You are on page 1of 7

INSTRUCTION FOR

TRANSDUCER SET-UP

HE-7300-Di
HE-1500-Di

Transducer set-up for HE-7300-Di and HE-1500-Di


Thank you for purchasing HONDEX products. This document explains the transducer
setting for New VF Models : HE-7300-Di and HE-1500-Di.
Please read this document carefully to set the transducer properly.
1. Initial Setting of Transducer
1-1. When you turn on the Power initially, the following window appears.

Press SET or > so that frequency set-up menu appears.

1-2. Select transducer from the list, then press MENU key.

When selecting OTHER TD, it is necessary to set-up the details of transducer


manually on the following window.

1-3. Following display appears. Press MENU key to complete the set-up. You can also press
SET key to return to the transducer list.

*Wrong set-up may damage on the product or transducer.

2. Set-up Transducer
2-1. Indicate the transducer list.
Go to MENU3 8 INITIALIZE 4 TRANSDUCER SET.
2-2. Select a transducer.
Transducer List Display

3. Set-up Other Transducer


It is necessary to select OTHER TD when using any transducer other than transducer list
or 2 different transducers.
3-1. Indicate the transducer list. The value shown is the current set-up frequency.
Go to MENU3 8 INITIALIZE 4 TRANSDUCER SET.

This is the current frequency


set-up value.

3-2. Select OTHER TD to show the display for detailed set-up of transducer.

3-3. Set-up each item on the display. Please refer to the followings for more explanation on
the detailed set-up.

4. Detailed Set-up
Type of Transducer
Select the type of transducer.
Single :

Single frequency transducer

Dual(3P): Dual frequencies by 1 transducer


Dual(5P): Dual frequencies with 5P plug or 2 transducers.
[Caution]
-

Additional junction cable, BK01, is required when connecting 2 transducers.

The transducer connector needs to e 5P plug when connecting 2 transducers.

Refer to the following information about each detailed transducer set-up and pin assignment
for each connector.

FREQ. TX
Set the transmitted frequency from transmitter.
Selectable from 27~250kHz.
NOMINAL FREQ.
Set the frequency to be shown on the display.
This value is indicated on the display. Selectable from 20~300kHz.
TRANS TAP
Optimize the matching of transmitter and transducers impedance.
Select A when no selection is shown in Transducer List on the previous menu.
When using 2 transducers, it is necessary to set manually. Refer to the attached Setting List
for Standard Transducer and select the level for each.
Initial set-up : A (Minimum Level)

Higher level set-up (B, C, D) may cause damage on transducer and main unit.

5. Set-up Value for HONDEX Transducer

1st Edition JAN2012

You might also like