PIPING STRESS ANALYSIS REPORT GOSPA

Ferrostaal
DOCUMENT NO.
CLIENT/PROJECT

NOV:
016189_GA_S1B

Rev.0

Longitudinal stress [MPa]

Allowable Stress Diagram


30 years design life (Operating) at 60 degC
Part factor f2=0.83

65
60
55
50
45
40
35
30
25
20
15
10
5
0
0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

Hoop stress [MPa]

Design Life (yrs)


30
Material
GRE, Ameron Product Series 3416
Temp
60
21
60
LTHS ,MPa
146,4
146,38
146,38
Sas(2:1),MPa
108,8
125
108,8
Sas(0:1),MPa
56,9
65
56,9
Sa(2:1),MPa
73,2
73,19
73,19
Sa(0:1),MPa
38,3
38,06
38,28
f2
Sa(2:1),MPa
Sa(0:1),MPa
LTHS,MPa

0,83
60,75
31,77
121,50

}*

66
146,38
106,25
55,6
73,19
38,32

80
129,43
100,42
52,7
64,72
33,97

idealised curve with out f2 Hoop Stress Longitudianal Stress


pt 1
0,00
38,06
pt 2
146,38
73,19
pt 3
146,38
0,00

93
113,70
95
50
56,85
29,92

idealised curve with f2


pt 1
pt 2
pt 3

NOTE-1

NODE
Legend:
d
LTHS
Sas(2:1)=
Sas(0:1)=
Sa(2:1)=
Sa(0:1)=

= Plotted as per section 6.2 of report for Load Case


=Long Term Hydrastatic Design Stress
=Short Term Axial Strength at (2:1) Stress Ratio
=Short Term Axial Strength at (0:1) Stress Ratio
=Long Term Axial Strength at (2:1) Stress Ratio
=Long Term Axial Strength at (2:1) Stress Ratio

Result = Pass
Allowable stress at hoop (L2)
a
0,238506
b
31,77

L2

Operational

39,14 MPa

74,9

% Allowable

NOTES:
The Sa (2:1), Sa(0:1) & LTHS at part factor F2=

0,83

is calculated by multiplying factor (0.83)

5129

with corresponding allowable.

Hoop Stress Longitudianal Stress


0,00
31,77
121,50
60,75
121,50
0,00
Hoop Stress
(Mpa)
30,88

Code Stress
(Mpa)
29,3