You are on page 1of 2

SEISMIC SLIDING BEARING

INSPECTION &
MAINTENANCE PROGRAM

PREPARED BY:

DYNAMIC ISOLATION SYSTEMS, INC.

Dynamic Isolation Systems, Inc.


885 Denmark Drive, Suite 101 McCarran, NV 89434 USA
Tel: 775-359-3333 Fax: 775-359-3985
www.dis-inc.com

Inspection and Maintenance Program


Sliding Bearings are maintenance free devices. These guidelines pertain to checking the
surroundings of sliders, maintaining clearances and visual inspections. The following general
maintenance guidelines shall be carried out, at a minimum, every 1 year of use. In addition, the
isolators shall be inspected after any seismic event. Further, after any extreme or unusual event
(local fire, flooding, etc.) sliders shall be inspected.

Routine Inspection and Maintenance Program


There shall be no obstruction which prevents the movement of the sliders horizontally in any
direction. The area around each slider shall be cleaned of all debris and construction materials.
The stainless steel sliding surface shall be kept free of any dust, dirt, or rust build up. If there is
any build up on the stainless steel, it should be cleaned immediately to allow for free sliding of the
bearing during a seismic event. Any basic solvent such as automotive brake cleaner can be used
to clean the surface. If there is a moat around the structure, it also shall be free of any debris or
obstructions.

Post-Event Inspection and Maintenance Program


1. All checks in the Routine Inspection and Maintenance Program shall be performed.
2. If any unusual surface features are seen, DIS should be notified.
3. In case of a fire near the sliders, inspection of the sliders shall be performed.

Slidingsurfacecleanand
clearofdebrisandarea
surroundingsliderisclear.

Dynamic Isolation Systems, Inc.


885 Denmark Drive, Suite 101 McCarran, NV 89434 USA
Tel: 775-359-3333 Fax: 775-359-3985
www.dis-inc.com

You might also like