You are on page 1of 35

DESIGN AND ANALYSIS

OF
MULTI-STORIED BUILDING
By :
K.Uday kumar(09245A0103)
K.Nagendra babu(08241A0123)
Md.Khaja taqiuddin(08241A0117)

CONTENTS
1.
2.
3.
4.
5.
6.
7.

INTRODUCTION
CODES
STATEMENT OF THE PROJECT
LOADS ON THE STRUCTURE
OBJECTIVE OF STRUCTURAL DESIGN
DESIGN AND ANALYSIS
REFERENCES

INTRODUCTION
Our

project is based on the design and analysis


of the multi-storied building.
Analysis
Notation

is done through using the STAAD-PRO.

adopted through out the project is


same as in IS-456-2000.

CODES
z IS-456:2000

:DESIGN CODE FOR RCC


STRUCTURES

z IS-875(PART1)

:CODE FOR DEAD LOADS

z IS-875(PART2)

:CODE FOR IMPOSED LOADS

z IS-875(PART3)

:CODE FOR WIND LOADS

STATEMENT OF THE PROJECT :

1.Utility of building : Residential buildng


z 2. No of storeys :
G+5
z 3.Shape of the building: Rectangular
z 4.No.of staircases : 6 nos
z 5.Type of walls : Brick wall
z

Geometric details :
Ground Floor :
9.0 MFloorFloor Height :
3.0 M
Height of Plinth:
0.6 M above G.L
Depth of Foundation:2 M below G.L

Material details :
Concrete Grade
:
M25
Grade of steel
:
HYSD
REINFORCEMENT of Grade Fe415
Bearing Capacity of Soil :
200 KN/M2
Type Of Construction
:
R.C.C
framed structure

DIFFERENT TYPES OF LOADS ON THE


STRUCTURE
zDead

loads
zImposed loads
zWind loads

Dead loads
zInvolves

selfweight of
zRCC slab
zBeams & columns
zPlinth
zWalls

Imposed loads
zImposed

also known live loads


zLoad over the floor i.e. load of
persons it is calculated as 0.2 kN/m2
zThis load is applied over the length
of structure

Wind loads
z Wind

is air in motion

z Wind

loads are calculated according to


IS:875(part 3)

z Intensity

of wind and exposure are applied


in the directions as required

TYPES OF LOADS IMAGE VIEW

Load combinations
zThe

structure should be analysed for


combination of loads as in practice
we have number of loads in various
directions act
zSome of the combinations to be
checked are
z1.5(DL+LL)
z1.5(DL+WL)

OBJECTIVES OF STRUCURAL DEIGN


Structure designed should satisfy the
criteration of ultimate strength.
Structure should satisfy the servicablity
It should satisfy the stablity against
overturning , sliding , and buckling.

The main objective of the design are


z Foundation

design
z Column design
z Beam design
z Slab design

DESIGN PRINCIPLE, ASSUMPTION AND


NOTATION ASSUMED
z

The notation adopted throughtout the work is same as in


IS 456-2000
ASSUMPTION IN DESIGN
Using partial safety factors for loads in accordance with
clause 36.4 of IS 456-2000
Partial safety factor for material in accordance with
clause 36.4.2 IS 456-2000 is taken as 1.5 for concrete
and 1.15 for steel
Using partial safety factors in accordance with clause
36.4 of IS 456-2000 combination of load
(D.L +L.L) 1.5
(D.L +L.L +W.L) 1.2

Density of materials used


MATERIAL
i) Plain concrete
ii) Reinforced
iii) Flooring material (c.m)
iv) Brick masonry
v) Fly ash

Density
24.0 KN/m3
25.0 KN/m3
20.0KN/m3
19.0KN/m3
5.0KN/m3

LIVELOADS: In accordance with IS 875-86


i)
Live load on slabs
=
ii)
Live load on passage
=
iii
Live load on stairs
=

3.0KN/m2
3.0KN/m2
3.0KN/m2

Structural design
For slabs,Depth is 130 mm provided & min
depth is 90mm
Factored Load on slab is 12Kn/m
For beams,after calculations are done.the
Dimensions of beam is 230*350mm
Factored load on beam is 15.87Kn/m

Shape of column is Rectangular


z For columns, the dimension of column is
230*500mm
z Factored load on column 1090.10KN
z

For footings, the bering capacity of soil is


200Kn/m2
z To provide the dimension of footing is
1.5m*2.7m

ANALYSIS
z Analysis

is done using STAAD PRO


developed by BENTLEY
z Once the loads and load combinations are
assigned to the structure, analysis is to be
done
z Analysis is done for RCC structure

Assign the properties of structure

ASSIGN LOADS ON THE SLAB

Load assign on the walls

Assign wind load on the structure

RCC analysis
z

Code is assigned as IS:456-2000

The parameters are assigned to the structure

Commands to be given are


z
z

concrete design
Member takeoff

Conclusions
Staad pro become more and more critical
in the analysis of engineering & scientific
problems
z This facilities for the implementations of
more effective & professional engineering
software
z It should be affordable to promote their
wide spread usage amongst civil engg at a
global scale
z

REFERENCES
z Structural

analysis by S.RAMAMRUTHAM

z IS456-2000
z AUTO

CODE used

CAD & STAAD PRO packages

z Design

of RCC structures by B.C PUNMIA

Thank you!