You are on page 1of 1

Quiz#1

INSTRUMENTATION & MEASUREMENT


B. Tech Electronics Engineering 2nd year
On all questions: SHOW ALL WORK. BEGIN WITH FORMULAS, THEN SUBSTITUTE VALUES
AND UNITS. No credit will be given for numbers that appear without justification. Read the
entire quiz before answering any questions.
1. A digital voltmeter has a read-out range from 0-9,999 counts. The resolution of the
instrument for full scale reading of 9.999V is _____________
(A) 11 mV

(B) 11 V

(C) 1mV

(D) 1 V

2. An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The
current measured is 5 A. The limiting error is
A.

2%

B.

2.5%

C.

4%

D.

5%

3. The coil of a moving iron instrument has a resistance of 500 and an inductance of 1 H. It
reads 250 V when a 250 V dc is applied. If series resistance is 2000 , its reading when fed
by 250 V, 50 Hz ac will be
A.

260 V B.

252 V C.

250 V D.

248 V

4. A moving coil instrument has a resistance of 0.6 and full scale deflection at 0.1 A. To
convert it into an ammeter of 0-15 A range, the resistance of shunt should be
A.

0.6

B.

0.06

C.

0.1

D.

0.004

5. In the circuit shown in Figure 3.19, the current flowing between A and B is measured by an
ammeter whose internal resistance is 100 Ohm. What is the measurement error caused by
the resistance of the measuring instrument?

You might also like