Professional Documents
Culture Documents
57-106.3 Eclipse Model 706
57-106.3 Eclipse Model 706
High Performance
Guided Wave Radar
Level Transmitter
DESCRIPTION
APPLICATIONS
MEDIA: Liquids, solids, or slurries; hydrocarbons to waterbased media (Dielectric Constant r = 1.2100)
VESSELS: Most process or storage vessels up to rated
probe temperature and pressure.
CONDITIONS: All level measurement and control applications including process conditions exhibiting visible
vapors, foam, surface agitation, bubbling or boiling, high
fill/empty rates, low level and varying dielectric media or
specific gravity.
FEATURES
Multivariable, two-wire, 24 VDC loop-powered transmitter for level, interface, volume, or flow.
Diode switching technology offers best-in-class signal
strength and signal-to-noise ratio (SNR) resulting
in enhanced capability in difficult low dielectric
applications.
Level measurement not affected by changing media
characteristics.
No need to move levels for calibration.
Overfill Capable probes allow for true level measurement all the way up to the process seal, without
the need for special algorithms.
4-button keypad and graphic LCD display allow for
convenient viewing of configuration parameters and
echo curve.
Proactive diagnostics advise not only what is wrong,
but also offer troubleshooting tips.
Nine common tank shapes for volumetric output.
TECHNOLOGY
PRINCIPLE OF OPERATION
ECLIPSE Guided Wave Radar is based upon the technology
of TDR (Time Domain Reflectometry). TDR utilizes pulses
of electromagnetic energy transmitted down a wave guide
(probe). When a pulse reaches a surface that has a higher
dielectric constant than the air (r = 1) in which it is traveling, a portion of the pulse is reflected. The transit time
of the pulse is then measured via high speed timing
circuitry that provides an accurate measure of the liquid
(or solids) level. The amplitude of the reflection depends
on the dielectric constant of the product. The higher the
dielectric constant, the larger is the reflection.
Initial
Pulse
Initial
Pulse
Reflected
Pulse
Air
Liquid
r = 1
Air r = 1
r > 1.2
Reflected
Pulse
r > 1.2
Transmitted
Pulse
Transmitted
Pulse
INTERFACE MEASUREMENT
The ECLIPSE Model 706 is capable of measuring both an
upper liquid level and an interface liquid level. As only a
portion of the pulse is reflected from a low dielectric upper
surface, some of the transmitted energy continues down
the GWR probe through the upper liquid. The remaining
initial pulse is again reflected when it reaches the higher
dielectric lower liquid. It is required that the upper liquid
has a dielectric constant less than 10, and the lower liquid
has a dielectric constant greater than 15. A typical interface
application would be oil over water, with the upper layer
of oil being non-conductive (r 2.0), and the lower layer
of water being very conductive (r 80). The thickness of the
upper layer could be as small as 2" (50 mm) while the maximum upper layer is limited to the length of the GWR probe.
2
Reference
Signal
Air r = 1
Upper level
signal
Interface
level signal
Time
Interface Level
SPECIAL
APPLICATIONS
EMULSION LAYERS
OVERFILL CAPABILITY
Knowing exactly where the target is located at room temperature, and then continuously monitoring its apparent
location, the vapor space dielectric can be back-calculated.
Knowing the vapor space dielectric, accurate compensation of the actual liquid level reading is accomplished.
This is a patented technique with two US Patents
(US 6642801 and US 6867729) issued for both the mechanical target concept and the associated software algorithm.
Contact the factory for additional information relating to
saturated steam applications.
PROBE
THREE
OVERVIEW
STYLES
OF
GWR
PROBES
With one basic ECLIPSE Model 706 transmitter that operates with all probes, choosing the proper Guided Wave
one can choose the probe type that will offer optimal
performance.
The descriptions below are facts relating to the physics of
GWR technology and are not specific to the ECLIPSE
Model 706.
COAXIAL PROBES
Figure 1
Coaxial Probe
PROBE
THREE
OVERVIEW
STYLES
OF
CONTINUED
GWR
PROBES
OPTIONAL FLUSHING
CONNECTION
The maintenance of coaxial GWR probes in applications
suffering from buildup or crystallization can be significantly improved by using an optional flushing connection.
This flushing connection is a metal extension with a port
welded above the process connection. The port allows
the user to purge the inside of the coaxial GWR probe
during routine maintenance.
Note: The best approach to eliminate the effects of
condensation or crystallization is to install
adequate insulation or heat tracing (steam or
electrical). A flushing connection is no substitute for proper maintenance, but will help
to reduce the frequency of the intervention.
Flushing Port
Shown Plugged
PROBE
THREE
OVERVIEW
STYLES
OF
CONTINUED
GWR
PROBES
Figure 2
Twin Flexible Probe
Figure 3
Single Rod Probe
Launch Plate
PROBE
SELECTION
GUIDE
TWIN CABLE GWR PROBE
signal propagation
signal propagation
La
end view
GWR
Description
Probe
7yT
7yP
7yD
7yS
7yG
7yL
7yJ
7yF
7yM
7yN
Installation
Dielectric
Range
Temperature
Range
Max.
Overfill
Vacuum
Pressure
Safe
Viscosity
cP (mPa.s)
1000 psi
(70 bar)
6250 psi
(431 bar)
6250 psi
(431 bar)
1275 psi
(88 bar)
Yes
Yes
500/2000
Full
Yes
500/2000
Full
Yes
500/2000
Full
No
500
Standard
Temperature Level/Interface
High
Pressure Level/Interface
High Temp./ Level/Interface
High Press.
1000 psi
(70 bar)
6250 psi
(431 bar)
6250 psi
(431 bar)
Yes
Yes
10000
Full
Yes
10000
Full
Yes
10000
Standard
Temperature
High
Pressure
High Temp./
High Press.
Yes
No
10000
Full
No
10000
Full
No
10000
Yes
No
10000
Full
No
10000
Yes
No
10000
Full
No
10000
Yes
No
1500
No
No
10000
No
No
1500
Level
Level
Level
Standard
7y1 Temperature
Level
7y3
High Temp./
Level
High Press.
Standard
7y4
Temperature Level/Interface
7y6
High Temp./ Level/Interface
High Press
7y7
Standard
Temperature Level/Interface
7y2
Bulk Solids
Probe
7y5
Application
end view
Bulk Solids
Probe
Level
Level
TRANSMITTER
SPECIFICATIONS
FUNCTIONAL/PHYSICAL
System Design
Measurement Principle
Input
Measured Variable
Span
6 inches to 100 feet (15 cm to 30 m); Model 7yS Probe 20 feet (610 cm) max.
Output
Type
Resolution
Analog:
Digital Display:
.003 mA
1 mm
Loop Resistance
Diagnostic Alarm
Selectable: 3.6 mA, 22 mA (meets requirements of NAMUR NE 43), or HOLD last output
Diagnostic Indication
Damping
User Interface
Keypad
Display
Digital Communication/Systems
Menu Languages
Housing
Material
Net/Gross Weight
Overall Dimensions
Cable Entry
TRANSMITTER
SPECIFICATIONS
CONTINUED
FUNCTIONAL/PHYSICAL
Environment
Operating Temperature
-40 to +175 F (-40 to +80 C); LCD viewable -5 to +160 F (-20 to +70 C)
Storage Temperature
Humidity
0 to 99%, non-condensing
Electromagnetic Compatibility
Surge Protection
Shock/Vibration
Performance
Reference Conditions
Linearity
Coaxial/Caged Probes:
Accuracy
Coaxial/Caged Probes:
Interface Operation:
Coaxial/Caged probes: 1 inch (25 mm) for an interface thickness greater than
2 inches (50 mm)
Twin Flexible probes: 2 inch (50 mm) for an interface thickness greater than
8 inches (200 mm)
Resolution
Repeatability
Hysteresis
Response Time
Approximately 1 second
Initialization Time
Approx. 0.02% of probe length/degree C (for probes greater than 8 feet (2.5 m))
Process Dielectric
FOUNDATION fieldbus
ITK Version
6.0.1
H1 Device Class
H1 Profile Class
31PS, 32L
Function Blocks
(8) Al, (3) Transducer, (1) Resource, (1) Arithmetic, (1) Input Selector,
(1) Signal Characterizer, (2) PID, (1) Integrator
Quiescent Current
15 mA
Execution Time
COAXIAL
PROBE
MATRIX
7yT
7yP
Description
Standard Temperature
High Pressure
Application
Level/Interface
Level/Interface
Installation
Tank/Chamber
Tank/Chamber
Overfill Safe
Yes
Yes
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
Teflon TFE
Teflon TFE
Materials Probe
Process Seal
Spacers
Probe Outside Diameter
Enlarged
Basic
Process Connection
Threaded
Flanged
Available Probe Length
Standard 12 to 240 inches (30 to 610 cm) 12 to 240 inches (30 to 610 cm)
Enlarged 50 feet (15 m) max. segmented 50 feet (15 m) max. segmented
Transition Zones
Top
Bottom
0 inches (0 mm)
Process Temperature
1000 psi @ +70 F (70 bar @ +20 C) 6250 psi @ +70F (431 bar @ +20C)
Dielectric Range
Vacuum Service
1.4 to 100
1.4 to 100
Negative Pressure,
but no hermetic seal
Full Vacuum
2000cP (mPa.s)
500cP (mPa.s)
2000cP (mPa.s)
500cP (mPa.s)
Filming
Filming
Viscosity
Enlarged
Basic
Media Coating
10
COAXIAL
PROBE
MATRIX
CONTINUED
7yD
7yS
Description
Steam Probe
Application
Level/Interface
Saturated Steam
Installation
Tank/Chamber
Tank/Chamber
Overfill Safe
Yes
No
Materials Probe
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Process Seal
PEEK HT/Ceramic
PEEK HT/Ceramic
N/A
Spacers
Probe Outside Diameter
Enlarged
Basic
Process Connection
Threaded
Flanged
Process Temperature
Max. Process Pressure
Dielectric Range
1.4 to 100
10 to 100
Vacuum Service
Full Vacuum
Full Vacuum
2000cP (mPa.s)
500cP (mPa.s)
N/A
500cP (mPa.s)
Filming
Filming
Viscosity
Enlarged
Basic
Media Coating
Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100%
measuring range outside of the transition zones.
Refer to chart on page 16.
ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with
glass seal are hermetically sealed to <10-8 cc/sec @ 1 atmosphere helium.
Can be reduced to 3" (75 mm) when lower accuracy is acceptable.
1.2 minimum dielectric when end of probe analysis is enabled.
Consult factory for overfill applications.
11
CAGED
PROBE
MATRIX
7yG
7yL
7yJ
Description
Standard Temperature
High Pressure
Application
Level/Interface
Level/Interface
Level/Interface
Installation
Chamber
Chamber
Chamber
Yes
Yes
Yes
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
PEEK
PEEK
PEEK HT/Celazole
Overfill Safe
Materials Probe
Process Seal
Spacers
Probe Outside Diameter
r = 1.4: 6 inches (150 mm) , r = 1.4: 6 inches (150 mm) , r = 1.4: 6 inches (150 mm) ,
r = 80: 2 inches (50 mm)
r = 80: 2 inches (50 mm)
r = 80: 2 inches (50 mm)
0 inches (0 mm)
0 inches (0 mm)
0 inches (0 mm)
Process Temperature
1000 psi @ +70 F (70 bar @ +20 C) 6250 psi @ +70 F (431 bar @ +20 C) 6250 psi @ +70 F (431 bar @ +20 C)
Dielectric Range
Vacuum Service
Viscosity
Media Coating
1.4 to 100
1.4 to 100
1.4 to 100
Negative Pressure,
but no hermetic seal
Full Vacuum
Full Vacuum
10,000cP (mPa.s)
10,000cP (mPa.s)
10,000cP (mPa.s)
12
SINGLE
ROD
RIGID
PROBE
MATRIX
7yF
7yM
7yN
Description
Standard Temperature
High Pressure
Application
Level
Level
Level
Installation
Tank
Tank
Tank
No
No
No
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
PFA Insulated 316/316L rod
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
316/316L (1.4401/1.4404)
Hastelloy C (2.4819)
Monel (2.4360)
None
None
PEEK HT/Celazole
2 (NPT or BSP)
Various ANSI, EN1092, and
proprietary flanges
Overfill Safe
Materials Probe
Process Seal
Spacers
Probe Outside Diameter
Process Connection
Threaded
Flanged
Top
Bottom
24 to 240 inches (60 to 610 cm) 24 to 240 inches (60 to 610 cm) 24 to 240 inches (60 to 610 cm)
r = 1.4: 6 inches (150 mm) , r = 1.4: 6 inches (150 mm) , r = 1.4: 6 inches (150 mm) ,
r = 80: 2 inches (50 mm)
r = 80: 2 inches (50 mm)
r = 80: 2 inches (50 mm)
Application Dependent
Application Dependent
Application Dependent
Process Temperature
1000 psi @ +70 F (70 bar @ +20 C) 6250 psi @ +70 F (431 bar @ +20 C) 6250 psi @ +70 F (431 bar @ +20 C)
Dielectric Range
Vacuum Service
Viscosity
Media Coating
1.7 to 100
1.7 to 100
1.7 to 100
Negative Pressure,
but no hermetic seal
Full Vacuum
Full Vacuum
10,000cP (mPa.s)
10,000cP (mPa.s)
10,000cP (mPa.s)
13
FLEXIBLE
PROBES
FOR
LIQUIDS
MATRIX
7y1
7y3 (Future)
Description
Single Flexible
Standard Temperature
Single Flexible
HTHP
Application
Level
Level
Installation
Tank
Tank
No
No
316 (1.4401)
316 (1.4401)
Overfill Safe
Materials Cable
Process Seal
Probe Outside Diameter
Process Connection
Threaded
Flanged
Top
Bottom
Process Temperature
1000 psi @ +70 F (70 bar @ +20C) 6250 psi @ +70 F (431 bar @ +20 C)
Dielectric Range
Vacuum Service
Viscosity
Media Coating
1.7 to 100
1.7 to 100
Negative Pressure,
but no hermetic seal
Full Vacuum
10,000 (mPa.s)
10,000 (mPa.s)
14
FLEXIBLE
PROBES
FOR
LIQUIDS
MATRIX
CONTINUED
7y4 (Future)
7y6 (Future)
7y7
Description
Single Flexible
Standard Temperature
Single Flexible
HTHP
Twin Flexible
Standard Temperature
Application
Level
Level
Level/Interface
Installation
Chamber
Chamber
Tank/Chamber
Overfill Safe
No
No
No
316 (1.4401)
316 (1.4401)
Materials Cable
Process Seal
Cable Outside Diameter
Process Connection
Threaded
Flanged
Top
Bottom
Process Temperature
-40 to +400 F (-40 to +200 C) -320 to +850 F (-196 to +450 C) -40 to +400 F (-40 to +200 C)
1000 psi @ +70 F (70 bar @ +20 C) 6250 psi @ +70 F (431 bar @ +20 C) 1000 psi @ +70 F (70 bar @ +20 C)
Dielectric Range
Vacuum Service
Viscosity
Media Coating
1.7 to 100
1.7 to 100
1.7 to 100
Negative Pressure,
but no hermetic seal
Full Vacuum
Negative Pressure,
but no hermetic seal
10,000 (mPa.s)
10,000 (mPa.s)
1500 (mPa.s)
15
FLEXIBLE
PROBES
FOR
SOLIDS
MATRIX
7y2
7y5
Description
Application
Level
Level
Installation
Tank
Tank
Overfill Safe
No
No
Materials Cable
316 (1.4401)
316 (1.4401)
Threaded
2" NPT or 2" BSP
2" NPT or 2" BSP
Flanged Various ANSI, EN1092, and proprietary flanges Various ANSI, EN1092, and proprietary flanges
Available Probe Length
4 to 100
1.9 to 100
10,000 (mPa.s)
10,000 (mPa.s)
Transition Zones
Dielectric Range
Top
Bottom
Vacuum Service
Viscosity
Media Coating
Transition zones (areas with reduced accuracy) are dielectric dependent. It is recommended to set the 0-100% measuring range outside of the transition zones.
1.2 minimum dielectric when end of probe analysis is enabled.
ECLIPSE probes containing o-rings can be used for vacuum (negative pressure) service, but only those probes with glass seal are hermetically sealed
(helium leak <10-8cc/sec @ 1 atmos.).
6500
6500
6000
6000
5500
5000
4500
4000
5500
5000
4500
4000
3500
3500
3000
3000
0
100
200
300
400
500
Temperature (F)
316/316L SST
Hastelloy C276
Monel 400
NOTES:
7yS steam probes are rated to 1275 psi (88 bar) up to +575 F (+300 C)
7y3, 7y6 HTHP flexible probes:
Pressure is limited by the chamber
7y2, 7y5 bulk solids probes: 50 psi (3.45 bar) to +150 F (+65 C)
High pressure probes with threaded fittings are rated as follows:
7yD, 7yN, 7yP and 7y3 probes with threaded fittings have 3600 psi (248 bar) rating .
7yM probes with threaded fittings have 2016 psi (139 bar) rating.
16
200
400
600
Temperature (F)
316/316L SST
Hastelloy C276
Monel 400
800
1000
O-RING
(SEAL)
O-Ring
Material
Max. Process
Temperature
SELECTION
CHART
Code
Viton GFLT
-40 F
(-40 C)
EPDM
-60 F
(-50 C)
Kalrez 4079
-40 F
(-40 C)
1000 psi 70 F
(70 bar @
20C)
-4 F
(-20 C)
NACE applications
HSN
275 F @ 320 psi
(Highly Saturated (135 C @ 22 bar)
Nitrile)
Buna-N
-4 F
(-20 C)
Neoprene
-65 F
(-55 C)
1000 psi 70 F
(70 bar @
20C)
Acetaldehyde, ammonia +
lithium metal solution,
butyraldehyde, di-water,
freon, ethylene oxide,
liquors, isobutyraldehyde
Chemraz 505
-20 F
(-30 C)
1000 psi 70 F
(70 bar @
20C)
Polyurethane
-65 F
(-55 C)
1000 psi 70 F
(70 bar @
20C)
Acids, Ketones,
chlorinated HCs,
-4 F
(-20 C)
1000 psi 70 F
(70 bar @
20C)
Aegis PF128
Kalrez 2035
-40 F
(-40 C)
1000 psi 70 F
(70 bar @
20C)
Kalrez 6375
-40 F
(-40 C)
1000 psi 70 F
(70 bar @
20C)
-320 F
(-195 C)
6250 psi 70 F
(431 bar @
20C)
General high
temperature/high pressure
applications, hydrocarbons,
full vacuum (hermetic),
ammonia, chlorine
Glass Ceramic
D or N
Alloy
17
REPLACEMENT
OF
DISPLACER
TRANSMITTERS
Ease of replacement:
Proprietary and standard ANSI flanges are offered on all
ECLIPSE Model 706 probes so existing chamber/cages
can be used.
Type of application:
Use the proper GWR probe for the application, see
pages 7 and 10 through 16.
Cost:
The cost of a new Model 706 transmitter cost is comparable to rebuilding an aging torque tube.
Overfill proof:
For optimum performance, use an Overfill-safe probe
in all chamber applications.
Installation:
No field calibration is necessary. The Model 706 transmitter can be configured in minutes with no level movement. (Complete factory pre-configuration is available,
which can further decrease the installation effort).
Performance:
The ECLIPSE Model 706 is unaffected by changes in
specific gravity and has no moving parts that can wear
and lose tolerance.
Body connection
E
20 mA / 100 %
P
Measuring range:
min 12 (30 cm)
max 224" (570)
H
Displacer
Length
After
4 mA / 0 %
F
Type
Process Connection
MAGNETROL
EZ & PN Modulevel
Masoneilan
Series 1200
Fisher series
2300 & 2500
Eckardt
Tokyo Keiso
FST-3000
ANSI/EN flange
Proprietary flange
ANSI/EN flange
Proprietary flange
ANSI flange
ANSI/EN flange
ANSI/EN flange
ANSI/EN flange
18
Displacer Length
inches (mm)
14" (356)
14" (356)
16" (406)
14" (356)
14" (356)
14" (356)
H = 11.8" (300)
H = 19.7" (500)
Probe Length
inches (mm)
Displacer + 7 (178)
Displacer + 8 (203)
Displacer + 8 (203)
Displacer + 10 (254)
consult factory
consult factory
Displacer + 9 (229)
Displacer + 9 (229)
PROPRIETARY
INCHES
FLANGES
(mm)
9.00
(229)
5.62
(143)
7.25
(184)
7.50
(191)
4.75
(121)
45
45
45
0.43
(11)
0.87
(22)
0.87
(22)
1.25
(32)
5.23
(133)
1.12
(29)
3.37
(86)
0.22
(6)
MAGNETROL
5.875
(149)
1.25
(32)
4.00
(102)
.188
(5)
0.25
(6)
CHAMBERS
A brief description of the MAGNETROL chamber offering follows. For more details, refer to
MAGNETROL Sales Bulletin 41-140.
MAGNETROL has a long tradition in offering cost-effective chambers. The MAGNETROL external
chamber is a self-contained cage designed for use with our top mounting level transmitters or
switches. Quality construction and a wide selection of configurations make this cage an ideal means
of utilizing the power of Guided Wave Radar without mounting directly into the process vessel.
F21-4A2D-014
PED
Some Model 706 probes can be installed into chambers
as small as 2". When a new chamber is required, it can be
Measuring
Range
Measuring
Range
Sealed Chamber
Measuring
Range
PACTware
PC
SOFTWARE
20
AGENCY
APPROVALS
AGENCY
MODEL APPROVED
APPROVAL CATEGORY
APPROVAL CLASSES
FM
706-51XX-1XX
Intrinsically Safe
706-51XX-3XX
Explosion-proof
(with Intrinsically Safe probe)
Dust Ignition-proof
CSA
ATEX
IEC
706-51XX-XXX
706-51XX-1XX
Intrinsically Safe
706-51XX-3XX
Explosion-proof
(with Intrinsically Safe probe)
Dust Ignition-proof
706-51XX-XXX
Non-Incendive
Suitable for:
706-51XX-AXX
Intrinsically Safe
706-51XX-CXX
Non-sparking
706-51XX-DXX
Dust Ex
706-51XX-BXX
Flame Proof
706-5XXX-AXX
Intrinsically Safe
Ex ia IIC T4 Ga
706-5XXX-CXX
Non-sparking
706-5XXX-BXX
Flame Proof
21
MODEL
NUMBER
TRANSMITTER
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
4 | POWER
5
24 VDC, Two-Wire
5 | SIGNAL OUTPUT
1
4 20 mA with HART
6 | SAFETY OPTIONS
0
7 | ACCESSORIES/MOUNTING
0
8 | CLASSIFICATION
0
9 | HOUSING
1
10 | CONDUIT CONNECTION
22
M20
10
2" NPT
DIMENSIONS
inches
3.38
(86)
(mm)
4.18
(106)
3.77
(96)
8.34
(212)
4.18
(106)
3.38
(86)
9.30
(236)
5.09
(129)
3.77
(96)
2 cable
entries
4.03
(102)
45
Integral Electronics
Eclipse Housing
(45 View)
2 cable
entries
2.37
(60)
45
3.00
(76)
2.00
(51)
3.50
(89)
33 or 144
(838 or 3650)
3.75
(95)
2 Holes
.38 (10) Dia.
4.15
(105)
ELECTRICAL
WIRING
Power supply:
GP / intrinsically safe / explosion-proof: min 11 VDC
HART modem
0% 100%
Galvanic Barrier:
max: 28.4 VDC @ 94 mA for intrinsically safe units
max: 17.5 VDC @ 380mA for FOUNDATION fieldbus units
(not needed for GP, Dust Ex, and explosion-proof models).
250 minimum required for HART Communications
Ex
Non Ex
23
MODEL
NUMBER
ENLARGED
COAXIAL
PROBE
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
1 | TECHNOLOGY
7
2 | MEASUREMENT SYSTEM
A
English
Metric
3 | CONFIGURATION/STYLE (RIGID)
D
Enlarged Coaxial, High Temp/High Pressure: Overfill w/Glass Seal (+850 F/+450 C) Available only with 10th digit N or D
Enlarged Coaxial, High Pressure: Overfill w/Glass Seal (+400 F/+200 C) Available only with 10th digit N or D
Enlarged Coaxial, Overfill Standard O-Ring Seal (+400 F/+200 C) Not available with 10th digit N or D
2"
44
2"
45
2"
4K
53
150# ANSI RF
5M
3"
600# ANSI RF
5N
3"
63
4"
150# ANSI RF
2"
64
4"
300# ANSI RF
3"
150# ANSI RF
65
4"
600# ANSI RF
54
3"
300# ANSI RF
66
4"
900# ANSI RF
55
3"
600# ANSI RF
67
4"
1500# ANSI RF
56
3"
900# ANSI RF
68
4"
2500# ANSI RF
57
3"
1500# ANSI RF
6K
4"
58
3"
2500# ANSI RF
6L
4"
5K
3"
6M
4"
5L
3"
6N
4"
300# ANSI RF
EN Flanges
DN 50, PN 16
EN 1092-1 TYPE A
DN 80, PN 320
EN 1092-1 TYPE B2
DB
EH
DN 80, PN 400
EN 1092-1 TYPE B2
DN 50, PN 63
EN 1092-1 TYPE B2
EJ
DD
FA
DN 100, PN 16
EN 1092-1 TYPE A
DE
DN 50, PN 100
DN 100, PN 25/40
EN 1092-1 TYPE A
EA
DN 80, PN 16
EN 1092-1 TYPE A
FB
FD
DN 100, PN 63
EN 1092-1 TYPE B2
EB
DN 80, PN 25/40
EN 1092-1 TYPE A
FE
DN 100, PN 100
EN 1092-1 TYPE B2
ED
DN 80, PN 63
EN 1092-1 TYPE B2
FF
DN 100, PN 160
EN 1092-1 TYPE B2
EE
DN 80, PN 100
EN 1092-1 TYPE B2
FG
DN 100, PN 250
EN 1092-1 TYPE B2
EF
DN 80, PN 160
EN 1092-1 TYPE B2
FH
DN 100, PN 320
EN 1092-1 TYPE B2
EG
DN 80, PN 250
EN 1092-1 TYPE B2
FJ
DN 100, PN 400
EN 1092-1 TYPE B2
TT
TU
UT
UU
DA
EN 1092-1 TYPE B2
7
1
24
10
11
12
13
14
15
MODEL
NUMBER
ENLARGED
CONTINUED
COAXIAL
PROBE
6 | CONSTRUCTION CODES
0
K
L
M
N
Industrial
ASME B31.1
ASME B31.3
ASME B31.3 & NACE MR0175/MR0103
NACE MR0175/MR0103
7 | FLANGE OPTIONS Offset flanges are only available with small coaxial probes
0
None
9 | SPACER MATERIAL
1
2
3
4
5
13 14 15 | INSERTION LENGTH
inches (012 396)
cm (030 999)
XXX
7
1
10
11
12
13
14
15
25
MODEL
SMALL
NUMBER
COAXIAL
PROBE
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
1 | TECHNOLOGY
7
2 | MEASUREMENT SYSTEM
A
C
English
Metric
3 | CONFIGURATION/STYLE (RIGID)
D
P
S
T
Small Coaxial, High Temp/High Pressure: Overfill w/Glass Seal (+850 F/+450 C) Available only with 10th digit N or D
Small Coaxial, High Pressure: Overfill w/Glass Seal (+400 F/+200 C) Available only with 10th digit N or D
Small Coaxial, Saturated Steam (+575 F/+300 C), Max. Length=240 (610 cm) Available only with 10th digit N, 11th digit 2
Small Coaxial, Overfill Standard O-Ring Seal (+400 F/+200 C) Not available with 10th digit N or D
150# ANSI RF
300# ANSI RF
600# ANSI RF
600# ANSI RTJ
150# ANSI RF
300# ANSI RF
600# ANSI RF
600# ANSI RTJ
900/1500# ANSI RF
900/1500# ANSI RTJ
1"
1"
1"
1"
1 12"
1 12"
1 12"
1 12"
1 12"
1 12"
38
3N
43
44
45
47
48
4K
4M
4N
1 12"
1 12"
2"
2"
2"
2"
2"
2"
2"
2"
2500# ANSI RF
53
2500# ANSI RTJ
54
150# ANSI RF
55
300# ANSI RF
56
600# ANSI RF
57
900/1500# ANSI RF 5 8
2500# ANSI RF
5K
600# ANSI RTJ
5L
900/1500# ANSI RTJ 5 M
2500# ANSI RTJ
5N
3"
3"
3"
3"
3"
3"
3"
3"
3"
3"
150# ANSI RF
300# ANSI RF
600# ANSI RF
900# ANSI RF
1500# ANSI RF
2500# ANSI RF
600# ANSI RTJ
900# ANSI RTJ
1500# ANSI RTJ
2500# ANSI RTJ
4"
4"
4"
4"
4"
4"
4"
4"
4"
4"
63
64
65
66
67
68
6K
6L
6M
6N
150# ANSI RF
300# ANSI RF
600# ANSI RF
900# ANSI RF
1500# ANSI RF
2500# ANSI RF
600# ANSI RTJ
900# ANSI RTJ
1500# ANSI RTJ
2500# ANSI RTJ
EN Flanges
BB
BC
BF
CB
CC
CF
CG
CH
CJ
DA
DB
DD
DE
DF
DG
DH
DN
DN
DN
DN
DN
DN
DN
DN
DN
25,
25,
25,
40,
40,
40,
40,
40,
40,
PN
PN
PN
PN
PN
PN
PN
PN
PN
16/25/40 EN
63/100 EN
160
EN
16/25/40 EN
63/100 EN
160
EN
250
EN
320
EN
400
EN
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
DN
DN
DN
DN
50,
50,
50,
50,
PN
PN
PN
PN
16
25/40
63
100
1092-1
1092-1
1092-1
1092-1
TYPE
TYPE
TYPE
TYPE
DN 50, PN 160
DN 50, PN 250
DN 50, PN 320
EN
EN
EN
EN
DJ
EA
EB
ED
EE
EF
EG
EH
E J
FA
FB
FD
FE
FF
FG
FH
FJ
A
B2
B2
A
B2
B2
B2
B2
B2
A
A
B2
B2
EN 1092-1 TYPE B2
EN 1092-1 TYPE B2
EN 1092-1 TYPE B2
600#
600#
600#
600#
DN 50, PN 400
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
EN 1092-1 TYPE B2
80, PN 16
EN 1092-1 TYPE A
80, PN 25/40
EN 1092-1 TYPE A
80, PN 63
EN 1092-1 TYPE B2
80, PN 100
EN 1092-1 TYPE B2
80, PN 160
EN 1092-1 TYPE B2
80, PN 250
EN 1092-1 TYPE B2
80, PN 320
EN 1092-1 TYPE B2
80, PN 400
EN 1092-1 TYPE B2
100, PN 16
EN 1092-1 TYPE A
100, PN 25/40
EN 1092-1 TYPE A
100, PN 63
EN 1092-1 TYPE B2
100, PN 100
EN 1092-1 TYPE B2
100, PN 160
EN 1092-1 TYPE B2
100, PN 250
EN 1092-1 TYPE B2
100, PN 320
EN 1092-1 TYPE B2
100, PN 400
EN 1092-1 TYPE B2
7
1
26
10
11
12
13
14
15
MODEL
SMALL
NUMBER
COAXIAL
CONTINUED
PROBE
6 | CONSTRUCTION CODES
0
K
L
M
N
Industrial
ASME B31.1
ASME B31.3
ASME B31.3 & NACE MR0175/MR0103
NACE MR0175/MR0103
7 | FLANGE OPTIONS Offset flanges are only available with small coaxial probes
0
1
2
3
None
Offset (For use with AURORA) 3 Available only with 3rd digit P, S or T
Offset with 12" NPT (For use with AURORA) 3 Available only with 3rd digit P, S or T
Offset with 34" NPT (For use with AURORA) 3 Available only with 3rd digit P, S or T
316 SS/316L SS
Hastelloy C
Monel Not available with 3rd Digit S
316 SS/316L SS with Carbon Steel Flange
Hastelloy C with Carbon Steel Flange
Monel with Carbon Steel Flange Not available with 3rd Digit S
9 | SPACER MATERIAL
1
2
3
5
12 | SPECIAL OPTIONS
0
13 14 15 | INSERTION LENGTH
inches (012 240)
cm (030 610)
XXX
7
1
2
2
10
11
12
13
14
15
27
MODEL
CAGED
NUMBER
PROBE
1 | TECHNOLOGY
7
2 | MEASUREMENT SYSTEM
A
English
Metric
3 | CONFIGURATION/STYLE (RIGID)
G
Overfill Caged Rigid Probe for use in chambers +400 F (+200 C) (Available only with 2", 3", and 4" flanges)
Overfill Caged High Temp/High Pressure Probe with Glass Seal for use in chambers +850 F (+450 C)
(Available only with 2", 3", and 4" flanges)
Overfill Caged High Pressure Probe with Glass Seal for use in chambers +400 F (+200 C)
(Available only with 2", 3", and 4" flanges)
2"
150# ANSI RF
54
3"
300# ANSI RF
63
4"
150# ANSI RF
44
2"
300# ANSI RF
55
3"
600# ANSI RF
64
4"
300# ANSI RF
45
2"
600# ANSI RF
56
3"
900# ANSI RF
65
4"
600# ANSI RF
47
2"
900/1500# ANSI RF
57
3"
1500# ANSI RF
66
4"
900# ANSI RF
48
2"
2500# ANSI RF
58
3"
2500# ANSI RF
67
4"
1500# ANSI RF
4K
2"
5K
3"
68
4"
2500# ANSI RF
4M
2"
5L
3"
6K
4"
4N
2"
5M
3"
6L
4"
53
3"
150# ANSI RF
5N
3"
6M
4"
6N
4"
EN Flanges
DA
DN 50, PN 16
EN 1092-1 TYPE A
EE
DN 80, PN 100
EN 1092-1 TYPE B2
DB
FA
DN 100, PN 16
EN 1092-1 TYPE A
DD
DN 50, PN 63
EN 1092-1 TYPE B2
FB
DN 100, PN 25/40
EN 1092-1 TYPE A
DE
DN 50, PN 100
EN 1092-1 TYPE B2
FD
DN 100, PN 63
EN 1092-1 TYPE B2
EA
DN 80, PN 16
EN 1092-1 TYPE A
FE
DN 100, PN 100
EN 1092-1 TYPE B2
EB
DN 80, PN 25/40
EN 1092-1 TYPE A
FF
DN 100, PN 160
EN 1092-1 TYPE B2
ED
DN 80, PN 63
EN 1092-1 TYPE B2
FG
DN 100, PN 250
EN 1092-1 TYPE B2
TU
UT
UU
7
1
28
10
11
12
13
14
15
MODEL
CAGED
NUMBER
CONTINUED
PROBE
6 | CONSTRUCTION CODES
0
Industrial
ASME B31.1
ASME B31.3
NACE MR0175/MR0103
7 | FLANGE OPTIONS
0
None
Offset with 12 (For use with AURORA) Available only with 3rd digit G and 4th digit 6
Offset (For use with AURORA) Available only with 3rd digit G and 4th digit 6
Offset (For use with AURORA) Available only with 3rd digit G and 4th digit 6
316 SS/316L SS
Hastelloy C
Monel
9 | SPACER MATERIAL
2
D
N
None
13 14 15 | INSERTION LENGTH
inches (012 288)
cm (030 732)
XXX
7
1
0
2
10
11
12
13
14
15
29
MODEL
SINGLE
NUMBER
ROD
RIGID
PROBE
1 | TECHNOLOGY
7
2 | MEASUREMENT SYSTEM
A
C
English
Metric
3 | CONFIGURATION/STYLE (RIGID)
F
M
N
22
42
ANSI Flanges
2
2
2
3
3
3
4
4
4
4
4
3
4
5
3
4
5
3
4
5
7
8
4K
4M
4N
53
54
55
56
57
58
5K
5L
2"
2"
2"
3"
3"
3"
3"
3"
3"
3"
3"
5M
5N
63
64
65
66
67
68
6K
6L
6M
6N
3"
3"
4"
4"
4"
4"
4"
4"
4"
4"
4"
4"
EN Flanges
BB
BC
BF
CB
CC
CF
CG
CH
CJ
DA
DB
DD
DE
DF
DG
DH
DN
DN
DN
DN
DN
DN
DN
DN
DN
25,
25,
25,
40,
40,
40,
40,
40,
40,
PN
PN
PN
PN
PN
PN
PN
PN
PN
16/25/40 EN
63/100 EN
160
EN
16/25/40 EN
63/100 EN
160
EN
250
EN
320
EN
400
EN
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
1092-1
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
TYPE
DN
DN
DN
DN
50,
50,
50,
50,
PN
PN
PN
PN
16
25/40
63
100
1092-1
1092-1
1092-1
1092-1
TYPE
TYPE
TYPE
TYPE
DN 50, PN 160
DN 50, PN 250
DN 50, PN 320
EN
EN
EN
EN
A
B2
B2
A
B2
B2
B2
B2
B2
A
A
B2
B2
EN 1092-1 TYPE B2
EN 1092-1 TYPE B2
EN 1092-1 TYPE B2
DJ
EA
EB
ED
EE
EF
EG
EH
E J
FA
FB
FD
FE
FF
FG
FH
FJ
DN 50, PN 400
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
EN 1092-1 TYPE B2
80, PN 16
EN 1092-1 TYPE A
80, PN 25/40
EN 1092-1 TYPE A
80, PN 63
EN 1092-1 TYPE B2
80, PN 100
EN 1092-1 TYPE B2
80, PN 160
EN 1092-1 TYPE B2
80, PN 250
EN 1092-1 TYPE B2
80, PN 320
EN 1092-1 TYPE B2
80, PN 400
EN 1092-1 TYPE B2
100, PN 16
EN 1092-1 TYPE A
100, PN 25/40
EN 1092-1 TYPE A
100, PN 63
EN 1092-1 TYPE B2
100, PN 100
EN 1092-1 TYPE B2
100, PN 160
EN 1092-1 TYPE B2
100, PN 250
EN 1092-1 TYPE B2
100, PN 320
EN 1092-1 TYPE B2
100, PN 400
EN 1092-1 TYPE B2
7
1
30
10
11
12
13
14
15
MODEL
SINGLE
NUMBER
ROD
RIGID
CONTINUED
PROBE
6 | CONSTRUCTION CODES
0
Industrial
ASME B31.1
ASME B31.3
NACE MR0175/MR0103
7 | FLANGE OPTIONS
0
None
316 SS/316L SS
Hastelloy C
Monel
Faced Flange, PFA coated wetted surfaces Available only with Digit 3rd digit F
9 | SPACER MATERIAL
0
None
12 | SPECIAL OPTIONS
0
13 14 15 | INSERTION LENGTH
inches (012 288)
cm (030 732)
XXX
7
1
0
2
0
8
10
11
12
13
14
15
31
MODEL
SINGLE
NUMBER
FLEXIBLE
PROBE
1 | TECHNOLOGY
7
2 | MEASUREMENT SYSTEM
A
English
Metric
Single Cable Flexible HTHP for in-tank applications (+850 F/+450 C) (Future)
Single Cable Flexible standard for chamber applications (+400 F/+200 C) (Future)
Single Cable Flexible HTHP for chamber applications (+850 F/+450 C) (Future)
42
ANSI Flanges
43
2"
150# ANSI RF
44
2"
300# ANSI RF
45
2"
600# ANSI RF
53
3"
150# ANSI RF
54
3"
300# ANSI RF
55
3"
600# ANSI RF
63
4"
150# ANSI RF
64
4"
300# ANSI RF
65
4"
600# ANSI RF
EN Flanges
DA
DN 50, PN 16
EN 1092-1 TYPE A
DB
DN 50, PN 25/40
EN 1092-1 TYPE A
DD
DN 50, PN 63
EN 1092-1 TYPE B2
DE
DN 50, PN 100
EN 1092-1 TYPE B2
EA
DN 80, PN 16
EN 1092-1 TYPE A
EB
DN 80, PN 25/40
EN 1092-1 TYPE A
ED
DN 80, PN 63
EN 1092-1 TYPE B2
EE
DN 80, PN 100
EN 1092-1 TYPE B2
FA
DN 100, PN 16
EN 1092-1 TYPE A
FB
DN 100, PN 25/40
EN 1092-1 TYPE A
FD
DN 100, PN 63
EN 1092-1 TYPE B2
FE
DN 100, PN 100
EN 1092-1 TYPE B2
7
1
32
10
11
12
13
14
15
MODEL
SINGLE
NUMBER
FLEXIBLE
CONTINUED
PROBE
6 | CONSTRUCTION CODES
0
Industrial
7 | FLANGE OPTIONS
0
None
316 SS/316L SS
9 | SPACER MATERIAL
0
None
Viton GFLT
Kalrez 4079
Kalrez 6375
12 | SPECIAL OPTIONS
0
13 14 15 | INSERTION LENGTH
feet (003 100)
meters (001 030)
XXX
7
1
0
8
3
10
11
12
13
14
15
33
MODEL
TWIN
NUMBER
FLEXIBLE
PROBE
1 | TECHNOLOGY
7
2 | MEASUREMENT SYSTEM
A
English
Metric
3"
54
3"
55
3"
63
4"
64
4"
65
4"
EN Flanges
EA
DN 80, PN 16
EN 1092-1 TYPE A
EB
DN 80, PN 25/40
EN 1092-1 TYPE A
ED
DN 80, PN 63
EN 1092-1 TYPE B2
EE
DN 80, PN 100
EN 1092-1 TYPE B2
FA
DN 100, PN 16
EN 1092-1 TYPE A
FB
DN 100, PN 25/40
EN 1092-1 TYPE A
FD
DN 100, PN 63
EN 1092-1 TYPE B2
FE
DN 100, PN 100
EN 1092-1 TYPE B2
7
1
34
10
11
12
13
14
15
MODEL
TWIN
NUMBER
FLEXIBLE
CONTINUED
PROBE
6 | CONSTRUCTION CODES
0
Industrial
7 | FLANGE OPTIONS
0
None
316 SS/316L SS
9 | SPACER MATERIAL
0
None
Viton GFLT
Kalrez 4079
Kalrez 6375
12 | SPECIAL OPTIONS
0
None
13 14 15 | INSERTION LENGTH
feet (003 100)
meters (001 030)
XXX
7
1
0
8
10
11
12
13
14
15
35
SEGMENTED
PROBE
12th
MODEL
DIGIT
OF
OPTIONS
NUMBER
Probe Model
One Segment
Two Segments
Three Segments
Four Segments
Coaxial Models
7yD, 7yP and 7yT
(Enlarged versions only)
(3 Process Connections
and larger)
12 240"
(30 610 cm)
48 240"
(120 610 cm)
72 360"
(180 914 cm)
96 396"
(240 990 cm)
Caged Models
7yG, 7yL and 7yJ
12 120"
(30 305 cm)
24 240"
(60 610 cm)
36 288"
(90 732 cm)
48 288"
(120 732 cm)
NOTE: Segments will be evenly divided over the length of the probe.
36
COAXIAL
INCHES
3.38
(86)
PROBE
DIMENSIONS
(mm)
4.18
(106)
3.77
(96)
3.77
(96)
3.77
(96)
9.30
(236)
45
2 cable
entries
4.18
(106)
3.38
(86)
4.18
(106)
3.38
(86)
9.30
(236)
9.30
(236)
45
2 cable
entries
45
2 cable
entries
4.46
(113)
7.76
(197)
Mounting
Flange
10.45
(265)
Mounting
Flange
Probe
Insertion
Length
Model 7yT
with flanged connection
3.38
(86)
Probe
Insertion
Length
Model 7yP
with flanged connection
Probe
Insertion
Length
Model 7yD
with flanged connection
4.18
(106)
3.77
(96)
C
A
E
9.30
(236)
2 cable
entries
45
Inches (mm)
11.55
(293)
Mounting
Flange
Dim.
Small Diameter
Enlarged (standard)
0.88 (22.5)
B
C
D
E
0.31 (8)
4.08 (100)
0.15 (4)
3.78 (96)
0.63 (16)
6.05 (153)
0.30 (8)
5.45 (138)
Probe
Insertion
Length
Model 7yS
with flanged connection
37
CAGED
INCHES
3.38
(86)
PROBE
DIMENSIONS
(mm)
3.38
(86)
3.38
(86)
4.18
(106)
4.18
(106)
3.77
(96)
3.77
(96)
3.77
(96)
9.30
(236)
9.30
(236)
9.30
(236)
45
Mounting
Flange
D
Mounting
Flange
D
Probe
Insertion
Length
Probe
Insertion
Length
L
Model 7yG
with flanged connection
10.45
(265)
6.39
(162)
4.70
(119)
Mounting
Flange
45
2 cable
entries
2 cable
entries
45
2 cable
entries
38
4.18
(106)
Model 7yL
with flanged connection
D
L
Probe
Insertion
Length
Model 7yJ
with flanged connection
Cage Size
2"
3"
4"
SINGLE
INCHES
3.38
(86)
ROD
RIGID
PROBE
DIMENSIONS
(mm)
3.38
(86)
3.38
(86)
4.18
(106)
4.18
(106)
4.18
(106)
3.77
(96)
3.77
(96)
3.77
(96)
9.30
(236)
9.30
(236)
9.30
(236)
45
2 cable
entries
2 cable
entries
45
2 cable
entries
45
4.53
(115)
Mounting
Flange
Mounting
Flange
.38
Probe
Insertion
Length
(9.6)
10.45
(265)
8.38
(213)
Mounting
Flange
.38
(9.6)
Probe
Insertion
Length
.50
(13)
1.33
(34 mm)
Model 7yF
with flanged connection
Model 7yM
with flanged connection
Probe
Insertion
Length
Model 7yN
with flanged connection
39
SINGLE
INCHES
3.38
(86)
FLEXIBLE
PROBE
(mm)
DIMENSIONS
3.38
(86)
4.18
(106)
3.38
(86)
4.18
(106)
4.18
(106)
3.77
(96)
3.77
(96)
3.77
(96)
9.30
(236)
9.30
(236)
9.30
(236)
45
2 cable
entries
2 cable
entries
45
45
2 cable
entries
4.53
(115)
10.45
(265)
Mounting
Flange
10.45
(265)
Mounting
Flange
Probe
Insertion
Length
2.0 (51)
0.19 (0.5)
2.0 (51)
2.0 (51)
3.88
(99)
Probe
Insertion
Length
Model 7y3
with flanged
connection
0.75 (19)
Model 7y1
with flanged connection
3.38
(86)
Mounting
Flange
3.38
(86)
4.18
(106)
4.18
(106)
9.30
(236)
9.30
(236)
6
(152)
2 cable
entries
45
2 cable
entries
2
(51)
45
5.46
(139)
4.70
(119)
Mounting
Flange
Mounting
Flange
2.0 (51)
2.0 (51)
40
6.0
(152)
3.77
(96)
3.77
(96)
Model 7y4
with flanged
connection
Model 7y6
with flanged
connection
6.0
(152)
Probe
Insertion
Length
Probe
Insertion
Length
6.0
(152)
Model 7y2
with flanged
connection
Probe
Insertion
Length
6.0
(152)
IN
TANK
MOUNTING
STANDARD
SINGLE
ROD
PROBE
CONSIDERATIONS
Acceptable objects
Correct Installation
Pipe reducers
should not be used
TWIN
FLEXIBLE
INCHES
PROBE
(mm)
DIMENSIONS
3.38
(86)
4.18
(106)
3.38
(86)
4.18
(106)
3.77
(96)
3.77
(96)
9.30
(236)
6.00
(152)
9.30
(236)
2.00
(51)
2 cable
entries
45
2 cable
entries
45
5.31
(135)
Mounting
Flange
4.54
(115)
Mounting
Flange
Probe
Insertion
Length
0.875 (22.2)
Probe
Insertion
Length
IN
TANK
MOUNTING
TWIN
Model 7y5
with flanged connection
FLEXIBLE
PROBE
CONSIDERATIONS
42
Model 7y7
with flanged connection
AURORA
CHAMBER
The Orion Instruments Aurora is the patented combination of the ECLIPSE Guided Wave Radar transmitter and
a Magnetic Level Indicator (MLI). The integration of these
two independent technologies provides excellent redundancy. A custom float positioned within the AURORA
chamber travels up and down following level changes.
The float contains an internal group of magnets that are
coupled with magnets in the flags of the visual indicator mounted on the outside of the chamber. As the float
moves, the flags rotate to expose the color of their opposite side. The position where the flags color changes corresponds to a point on the measuring scale indicating true
level. In addition to this external visual indicator operated by the AURORA internal float, the ECLIPSE Model 706
transmitter reflects electromagnetic radar pulses directly
off the liquid surface providing a real-time continuous
level output.
Visual
Indication
Range
Center
to
Center
Visual
Indication
Range
Center
to
Center
Visual
Indication
Range
Center
to
Center
43
QUALITY
The quality assurance system in place at
MAGNETROL guarantees the highest level
of quality throughout the company.
MAGNETROL is committed to providing full
customer satisfaction both in quality products
and quality service.
ESP
Expedite
Ship
Plan
WARRANTY
MAGNETROL shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the
installation or use of equipment. There are
no other warranties expressed or implied,
except special written warranties covering
some MAGNETROL products.
5300 Belmont Road Downers Grove, Illinois 60515-4499 630-969-4000 Fax 630-969-9489 www.magnetrol.com
145 Jardin Drive, Units 1 & 2 Concord, Ontario Canada L4K 1X7 905-738-9600 Fax 905-738-1306
Heikensstraat 6 B 9240 Zele, Belgium 052 45.11.11 Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. Burgess Hill, Sussex RH15 9TL U.K. 01444-871313 Fax 01444-871317
Copyright 2013 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol & Magnetrol logotype, Orion Instruments & Orion Instruments logotype, ECLIPSE and MODULEVEL are
registered trademarks of Magnetrol International, Incorporated.
CSA logotype is a registered trademark of Canadian Standards Association.
Eckardt is a registered trademark of Invensys Process Systems.
Fisher is a registered trademark of Emerson Process Management.
FOUNDATION fieldbus logo is a registered trademark of the Fieldbus Foundation.
HART is a registered trademark of the HART Communication Foundation.
Hastelloy is a registered trademark of Haynes International, Inc.
Masoneilan is a registered trademark of Dresser Industries, Inc.
Monel is a registered trademark of International Nickel Co.
PACTware is trademark of PACTware Consortium.
Teflon is a registered trademark of DuPont.
Tokyo Keiso is a registered trademark of Tokyo Keiso Co., Ltd.
Viton and Kalrez are registered trademarks of DuPont Performance Elastomers.
BULLETIN: 57-106.3
EFFECTIVE: May 2013
SUPERCEDES: March 2013