You are on page 1of 8

ZheJiang University Sensing Instruments Co.

LTD
http://www.sensing.net.cn
0571-28860611
0571-28860610

Date:2006-04-25

GE - LOV 8623 228 T5RF(49237)

Luminaire Property
Voltage: 220 V
Current: 0.2772 A
Power: 60.12 W
Power Factor: 0.9845
Weight: Kg
Width: 250mm
Height: 50mm

Report NO.:
Test NO.: SENSING060428-3
Lamp: T5F28W/835(90256/39985)
Sum Lumens: 5093 lm
Number of Lamps: 2
Diameter: mm
Length: 1180mm
Photometric Type: Type C

Photometric Results
Angle of maximum intensity: C:90.0 G:25.0
Half Peak Side Angle(50%): Left: -76.0 Right:24.2
Beam Angle(10%): Left: -87.8 Right:37.0

Lumens: 2353.49 lm
Efficiency: 46.21%
Central Intensity: 1104.886cd
Maximum Intensity: 1196.132cd

Light Distribution Curve C0/C180

Light Distribution Curve C90/270

90

90

239.23

239.23

478.45

478.45

717.68

717.68
60

956.90
1196.13

45

cd

1196.13

1196.13

956.90

717.68

717.68

478.45

478.45

239.23

239.23

180

Fig. C0 / C180
Equipment:Sensing GMS-2000
Temperature:25

-180

45

cd
cd

1196.13

956.90

-180

60

956.90

cd

180

Fig. C90 / C270


Date:2006-04-25
Humidity:60%

Operator:xie
Distance:16.15m

Page 1

GE - LOV 8623 228 T5RF(49237)

Photometric Data Table [cd]


C\G
0.0
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0
195.0
210.0
225.0
240.0
255.0
270.0
285.0
300.0
315.0
330.0
345.0
360.0

0.0
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9
1104.9

2.5
1111.1
1099.4
1088.9
1089.5
1097.3
1106.9
1105.9
1108.2
1109.3
1117.9
1117.1
1112.4
1109.8
1098.8
1089.2
1086.3
1090.5
1102.5
1103.3
1105.1
1109.0
1115.8
1118.7
1115.0
1111.1

5.0
1110.3
1096.0
1088.7
1092.3
1102.0
1111.4
1109.8
1112.4
1113.2
1110.8
1114.0
1108.2
1103.0
1095.5
1086.8
1085.5
1090.5
1103.5
1105.4
1108.5
1109.0
1115.5
1117.1
1114.0
1110.3

7.5
1104.3
1088.4
1085.8
1096.5
1108.2
1117.4
1118.7
1118.4
1114.8
1115.3
1107.5
1097.5
1091.5
1087.6
1083.7
1084.2
1090.2
1105.6
1107.5
1112.1
1111.1
1115.8
1114.5
1108.0
1104.3

10.0
1090.2
1072.5
1078.8
1096.5
1114.5
1126.2
1127.3
1126.2
1117.9
1112.1
1097.8
1082.7
1072.0
1073.3
1075.6
1082.4
1093.4
1110.1
1117.1
1117.1
1115.3
1115.0
1107.2
1097.3
1090.2

12.5
1067.5
1051.6
1064.4
1092.3
1120.5
1135.9
1138.8
1133.8
1121.3
1103.8
1079.8
1058.9
1049.5
1052.9
1062.6
1079.0
1095.7
1116.6
1125.7
1125.2
1118.4
1110.8
1092.8
1075.4
1067.5

15.0
1042.2
1028.4
1046.2
1084.2
1124.7
1146.6
1149.2
1144.0
1122.3
1092.3
1060.5
1034.7
1022.2
1029.7
1045.6
1071.2
1098.3
1123.9
1134.3
1134.8
1120.8
1102.5
1073.5
1051.4
1042.2

17.5
1015.6
1003.4
1028.7
1073.5
1125.4
1158.1
1164.6
1152.6
1121.0
1080.3
1040.2
1009.1
994.5
1006.0
1025.6
1061.0
1100.4
1133.3
1147.9
1145.5
1124.4
1088.2
1053.7
1026.9
1015.6

20.0
987.5
975.5
1008.9
1060.8
1124.1
1169.8
1179.2
1164.6
1118.7
1066.8
1016.7
981.5
965.6
978.6
1005.5
1050.9
1100.9
1144.2
1162.0
1156.7
1123.4
1075.1
1032.1
1001.3
987.5

22.5
955.7
950.2
985.6
1046.4
1121.0
1181.8
1191.7
1172.4
1112.9
1051.1
992.7
952.5
934.8
948.6
983.6
1037.0
1098.6
1155.7
1176.6
1170.8
1119.7
1060.8
1009.9
971.8
955.7

C\G
0.0
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0
195.0
210.0
225.0
240.0
255.0
270.0
285.0

25.0
922.0
919.4
961.4
1030.0
1111.6
1184.1
1196.1
1175.5
1104.8
1031.3
966.9
919.4
901.7
921.0
959.0
1022.9
1093.9
1165.4
1191.4
1181.5

27.5
886.3
886.0
934.0
1008.9
1096.2
1177.4
1192.5
1166.1
1088.4
1010.2
935.8
888.6
868.3
888.6
932.7
1005.5
1084.5
1167.2
1196.1
1184.1

30.0
850.3
849.2
902.4
985.4
1072.5
1161.7
1179.4
1147.9
1065.5
984.1
906.1
852.6
829.4
854.7
904.0
985.6
1072.5
1161.2
1193.3
1177.4

32.5
808.3
811.7
866.2
951.5
1038.1
1132.0
1153.4
1117.1
1031.0
948.4
869.3
812.2
786.9
816.4
871.7
958.5
1050.6
1144.5
1181.0
1158.6

35.0
764.2
768.6
826.0
908.7
996.6
1087.4
1113.7
1075.6
988.5
904.0
828.4
772.6
749.3
776.7
833.3
925.1
1017.5
1114.2
1153.4
1126.2

37.5
720.9
726.1
779.1
858.9
941.6
1032.3
1063.4
1019.8
937.1
855.5
782.7
727.2
706.0
732.4
790.6
882.6
974.4
1069.9
1111.4
1077.2

40.0
675.8
676.8
727.2
798.4
878.5
963.7
1002.3
957.0
872.5
795.2
730.0
683.1
664.1
688.0
742.8
828.1
919.4
1010.4
1056.9
1020.3

42.5
628.1
627.5
669.5
728.2
800.7
883.4
912.4
876.9
796.3
729.5
673.7
634.1
619.2
640.6
689.4
768.9
852.6
944.4
993.2
949.4

45.0
573.3
571.5
608.2
652.1
716.7
777.5
802.8
770.7
715.2
655.2
614.0
581.4
566.5
588.9
632.5
694.3
775.9
854.2
893.3
857.6

47.5
503.9
500.0
536.0
566.5
610.6
654.4
681.3
660.1
612.9
570.7
544.6
516.7
504.2
528.9
569.6
613.7
687.0
741.5
777.5
743.9

Equipment:Sensing GMS-2000
Temperature:25

Date:2006-04-25
Humidity:60%

Operator:xie
Distance:16.15m

Page 2

GE - LOV 8623 228 T5RF(49237)

Photometric Data Table [cd]


300.0
315.0
330.0
345.0
360.0

1114.0
1044.6
984.6
940.8
922.0

1105.9
1025.0
957.5
907.7
886.3

1090.5
1002.9
927.0
871.9
850.3

1065.7
975.5
893.3
833.3
808.3

1032.9
939.5
852.4
792.4
764.2

986.4
895.1
807.5
747.8
720.9

929.0
838.3
756.9
700.3
675.8

859.4
777.0
704.2
652.6
628.1

779.3
700.3
643.2
595.2
573.3

687.8
618.7
575.6
528.7
503.9

C\G
0.0
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0
195.0
210.0
225.0
240.0
255.0
270.0
285.0
300.0
315.0
330.0
345.0
360.0

50.0
406.1
410.5
447.0
471.6
503.1
539.4
556.1
542.0
503.6
481.2
463.0
432.4
418.4
452.5
492.2
526.1
574.3
623.1
651.3
623.6
576.7
529.2
495.6
440.8
406.1

52.5
298.4
302.8
345.6
375.1
391.8
425.1
436.4
431.1
400.1
387.6
368.8
332.8
317.7
353.2
400.6
432.7
463.7
502.3
517.0
501.3
458.0
431.7
392.0
333.9
298.4

55.0
200.1
204.7
241.5
271.5
288.7
313.2
320.6
320.3
299.7
287.2
266.8
230.0
219.4
244.9
296.0
328.9
353.7
385.5
390.5
382.4
347.7
326.0
280.1
228.0
200.1

57.5
123.6
127.3
148.1
179.7
194.6
216.7
213.1
220.9
206.0
194.1
170.8
145.3
139.5
155.2
193.8
229.3
251.4
271.0
269.2
267.3
243.9
218.8
177.1
137.7
123.6

60.0
79.0
80.9
89.7
105.1
122.6
146.8
154.4
152.1
132.0
119.5
103.8
92.9
89.7
98.1
117.4
144.0
164.3
178.1
171.1
173.4
157.8
135.1
104.9
87.4
0.0

62.5
54.5
55.6
59.2
63.9
80.1
102.0
111.1
107.2
84.8
73.3
67.0
63.4
62.1
65.2
74.1
85.8
100.9
122.3
123.6
117.9
96.0
76.9
66.8
58.4
0.0

65.0
39.4
39.6
40.4
40.4
50.9
64.7
73.6
69.6
55.8
45.6
47.2
45.9
44.9
46.7
50.6
51.9
65.7
82.2
84.0
76.7
60.5
46.9
45.1
41.7
0.0

67.5
29.2
29.2
29.5
28.2
31.6
41.5
48.0
44.9
35.0
32.1
33.9
33.9
33.9
34.2
35.7
35.5
41.7
52.2
54.0
47.5
36.8
31.3
32.1
30.3
0.0

70.0
21.9
22.2
21.1
19.6
20.6
24.8
29.2
29.0
23.7
23.2
25.0
25.3
25.6
25.8
25.8
25.0
26.9
33.4
34.2
29.0
23.2
21.9
23.2
22.4
0.0

72.5
16.2
16.4
15.1
14.3
14.1
17.0
19.3
18.8
16.2
16.4
18.0
19.0
19.0
18.5
18.3
18.0
18.3
21.4
21.1
18.5
15.4
15.6
17.0
17.0
0.0

C\G
0.0
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0

75.0
12.0
11.7
10.7
9.7
9.1
10.4
12.5
12.5
11.5
12.0
13.3
14.3
14.3

77.5
8.3
8.3
7.6
7.0
6.5
6.8
7.6
7.8
7.3
7.8
8.6
9.4
10.7

80.0
5.7
5.5
4.7
4.7
4.2
4.4
4.2
4.7
5.0
5.5
6.0
6.5
7.3

82.5
3.7
3.7
3.1
2.9
2.3
2.3
2.3
2.6
2.9
3.1
3.1
3.9
5.0

85.0
1.6
2.1
1.6
1.6
1.6
0.8
0.8
0.8
1.3
1.6
2.1
1.8
2.9

87.5
0.8
0.8
0.8
0.8
0.8
0.5
0.5
0.8
0.8
0.8
0.8
0.8
0.8

90.0
0.8
0.5
0.8
0.8
0.8
0.8
0.5
0.5
0.5
0.3
0.3
0.8
0.3

92.5
0.8
0.8
1.6
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.6
0.8
0.3

95.0
0.3
1.0
1.6
7.0
4.2
2.3
1.6
2.3
3.4
7.3
0.8
0.8
0.8

97.5
0.8
1.0
1.6
1.8
3.9
10.2
11.2
8.9
3.7
1.3
1.3
0.8
0.8

Equipment:Sensing GMS-2000
Temperature:25

Date:2006-04-25
Humidity:60%

Operator:xie
Distance:16.15m

Page 3

GE - LOV 8623 228 T5RF(49237)

Photometric Data Table [cd]


195.0
210.0
225.0
240.0
255.0
270.0
285.0
300.0
315.0
330.0
345.0
360.0

13.8
13.3
12.8
12.8
14.1
13.8
12.3
10.7
11.0
11.7
12.3
0.0

9.4
9.1
8.9
8.6
8.9
8.3
7.3
7.0
7.8
8.1
8.6
0.0

C\G
0.0
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0
195.0
210.0
225.0
240.0
255.0
270.0
285.0
300.0
315.0
330.0
345.0
360.0

100.0
0.8
1.0
1.6
2.1
2.6
2.1
2.1
2.3
2.3
1.8
1.6
0.8
0.8
0.8
1.8
2.1
2.1
1.8
2.1
2.1
2.1
1.8
1.3
0.8
0.0

102.5
0.5
1.0
1.8
1.8
2.3
2.9
2.9
2.3
2.3
2.1
1.6
0.8
0.8
0.8
1.8
1.8
2.1
2.3
2.3
2.3
2.1
1.8
1.0
0.8
0.0

105.0
0.5
0.8
1.6
2.1
2.1
2.6
2.3
2.3
2.3
1.8
1.6
0.8
0.8
0.8
1.3
2.1
2.3
2.1
2.9
2.1
2.1
1.8
1.3
0.8
0.0

107.5
0.8
0.8
1.3
2.1
2.3
2.3
2.9
2.3
2.3
2.3
1.8
0.8
0.8
0.8
1.8
2.1
2.3
2.6
2.6
2.1
2.1
2.1
1.8
0.8
0.0

110.0
0.8
0.8
1.8
2.1
2.6
2.9
2.6
2.9
2.1
2.1
2.1
0.8
0.8
1.0
1.8
2.1
2.3
2.3
2.3
2.3
2.1
1.8
1.6
0.8
0.0

112.5
0.8
0.8
1.6
2.1
2.9
3.1
2.9
3.1
2.6
2.3
1.8
0.8
0.8
0.8
1.6
1.8
2.3
2.6
2.3
2.3
2.6
1.8
1.6
0.8
0.0

115.0
0.5
0.8
1.6
2.1
2.9
3.1
3.1
3.1
2.6
2.1
1.6
0.8
0.8
0.8
1.6
2.1
2.3
2.9
2.9
2.6
2.3
1.8
1.6
0.8
0.0

117.5
0.5
0.8
1.6
2.6
2.6
2.9
2.9
2.9
2.3
2.6
1.6
0.8
0.8
0.8
1.3
2.1
2.3
2.6
2.9
2.6
2.3
2.1
1.6
0.8
0.0

120.0
0.5
0.8
1.6
2.1
2.1
2.9
2.9
2.9
2.6
2.1
1.6
0.8
0.8
0.8
1.8
1.8
2.1
2.3
2.6
2.3
2.3
2.1
1.3
0.8
0.0

122.5
0.8
0.8
1.3
1.8
2.6
2.3
2.6
2.3
2.6
2.1
0.8
0.8
0.8
0.8
1.6
1.8
2.3
2.9
2.6
2.3
2.3
2.1
1.6
0.8
0.0

C\G
0.0
15.0
30.0
45.0
60.0
75.0

125.0
0.8
0.8
0.8
1.6
2.6
2.9

127.5
0.8
0.8
0.8
1.3
2.3
2.6

130.0
0.8
0.8
0.8
1.3
1.8
2.1

132.5
0.8
1.0
1.3
1.3
2.1
2.3

135.0
0.8
0.8
0.8
1.3
2.1
2.1

137.5
0.8
0.8
0.8
1.3
1.8
2.3

140.0
0.8
0.8
1.0
1.3
1.8
2.1

142.5
1.0
1.3
1.3
1.3
1.8
2.3

145.0
1.0
1.3
1.6
1.8
1.6
2.1

147.5
1.8
1.6
1.6
1.8
1.8
2.3

Equipment:Sensing GMS-2000
Temperature:25

6.8
6.3
6.0
5.5
5.0
5.2
5.0
4.2
5.0
5.0
5.7
0.0

4.2
3.9
3.7
3.4
3.1
2.9
3.1
2.9
3.1
3.4
3.4
0.0

Date:2006-04-25
Humidity:60%

2.6
2.3
2.1
1.6
1.6
1.3
1.3
1.6
1.8
1.8
2.1
0.0

0.8
0.8
0.8
0.5
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.0

0.5
0.8
0.5
0.5
0.5
0.3
0.3
0.5
0.5
0.8
0.5
0.0

0.8
0.8
0.8
0.8
0.3
0.8
0.5
0.5
0.8
1.3
0.8
0.0

Operator:xie
Distance:16.15m

0.8
1.0
3.1
1.8
0.8
0.8
0.8
1.6
2.9
0.8
0.8
0.0

0.8
0.8
1.6
1.8
5.2
6.0
4.2
1.3
1.8
1.0
1.0
0.0

Page 4

GE - LOV 8623 228 T5RF(49237)

Photometric Data Table [cd]


90.0
105.0
120.0
135.0
150.0
165.0
180.0
195.0
210.0
225.0
240.0
255.0
270.0
285.0
300.0
315.0
330.0
345.0
360.0

2.9
2.6
2.3
1.8
0.8
0.8
0.8
0.8
1.0
2.1
2.3
2.6
2.6
2.6
2.1
1.8
1.6
0.8
0.0

C\G
0.0
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0
195.0
210.0
225.0
240.0
255.0
270.0
285.0
300.0
315.0
330.0
345.0
360.0

150.0
1.8
2.1
2.1
2.1
1.8
2.6
2.3
2.1
2.3
2.3
2.3
2.1
1.8
2.1
1.8
2.3
2.3
2.6
2.9
2.3
2.3
2.1
2.1
1.8
0.0

2.9
2.3
1.8
1.6
0.8
0.8
0.8
0.8
0.8
1.8
2.3
2.3
2.3
2.3
2.3
2.1
0.8
0.8
0.0

152.5
2.1
2.1
2.3
2.3
2.3
2.3
2.6
2.6
2.6
2.3
2.3
2.1
2.1
2.1
2.3
2.3
2.3
2.9
2.9
2.9
2.1
2.1
2.1
2.3
0.0

Equipment:Sensing GMS-2000
Temperature:25

2.3
2.1
2.1
1.3
0.8
0.8
0.8
0.8
1.3
1.8
2.1
2.3
2.6
2.3
2.1
2.1
1.0
0.8
0.0

155.0
2.6
2.9
2.3
2.6
2.9
2.9
2.9
2.6
2.9
3.1
2.9
2.9
2.3
2.9
2.3
2.6
2.6
2.9
2.6
2.3
2.3
2.1
2.6
2.9
0.0

2.6
2.1
1.6
1.6
1.0
0.8
0.8
0.8
1.0
2.1
2.1
2.6
2.3
2.3
1.8
1.8
0.8
0.8
0.0

157.5
3.1
2.9
2.9
2.9
2.9
3.1
2.9
3.1
2.9
3.1
3.4
3.1
3.4
3.1
3.1
3.1
2.9
2.6
3.1
2.9
2.3
2.6
2.3
2.9
0.0

Date:2006-04-25
Humidity:60%

2.3
2.6
2.1
1.8
0.8
1.0
0.8
0.8
0.8
1.8
2.1
2.3
2.9
2.1
1.8
1.6
1.3
0.8
0.0

160.0
3.4
3.1
2.9
3.1
3.1
3.4
3.1
3.4
3.7
3.9
3.9
4.2
3.7
3.4
3.7
3.4
3.1
3.7
3.1
2.9
3.4
2.9
3.1
3.1
0.0

2.3
2.1
1.8
1.6
0.8
0.8
0.8
0.8
0.8
1.8
2.3
2.6
2.6
2.9
2.1
1.6
0.8
0.8
0.0

162.5
4.2
3.7
3.4
3.4
3.7
3.7
3.9
4.2
4.2
5.2
5.2
5.0
4.2
4.4
4.4
4.4
3.9
3.7
3.7
3.4
3.4
3.1
3.1
3.7
0.0

2.3
2.1
2.1
1.8
1.6
1.6
0.8
1.0
1.0
2.1
2.6
2.6
2.9
2.3
2.3
1.8
1.0
0.8
0.0

165.0
5.0
3.9
3.7
3.7
3.9
4.4
5.0
5.2
6.3
6.0
6.3
6.3
4.7
5.2
6.0
5.5
5.0
4.7
4.2
3.7
3.7
2.9
3.4
3.7
0.0

2.1
2.3
1.8
1.6
1.3
1.8
0.8
1.0
1.0
1.6
2.3
2.6
3.1
2.6
2.1
1.6
1.0
0.8
0.0

167.5
5.5
4.7
4.2
3.9
4.4
5.2
6.3
6.5
6.8
7.0
7.0
6.5
5.7
6.0
6.8
6.8
6.5
5.7
4.7
4.4
3.7
3.9
3.4
4.2
0.0

Operator:xie
Distance:16.15m

2.3
2.1
1.8
1.6
1.8
1.8
1.3
1.8
1.6
2.1
2.6
2.9
2.6
2.6
2.1
1.8
1.0
1.3
0.0

2.6
2.1
2.1
2.1
1.8
1.8
1.8
1.8
1.8
1.8
2.3
2.6
3.1
2.9
2.1
1.6
1.8
1.8
0.0

170.0
6.3
5.0
4.4
4.7
5.2
6.3
6.8
7.3
8.1
7.8
7.8
7.3
6.5
6.5
7.6
7.8
7.3
7.0
6.3
5.0
5.0
3.9
3.9
5.0
0.0

172.5
6.8
5.7
5.0
5.0
5.7
6.0
7.0
8.1
8.1
8.3
7.8
7.6
7.0
7.3
7.3
7.6
7.3
7.0
6.3
5.5
5.2
4.7
4.4
5.2
0.0

Page 5

GE - LOV 8623 228 T5RF(49237)

Photometric Data Table [cd]


C\G
0.0
15.0
30.0
45.0
60.0
75.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0
195.0
210.0
225.0
240.0
255.0
270.0
285.0
300.0
315.0
330.0
345.0
360.0

175.0
7.3
6.5
5.2
5.0
5.7
6.5
7.3
7.3
7.3
7.6
6.8
7.3
7.6
7.0
6.8
6.8
7.0
6.8
6.5
5.7
5.0
4.4
5.0
5.7
0.0

177.5
7.3
6.5
5.5
5.7
5.5
6.5
7.0
6.8
7.0
6.8
7.0
7.3
7.6
7.0
6.5
6.5
6.0
6.3
6.0
5.5
5.0
5.2
5.2
6.3
0.0

Equipment:Sensing GMS-2000
Temperature:25

180.0
7.6
7.0
6.0
5.5
5.5
6.3
6.3
6.3
6.0
6.0
6.3
6.8
7.6
7.0
6.0
5.5
5.5
6.3
6.3
6.3
6.0
6.0
6.3
6.8
0.0

Date:2006-04-25
Humidity:60%

Operator:xie
Distance:16.15m

Page 6

GE - LOV 8623 228 T5RF(49237)

Light Distribution Curve [Unit: cd]

+/-180

-90

90
239.23
478.45
717.68
956.90
1196.13

1196.13
956.90
717.68
478.45
239.23

-180

(cd) |

Equipment:Sensing GMS-2000
Temperature:25

180

Light Distribution Curve (Linear)


C0/C180:
C90/C270:

Date:2006-04-25
Humidity:60%

Operator:xie
Distance:16.15m

Page 7

GE - LOV 8623 228 T5RF(49237)

Iso-Lux[lx]
10.
106.32 (80%Emax)
83.73 (63%Emax)

8.

66.45 (50%Emax)
33.23 (25%Emax)
21.26 (16%Emax)

6.

13.29 (10%Emax)

4.

2.

0.

2.

4.

6.

8.

10.
10.

8.

6.

4.

2.

0.

2.

4.

6.

8.

Height: 3 m
Max Illuminance : 132.9lx

Equipment:Sensing GMS-2000
Temperature:25

Date:2006-04-25
Humidity:60%

Operator:xie
Distance:16.15m

Page 8