You are on page 1of 1

Use menu item Settings > Printing & Title Block

to set these five lines of information


for your program.

Project
Title
Page: ______
Title
:
Job #
Project
Numb Dsgnr: Designer Nam
Date: 15 OCT 2014
:
Description....
Enter any descriptive information you wish into this area

This Wall in File: c:\users\user\documents\retainpro 10 project files\we ots r1.RPX


RetainPro 10 (c) 1987-2014, Build 10.14.9.12
License : --Unassigned-

Soldier Pile Retaining Wall Design

License To : UNLICENSED DEMO USER, DEMO EXPIRES IN 45 DAYS

Code: IBC 2006,ACI 318-05,ACI 530-05

Summary

Wall height (retained height), ft

10.00

Backfill slope

18.40

Soil Density, pcf

110.00

Soil Phi angle

34.00

Ka (horizontal)

0.31

Surcharge, psf

100

Allow. Passive, psf / ft. depth

389

Apply S.F. to Passive

1.5

Pile Spacing, ft

8.0

Drilled Diameter, in.

24.00

Multiplier to Passive Wedge

2.5

Required Embedment, ft

15.14

Embedment Used, ft

16.00

Moment in Pile Max, ft-lbs


Max. Mom. Factored 1.6, LRFD
Soldier Beam Selection

111,739
178,783
W10x49

Lagging Depth, ft
Lagging Selection

Thumbnail

0.00
4x12

Selected option to drill hole, insert soldier beam, and encase beam in lean concrete.