Infiltration
Area (ha)
Infiltration
Allowance
(m3/ha-day)
Infilt.
(m3/day)
Peak WW
Flow
(m3/day)
Peak Flow
(m3/day)
A-1
A-2
A-10
100
112
(0.5)48
Total: 236
5.4
1274
8737
10011
A-9
(0.5)48
Total: 24
8.75
210
4017
4227
A-3
112
7.6
8512
3831
12343
A-8
60
8.0
480
5022
5502
A-4
R: 114
S: (0.5)16
Total: 122
7.6
927
7166
8093
A-7
A-5
70
(0.5)110
Total: 125
7.6
950
9624
10574
A-6
(0.5)110
8.0
440
6930
7370
In-Pipe Flow
(m3/day)
Entering
Flow
(m3/day)
Cumulative
Flow
(m3/day)
Cumulative
Flow
(m3/sec)
10011
10011
0.116
10011
4227
14238
0.165
14238
12343
26581
0.308
26581
5502
32083
0.371
32083
8093
40176
0.465
The next larger commercial pipe size is 525 mm, which has a
full flowing capacity of 10,011 m3/day with this slope and
roughness:
40176
10574
50750
0.587
Line
Number
Cumulative
Flow (m3/sec)
Slope
(m/m)
50750
7370
58120
0.673
0.116
0.0019 0.462
Line
Number
Feeder
Line
None
0.375
(0.0019)0.5
Exact
Diameter (m)
0.375
= 0.462m
Pipe
Diameter
(mm)
Full Flow
(m3/day)
525
10011
37
Calculate the pipe diameter assuming these peak flows are sewer
flowing full conditions. Assume Mannings n of 0.015 and slopes
as shown in the table (slopes are typically determined from postgrading topographic maps of an area).
Line
Number
Cumulative
Flow (m3/sec)
Slope
(m/m)
Exact
Diameter
(m)
Pipe
Diameter
(mm)
Full Flow
(m3/day)
0.116
0.0019
0.462
525
13995
0.165
0.0015
0.528
600
17803
0.308
0.0012
0.667
675
26581
0.371
0.0011
0.716
750
32083
0.465
0.0010
0.779
900
40176
1D
V full =
n 4
0.587
0.0007
0.849
900
50750
0.673
0.0009
0.894
900
58120
2/3
S 0.5 =
1 0.525m
0.015 4
2/3
Q
0.116m 3 / sec (86,400 sec/ day )
=
= 0.716
Q full
13,995m 3 / day
V
= 0.96 from hydraulic elements figure
V full
d/D = 0.72
Q/Qfull = 0.72
V/Vfull = 0.96
38
Example
Sewer Profile
39
40
41
Elevation
Slope =
Length
Street
Street
Pipe
Elevation Elevation Length
Up (ft)
Down (ft) (ft)
Slope
10
16
17
116.37
112.57
380
0.010
11
17
18
112.57
108.89
400
0.009
12
18
108.89
105.33
405
0.009
13
13
14
115.80
111.92
400
0.010
14
14
15
111.92
108.58
380
0.009
15
15
108.58
105.33
411
0.008
16
105.33
104.18
230
0.005
17
104.18
101.30
600
0.005
Street
Street
Pipe
Slope
Elevation Elevation Length (ft)
Up (ft)
Down (ft)
116.60
112.19
630
0.007
112.19
109.23
470
0.006
115.04
112.04
390
0.008
112.04
109.23
385
0.007
109.23
107.25
330
0.006
10
11
117.46
113.77
410
0.009
11
12
113.77
110.29
400
0.009
12
110.29
107.25
380
0.008
107.25
105.33
370
0.005
42
Contributing
Area (ac)
Infiltration Rate
(gal/acres/day)
Infiltration
Amount (gal/day)
87
600
52200
5.1
600
3060
12.1
600
Pipe No.
Contributing
Area (ac)
Infiltration Rate
(gal/acres/day)
Infiltration
Amount
(gal/day)
600
10
600
3000
11
4.9
600
2940
12
4.3
600
2580
13
13.1
600
7860
7260
14
5.3
600
3180
600
15
9.7
600
5820
4.8
600
2880
16
600
8.7
600
5220
17
600
6.3
600
3780
4.7
600
2820
Number of
People
(persons/acre)
Sewage per
Person
(gal/cap./day)
Average
Sewage per
Pipe (gal/day)
40
100
40
100
20000
11
4.9
40
100
19600
12
4.3
40
100
17200
20400
13
13.1
40
100
52400
100
48400
14
5.3
40
100
21200
40
100
15
9.7
40
100
38800
Number of
People
(persons/acre)
Sewage per
Person
(gal/cap./day)
Average Sewage
per Pipe
(gal/day)
87
40
100
348000
5.1
40
100
12.1
40
Contributing
Area (ac)
10
Contributing
Area (ac)
Pipe
No.
Pipe
No.
9
4.8
40
100
19200
16
40
100
8.7
40
100
34800
17
40
100
6.3
40
100
25200
4.7
40
100
18800
43
Up
Manhole
Down
Manhole
Avg
Design
Total
Flow
Flow
(gal/day)
(gal/day)
1200600
Design
Flow
(ft3/sec)
1.86
Cum
Design
Flow
(ft3/sec)
400200
1.86
23460
70380
0.11
1.97
55660
166980
0.26
0.26
0.00
0.26
22080
66240
0.10
2.23
10
11
40020
120060
0.19
0.19
11
12
28980
86940
0.13
0.32
12
21620
64860
0.10
0.42
Pipe
No.
Up
Manhole
Down
Manhole
Design
Flow
(ft3/sec)
Cum.
Design Flow
(ft3/sec)
0.00
2.65
10
16
17
23000
69000
0.11
0.11
0.21
11
17
18
22540
67620
0.10
12
18
19780
59340
0.09
0.30
13
13
14
60260
180780
0.28
0.28
14
14
15
24380
73140
0.11
0.39
15
15
44620
133860
0.21
0.60
16
3.55
17
3.55
18. Calculate full pipe flow rate using Mannings equation and
pipe diameters from Step 17.
Pipe
No.
Cumulative Mannings
Design Flow
n
(ft3/sec)
Slope
Calculated Actual
Exact
Pipe
Diameter Diameter
(in)
(in)
Full
Pipe
Flow,
Qfull
(ft3/sec)
1.86
0.013
0.007
10.04
12
2.99
1.97
0.013
0.006
10.46
12
2.84
0.26
0.013
0.008
4.71
1.06
0.26
0.013
0.007
4.75
1.04
2.23
0.013
0.006
11.06
12
2.77
0.19
0.013
0.009
4.04
1.15
0.32
0.013
0.009
4.98
1.13
0.42
0.013
0.008
5.61
1.08
44
Pipe
No.
Cumulative Mannings
Design Flow
n
(ft3/sec)
Slope
Calculated Actual
Exact
Pipe
Diameter Diameter
(in)
(in)
Full
Pipe
Flow,
Qfull
(ft3/sec)
2.65
0.013
0.005
12.12
15
4.67
10
0.11
0.013
0.010
3.22
1.21
11
0.21
0.013
0.009
4.22
1.16
12
0.30
0.013
0.009
4.87
1.14
13
0.28
0.013
0.010
4.64
1.19
14
0.39
0.013
0.009
5.37
1.14
15
0.60
0.013
0.008
6.42
1.08
16
3.55
0.013
0.005
13.63
15
4.58
17
3.55
0.013
0.005
13.73
15
4.49
Pipe
No.
9
10
11
12
13
14
15
16
17
4.67
1.21
1.16
1.14
1.19
1.14
1.08
4.58
4.49
15
8
8
8
8
8
8
15
15
Afull
(ft2)
Vfull Qdesign/
(ft/sec) Qfull
3.80
3.47
3.33
3.25
3.42
3.25
3.09
3.73
3.66
0.57
0.09
0.18
0.27
0.23
0.35
0.56
0.77
0.79
2.99
2.84
1.06
1.04
2.77
1.15
1.13
1.08
12
12
8
8
12
8
8
8
0.785
0.785
0.524
0.524
0.785
0.524
0.524
0.524
3.81
3.61
3.04
2.97
3.52
3.29
3.24
3.11
0.62
0.69
0.24
0.25
0.80
0.16
0.28
0.39
Afull (ft2)
Vfull
(ft/sec)
D (in)
d/D
V/Vfull
0.62
0.785
3.81
12
0.57
1.05
0.69
0.785
3.61
12
0.62
1.08
0.24
0.524
3.04
0.30
0.75
0.25
0.524
2.97
0.30
0.75
0.80
0.785
3.52
12
0.68
1.12
0.16
0.524
3.29
0.28
0.69
0.28
0.524
3.24
0.31
0.78
0.39
0.524
3.11
0.43
0.93
Pipe
No.
0.982
0.524
0.524
0.524
0.524
0.524
0.524
0.982
0.982
1.86
1.97
0.26
0.26
2.23
0.19
0.32
0.42
45
Pipe
No.
Qdesign/Qfull
Afull (ft2)
0.57
0.982
Vfull
(ft/sec)
D (in)
3.80
V/Vfull
d/D
15
0.56
10
0.09
0.524
3.47
0.20
0.56
0.18
0.524
3.33
0.24
0.68
13
0.27
0.524
0.23
0.524
3.25
3.42
0.36
0.34
0.84
0.81
14
0.35
0.524
3.25
0.41
0.89
15
0.56
0.524
3.09
0.55
1.03
16
17
0.77
0.982
0.79
0.982
3.73
15
3.66
0.67
15
0.68
1.12
1.12
V/Vfull
Depth at
Design
Flow (in)
Velocity at
Design
Flow
(ft/sec)
0.56
1.03
8.40
3.92
0.20
0.56
1.60
1.94
0.24
0.68
1.92
2.26
0.36
0.84
2.88
2.73
3.42
0.34
0.81
2.72
2.77
0.524
3.25
0.41
0.89
3.28
2.90
0.524
3.09
0.55
1.03
4.40
3.18
16
0.982
3.73
15
0.67
1.12
10.05
4.18
17
0.982
3.66
15
0.68
1.12
10.20
4.10
Vfull D (in)
(ft/sec)
Pipe
No.
Afull
(ft2)
0.982
3.80
15
10
0.524
3.47
11
0.524
3.33
12
0.524
3.25
13
0.524
14
15
d/D
Pipe
No.
Afull
(ft2)
Vfull
(ft/sec)
D
(in)
d/D
V/Vfull
Depth at
Design
Flow (in)
Velocity at
Design Flow
(ft/sec)
0.785
3.81
12
0.57
1.05
6.84
4.00
0.785
3.61
12
0.62
1.08
7.44
3.90
0.524
3.04
0.30
0.75
2.40
2.28
0.524
2.97
0.30
0.75
2.40
2.22
0.785
3.52
12
0.68
1.12
8.16
3.95
0.524
3.29
0.28
0.69
2.24
2.27
0.524
3.24
0.31
0.78
2.48
2.53
0.524
3.11
0.43
0.93
3.44
2.89
1.03
11
12
22. Calculate design depth (d) and design velocity (V) from
ratios from partial-flow diagram.
Last Steps!
23. Check velocities at the design flows to ensure that
they are greater than 2 ft/sec. In this example, Pipe
#10 has a calculated 1.9 ft/sec velocity. The slope of
the pipe could be increased, with resulting trench
depths, but this calculated value is close enough to
the desired outcome considering the method used.
Computerized design methods have smaller rounding
errors and are more convenient when adjusting the
slope to meet the targeted velocity value. Obviously,
regulatory agency approval is needed if the
minimum velocity criterion is not met, as increased
maintenance may be needed.
24. Draw profiles, considering the final pipe depths and
extra trench dimensions. Ensure that subsurface
obstructions are cleared.
46
Pipe Bedding
Sewer Construction
Two types of sewer materials: flexible and
rigid.
Rigid: asbestos-cement, cast iron, concrete,
vitrified clay
Flexible: ductile iron, fabricated steel, corrugated
aluminum, thermoset plastic (PE, PVC).
47
Sewer Construction
Sewer Construction
Loads on sewer lines affected by conditions of
flow, groundwater, adjacent earth, and
superimposed situation.
Loads include hydraulic loads, earth loads,
groundwater loads, and superimposed loads.
Therefore, crushing strength of sewer material,
type of bedding and backfill load are all
important.
Sewer Construction
Calculation of load coefficient
C=
where
1 e 2 k '( H / B )
2k '
W = CwB 2
where
Sewer Construction
Load on sewer conduit for trench condition is affected directly by
soil backfill.
Load varies widely over different soil types, from minimum of
100 lb/ft3 (1600 kg/m3) to maximum of about 135 lb/ft3 (2200
kg/m3).
Design minimum of 120 125 lb/ft3 (1900 or 2000 kg/m3).
Unit weight, w
100 lb/ft3 (1600 kg/m3)
115 lb/ft3 (1840 kg/m3)
120 lb/ft3 (1920 kg/m3)
130 lb/ft3 (2080 kg/m3)
Material description
Dry sand AND sand and
damp topsoil
Saturated topsoil AND
ordinary sand
Wet sand AND damp clay
Saturated Clay
48
Sewer Construction
Load also influenced by coefficient of friction between
backfill and side of the trench () and by coefficient of
internal friction in backfill soil ().
Sewer Construction
Common cuts for sewer pipe installations.
For design purposes, these are often set equal to each other.
But if the backfill is sharp sand and the sides of the trench are
sheeted with finished lumber, may be substantially greater
than .
49
Bedding
Conditions
for
Concrete
Pipe
Note: 21
inch
concrete
pipe not
normally
available
McGhee 1991
McGhee 1991
External Loads
Allowable loads based on cracking do not usually need a safety factor as the ratio
of ultimate load to cracking load is approximately 1.5 for reinforced concrete pipes.
McGhee 1991
50
McGhee 1991
McGhee 1991
Solution:
This is a short load as it crosses the trench. The load applied by the
structure is:
F = 1340 kg/m (1.22 m) = 1635 kg
The pressure applied to the soil above the pipe is:
P = 1635 kg/0.91 m = 1795 kg/m
The ratio of depth to width is 1.83/1.22 = 1.5. From the table for short loads
for this depth to width ratio and damp clay, the maximum proportion of the
load reaching the pipe will be 0.51. Therefore, the load reaching the pipe will
be:
P = 1795 kg/m (0.51) = 915 kg/m which must be added to the static
load from the fill material.