Operating and Parts Manual: Industrial Electric Air Compressors Models 30DG, 40DG, AND 50DG With A Tefc Motor
Operating and Parts Manual: Industrial Electric Air Compressors Models 30DG, 40DG, AND 50DG With A Tefc Motor
_____________________________________SULLIVAN-PALATEK
TABLE OF CONTENTS
SECTION 1 - SAFETY ............................................................................................................. 4
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
GENERAL .................................................................................................................. 4
PRESSURE RELEASE .............................................................................................. 4
FIRES / EXPLOSIONS............................................................................................... 5
MOVING PARTS........................................................................................................ 5
PHYSICAL DANGERS............................................................................................... 6
TOXICITY .................................................................................................................. 6
ELECTRIC SHOCK.................................................................................................... 6
LIFTING ..................................................................................................................... 7
AUTOMATIC START ................................................................................................. 7
NOISE ........................................................................................................................ 7
HAZARD WARNING SIGNS ...................................................................................... 8
LUBRICATION GUIDE............................................................................................... 9
APPLICATION GUIDE ............................................................................................... 9
INTRODUCTION ..................................................................................................... 10
COMPRESSOR UNIT .............................................................................................. 10
MOTOR.................................................................................................................... 10
INTAKE/CONTROL SYSTEM .................................................................................. 12
COMPRESSOR LUBRICATION/COOLING SYSTEM ............................................. 13
COMPRESSOR DISCHARGE SYSTEM ................................................................. 14
STARTER AND ELECTRICAL PARTS .................................................................... 16
INSTRUMENTATION .............................................................................................. 16
RECEIVING ............................................................................................................. 17
WELDING ................................................................................................................ 17
LOCATION............................................................................................................... 17
SUPPORT................................................................................................................ 17
ELECTRICAL CONNECTIONS ............................................................................... 17
MAINTENANCE INDICATION-DIFFERENTIAL INDICATION ................................. 18
DIRECTION OF ROTATION .................................................................................... 18
COMPRESSED AIR PIPING .................................................................................... 18
ADDITIONAL HELP ................................................................................................. 18
SULLIVAN-PALATEK_____________________________________
SECTION 5 - OPERATION .................................................................................................... 19
5.1
5.2
5.3
5.4
5.5
INTRODUCTION ..................................................................................................... 19
INITIAL START ........................................................................................................ 19
NORMAL OPERATION ............................................................................................ 19
SHUTDOWN ............................................................................................................ 19
RESTARTS .............................................................................................................. 20
SCHEDULE ............................................................................................................. 21
OIL FILTER .............................................................................................................. 22
AIR FILTER .............................................................................................................. 22
AIR/OIL SEPARATOR ............................................................................................. 22
BOLT TORQUE SPECS .......................................................................................... 22
PRESSURE ADJUSTMENT .................................................................................... 23
TROUBLESHOOTING ............................................................................................. 24
_____________________________________SULLIVAN-PALATEK
SECTION 1 - SAFETY
1.1
GENERAL
SULLIVAN-PALATEK designs all its compressors so they can be operated safely despite the
fact that operating a motor driven air compressor is inherently hazardous. Responsibility for
continued safe operation rests with those who install, use and maintain the equipment. The
precautions offered in this section will minimize the inherent hazards and reduce the
likelihood of accidental damage and injuries.
The operation of air compressors should be limited to personnel who have been so trained
and specifically assigned to do so, and who have read and understand this operators
manual. Failure to follow the instructions and safety precautions in this manual may increase
the possibility of accidents or injuries. Never start this compressor unless it is safe to do so.
Do not attempt to operate the air compressor with an unsafe condition relative to the
compressor, the electrical system, the air piping, filtering, regulating, preparation,
conditioning, valving, hosing or components. Open the main disconnect switch or circuit
breaker, then lock it out and tag it to prevent anyone else from starting the compressor until
the unsafe condition has been corrected. Operate compressors only in full compliance with
all applicable Federal, State and Local codes and requirements such as OSHA, NEC, NFPA,
CSA, etc. Do not modify this compressor without specific written approval from the factory.
1.2
PRESSURE RELEASE
Open the pressure relief valve(s) periodically to be sure there is no blockage, obstruction, or
inability to operate.
Shut machine off, open and lock-out disconnect switch and vent all pressure before opening
or removing any filter element, line, tube, fitting, valve, plug, cover, connection or any other
component on the air compressor or in the plants compressed air system. Remove oil filler
cap only when compressor has been turned off, the disconnect switch locked open, and
there is no pressure in the oil separation tank. Bleed off any residual pressure by opening
the pressure relief valve. REMEMBER, compressors may re-start AUTOMATICALLY if not
properly taken off the power line!
Do not use accessories such as tools, valves, filters, hoses, piping, dryers, etc. that are rated
lower than the maximum pressure or temperature rating of this compressor. Do not exceed
the accessory component manufacturers rated safe, continuous working pressure or
temperature.
Install appropriate velocity-limiting valves (rated by pipe size and CFM) whenever air hose
larger than inch (102.5 mm) inside diameter is used anywhere in the system to reduce
pressure in case of hose or connection failure. Install additional velocity limiting valves, in
series, whenever 75 feet (22.8 m) of hose length is exceeded. These valves must comply
with pertinent OSHA requirements.
Do not use air pressure greater than 30 PSI (207 kPa) for blow-off or cleaning purposes, and
then only with effective chip guarding and personal protective equipment as may be required
by OSHA.
SULLIVAN-PALATEK_____________________________________
Compressed air filters or lubricators with plastic bowls may be affected by the lubricant used.
Steel bowls are recommended.
Keep personnel out of line with, and away from, the discharge opening of airlines, or tools, or
other areas of direct, or deflected, compressed air discharge.
Do not allow anyone to engage in horseplay with air hoses as serious bodily injury or death
may result.
Do not substitute bolts with material or markings different from original equipment.
Do not over-tighten any bolt, nut, fitting, connection, or spin-on filter element.
1.3
FIRES / EXPLOSIONS
Clean up any spilled oil or oil leakage and repair oil leaks as soon as they are discovered.
Do not allow oil to accumulate on, in, or around acoustic noise material. Immediately replace
any oil-soaked material after cleaning enclosure surface with nonflammable solvent.
Do not operate compressor when there is a possibility of its ingesting flammable, toxic or
explosive fumes, mists or particulates.
Do not operate compressor with its temperature switch or any of three pressure switches
inoperative or incorrectly connected.
Keep conductive objects away from explosive live electrical parts such as terminals to avoid
sparks that might serve as a source of ignition.
Replace the air/oil separator element only with factory original equipment replacement parts
to be certain that anti-static provisions are present.
Ground the machine in accordance with National Electrical Code (NEC) requirements.
Do not use plastic pipe for compressed air.
1.4
MOVING PARTS
_____________________________________SULLIVAN-PALATEK
1.5
PHYSICAL DANGERS
Wear OSHA approved personal protective gear including gloves, safety shoes, safety
glasses, head covering and ear protection when working on or around the compressor.
Avoid bodily contact with hot oil, hot surfaces, sharp edges and corners. Keep all parts of
the body away from all potential points of air discharge, including pressure relief valve ports.
Keep an adequate first-aid kit nearby. Obtain medical assistance promptly in case of injury.
Do not ignore small cuts, burns or minor eye injuries as they may lead to infection.
Perform repairs and maintenance only in clean, dry conditions in a well-lighted and ventilated
area.
Operate the compressor only in open or well-ventilated areas.
Monitor the point-of-use location for adequate ventilation.
1.6
TOXICITY
Carefully analyze the compressor inlet conditions to be certain that no dangerous levels of
contaminants are being ingested by the compressor. Do not use air from this compressor for
breathing, as it may contain colorless, odorless yet lethal gases. Severe injury or death may
result within a few seconds. Do not permit air from this compressor to contact foodstuff
except in compliance with FDA Standard 21 CFM 178.3570 and all other applicable
regulations. (Use food grade lubricant for such applications.)
1.7
ELECTRIC SHOCK
Keep all parts of the body as well as any tools or other conductive objects away from
exposed live parts of the electrical system. Maintain dry footing, stand on insulating surfaces
and do not contact any other portion of the compressor when making adjustments.
Be certain that the equipment is properly grounded in accordance with NEC.
Initial installation and wiring must be done by a trained and qualified electrician and be in
accordance with all Federal, State and Local codes, standards and regulations. Improper
installation or unsafe servicing could result in serious bodily injury or death.
If a fuse should blow for any reason, replace it with a fuse of the same size, type and ampere
rating. Doing otherwise may result in an unsafe condition.
SULLIVAN-PALATEK_____________________________________
1.8
LIFTING
Lift or move the compressor only with equipment of sufficient load capacity which has been
inspected and is in good condition.
Use extreme care when moving tank-mounted compressors because of the high center of
gravity.
Firmly restrain the compressor to prevent tipping or rolling.
Keep personnel out from under and away from the area when lifting or moving the
compressor.
Lift no higher than necessary. Carry as low as possible when moving.
Keep lifting operator in attendance whenever the compressor is suspended.
Set compressor down only on level surface capable of supporting several times the
machines weight.
Do not lift entire machine by motor lifting eyes, as they are intended only for lifting the motor.
Drain condensate from Auxiliary Air Receiver prior to lifting.
1.9
AUTOMATIC START
Do not assume that any air compressor is ready for maintenance, service, or troubleshooting if it is not running. It may be in the Automatic-Start mode of its dual-control
system and suddenly re-start, thereby creating a hazardous condition!
Close discharge air valves and shut machine off. Open main disconnect; lock it out and tag it
to prevent others from inadvertently re-closing it.
1.10
NOISE
Working near an open-air compressor (or an enclosed machine with doors and/or access
panels open or removed), can prove hazardous even during short-term exposure. The noise
may interfere with hearing verbal warnings or other sounds off impending dangers. For
prolonged exposure to machinery noise, hearing protection is recommended and may be
required by OSHA.
_____________________________________SULLIVAN-PALATEK
1.11
DECAL
LOCATION
**WARNING SIGN**
HIGH VOLTAGE/MOVING PARTS
**WARNING SIGN**
COMPRESSED AIR
MOTOR STARTER
MOTOR STARTER
INSTRUMENT PANEL
INSTRUMENT PANEL
**WARNING SIGN**
HOT OIL/PRESSURIZED AIR
SEPARATOR TANK
SEPARATOR TANK
SULLIVAN-PALATEK reserves the right to change the design or construction of the above
compressors, or to offer them with options which will cause the subject equipment to differ
from the above specifications, without reference to any descriptions in this manual.
SULLIVAN-PALATEK_____________________________________
SECTION 2 - SPECIFICATIONS
2.1
LUBRICATION GUIDE
2.2
APPLICATION GUIDE
Ambient Temperature Range: +35 to +104 F (+1 to 40 C). The lower temperature limit is to
prevent freeze-up of condensate in the aftercooler and/or control lines. When operating
these compressors for plant air in food or beverage processing industries, contact the factory
for a Lubricoolant that is FDA approved for incidental contact with foodstuffs. For
instrument-grade air, contact the factory for recommendations related to specialized
compressed air preparation accessories. Contact the factory for heat-recovery equipment, or
any other specialized compressor-related accessories. Whenever a SULLIVAN-PALATEK
rotary screw air compressor is installed in parallel with a reciprocating type compressor, it is
imperative that the SULLIVAN-PALATEK be the lead machine and the reciprocating the
lag machine. That is, the SULLIVAN-PALATEK machine should be the first to start and the
last to stop when being operated in the automatic stop/start mode; or the first to load and
the last to unload, when in the continuous run mode. This will result in extending the life of
the reciprocating machine, with no adverse effect on the life of the rotary. It should also
require the least electrical power consumption for the combination.
_____________________________________SULLIVAN-PALATEK
SECTION 3 - DESCRIPTION
3.1
INTRODUCTION
SULLIVAN-PALATEK Plant Air Compressors are electric motor driven, single-stage rotary
screw type, continuous-duty compressors. The compressors design and construction offer
the greatest value and lowest life-cycle cost of operation. The compressor package includes
a direct connected electric motor driven compressor, air intake capacity control system air
cooled cooling system, including a standard air cooled aftercooler, discharge system,
instrument panel and electrical system. They are available base mounted or tank mounted
with or without enclosures. These machines are intended for indoor installation, or protected
outdoor operation in moderate climates.
For outdoor operation, contact your nearest SULLIVAN-PALATEK distributor or the factory
for specific options.
3.2
COMPRESSOR UNIT
3.3
MOTOR
30
4
40
4
10
50
4
SULLIVAN-PALATEK_____________________________________
11
_____________________________________SULLIVAN-PALATEK
3.4
INTAKE/CONTROL SYSTEM
The intake/control system consists of an air filter, connecting rubber sleeve, clamps, a
combination compressor inlet valve/reverse-flow check valve, control signal regulator valve,
solenoid control/blowdown valve, and a control pressure switch. (See Intake Control
Schematic.) The air filter is a multi-stage dry-type with a high efficiency
cleanable/replaceable element. The element should be cleaned periodically, depending
upon the amount of particulates in the air, and replaced annually. This filter is adequate for
areas of high air-borne dust concentrations and has a tubular intake to facilitate remote
intake connection to cooler, cleaner air and/or for reduced noise level.
The intake valve controls the capacity or air delivery of the compressor in direct response to
the plant air system demand via a varying signal from the control regulator valve. During
periods of very low or zero air usage the inlet valve is held shut by an air signal from the
solenoid control/blowdown valve. This air signal simultaneously reduces the pressure in the
oil separation tank, allowing the compressor to run unloaded with minimum power
consumption. Upon shutdown the intake valve checks shut to eliminate blowback.
Control operation - start mode: When the compressor is turned on, or starts automatically,
the pressure will quickly rise to 60 psi (415 kPa), which is the setting of the minimum
pressure valve. The control regulator and solenoid valve are both closed; therefore, the
compressor inlet valve is wide open. The compressor is then drawing in its full rated
capacity, but the air is held back by the minimum pressure valve. Upon reaching 60 psig the
minimum pressure valve opens allowing the compressor to deliver its full rated capacity to
the plant air piping system.
Modulating mode: Whenever less than the rated capacity of the compressor is being used,
the service air pressure will continue to rise until the control regulator gradually opens. This
applies pressure to the inlet valve piston, thus partially closing the inlet valve disc reducing
the amount of air entering the compressor air inlet until it matches the amount of air being
used. The control will function continually in this manner between the adjustable limits of 115
to 125 psi (750 to 860 kPa) in response to varying demands of the plant air system. The
control regulator has an orifice in the controller piston, which vents a small amount of control
air whenever it is sending a pressure signal to the intake controller capacity control. This
orifice is vital to the smoothness of the control operation, and must not be restricted.
Unloaded/Shutdown modes: When little or no air is being used, the service line pressure will
rise to the cut-out setting of the control pressure switch. This opens the control solenoid,
which sends a pressure signal directly to the inlet valve piston. The inlet valve is held shut,
while air is vented through an orifice fitting which reduces the pressure in the separation
tank. With the selector switch in the Run position, the compressor runs unloaded until air
demand increases. With the resumption of plant air usage, the line pressure signal is
reduced to the cut-in setting of the control pressure switch where it closes. Then control air
signal to the inlet valve will be dissipated allowing the inlet valve to reopen. The compressor
returns to normal full load operation. Selecting the Auto position on the selector switch
allows the motor to shut off whenever the cut-out pressure setting of the control pressure
switch is reached. It remains in this unloaded mode for 10 minutes before shutting off. The
compressor will restart whenever the line pressure drops to the cut-in pressure.
12
SULLIVAN-PALATEK_____________________________________
3.5
The cooling system consists of a fan, finned-tube radiator-type fluid cooler, thermal valve to
accelerate warm-up, a full-flow filter, an oil drain valve and interconnecting tubing. Pressure
in the oil separation tank causes the lubricoolant to flow from this region of relatively high
pressure, through the system to an area of lower pressure at the compressor unit. Fluid
flows from the oil separation tank to the cooler, from the cooler to the filter, and from the filter
to the compressor. During cold starts, the fluid will by-pass the oil cooler and go directly to
the filter. While warming gradual change occurs where the fluid flow is split, partial flows
being shared by both the oil cooler and by-pass through the thermal valve. When fully
warmed up, the thermal valve is closed and all the lubricoolant flows through the cooler. The
fluid filter is of the spin-on replacement element type. The element should be changed in
accordance with the Maintenance Schedule on page 22. A drain valve is provided to drain
the lubricoolant at change-out time.
13
_____________________________________SULLIVAN-PALATEK
3.6
The compressor unit discharges a mixture of compressed air and lubricoolant directly into the
oil separation tank where it accomplishes the following three functions:
A) Primary Separation - by change of direction and reduction of velocity, which allow the
heavier droplets of lubricoolant to fall.
B) Serves as the lubricoolant sump - by collecting the hot lubricoolant, prior to re-circulation
through the cooling system.
C) Houses the final oil separation element - a replaceable, multi-layered, multi-media
coalescing element with pleated initial stage for reduced velocity, improved separation
performance and extended service life. Separated oil is returned to the compressor oil
system via a small diameter return line, or scavenger tube.
A sight gauge is provided to monitor the lubricoolant level in the oil separation tank. A
capped oil fill port is provided to keep the oil at the proper level and to refill the system after
changing the lubricoolant.
WARNING: Do not remove caps, plugs or other components or connections while the
compressor is running or pressurized. Shut compressor off, open and lock electrical
disconnect, and relieve all sump pressure before doing so.
The oil separation tank is ASME rated for 200 psi (1379 kPa) maximum working pressure. A
combination minimum- pressure/check valve in the separator cover assures a minimum
pressure of 60 psig (415 kPa) for proper lubricoolant circulation and separation. It prevents
reverse flow of compressed air from the auxiliary air receiver and/or the plant air system back
through the compressor at shutdown or during periods of unloaded operation. A pressure
relief valve (located upstream, or on the wet side of the separator) is set to open if a control
malfunction would allow the pressure to exceed 150 psig (1035 kPa). (High-pressure units
can be set to operate at control pressures from 175 to 190 psig.) However, since the
opening of this valve is noisy and results in hot oil being expelled, a receiver over pressure
switch has been installed to shut the motor off at 140 psig (190 psi on high pressure units.).
The panel-mounted pressure gauges show the pressure in the oil separation tank and line
pressure. The compressor discharge temperature gauge is also panel-mounted for ease of
record keeping and trouble-shooting. Normal discharge temperature should be
approximately 180-220 F (82-105 C), or about 100 F (55 C above ambient). A C.D.T.
switch is provided to shut the motor off if the compressor discharge temperature exceeds
240 F (115 C) in the event of gradual reduction in cooling system efficiency coupled with
unattended operation. The reaction time of the switch is, however, not rapid enough to stop
the compressor in the event of a sudden or complete loss of lubricoolant.
Additionally, differential pressure gauges showing the pressure drop across the oil filter and
the separator element are supplied as an assist to proper maintenance of these elements.
14
SULLIVAN-PALATEK_____________________________________
WIRING DIAGRAM - FULL VOLTAGE STARTER
15
_____________________________________SULLIVAN-PALATEK
3.7
The three-phase electric motor starter supplied with the SULLIVAN-PALATEK Plant Air
Compressor has a NEMA-1 rated enclosure. This is also the location of: the control power
transformer, the Run-On-Off-Reset, Auto Start selector switch, a control relay, the control
pressure switch, the over-pressure shutdown switch and the anti-restart pressure switch.
The starter contactor is amp-rated to match the motor power. That is 230 volts for the 30 hp
machine and 460 volts for the 40 and 50 hp machines. Overloads must be selected and set
to match the motor voltage/full load amp rating for each voltage application.
The selector switch allows the operator to select Run for continuous operation mode,
where the motor runs continuously while the compressor loads and unloads, as required, to
match air demand. This mode is generally used only if one wants to minimize motor starts.
The Off-Reset position is used to shut the compressor off and to reset the electrical control
system following an automatic shutdown due to an over-temperature or over-pressure
condition.
The Auto-Start position allows the compressor to shut down automatically whenever the
auxiliary air receiver or plant air system pressure reaches the top (Cut-out) setting of the
control air pressure switch. This relays a signal to the control relay, initiating a 10-minute
timer, which then releases the motor starter pull-in coil stopping the motor. The motor will
restart as soon as the plant air pressure drops to the cut-in setting on the pressure switch,
provided that the oil separation tank pressure has been relieved via the blowdown valve.
The compressor is prevented from starting under pressure by the anti-restart switch is in its
normally closed mode. (This control mode saves power during periods of little or no air
usage, and a timer is utilized to limit motor starts.)
The over-pressure shutdown switch acts to stop the compressor in the event of control
malfunction or improper adjustment in order to prevent the pressure relief valve on the oil
separation tank from suddenly opening.
The control power transformer converts power from one phase of the incoming motor power
to a lower voltage for activation of control features. The primary (high voltage) incoming
power and the secondary (control voltage) circuits are both provided with breakers to
minimize the potential for damage due to overloading or short-circuit faults.
3.8
INSTRUMENTATION
Each SULLIVAN-PALATEK Plant Air Compressor is equipped with two pressure gauges:
one to monitor the sump tank pressure, another reading line pressure. There is a
temperature gauge which senses compressor discharge temperature. In addition, there are
two differential pressure gauges sensing the pressure drop across the oil filter and the
separator element. It is recommended that the separator is changed when 5psid is reached,
and the oil filter is changed when 15psid is reached. The compressor hour meter is located
in the electrical box or on its door.
16
SULLIVAN-PALATEK_____________________________________
SECTION 4 - INSTALLATION
4.1
RECEIVING
4.2
WELDING
Do not weld on compressor package.
4.3
LOCATION
The compressor is designed for indoor operation or protected outdoor site with an ambient
temperature range of 35 to 104 F (1 to 40 C). It is important that there be sufficient
unobstructed ventilation airflow to prevent re-circulation of hot air. The compressor should
be in a clean, dry and well-lighted area with ample space for maintenance and servicing.
Duct the hot air outside if necessary to prevent excessively high ambient temperatures.
Below is a listing of heat loads and fan air volumes that must be accommodated to keep
machines operating normally. It is possible to utilize this heat for space heating, combustion
air pre-heating, product drying, etc., - providing that no additional restriction is imposed upon
the compressor cooling fan. Consult the factory for assistance if heat recovery is desired, or
if other ambient temperatures are present.
MODEL
AIR FLOW (CFM)
HEAT REJECTION BTU/HR
30DG
4600
81,408
40DG
5000
109,392
50DG
5300
137,376
Locate compressor as close as practical to where the compressed air is to be utilized. This
saves piping and reduces power requirements necessary to transmit compressed air long
distances.
4.4
SUPPORT
The compressor may be mounted on any level surface capable of supporting its weight. It is
recommended that the machine be mounted on isolation pads and secured to prevent
movement.
4.5
ELECTRICAL CONNECTIONS
Electrical wiring to the motor starter must be done by a qualified electrician in accordance
with all pertinent Federal, State and Local codes concerning isolation switches, short circuit
protection, grounding, etc.
Check all electrical connections for tightness!
Check incoming voltage to be sure the motor is properly connected to match the starter and
the overloads are properly set.
When power wiring has been installed, engage disconnect and bump compressor by
turning to Run and then back to Off. Check for compressor proper rotation by: a.)
Observing coupling rotation, b.) Observing pressure build up on sump gauge. If rotation is
incorrect switch any two of the incoming lines after opening disconnect. Once re-energized
the compressor should be ready to turn on.
17
_____________________________________SULLIVAN-PALATEK
4.6
The compressor package has differential pressure gauges for change out indication for the
separator element and fluid filter. Change differentials are indicated as follows: Separator
element: 10 PSID, Fluid filter: 20 PSID, or once per year, whichever comes first.
4.7
DIRECTION OF ROTATION
Once the control circuit has been checked, all piping installed, and the compressor lubricant
level has been checked - reconnect the three motor leads by momentarily moving the
selector switch to the Run position and then back to the Off/Reset position to check for
correct compressor rotation. Rotation should be clockwise when viewed from the motor (i.e.
looking in at compressor shaft)
Note: In all cases, the fan air should blow out, away from the motor.
4.8
Connect the compressor to the plant air system with a flexible connector rated for at least
200 psi (1400 kPa) and 275 F (135 C). Support the piping to insure that no pipe stress is
transmitted to any compressor component. Piping should be as large as possible to provide
extra air storage capacity and minimize transmission losses. Air dryers and filters may be
required. Piping should be in a closed loop configuration, sloping to drain points, with
service air outlets taken from the side, or preferably, the top of the pipe. Point-of-use filters,
coalescers, regulators and/or lubricators are often required. (Note: never use plastic air
piping or plastic bowls on filters or lubricators. See Section 1.) Inspect piping and air hoses
frequently for leaks.
4.9
ADDITIONAL HELP
By supplying the cleanest, coolest air available to the compressor inlet, maintenance and
power consumption will be minimized. The heavy-duty air filter is locally mounted with
provision for remote connection. Use a flexible connector at the filter inlet. (3 diameter.)
Keep the piping as short and as straight as possible. Intake duct must be the same size as
filter inlet, or larger, to accommodate long runs and several bends. Support intake ducting
properly to prevent its weight being transmitted to the compressor air filter.
For multiple machine installation, contact the factory for special sequencing controls that can
reduce power cost during part-load operation. Fan air ducted outside will reduce the
machine noise somewhat, but care must be taken not to impose additional restriction to the
fan airflow. With proper attention to the ducting, this fan air can also be utilized for heating
purposes.
18
SULLIVAN-PALATEK_____________________________________
SECTION 5 - OPERATION
5.1
INTRODUCTION
Read this entire Operators Manual to familiarize yourself with the SULLIVAN-PALATEK
Plant Air Compressor, giving special attention to the SECTION 1 - SAFETY.
5.2
1.
2.
3.
4.
5.
6.
INITIAL START
Open main disconnect to be sure there is no power to the compressor.
Review all the steps covered in Section 4 - INSTALLATION to be certain all
instructions have been complied with.
Inspect for any visible signs of damage that could have occurred during installation.
Check lubricoolant level. Tighten oil-fill cap.
Close main disconnect.
Jog motor (move selector switch to the Run position momentarily, then immediately
back to Off/Reset) to check direction of rotation - looking at the fan from the tank
end, rotation should be as indicated on page 18. If rotation is wrong, open main
disconnect and then exchange any two of the three incoming leads L1, L2 or L3.
CAUTION: Reverse rotation will cause damage that is not covered by warranty.
Rotation must be checked whenever the compressor has been moved to a new
location, or after any change or reconnection of the main electrical wiring.
7.
11.
After closing the starter cover door, close the main disconnect and start the
compressor in either the Run or Auto Start/Stop mode.
With service air valve closed, allow machine to pump up to normal operating
pressures and observe operation of automatic controls, and check for any possible
leaks.
Open service air valve, check operation throughout a range of pressures and observe
operating temperatures.
Turn selector switch to Off-Reset and check lubricoolant level after it has been
allowed to settle for a few minutes. If it is necessary to add lubricoolant, be sure to
relieve all oil separation tank pressure prior to removing fill cap.
If unloaded pressure is incorrect, re-adjust pressure switch settings as required.
5.3
NORMAL OPERATION
8.
9.
10.
1.
2.
3.
4.
5.
6.
5.4
SHUTDOWN
To stop compressor, move selector switch to Off-Reset position. If motor does not stop,
open disconnect switch, then repair as necessary.
19
_____________________________________SULLIVAN-PALATEK
5.5
RESTARTS
After a power failure, open and lock out the main disconnect, check all fuses and move
selector switch to Off-Reset position. Close disconnect switch and follow Normal Operation
start-up procedure.
Following a shutdown caused by either of the protective switches (i.e. cdt, or rop), open and
lock out the main disconnect switch. Correct the cause of shutdown and reset electrical
controls. Then close the disconnect and follow Normal Operation start-up procedure.
If the overload has tripped the motor off, first open and lock out the disconnect, then push the
starter overload reset button and check to be sure it is set properly and correctly adjusted.
NOTE: Never adjust the overload higher than indicated by starter manufacturer to match
motor nameplate amperage rating; an unsafe operating condition will result!
20
SULLIVAN-PALATEK_____________________________________
SECTION 6 - MAINTENANCE
6.1
SCHEDULE
Daily 1.
2.
3.
4.
When using Palasyn 45: Every 4,000 hours or once a year, whichever occurs
first Drain lubricoolant and replace with a fresh charge. Inspect interior of tank. Clean tank if any
build-up of deposits is present. This may have to be done sooner depending upon results of
lubricoolant analysis. Replace air/oil separator element and the air filter element.
When using Pallube 32p: Every 8,000 hours Change Pallube 32p lubricoolant and inspect tank interior. Replace air/oil separator element.
Replace air and oil filter.
When using Pal Extra 44: Every 10,000 hoursChange AFX 32 and inspect tank interior. Replace air/oil separator, as well as air and oil
filter element.
As Required 1.
2.
3.
4.
Clean or replace air filter element (P/N 00521-060 for 30 and 00521-082 for 40 & 50
HP).
Clean exterior surfaces of oil cooler/aftercooler.
Clean and grease MPV with a Lithium Grease ex: Lubriplate 630-2 or Mobil SHCPM.
Rebuild inlet valve every two years.
21
_____________________________________SULLIVAN-PALATEK
6.2
OIL FILTER
6.3
AIR FILTER
6.4
AIR/OIL SEPARATOR
6.5
22
SULLIVAN-PALATEK_____________________________________
6.6
PRESSURE ADJUSTMENT
Two capacity control features are incorporated in the Sullivan-Palatek compressors. The
control pressure switch (CPS) will cycle the compressor between loaded and unloaded
operation. This switch should be set so that the compressor loads when the line pressure
falls to the lowest pressure required to operate plant equipment, and unloads the compressor
at some higher pressure (normally about 10 psi above load pressure.) The other means of
controlling compressor out-put is by means of the modulating or regulating valve. The
modulating valve will proportionally pinch shut the inlet valve depending upon the existing
line pressure.
To set the compressor controls, follow the following steps:
1. Turn in on modulating valve adjusting screw about one turn (this is to remove this
control while setting the CPS).
2. Adjust the cut-out pressure by turning the top adjusting screw (CW to raise the
pressure, CCW to lower).
3. Adjust the cut-in pressure by turning the lower adjusting screw. CW to decrease the
cut-in; CCW to increase the cut-in pressure.
4. One the CPS has been set to the desired valves, the modulating valve must be reset.
Loosen the adjusting screw until air is being vented from regulator at a pressure
about 5 psi below the set cut-out pressure of the CPS. Lock adjusting screw in place.
Note that the selector switch on the electrical box has three settings; Run, Off/Reset, and
Auto. In the Auto position the compressor will shut off after running unloaded for 15
minutes. In the Run mode the compressor motor is never shut off. For maximum efficiency
of operation, if it is intended to operate the compressor in the Auto mode, the pressure
settings should have as large a differential as practical to allow the compressor to time out
and shut off (consult factory for other optional energy saving options.)
23
_____________________________________SULLIVAN-PALATEK
6.7
TROUBLESHOOTING
SYMPTOM
A. Machine will not start.
SYMPTOM
B. Machine shuts down with air demand
present.
24
SULLIVAN-PALATEK_____________________________________
TROUBLESHOOTING, CONT
SYMPTOM
B. Machine shuts down with air demand
present.
SYMPTOM
C. Machine will not build up full discharge
pressure.
1.
2.
3.
4.
5.
6.
SYMPTOM
D. Line pressure rises above cut-out
pressure.
25
_____________________________________SULLIVAN-PALATEK
TROUBLESHOOTING, CONT
SYMPTOM
E. Excessive lubricoolant consumption
1.
2.
3.
4.
SYMPTOM
F. Pressure relief valve opens repeatedly.
SYMPTOM
G. Receiver pressure venting through
blowdown.
26
SULLIVAN-PALATEK_____________________________________
PIPING & INSTALLATION DRAWING
27
_____________________________________SULLIVAN-PALATEK
PARTS LISTING
28
SULLIVAN-PALATEK_____________________________________
SCREW COMPRESSOR AIR-END EXCHANGE PROGRAM
After the warranty period has expired a factory re-manufactured air-end can be purchased on
an exchange basis. All bearings and seals have been replaced. All other parts not meeting
our quality standards are also replaced. The air end is then factory tested prior to shipment.
A re-manufactured air-end has a warranty which is 12 months from start up date or 18
months from date of shipment in accordance with the terms set forth in the new air-end
warranty found on pages 42 & 43.
29
_____________________________________SULLIVAN-PALATEK
SECTION 7 - PARTS LISTING
7.1
PARTS ORDERING
Parts should be ordered from the nearest full-service Distributor or Factory Authorized
Compressor Center. If parts cannot be obtained locally, contact the factory.
SULLIVAN-PALATEK
3501 W. Dunes Hwy.
Michigan City, IN 46360
Telephone: 219-874-2497 FAX: 219-872-5043
E-mail: info@palatek.com
When ordering parts, be prepared to indicate the MODEL and SERIAL NUMBER of the
machine(s). This can be obtained from the Bill of Lading or the Serial Number Plate.
Standard commercial hardware items such as fasteners or fittings may not be listed since it
is usually more convenient and economical to obtain such items locally.
1.2
DESCRIPTION
30HP Air Filter Element
40HP Air Filter Element
50HP Air Filter Element
Oil Filter 30-40 hp
Oil Filter 50 hp
30DG Air/Oil Separator Element
40DG Air/Oil Separator Element
50DG Air/Oil Separator Element
Valve, Sol, 2 way, 115 vac 30hp (40/50hp)
Regulator Control Valve
Pressure Relief Valve 200 psi
Gasket Inlet to Stator 30/40 hp
Gasket Inlet to Slator 50/60hp
MPV (Repair Kit)
Switch, Compressor Temperature
Switch, Pressure Anti-Restart
Switch, Control Pressure
Switch, Compressor Overpressure
Seal, Shaft Assembly
Timer, Solid State, 10 minutes
Element Thermostat (Higher Temp)
Valve, Blowdown
Valve, Pilot
Valve, Check (DBL.)
***Palasyn 45 Lubricoolant (5 Gal)
***Pallube 32 Lubricoolant (5 Gal)
***Pal-Extra 44 Lubricoolant (5 Gal)
***Food Grade Lubricant (5 Gal)
PART NUMBER
00521-060 / 060S
00521-082 / 082S
00521-082 / 082S
00520-017
00520-015
KB08000-022
KB08000-022
KB08000-022
40529-010 (011)
09661-002
03100-008
00633-014
00633-127
K09610-001
00438-008
09344-001
09345-004 (006)
09344-003
K09147-127SV
69500-210
09505-004 (-006)
09660-012
09662-001
09791-001
00061-005
00064-005
00066-005
00062-005
30
QUANTITY
2
2
2
4
4
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
2
2
2
2
SULLIVAN-PALATEK_____________________________________
MOTOR, COMPRESSOR, AND MOUNTING PARTS
31
_____________________________________SULLIVAN-PALATEK
7.3
MODEL
30DG
MODEL
40DG
MODEL
50DG
AIR END
80108-230
80108-279
80127-231
1A
K09147-363
SLEEVE, WEAR
00371-200
00419-200
00633-032
RING, RETAINING
01246-250
SEAL, SHAFT
09148-200
BASE
10144-060
10144-060
10144-060
COUPLING GUARD
00697-016
00697-016
00697-017
MOTOR SUPPORT
18339-001
18339-023
18339-043
ISOLATOR
N/A
N/A
08182-009
COUPLING
18516-060
18516-060
18516-060
COUPLING ELEMENT
08516-079
08516-079
08516-079
MOTOR 230/460
08747-430
08747-044
08747-054
08339-021
18739-045
18339-044
ITEM
1
5
5A
DESCRIPTION
32
SULLIVAN-PALATEK_____________________________________
LUBRICATION & COOLING SYSTEM
33
_____________________________________SULLIVAN-PALATEK
7.4
QTY
MODEL
30DG
MODEL
40DG
MODEL
50DG
COOLING FAN
08080-117
08080-046
08080-053
OIL COOLER/
AFTERCOOLER
07711-202
07711-203
07711-011
VITON O-RING
90659-121
90659-121
90659-121
THERMOSTAT *
(Higher Temp. -180q F)
09505-006
09505-006
09505-004
BY-PASS HOUSING
08207-055
08207-054
08207-054
O-RING
00660-010
00660-012
00660-012
09610-017
09600-322
09600-329
80120-010 (a)
80120-012 (b)
80120-012 (b)
09610-018
09600-324
09600-328
96391-108 (a)
96390-012 (b)
96390-012 (b)
ITEM
7
8
10
11
TUBE - SUMP TO
THERMOSTAT
TUBE CONN.: 5/8 X .875M (a)
TUBE CONN.; 3/4 X 1.06M (b)
TUBE - THERMOSTAT TO
FILTER**
TUBE ELBOW: 5/8 X 1/2 (a)
TUBE ELBOW: 3/4 X 3/4 (b)
12
08415-007
08415-007
08415-016*
14
00520-017
00520-017
00520-015*
19
FAN SPACER
N/A
N/A
N/A
20
FAN HUB
00851-002
00851-003
00851-003
21
FAN KEY
00858-001
00858-001
90947-126
22
SHROUD
13400-105
03400-018
03400-018
23
FAN GUARD
03216-105
03216-005
03216-005
#00549-001
#00549-001
#18338-008
50 hp Model
Oil Cooler
After Cooler
Water Reg. Valve
#00549-003
#00549-005
#18338-012
40 hp Model
Oil Cooler
After Cooler
Water Reg. Valve
34
#00549-003
#00549-002
#18338-012
SULLIVAN-PALATEK_____________________________________
INTAKE AND CAPACITY CONTROL SYSTEM
35
_____________________________________SULLIVAN-PALATEK
7.5
ITEM
QTY
MODEL
30DG
MODEL
40DG
MODEL
50DG
MOUNTING BAND
00131-060
00131-082
00131-082
00077-253 (a)
00077-353 (b)
91411-535 (c)
00521-060
00521-082
00521-082
INTAKE VALVE1
09790-006
09790-006
09790-012
BLOWDOWN VALVE
40529-010
40529-011
40529-011
09661-002
09661-002
09661-002
6A
K09661-002
K09661-002
K09661-002
09345-006
09345-006
09345-006
28174-060
28174-082
18174-088
10
HOSE CLAMP
92320-128
92320-128
92320-128
10A
HOSE CLAMP
92320-080
92320-144
92320-208
11
08339-034
08339-026
08339-024
12
ORIFICE
N/A
N/A
N/A
13
ROP SWITCH
09344-003
09344-003
09344-003
14
ANTI-START SWITCH
09344-001
09344-001
09344-001
Recommend Rebuilding Inlet Valve with K09790-007 Kit for 30DG-40G every 2 years.
Recommend Rebuilding Inlet Valve with K09790-009 Kit for 50DG every 2 years.
36
SULLIVAN-PALATEK_____________________________________
DISCHARGE SYSTEM
37
_____________________________________SULLIVAN-PALATEK
7.6
DISCHARGE SYSTEM
QTY
MODEL
30DG
MODEL
40DG
MODEL
50DG
1 MINIMUM PRESSURE
VALVE
09610-001
09610-001
09610-001
SEPARATOR ELEMENT
KB08000022
KB08000022
KB08000022
SUMP TANK
03448-052
03448-052
03448-052
VENTED CAP
07255-016
07255-016
07255-016
17254-016
17254-016
17254-016
MALE ELBOW
96399-004
96399-004
96399-004
95784-004
95784-004
95784-004
03100-008
03100-008
03100-008
10
29349-064
29349-064
29349-064
10A
03001-064
03001-064
03001-064
10B
STRAINER
18577-001
18577-001
18577-001
10C
SIGHT GLASS
09349-001
09349-001
09349-001
10D
ADAPTER
00023-001
00023-001
00023-001
11
09062-033
09062-033
09062-033
12
09616-066
09600-305
09600-305
13
CONNECTOR
96363-161
96363-202
96363-202
14
SIPHON FITTING
03286-003
03286-003
03286-003
14A
GROMMET
00547-001
00547-001
00547-001
15
ELBOW, AC (N.I.)
96390-161
96390-202
96390-202
16
BOLT, GRD 8
X1
X1
X1
17
PIPE DISCHARGE
19600-035
19600-035
19600-034
19
FLANGE
91001-008
91001-008
91001-008
20
90708-005
90708-005
90708-005
ITEM
DESCRIPTION
1*
38
SULLIVAN-PALATEK_____________________________________
GAUGE PANEL & ELECTRICAL PARTS
39
_____________________________________SULLIVAN-PALATEK
7.7
GAUGE, TEMPERATURE
MODEL
30DG
08312-025M
GAUGE, PRESS
09174-325
09174-325
09174-325
09175-001
09175-001
09175-001
ITEM
3**
3A**
DESCRIPTION
QTY
MODEL
40DG
08312-025M
MODEL
50DG
08312-025M
09175-030
09175-030
09175-030
SWITCH 3-POSITION
00701-795
00701-795
00701-795
HOURMETER,AC 120V
00735-120
00735-120
00735-120
09345-006
09345-006
09345-006
PANEL 15 GAUGE
00944-007
00944-007
00944-007
8*
07103-015
07103-015
07103-015
09344-001
09344-001
09344-001
10
09344-003
09344-003
09344-003
11
SOLENOID VALVE
40529-010
40529-011
40529-011
LIGHT, POWER ON
00347-004
00347-004
00347-004
SWITCH, CDT
00438-008
00438-008
00438-008
12
NI
40
SULLIVAN-PALATEK_____________________________________
7.8
MODEL
30DG
03832-043
08377-033
08377-033
08377-022
08377-022
08377-001
08377-001
DECAL, WARNING
08377-043
08377-043
DECAL, WARNING
08377-045
08377-045
DECAL, WARNING
08377-046
08377-046
08378-048
08378-048
DECAL, INSTRUCTIONS
08379-020
08379-021
10
DIAGRAM, WIRING
12288-001
12288-001
11
DECAL, WARNING
08378-065
08378-065
12
08379-101
08379-101
13
00447-001
00447-001
14
00447-002
00447-002
15
OMP3060-003
OMP3060-003
KEY
DESCRIPTION
QTY
41
MODEL
40/50DG
03832-043
_____________________________________SULLIVAN-PALATEK
SECTION 8 - WARRANTY
2008 Sullivan-Palatek
Warranty
New Industrial Compressors - 15 and greater Horsepower
Sullivan-Palatek warrants its new stationary industrial air compressor products to be free from defects in material and workmanship and
against loss of capacity due to wear, subject to the following provisions:
Warranty Registration: The purchaser shall complete and return the warranty registration form within 10 days of start-up to validate
the warranty. Failure to submit the warranty registration will cause the warranty effective date to be the Sullivan-Palatek ship date.
Warranty Period: The warranty period for applicable Sullivan-Palatek products is as follows (subject to the Exclusions and Limitations
noted below):
x
x
x
x
x
x
Total Package: 12 months (1 year) from the date of start-up by authorized distributor or 18 months from date of shipment by
Sullivan-Palatek, whichever expires first.
Compressor unit and Coupling Assembly: 24 months (2 years) from the date of start-up by authorized distributor or 30
months from date of shipment by Sullivan-Palatek, whichever expires first.
Compressor Motor: 24 months (2 years) from the date of shipment by Sullivan-Palatek.
Compressor Shaft Seal: Warranted for 12 months (1 year) from date of start-up or 18 months from date of shipment by
Sullivan-Palatek, whichever expires first.
Components not manufactured by Sullivan-Palatek: Sullivan-Palateks warranty obligation with regard to equipment and
components not of its own manufacture is limited to the warranty actually extended to the company by its supplier.
Oil Leaks: Oil leaks will be covered under warranty for a period of 60 days from start up, but not longer than 90 days after
shipment from Sullivan-Palatek. These are defined as an escape of air or oil that only requires tightening to stop the leak.
Other leaks are considered a failure of sealant or application thereof, or a part or assembly error and are covered for one
year due to defects in workmanship, or to the limit of the manufacturers warranty.
Warranty replacement parts: Remainder of the original warranty period for the replaced part.
Sullivan-Palateks Obligations: Sullivan-Palateks exclusive obligations with respect to breach of warranty are (i) to repair or replace
(at Sullivan-Palatek option and subject to return of defective parts) any defective part, (ii) to pay the reasonable cost of making the
repair, or installing the replacement part, except the motor after the first year, (iii) to pay ground freight for the return of defective parts
and shipment of replacement parts.
Customer Responsibility: As a condition to Sullivan-Palateks obligations under this warranty, customer shall; (i) give Sullivan-Palatek
written notice of warrantable failure of the Sullivan-Palatek product within the applicable warranty period, (ii) make the product available
for repair; (iii) return defective parts to Sullivan-Palatek; (iv) pay reasonable travel expenses for field repairs performed at customers
request, (v) pay the costs of investigating performance complaints that are not covered by this warranty; and (vi) pay costs of air freight
or other expedited delivery made at customers request.
Exclusions and Limitations: Disassembly of the air compressor unit will void this warranty and the unit exchange policy. SullivanPalatek has no obligation for product failures or defects resulting from overload, misuse, neglect, accident, failure to comply with
Sullivan-Palateks product manual or failure to install product improvements provided by Sullivan-Palatek Attachment of accessories or
service parts not supplied or recommended by Sullivan-Palatek may void the warranty of the product.
THIS WARRANTY IS SULLIVAN-PALATEKS ONLY WARRANTY OF ITS STATIONARY INDUSTRIAL AIR COMRESSOR
PRODUCTS AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, STATUTORY OR OF FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED. SULLIVANPALATEK HAS NO OBLIGATION UNDER THIS WARRANTY OR OTHERWISE (REGARDLESS OF THE FORM OF ACTION)
FOR SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY CHARTER, INCLUDING WITHOUT
LIMITATION, LOSS OF USE OF PRODUCTIVE FACILITIES OR EQUIPMENT LOST PROFITS, LOST INCOME, PROPERTY
DAMAGE, EXPENSES INCURRED IN RELIANCE ON THE PERFORMANCE OF SULLIVAN PALATEK WHETHER
SUFFERED BY THE BUYER OR ANY THIRD PARTY. THE TOTAL RESPONSIBILITY OF SULLIVAN PALATEK FOR
CLAIMS, LOSSES, LIABILITIES OR DAMAGES, WHETHER IN CONTRACT OR TORT ARISING OUT OF OR RELATED TO
ITS PRODUCTS SHALL NOT EXCEED THE PURCHASE PRICE.
This warranty applies to all Sullivan-Palatek stationary industrial air compressors of 15 horsepower or greater
shipped after January 1, 2008 superseding previous warranty policies, except to the extent expressly superseded
by a later warranty. In the event of any conflict between this warranty and earlier warranty statements, the terms
of this warranty will control.
42
SULLIVAN-PALATEK_____________________________________
2008 Sullivan-Palatek
Platinum Warranty
New Industrial Compressors - 15 and greater Horsepower
Sullivan-Palatek warrants its new stationary industrial air compressor products to be free from defects in material and workmanship and
against loss of capacity due to wear, subject to the following provisions:
Warranty Registration/Activation: The purchaser shall complete and return the platinum warranty registration/ startup card supplied
with the machine within 10 days of start-up to validate the warranty. All information required on the cards must be filled out along with
the customers signature and date in order to activate.
x
Service must be maintained as stated in the operators manual and properly logged. A maintenance log shall be available at
www.palatek.com and it is required to be updated after each service. (Distributor is responsible for maintaining the records
and keeping the service log required. Copies of Invoices for service work and the log are required at time of warranty
request)
Use genuine Sullivan Palatek parts and fluids
Warranty Period: The warranty period for applicable Sullivan-Palatek products is as follows (subject to the Exclusions and Limitations
noted below):
x
x
x
x
x
x
Total Package: 12 months (1 year) from the date of start-up by authorized distributor or 18 months from date of shipment by
Sullivan-Palatek, whichever expires first.
Compressor Unit, Air/Oil Cooler, Sump Tank, and Coupling Assembly (halves): 60 months (5 years) from the date of
start-up by authorized distributor or 62 months from date of shipment by Sullivan-Palatek, whichever expires first.
Compressor Motor: 60 months (5 years) from the date of shipment by Sullivan-Palatek.
Compressor Shaft Seal and Coupling Element: Warranted for 12 months (1 year) from date of start-up or 18 months from
date of shipment by Sullivan-Palatek, whichever expires first.
Components not manufactured by Sullivan-Palatek: Sullivan-Palateks warranty obligation with regard to equipment and
components not of its own manufacture is limited to the warranty actually extended to the company by its supplier.
Oil Leaks: Oil leaks will be covered under warranty for a period of 60 days from start up, but not longer than 90 days after
shipment from Sullivan-Palatek. These are defined as an escape of air or oil that only requires tightening to stop the leak.
Other leaks are considered a failure of sealant or application thereof, or a part or assembly error and are covered for one
year due to defects in workmanship, or to the limit of the manufacturers warranty.
Warranty replacement parts: Remainder of the original warranty period for the replaced part.
Sullivan-Palateks Obligations: Sullivan-Palateks exclusive obligations with respect to breach of warranty are (i) to repair or replace
(at Sullivan-Palatek option and subject to return of defective parts) any defective part, (ii) to pay the reasonable cost of making the
repair, or installing the replacement part, except the motor after the first year, (iii) to pay ground freight for the return of defective parts
and shipment of replacement parts.
Customer Responsibility: As a condition to Sullivan-Palateks obligations under this warranty, customer shall; (i) give Sullivan-Palatek
written notice of warrantable failure of the Sullivan-Palatek product within the applicable warranty period, (ii) make the product available
for repair; (iii) return defective parts to Sullivan-Palatek; (iv) pay reasonable travel expenses for field repairs performed at customers
request, (v) pay the costs of investigating performance complaints that are not covered by this warranty; and (vi) pay costs of air freight
or other expedited delivery made at customers request.
Exclusions and Limitations: Disassembly of the air compressor unit will void this warranty and the unit exchange policy. SullivanPalatek has no obligation for product failures or defects resulting from overload, misuse, neglect, accident, failure to comply with
Sullivan-Palateks product manual or failure to install product improvements provided by Sullivan-Palatek Attachment of accessories or
service parts not supplied or recommended by Sullivan-Palatek may void the warranty of the product.
THIS WARRANTY IS SULLIVAN-PALATEKS ONLY WARRANTY OF ITS STATIONARY INDUSTRIAL AIR COMRESSOR
PRODUCTS AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, STATUTORY OR OF FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED. SULLIVANPALATEK HAS NO OBLIGATION UNDER THIS WARRANTY OR OTHERWISE (REGARDLESS OF THE FORM OF ACTION)
FOR SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES OF ANY CHARTER, INCLUDING WITHOUT
LIMITATION, LOSS OF USE OF PRODUCTIVE FACILITIES OR EQUIPMENT LOST PROFITS, LOST INCOME, PROPERTY
DAMAGE, EXPENSES INCURRED IN RELIANCE ON THE PERFORMANCE OF SULLIVAN PALATEK WHETHER
SUFFERED BY THE BUYER OR ANY THIRD PARTY. THE TOTAL RESPONSIBILITY OF SULLIVAN PALATEK FOR
CLAIMS, LOSSES, LIABILITIES OR DAMAGES, WHETHER IN CONTRACT OR TORT ARISING OUT OF OR RELATED TO
ITS PRODUCTS SHALL NOT EXCEED THE PURCHASE PRICE.
This warranty applies to all Sullivan-Palatek Platinum stationary industrial air compressors of 15D horsepower or
greater shipped after January 1, 2008 superseding previous warranty policies, except to the extent expressly
superseded by a later warranty. In the event of any conflict between this warranty and earlier warranty
statements, the terms of this warranty will control.
43
_____________________________________SULLIVAN-PALATEK
44
SULLIVAN-PALATEK_____________________________________
45
_____________________________________SULLIVAN-PALATEK
46
SULLIVAN-PALATEK_____________________________________
47
_____________________________________SULLIVAN-PALATEK
48
SULLIVAN-PALATEK_____________________________________
49
_____________________________________SULLIVAN-PALATEK
50
SULLIVAN-PALATEK_____________________________________
51
_____________________________________SULLIVAN-PALATEK
52
SULLIVAN-PALATEK_____________________________________
SULLIVAN - PALATEK COMPRESSOR MAINTENANCE LOG
S/N:
SERVICE DIST:
SERVICE
BY
OIL LEVEL
OIL RET.
CLEAR
LINE PRESS
TEMP
FILL OUT FOR EACH SERVICE OR REPAIR. MORE THAN ONE LINE MAY BE USED
PER EACH SERVICE OR REPAIR. THIS FORM MAY BE PHOTOCOPIED AS NEEDED.
SERVICE
CHANGE
CHANGED PART
DATE HOURS
NUMBER
AIR/OIL SEP
OIL
FILTER ELE
53