You are on page 1of 1

PIPING STRESS ANALYSIS REPORT GOSPA

Ferrostaal
DOCUMENT NO.
CLIENT/PROJECT

NOV:
016189_GA_S1B

Rev.0

Longitudinal stress [MPa]

Allowable Stress Diagram


30 years design life (Sustained) at 21 degC
Part factor f2=0.67
55
50
45
40
35
30
25
20
15
10
5
0
0

10

20

30

40

50

60

70

80

90

100

110

Hoop stress [MPa]


Design Life (yrs)
30
Material
GRE, Ameron Product Series 3416
Temp (degC)
21
21
45
LTHS ,MPa
146,4
146,38
146,38
Sas(2:1),MPa
125,0
125
115,0
Sas(0:1),MPa
65,0
65
60,0
Sa(2:1),MPa
73,2
73,19
73,19
Sa(0:1),MPa
38,1
38,06
38,19
f2
Sa(2:1),MPa
Sa(0:1),MPa
LTHS,MPa

0,67
49,04
25,50
98,07

66
146,38
106,25
55,6
73,19
38,32

80
129,43
100,42
52,7
64,72
33,97

idealised curve with out f2 Hoop Stress Longitudianal Stress


pt 1
0,0
38,0588
pt 2
146,4
73,19
pt 3
146,4
0

93
113,70
95
50
56,85
29,92

idealised curve with f2


pt 1
pt 2
pt 3

}*

NOTE-1

NODE
Legend:
d
LTHS
Sas(2:1)=
Sas(0:1)=
Sa(2:1)=
Sa(0:1)=

= Plotted as per section 6.2 of report for Load Case


=Long Term Hydrastatic Design Stress
=Short Term Axial Strength at (2:1) Stress Ratio
=Short Term Axial Strength at (0:1) Stress Ratio
=Long Term Axial Strength at (2:1) Stress Ratio
=Long Term Axial Strength at (2:1) Stress Ratio

Result = Pass
Allowable stress at hoop (L3)
a
0,24
b
25,50

33,61 MPa

3
NOTES:
The Sa (2:1), Sa(0:1) & LTHS at part factor F2=

L3

Sustainable

59,5

% Allowable

0,67

is calculated by multiplying factor (0.67)

8235

with corresponding allowable.

Hoop Stress Longitudianal Stress


0
25,50
98,0746
49,04
98,0746
0
Hoop Stress
(Mpa)
33,78

Code Stress
(Mpa)
20,01