Mechanical/ Electrical Operations and Interlocks

1. Local Electrical Interlock


a. Circuit Breaker Q0 Close
Local/
Remot
e
Switch
Remot
e

DS

CLOSE

LOCAL

CLOSE

LOCAL

OPEN

LOCAL

OPEN

LOCAL

CLOSE

LOCAL

INTR
G

LOCAL

CLOSE

LOCAL

CLOSE

LOCAL

CLOSE

LOCAL

OPEN

LOCAL

OPEN

LOCAL

OPEN

Spring

Trip

ES H05

Charge

Relays

Operation

CHECK
ED

OPEN

Charged

NOT
POSSIBLE

OK

OPEN

Charged

POSSIBLE

OK

OPEN

Charged

POSSIBLE

OK

OPEN

Charged

POSSIBLE

OK

OPEN

CLOSE

Charged

POSSIBLE

OK

CLOS
E

OPEN

Charged

OPEN

OPEN

Charged

DSH0
5

ES
OPE
N
OPE
N
OPE
N
CLO
SE
OPE
N
OPE
N
INT
RG
OPE
N
OPE
N
OPE
N
OPE
N
OPE
N

CLOS
E
CLOS
E
OPE
N
CLOS
E

INTR
G
CLOS
E
CLOS
E

OPEN

Charged

INTRG

Charged

OPEN

NOT
Charged

NOT
OPRT
NOT
OPRT
NOT
OPRT
NOT
OPRT
NOT
OPRT
NOT
OPRT
NOT
OPRT
NOT
OPRT
NOT
OPRT
NOT
OPRT

OPEN

OPEN

Charged

OPRT

OPEN

OPEN

Charged

OPRT

NOT
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE
POSSIBLE

b. Circuit breaker Q0 Open


Local/
Remote
Switch

ES

ES
H05

Remote

OPEN

OPEN

Local
Local
Local

OPEN OPEN
CLOS
OPEN
E
CLOS
OPEN
E

Operation
NOT
POSSIBLE
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE

CHECKE
D
OK
OK
OK
OK

c. Disconnector Q1 Open/Close
Page 1 of 3

OK
OK
OK
OK
OK
OK
OK

Local/Remo
te
SWITCH

CB

ES

Remote

OPEN

OPEN

Local

OPEN
CLO
SE
OPE
N

OPEN

Local
Local
Local

OPEN

OPEN
INTR
G
CLO
SE

Operation
NOT
POSSIBLE
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE

CHECKE
D
OK
OK
OK
OK
OK

d. Earth Switch Q5 Close


Local/
Remo
te
Switc
h

DS
CB

DS

DS
H05

Spring

H06-

BUS

BUS

VT

VT

H07

Charge

MCB

Voltag
e
Monito
r

Remo
te

OPE
N

OPEN

CLOS
E

OPEN

Charge
d

CLOS
E

ON

DEAD

LOCA
L

OPE
N

OPEN

CLOS
E

OPEN

Charge
d

CLOS
E

ON

DEAD

LOCA
L

CLO
SE

OPEN

CLOS
E

OPEN

Charge
d

CLOS
E

ON

DEAD

LOCA
L

OPE
N

CLOS
E

CLOS
E

OPEN

Charge
d

CLOS
E

ON

DEAD

LOCA
L

OPE
N

INTE
RG

CLOS
E

OPEN

Charge
d

CLOS
E

ON

DEAD

LOCA
L

OPE
N

OPEN

OPE
N

OPEN

Charge
d

CLOS
E

ON

DEAD

LOCA
L

OPE
N

OPEN

CLOS
E

CLOS
E

Charge
d

CLOS
E

ON

DEAD

LOCA
L

OPE
N

OPEN

CLOS
E

INTE
RG

Charge
d

CLOS
E

ON

DEAD

LOCA
L

OPE
N

OPEN

CLOS
E

OPEN

NOT
Charg
ed

CLOS
E

ON

DEAD

LOCA
L

OPE
N

OPEN

CLOS
E

OPEN

Charge
d

OPE
N

ON

DEAD

LOCA
L

OPE
N

Charge
d

CLOS
E

EART
H

DEAD

OPEN

CLOS
E

OPEN

Operatio
n

CHECK
ED

NOT
POSSIBL
E
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL
E
NOT
POSSIBL

Page 2 of 3

OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK

LOCA
L

OPE
N

OPEN

CLOS
E

OPEN

Charge
d

CLOS
E

ES
H05

Operation

ON

LIVE

E
NOT
POSSIBL
E

e. Earth switch Q5 Open


Local/
Remote
Switch
Remote
Local
Local
Local

ES

OPEN OPEN
OPEN OPEN
CLOS
OPEN
E
CLOS
OPEN
E

POSSIBLE
POSSIBLE
NOT
POSSIBLE
NOT
POSSIBLE

CHECKE
D
OK
OK
OK
OK

Remarks

Page 3 of 3