PIPING STRESS ANALYSIS REPORT GOSPA

Ferrostaal
DOCUMENT NO.
COMPANY/PROJECT

NOV:
016189_GA_S1B

Rev.0

Longitudinal stress [MPa]

Allowable Stress Diagram


30 years design life (Occassional) at 60 degC
Part factor f2=0.89
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

Hoop stress [MPa]

Design Life (yrs)


30
Material
GRE, Ameron Product Series 3416
Temp
60
21
60
66
LTHS ,MPa
146,4
146,38
146,38
146,38
Sas(2:1),MPa
108,8
125
108,8
106,25
Sas(0:1),MPa
56,9
65
56,9
55,6
Sa(2:1),MPa
73,2
73,19
73,19
73,19
Sa(0:1),MPa
38,3
38,06
38,28
38,32
f2
Sa(2:1),MPa
Sa(0:1),MPa
LTHS,MPa

Legend:
d
LTHS
Sas(2:1)=
Sas(0:1)=
Sa(2:1)=
Sa(0:1)=

0,89
65,14
34,07
130,28

}*

80
129,43
100,42
52,7
64,72
33,97

NOTE-1

= Plotted as per section 6.2 of report for Load Case


=Long Term Hydrastatic Design Stress
=Short Term Axial Strength at (2:1) Stress Ratio
=Short Term Axial Strength at (0:1) Stress Ratio
=Long Term Axial Strength at (2:1) Stress Ratio
=Long Term Axial Strength at (2:1) Stress Ratio

Result = Pass
Allowable stress at hoop (L4)
a
0,238506
b
34,07

41,43 MPa

NOTES:
The Sa (2:1), Sa(0:1) & LTHS at part factor F2=

93
113,70
95
50
56,85
29,92

L9

Occasional windload

72,4

% Allowable

0,89

is calculated by multiplying factor (0.89)

idealised curve with out f2


pt 1
pt 2
pt 3

Hoop Stress Longitudianal Stress


0,0
38,0588
146,4
73,19
146,4
0

idealised curve with f2


pt 1
pt 2
pt 3

Hoop Stress Longitudianal Stress


0
34,07
130,2782
65,14
130,2782
0

NODE
5129

with corresponding allowable.

Hoop stress
(Mpa)
30,88

Code Stress
(Mpa)
30,01